Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹21.7 L+₹1.7 L (8.60%)Rejected-AOC WZ 88A JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | L2 | Rejected-AOC Not L1 bidder | |
| 3 | L3₹22.0 L+₹2.0 L (10.3%)Rejected-AOC E 73 FF GALI NO 17B SADH NAGAR PALAM COLONY NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L3 | Rejected-AOC Not L1 bidder | |
| 4 | L4₹22.7 L+₹2.8 L (14.0%)Rejected-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L4 | Rejected-AOC Not L1 bidder | |
| 5 | L5₹22.9 L+₹2.9 L (14.7%)Rejected-AOC RZ 140 A EAST SAGARPUR STREET NO 7 8 NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L5 | Rejected-AOC Not L1 bidder |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
27 Apr 2024, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
PETTY REPAIRS FOR ATTENDING DAY TO DAY EXTERNAL STP TREATED WATER SUPPLY ELECTRIC SUPPLY COMPLAINTS AT SHANKAR VIHAR, VIKRAM VIHAR ANUJ VIHAR 200 DU DGIS CAMS AND ALLIED AREA UNDER AGE U WATER SUPPLY NO III UNDER GE U WATER SUPPLY DELHI CANTT 10
2024_MES_648583_1
GE/WS/IFA-113/Token-63 OF 2023-24
Open Tender
Civil Works
Item Rate
330 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹64,000
Yes
3 Sept 2024
30 Mar 2024
29 Apr 2024
30 Mar 2024
27 Apr 2024
13 Apr 2024
Amount
Labour only for attending day to day external (treated water supply of STP) complaints of the various areas as mentioned in subject work of all nature including grey water pipe leakage i.e leakage in water supply pipe lines, fitting/fixture, over flow of overhead tank, no water supply in supply tank and taking out water from trenches during repair including write down the complaints in complaint register book complete all as specified and as directed. (Note 1 :- Any material required for attending complaints for rectification shall be measured and paid separately under respective item herein after) (Note 2 :- Quoted rates includes following other aspects as srl No. 2 (i) to 2 (xiii) below).
Labour only for attending of Electric supply compliants of day to day maintenace of existing LT Panels including connecting electrical accessories / spares of water supply installation and electrical fitting & light, short circuits in Pump house of the areas as mentioned in subject work complete all as specified and as directed. (Note 1 :- Any material required for attending complaints for rectification shall be measured and paid separately under respective item herein after) (Note 2 :- Quoted rates includes following other aspects as srl No. 2 (i) to 2 (xiii) below).
Notes for item No. 1.00 & 2.00 (i) The complaints shall be attended and the defects shall be rectified by a team of expert and experienced electrician/plumber as applicable assisted with adequate numbers of helpers complete all as specified and as directed. Minimum requirements of skilled and unskilled workers for whole contract period are as under:- (a) One plumber or fitter with one helper. (b) One Electrician or fitter with one helper. (ii) Requirement of additional workers if required for rectification of any complaint (occationally) will be provided by contractor on urgent requirement basis as directed by EIC without any extra cost.
(iii) The complaints shall be attended and defect shall be rectified within 04 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 250/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues. Contractor shall appoint supervisor / staff for receive and register of complaints received in person/through telephone/mobile whatsapp and issue and control contractors stores and workers will required to available within time daily at 0800 hrs to 2000 Hrs to receive and notify each complaint. Attendence register of workers daily basis will provided by the contractor supervisor must be technically qualified and minimum 12th passed with adepuate experience of management of electrical/plumbing team work duly signed by JE E/M & Eng-in-Charge.
(iv) In case, after checking and attending the defect, it is not possible to rectify the defects within 08 hrs the facts shall be brought to the notice of Engineer-in -charge by the contractor /his rep . If Engineer -in-charge is satisfied with contractors view, no recovery will be made.
(v) While attending the complaint of treated STP water supply /Electric supply, if earth work is required then the same shall be measured and paid seperately under respective item of Sch 'A' . However no extra payments shall be made for dewatering.
(vi) Cutting of GI pipe in position and threading is also deemed to be included in the job rate (Fitting and fixtures will be measured and paid separetely under respective item of Sch A.
(vii) All T & P including safety gears required for attending the complaints shall be provided by the contracor.
(viii) The elecrician shall always be in possession of all Electrician tools , LT Megger, Earth tester , Multimeter , Crimping tool, insulation tape, Hand gloves & water purification test kits for TDS & turbudity etc required at site.
(ix) Old retrived materials, will be deposited by contractor to MES store yard of AGE (U) Water Supply No III at contractor's own arrangement and necessary RV attached with RAR / Final bill mentioning ledger number & page number. Please note that if any material retrieved from excavation/demolition/taking down from site misplaced by contractor then the same will be recovered @ double of market rate from contractor's dues. Hence contractor will provide security to the material or deposit in the same day & kept receipt from deptt. (x) All the fitting /fixtures as mention below item No 3 to 28 and 44to46 & 51to55 of BOQ shall be procured by contractor in one time and the same shall be kept with safe custory of Eng-in-charge store yard at contractor's own arrangement and issue RV to contractor. Piecmeal requirement of fixing of fittings as required at site will be issued by JE (E/M) through Baby indent. Proper register will maintained by contractor for consumption of materials at site with showing debit complaint wise. The same register will be signed by JE (E/M) & Eng-in-Charge and produced with RAR/Final bill. (xi) First RAR will be submitted by contractor for material lying at site only.
(xii) A BOO will be ordered for getting verified of daily consumption of petty repair fittings/fixture items supplied by contractor and issue through Baby Indent daily wise as per received complaints. (xiii) Contractor will be procure bulk material after approved of make of fittings from GE and submit valid e-way bill & Tax Invoice with MTC to EIC for making payment. Purchase voucher / Tax Invoice wil be got verified online from stockist/dealer defacing by EIC.
Supply only of ISI Marked UPVC Socket 'medium grade' ISI Marked of following sizes :-
20 mm bore
25 mm bore
32 mm bore
40 mm bore
50 mm bore
63 mm bore
90 mm bore
110 mm bore
Supply only of ISI Marked UPVC Elbow 'Medium grade', ISI Marked of following sizes : -
20 mm bore
25 mm bore
32 mm bore
40 mm bore
50 mm bore
63 mm bore
90 mm bore
110 mm bore
Supply only of ISI Marked UPVC Reducing socket medium grade ISI marked of the following sizes :-
25 x 20 mm bore
32 x 25 mm bore
40 x 32 mm bore
50 x 40 mm bore
63 x 50 mm bore
90 x 63 mm bore
110 x 90 mm bore
Supply only of ISI Marked UPVC Solid plug heavy duty ISI Marked of following sizes : -
20 mm bore
25 mm bore
32 mm bore
40 mm bore
50 mm bore
Supply only of ISI Marked UPVC Tee Medium grade ISI Marked of following sizes : -
15mm x15mm x15mm
15 mm x 15 mm x 20 mm
20 mm x 20 mm x 20 mm
25 mm x 25 mm x 20 mm
25 mm x 25 mm x 25 mm
32 mm x 32 mm x 32 mm
40 mm x 40 mm x 40 mm
50 mm x 50 mm x 50 mm
63 mm x 63 mm x 63 mm
90 mm x 90 mm x 90 mm
110 mm x 110 mm x 110 mm
Supply only of ISI Marked Service saddles medium grade, of following sizes complete all as specified and as directed.
50 x 15 mm bore
50 X 20 mm bore
50 x 25 mm bore
63 x 20 mm bore
90 x 20 mm bore
110 x 20 mm bore
Supply only 15 mm bore Bib tap of PTMT, any tint, high pressure screwed for male/ female threaded, for pipe of size 15 mm bore (but not less than 125 gram) complete all as specified and as directed.
Carrying samples for Testing of treated water of STP and submission of detailed test report to the office of the Engr-in-charge and detail are as under:- (a) Carrying out minimum essential testing of water as per IS 3025 mandatory for chemical, colour, odour, PH Value, TSS, BOD, COD, residual chlorine, total nitrogen, sulphate, oil and grease, ammonical Nitrogen (NH3-N) and Bacteriological total collifrom organisms per 100 Ml (MPN), Facecal Coliforms (FC), disolved phosphorous and E colilie in 100ml Note - Rate quoted shall deemed to be included for :- (i) Cost of sterilised bottle as required (ii) To and fro transportation charges for collection of sample. (iii) Contractor shall provide necessary test report duly approved by EIC after necessary repairs and blowers output pressure and capacity should not be less than as of existing equipment required.
Supply only of 20 mm bore Bib tap of PTMT, any tint, high pressure screwed for male/ female threaded, for pipe of size 20mm bore (but not less than 175 gram) complete all as specified and as directed.
Supply only loose lead pig in packets for joints complete all as specified and as directed.
Supply only loose Spun Yarn in bundle complete all as specified and as directed.
Supply only Switch Piano flush type 6 amps single pole one way 240 volts complete all as specified and as directed.
Supply only Switch Piano flush type 16 amps, single pole, one way, 240 volts complete all as specified and as directed.
Supply only Switch Socket outlet 2 in 1, 3 pin, 6 amps 240 volts complete all as specified and as directed.
Supply only Switch Socket outlet 2 in 1, 3/5 pin and 16 amps 240 volts complete all as specified and as directed.
Supply only in replacement Switch Socket combination 2 in 1, 3 pin, 6 amps 240 volts complete all as specified and as directed.
Supply only for fixing in replacement Switch Socket combination 2 in 1, 3/5 pin and 16 amps 240 volts complete all as specified and as directed.
Supply only for fixing in replacement MCB SP, 6 to 32 'C' curve Amp, 240 volts complete all as specified and as directed.
Supply only for fixing in replacement sheet metal enclosure MCB,DB 4 way, with 200 amps rated bus bar SPN 240 volts double door and making disturb surface good complete all as specified and as directed.
Supply only for fixing in replacement sheet metal enclosure MCB, DB 8 way, with 200 amps rated bus bar SPN, 240 volts double door and making disturb surface good complete all as specified and as directed.
Supply only for fixing in replacement LED batten arrow for multi application suitable for 18 Watts with & including necessary cable connection to make it functional complete all as specified and as directed.
Supply only for fixing PVC insulation tape role 15 mm wide, 10 Running meter long complete all as specified and as directed.
Supply only for fixing in replacement PVC multistranded aluminium conductor, 1100 volts grade , cross sectional area 4 sqmm, 2 core fixed on panels/walls complete all as specified and as directed.
Supply only for fixing in replacement PVC multistranded aluminium conductor, 1100 volts grade, cross sectional area 6 sqmm, 2 core fixed on panels/walls complete all as specified and as directed.
Supply only for fixing in replacement PVC insulated multistranded copper conductor wire of size 1.5 Sqmm, 1100 volts grade single core fixed on panels/walls complete all as specified and as directed.
Supply only for fixing in replacement of PVC insulated multistranded copper conductor wire of size 2.5 Sqmm, 1100 volts grade single core fixed on panels/walls complete all as specified and as directed. Note for item No 3 to 28: - (i) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of fitting and wire scrap in weight (KG) shall be taken into account and attach with RAR/F Bill) (ii) Making good cost of existing surface shall be included in quoted unit rate.
Supply and fixing in repair connecting and testing new generation energy saving & environmental friendly long life versatile pressure die cast aluminium IP-66 roadway luminaire 90 Watt LED with high power LED as light source suitable for pole/wall dia 63 mm (max) inlcuding making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5 Sqmm complete all as specified and directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in (EACH) shall be taken into account and attach with RAR/F Bill).
Supplying and fixing in replacement UPVC pipes, of following sizes, pressure rating 10 kgf/cm2, heavy duty, including taking out with all pipe fittings such as ends, elbows,unions, tees, reducing tees, adoptors, sockets, plugs, hose clips etc. fixed to walls with fixing arrangements such as saddles (snap clips), wall clips, hooks, protective mild steel tube sleeves , ceilings or in floors etc., complete with and cutting through walls, floors and their making good or laying in trenches and also cutting, screwing and waste including jointing with jointing material complete all as specified and as directed. (Note :- (i) Excavation & earth work for new location shall be measured & paid separetely. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of pipe in (RM) shall be taken into account and attach with RAR/F Bill)
15 mm Bore
20 mm Bore
25 mm Bore
32 mm Bore
40 mm Bore
50 mm Bore
63 mm Bore
90 mm Bore
110 mm Bore
Supplying and fixing in replacement 3 layer PP-R pipes of following sizes, SDR 7.4 (PN-16) UV stabilized and anti microbial fusion welded having thermal stability for hot and cold water with all pipe fittings (plain and brass threaded) such as ends, elbows,unions, tees, reducing tees, adoptors, sockets, plugs, hose clips etc. fixed to walls with fixing arrangements such as saddles (snap clips), wall clips, hooks, protective mild steel tube sleeves , ceilings or in floors and trenches etc., complete with and cutting through walls, floors and their making good or laying in trenches and also cutting, screwing and waste including jointing with jointing material complete all as specified and as directed. (Note :- (i) Excavation and earth work shall be measured and paid seperately. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of pipe in (RM) shall be taken into account and attach with RAR/F Bill).
16 mm bore
20 mm bore
25 mm bore
32 mm bore
40mm bore
50mm bore
63 mm bore
75 mm bore
90 mm bore
110 mm bore
S&F in replacement PPR gate valve for pipe 20mm dia (brass insert) all as directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in (EACH) shall be taken into account and attach with RAR/F Bill).
Supply and fixing High density polythene pipes (HDPE) pipes 90 mm bore, of pressure rating 10 kgf/cm2, heavy duty fixed complete to walls ceilings or in floors with fixing arrangements such as saddles (snap clips), wall clips, hooks, protective mild steel tube sleeves , ceilings or in floors etc., complete with and including taking down old material complete all as specified and as directed.
Supply and fixing High density polythene pipes (HDPE) pipes 110 mm bore, of pressure rating 10 kgf/cm2, heavy duty fixed complete to walls ceilings or in floors with fixing arrangements such as saddles (snap clips), wall clips, hooks, protective mild steel tube sleeves , ceilings or in floors etc., complete with and including taking down old material complete all as specified and as directed.
Supply and fixing High density polythene pipes (HDPE) pipes 160 mm bore, of pressure rating 10 kgf/cm2, heavy duty fixed complete to walls ceilings or in floors with fixing arrangements such as saddles (snap clips), wall clips, hooks, protective mild steel tube sleeves , ceilings or in floors etc., complete with and including taking down old material complete all as specified and as directed. (Notes for srl No 33 to 35 :- (i) Excavation & earth work for new locations shall be measured & paid separetely. (ii) Old U/s HDPE pipe obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of pipe in (RM) shall be taken into account and attach with RAR/F Bill).
Taking up GI/Cast Iron/ Ductile Iron water mains of following bore including all fittings with spigot & socket ends of lead joints including burning out lead joints and recovering lead complete all as specified and as directed. (Note :- (i) Excavation & earth work for new location shall be measured & paid separetely. (ii) Old U/s HDPE pipe obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in (RM) & lead in (KG) shall be taken into account and attach with RAR/F Bill).
100 mm bore
150 mm bore
Supplying, laying, jointing & commissioning DI pipe of following bore as per IS-8239-2000, class K-7 with inside cement mortar lining , spigot & socketed ends, laid in trenches, in new or old location with & including DI fittings with rubber gasket joints complete all as specified and as directed.
100 mm bore
150 mm bore
Material & Labour for Rubber Gasket joint(Tyton) including jointing material for CI/DI Pipe of following sizes complete all as specified and as directed .
100 mm bore
150 mm bore
200 mm bore
Supplying and fixing in replacement CI/ DI Pipe fittings such as Tees, bends, any type, radius and angle/tapers any type, collars, tail pieces, caps and plugs up to 150 mm bore conforming to IS: 1538-1993 including taking down existing fitting complete all as specified and as directed.
Supplying and fixing in replacement CI/ DI Pipe fittings such as Tees, bends ,any type, radius and angle/tapers any type, collars,tail pieces,caps and plugs above 200 mm bore conforming to IS: 1538-1993 including taking down existing fitting complete all as specified and as directed. (Note for item No 39 & 40 :- (i) ld U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) (ii) Excavation and earth work will be measured and paid seperately.
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc in soft/ loose soil getting out and levelling of bottom surface to required level all as specified and as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed.
Removing excavated material to a distance not exc 50 m and depositing where directed not exc 1.5 meters above the starting point complete all as specified and as directed.
Supply only for fixing in replacement of MCCB 4 pole 200 Amps 25 KA complete all as specified and directed.
Supply only for fixing in replacement of MCCB 3 pole 100 Amps 25 KA complete all as specified and directed.
Supply only for fixing in replacement of MCCB 3 pole 63 Amps 16 KA complete all as specified and directed.
Supply, fixing, jointing & testing cast Iron Sluice Valve of following size ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, Confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top including taking out unserviceable sluice valve complete all as specified and as directed . (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in of sluice valve in (EACH) shall be taken into account and attach with RAR/F Bill)
80 mm dia
100 mm dia
150 mm dia
200 mm dia
Supply, installation and testing of flanged ends water meter, ISI marked woltman type class 'B' of following sizes and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/ inclined/ vertical position complete all as specified and directed.
80mm dia
100mm dia
Supply, fixing, jointing and testing of Cast Iron Butterfly Valve of following size ISI marked class (PN 1.0) Disc DI, confirming to IS 13095, having stainless steel stem including taking out unserviceable Butterfly valve complete all as specified and as directed . (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
80mm dia
100mm dia
150 mm dia
Supply, installation and testing flanged ends strainer/ dirt box rating PN 1.0 of following size with stainless steel mesh suitable for cold water meter to avoid foreign material entering into meter and making good connection with flanged ends with gasket rubber sheet and nut & bolts fixing in horizontal/inclined/ vertical position complete stainer Y type confirming to IS supplied and installed complete all as specified and directed by Engr - in - Charge. (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
80mm dia
100mm dia
Labour work required for opening top cover of sluice valve of sizes as under including gland cover, taking out stem with stem nut of brass/SS, gland plates etc and refixing the same after replacement of rubber packing and nuts/bolts/glands dori etc of appropiate sizes. Note :- Any new spare parts like stem, stem nuts, gland plate of required size shall be measured and paid separately under respecitve items.
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supply only 'stem' made out from SS (all as per sample) of sluice valve of size as under : -
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supply only 'stem nut' made out from stainless steel suitable to match with existing sluice valve of sizes as under : -
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supply only 'gland plate' made out CI, suitable to match with existing sluice valve of sizes as under : -
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supply only for fixing in replacement od LED lamp 9 watt complete all as specified and directed
Supply & Fixing in replacement & testing Poly-ethylene water storage tanks(cylindrical vertical with closed top) tripple layered with lid cover of following capacities hoisted and fixed in position at building top. (Note:- (i) Old PVC tank with cover lid wil be deposited by contractor at MES Store Yard at his own arrangement. (ii) Old U/s tank material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in (EACH) shall be taken into account and attach with RAR/F Bill)
(a) 500 Litre
(b) 1000 Litre
SANWARIYA ENTERPRISES
PRASAD ELECTRICALS
Rahul Enterprises
Deven Associates
P S TRADERS
M/s SAAR ENGINEERS
B.R. Enterprises
M/s Adhikari construction co.
Sukhram & Sons
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .