| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.1 LAccepted-AOC SCHOOL LINE NEAR MINNIEBAY JUNCTION SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹20.0 L+₹49,700 (2.55%)Rejected-Finance | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹20.2 L+₹71,736 (3.68%)Rejected-Finance | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹20.4 L+₹96,986 (4.98%)Rejected-Finance | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹21.7 L+₹2.2 L (11.4%)Rejected-Finance | L5 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
16 Aug 2021, 6:00 pmClosed
GE Minniebay
GE, Minniebay, Junglighat (PO), Port Blair -744103
REPAIR / MAINTENANCE TO STREET LIGHT FITTINGS, INTERNAL ELECTRIFICATION AT VAYU VIHAR BROOKSHABAD UNDER AGE E/M II AT GE MINNIEBAY, PORT BLAIR
2021_MES_462126_1
8962/E8
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
GE, Minniebay, Junglighat (PO), Port Blair -744103
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE Minniebay
₹50,000
Yes
28 Oct 2021
24 Jul 2021
24 Aug 2021
24 Jul 2021
16 Aug 2021
10 Aug 2021
Amount
Taking down carefully copper/aluminum point wiring (light, Fan, Socket or power) complete, fitting etc, removing materials from site and making good disturbed surfaces of walls, floors roofs etc in all respect complete all as specified and directed.
Taking down carefully copper/aluminum sub main wiring of size 1.5/2.5/4/6/10/16/25 Sqmm from surface/concealed /existing conduit of any height, removing materials at site and making good disturbed surfaces of walls, floors roofs etc in all respect complete all as specified and directed.
M & L for point wiring with 1.5 Sq.mm (nominal area) PVC unsheathed multi stranded copper conductor PVC insulated 1100 Volts FRLS grade drawn through and including PVC casing capping / conduit ISI marked minimum 20mm size and its accessories complete along with 1.5 Sqmm cable but in green colour as continuous earthing wire and connecting to common earth dolly completely concealed ,surface, in walls/ceiling/roofs with and including 1.2 mm thick MS sheet terminal boxes duly fabricated flush mounting in the wall for mounting switches, switch socket combinations fan regulators etc., as required with 3 mm thick plastic laminated sheet top cover all as specified and directed.
One light /fan/bell point controlled by one switch
One 5 Amps plug point independent board controlled by one switch
One three pin switch socket 5 Amps plug point on same board
All as per item No 3.00 above but with 2.5 Sqmm single core multi stranded copper conductor for one three pin socket 5 Amps on independent board including continuous earth wire PVC insulated 2.5 Sqmm copper solid conductor to common earth dolly complete all as specifed and directed
All as per item No 3.00 above but with 4 Sqmm single core multi stranded copper conductor for one three pin socket 15 Amps on independent board/ metal clad socket for AC point including continuous earth wire PVC insulated 4 Sqmm copper solid conductor to common earth dolly complete all as specifed and directed.
S&F in replacement of switch piano , flush button type , single pole ,one way 15 Amps complete all as specified and directed
S&F in replacement of socket outlet 2-in-1, 3 Pin ,5/ 15 Amps flush type complete all as specified and directed
S&F in replacement of bell push switch 5 Amps for electric Bell / Buzzer, ding dong AC 230 Volt single pole complete all as specified and directed
S&F in replacement of electric Bell, ding dong type AC 230 Volt single pole complete all as specified and directed
S&F in replacement of Switch Piano flush button type, single pole, one way 5 Amp complete all as specified and directed
S&F in replacement of socket piano flush type 2-in-1, 2/3 Pin, 5 Amps all as specified and directed
S&F in replacement of sheet metal enclosure with socket plug top , single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP of capacity 20 to 32 Amps complete all as specified and directed
S&F in replacement of ceiling rose , surface Bakelite 65 mm x 30 mm , 3 terminals complete all as specified and as directed
S&F in replacement of electronic dimmer type regulator 230 Volt step type complete all as specified and as directed
S&F in replacement of Switch socket combination 6 Amps complete all as specified and directed
S&F in replacement of Switch socket combination 15 Amps complete all as specified and directed
M&L for Sub main wiring complete with 2 x 1.5 sqmm , single core , multi stranded copper conductor FR PVC insulated and sheathed cable 1100 Volts grade , drawn in PVC Casing Capping in surface /PVC conduit in concealed/surface (as required) along walls roofs etc including 1.5 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed Note:- (i) All three wire/cable(phase, neutral and earth) should be run through for each individual circuit from the DBs. (ii) Three run of cable and one run of conduit shall be measured as one unit
All as per Srl item No 17 above but 2 x 2.5 Sqmm and 1 x 2.5 Sqmm for earth wire
All as per Srl item No 17 above but 2 x 4 Sqmm and 1 x 4 Sqmm for earth wire
All as per Srl item No 17 above but 2 x 6 Sqmm and 1 x 6 Sqmm for earth wire
S&F in replacement of PVC Gang box with 5/15 Amp multipurpose Switch and Socket complete all as specified and directed
All as per item No 18 above but but 5 Amps, 5 Pin complete all as specified and as directed
S&F in replacement MCB DP 32 Amps, 240 Volts, 10 KA, 'C' Curve complete all as specified and directed
S&F in replacement MCB DP 40 Amps, 240 Volts, 10 KA, 'C' Curve complete all as specified and directed
S&F in replacement MCB TP 40 to 63 Amps, 240 Volts, 10 KA, 'C' Curve complete all as specified and directed.
Taking down old / Unserviceable DB by disconnecting electric connection carefully SPN DBs, Main Switch including old models load star MCBs, Isolators,etc and making good to disturbed surface all as specified and directed
Taking down Old Unserviceable DBs TPN / Main Switches including old models load star MCBs, isolators, fuses,etc and making good to disturbed surface all as specified and directed
S&F load line vertical DB TPN 4 way IP 43 IK-09 with metal double door suitable for provision of MCCB , 36 KA, 100 Amp for housing of MCBs complete all as directed
S&F double door DB SPN 4 way IP 43-IK-09 with metal double door suitable for housing of MCBs complete all as specified and as directed
S&F double door DB SPN 8 way IP 43-IK-09 with metal double door suitable for housing of MCBs complete all as specified and as directed
S&F in replacement MCCB 415 V, 160 Amps, 36 KA, 3 Pole with thimbles / lugs and nut,bolts complete all as specified and as directed
S&F in replacement MCB TPN 6 to 32 Amps, 440 Volts, 10 kA, 'C' Curve complete all as specified and directed
S&F in replacement MCB TPN 40 to 63 Amps, 440 Volts, 10 kA, 'C' Curve complete all as specified and directed
S&F in replacement MCB Four Pole 100 Amps, 440 Volts, 10 kA, 'C' Curve complete all as specified and directed
S&F in replacement MCB SP 6 to 32 Amps, 440 Volts, 10 kA, 'C' Curve complete all as specified and directed
S&F in replacement MCB SP 40 to 63 Amps, 440 Volts, 10 kA, 'C' Curve complete all as specified and directed
S & F in replacement LED tube light fitting, 1x18 w, 230v surface / wall mounted LED batten, 2100 lm PC Body tube housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver. & connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed
S & F in replacement of LED tube light fitting, 1x20W, 230v surface / wall mounted LED batten, elegant dia cast for designer homes bright LED source with uniform light out put , 2400 lm , surge protection of 2 KV with wide voltage protection 160-360 V in provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver. & connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed
S & F in replacement LED mirror light fittings 1x12W, 230v Helios type fitted on wall/surface complete all as specified and directed.
S & F in replacement LED light fitting, 1x33 W, 230v, 2'x2' recessed mounted general purpose squre shaped luminaries with high transitivity diffuser suitable for office application with profiled & flat diffuser fitted on ceiling connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed
S & F in replacement LED security light fitting, 15w, 230v down light recessed mounted general purpose square/round shaped luminaries with high transitivity diffuser with profiled & flat diffuser fitted on ceiling connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed
M&L for taking down unsv ceiling fan and rewinding the ceiling fan of 1200 mm sweep complete with super enameled copper wire of required size duly varnished with high quality varnish and testing complete all as specified and as directed
All as per item No 38 above but 1400 mm sweep.
M&L for taking down unserviciable exhaust fan and rewinding the exhaust fan with super enameled copper wire of required size covered with high quality varnish complete of 300 mm sweep including greasing /oiling and testing complete all as specified and as directed
M&L for taking down unserviciable cabin fan / wall mounted fan and rewinding the same with supper enameled copper wire of required size covered with high quality varnish complete including greasing /oiling and testing and refixing the same complete all as specified and directed
S&F in replacement bearing of ceiling fans 1200/1400 mm sweep for proper running and testing complete all as specified and as directed
S&F in replacement Gun metal bushes for ceiling fans of size 1200/1400 mm sweep including oiling and testing for proper running complete all as specified and directed
S&F in replacement rotor shaft of ceiling fans of size 1200 mm sweep complete all as specified and directed
All as per item No 44 above but 1400 mm sweep
S&F in replacement ceiling fan startor for 1200 mm sweep match to existing fan rotor complete all as specified and as directed
All as per item No 46 above but 1400 mm sweep
M&L for Painting to ceiling fans of any size with two coats of synthetic enamel paint by means of suitable spray gun after cleaning and preparing the surfaces and marking the circular ring line 3 mm thick line with golden colour on bottom centre all as specified and directed
M&L for Painting to Exhaust fan of any size / air circulators with two coats of synthetic enamel paint after cleaning and preparing the the surface complete all as specified and as directed.
M&L for Painting to Wall mounted / Cabin Fans with two coats of synthetic enamel paint by means of suitable spray gun after cleaning and preparing the surfaces and marking the circular ring line 3 mm thick line with golden colour on bottom centre complete all as specified and as directed
S&F in replacement Exhaust fan single phase 1400 RPM, 300mm sweep heavy duty complete with louver shutter and incl fixing water proof ply wood 12 mm thick of size 350X350mm for fan base after cutting 300 mm dia of suitable size all as specified and directed Note : Old unsv fan shall be deposited to MES store.
S&F in replacement ventilating fan 200 mm sweep 230Volt AC with sturdy blades fully plastic body complete sound proof incl fixing water proof ply wood 12 mm thick of size 300X300 mm for fan base after cutting 200 mm dia of suitable size all as specified and directed Note : Old unsv fan shall be deposited to MES store.
S&F in replacment Wall mounted fan, 450mm sweep, single phase, 230 volts, 50 Hz, including fixing on wall with fan clamp/hook, connecting electricallycomplete all as specified and as directed Note : Old unsv fan shall be deposited to MES store.
S&F in replacement Ceiling Fan 1200 mm sweep single phase AC Energy saving complete as per manufacturer specification all as specified and directed Note : Old unsv fan shall be deposited to MES store.
S&F in in replacement Bracket assembly of various sizes as required for hanging ceiling fan with rubber shackle nuts, bolts and split pin all as specified and directed
S&F in replacement Condenser 2.5 mfd including fixing of clamps with screws, sleeves etc complete all as specified and directed
S&F in replacement Ceiling fan blades as per existing pattern (set of three) for 1200 sweep complete all as specified and directed
All as per item No 57 above but 1400 mm sweep
S&F in replacement Fan regulator step type electronic 250 Volt complete all as specified and directed.
S&F in replacement down rod of ceiling fan made up to 1 mtr long MS pipe medium grade including two coats of synthetic enamel paint over a coat of red oxide primer with bolts / check nuts, washers etc as per existing size and shape of fans incl new U hook with rubber reel with nut bolt and washer including drilling, threading complete all as specified and directed
S&F in replacement canopy (set of two) for ceiling fans 1200 mm /1400 mm sweep complete all as specified and directed
S&F in replacement ceiling fan bottom cover suitable for 1200/1400 mm sweep with existing make and model complete all as specified and directed
S&F in replacement of ceiling fan Top cover suitable for 1200/1400 mm sweep with existing make and model complete all as specified.
S&F in replacement Exhaust fan blade as per existing make and model of size 300 mm sweep complete all as specified and directed
S&F in replacement heating element suitbale for geyser of capacity 25 Ltrs / 50 Ltrs as per existing model complete all as specified and as directed
S&F in replacement thermostat suitbale for geyser of capacity 25 Ltrs / 50 Ltrs as per existing model complete all as specified and as directed
S&F in replacement Geyser (Heater water storage type) 50 Ltr Capacity, 240 V energy saving 5 star rating and all features as per manufacturer's specification including installation complete all as specified and as directed
S&F in replacement Geyser (Heater water storage type) 25 Ltr Capacity, 240 V energy saving 5 star rating and all features as per manufacturer's specification including installation complete all as specified and as directed
S&F in replacement chrominium plated stop cock screwed of size 15 mm dia complete all as specified and directed
S&F in replacement Bib cock brass screwed down for size 15 mm bore all as specified and directed
S&F in replacement of GI medium grade pipe of 15mm bore complete including all fitting complete all as specified and directed.
S&F in replacement of PVC connection for geysers of 15 mm size heavy duty 450 mm long with brass nuts, bolts and washers all as specified and directed.
S&F in replacement of PVC connection for geysers of 15 mm size heavy duty 650 mm long with brass nuts, bolts and washers all as specified and directed.
M&L for earthing complete with Galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mir deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized earth strip 32x6 mm size connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 15 mm dia GI pipe medium grade for protection of G1 earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I. Note: (i) Cost of GI earth wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returninng & filling, PCC chamber pit, RCC cover & test point.(iii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit. (iv) All accessories required for galvanised steel plate electrode required, as specified and as directed.
Taking down geysers of any type & make after disconnecting the electric supply and water connections plugging the inlet and outlet as required in the building , taking out the copper or steel container ,carefully from the geyser, descaling rectifying leakage by bracing ,repairing the insulating (glass wool) metal ,testing for the required pressure and replacing rubber gaskets with new ones appying one coat of approved paint and refixing the same in position with nuts and washers complete complete all as specified and as directed
S&F in replacement LED Lamp 9W 220V, 50HZ complete all as specified and directed.
S&F in replacement LED lamp 12W 220V, 50HZ complete all as specified and directed.
S&F in replacement Modular switch one way 6A, 220V 50Hz , one module complete all as specified and as directed
S&F in replacement Modular switch oneway 16A, 220V 50Hz, one module complete complete all as specified and as directed
S&F in replacement Modular switch two way 6A, 220V 50Hz, on module complete all as specified and as directed
S&F in replacement Modular bell push 6A, 220V 50Hz one module complete all as directed at site.
S&F in replacement Socket, 6A - 2/3 pin combined ,220V 50Hz two module complete all as specified and as directed
S&F in replacement socket 16A - 2/3 pin combined ,220V 50Hz two module complete all as specified and as directed
S&F in replacement fan regulator, step type , 120W - 1/2 module ,220V 50Hz complete all as specified and as directed
S&F in replacement White cover plate with frame, one module complete all as specified and as directed
S&F in replacement White cover plate with frame, two module complete all as specified and as directed
S&F in replacement White cover plate with frame, three module complete all as specified and as directed
S&F in replacement White cover plate with frame, four module complete all as specified and as directed
S&F in replacement White cover plate with frame, six module complete all as specified and as directed
S&F in replacement metal flux box one or two module complete all as specified and as directed
S&F in replacement metal flux box four module complete all as specified and as directed
S&F in replacement metal flux box six module complete all as specified and as directed
S&F in replacement Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittingscomplete all as specified and as directed
Attending day to day Street light complaints (Street lights fitted on poles/buildings at heights up to 12 mtr from ground level), repair/replacement of unserviceable accessories like lamps,lamp holders, ballast, ignitor, capacitors, reflectors, acrylic covers, nuts, bolts, clamps ets and repair/replacement of U/S connected accesories like cables, wires, earthing strip, earth wire, feeder piller box including replacing all accessories such as MCB, MCCB's bus bars, HRC fuses, rewirable fuses, contactor, timers, connector, wires, glands, thimbles etc sunday and holidays as when required including all required tools, ladders, labour and all other incidental operations required for execution of maintenance work are included complete all as directed and specifed. Note: -(a) Cost for taking down and re-fixing new parts shall be deemed to be included in the unit rate quoted. (b) All the fitting of HPSV/MVL/HPL/Halogen and flood light will be cleaned once in a month or when required. The rate for which shall be deemed to be included in this item (c) Contractor is responsible to carrying out routine and preventive maintenance as per relevant IS code and as per IS 1944 (part I &II) 1970 code of practice for lightning.
Note for item No 94 above :- (a) Spares and accessories will be measured and paid separately under relavant items. (b) The break down complaint shall be attended within 2 hours after the intimation of Engr-in-charge or concern JE E/M by telephonically / verbally / by writing (c) Not attending of complaint within two hours after intimation shall lead to recovery from subsequent payment in the following manner :- (i) Attending within 2 to 4 Hours - Rs. 2000.00/complaint. (ii) Attending within 4 to 6 Hours- Rs. 4000.00/complaint (iii) Attending within 6 to 8 Hours- Rs. 8000.00/complaint (iv) Attending after 8 Hours - Rs. 10,000.00/complaint (v) The maximum recovery will be Rs. 50,000.00 plus the expenditure incurred for rectification of the same by any other means.
Excavation in trenches in soft/loose soil, n exc 1.5m wide and n.exc 1.5m in depth for foundation etc or for shafts, wells, cessapits, manholes, pier holes, etc n exc 10 Sqm on plan and getting out all as specified and directed
All as per item No 95 above but exc 1.5m in depth
Excavating in trenches in hard/dense soil, n exc 1.5m wide and n.exc 1.5m in depth for foundation etc or for shafts, wells, cessapits, manholes, pier holes, etc n exc 10 Sqm on plan and getting out all as specified and directed
Returning, filling in using excavated soil, including spreading, levelling watering and well ramming in layers n.exc 25cm all as specified and directed.
Removing surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above starting point in any type of soil oomplete all as specified and as directed
M&L for boring of holes under road/pavement/hard standing or any other situation by manual mean for passing GI pipe 50mm bore grade and making good both the ends all as specified and directed Note: - Cost of GI pipe shall be measured and paid separately unde relevent item of this schedule
Cutting of existing road/hard standing for laying cables/pipe including making good the disturbed surface to match with the adjoining surfaces with PCC 1:3:6 type C2 using 40mm graded stone aggregate all as complete and specified
S&F in replacement GI pipe light grade 40 mm dia for cable protection on road crossings /plinth protection or fixed to the pole/ wall etc for cable protection including fixing accessories complete all as specified and as directed .
Demolition of cement concrete in ground floors and paving built in cement concrete (unreinforced) n.exc 15 cm thickness (below or above ground level) complete all as specified and as directed
M&L for PCC 1:2:4 type B-2 using 40mm grade stone aggregate as in coping of poles including necessary form work and fair finshing to exposed surface without using extra cement complete all as specified and as directed
M&L for PCC 1:3:6 type C-2 using 40mm grade stone aggregate as in foundation for stay assy, repairing of floor/paths, fencing post road cutsetc including necessary form work and fair finshing to exposed surface without using extra cement complete all as specified and as directed
Supply, laying and jointing in replacement , in trenches / passing through pipes/ fixing on poles/fixing on wall with saddles in replacement LT under ground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm, 4 core including including cable connecting lugs, glands, jointing fixing complete all as specified and as directed
All as per item no 106 above but 25 Sqmm 4 core
All as per item no 106 above but 35 Sqmm 3.5core
All as per item no 106 above but 50 Sqmm 3.5core
Supply & laying in replacement DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure under ground cable complete all as secified and directed
All as per item No 110 above but outer dia of 63 mm and inner dia 50 mm.
All as per item No 110 above but outer dia of 77 mm and inner dia 63 mm.
S&F 2.5 Sqmm, single core Two runs PVC insulated and unsheathed FR cable 1100 Volts grade with multistranded copper conductor and one run of 2.5 Sqmm cable for common earth dolly drawn through street light pole including connection from kiosk box to street light fittings all as specified and directed
S&F 1100 volts grade heavy duty cable with PVC insulated, stranded aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart or fixing on wall with saddeles and screws all as directed and as per site requirement, of size 6 sqmm, twin core flat or circular complete all as specified and as directed
M&L for prepration of old street light poles by scraping, cleaning of old surfaces of the existing street light tubular poles of size upto 11 mtr long above ground level including brakcets, arches and sodium/mercury vapour light fittings of any shape and painting with two coats of aluminium paint including marking 30 cm strips on pole in black and yellow colour paint upto 2.1 mtr ht from the pedestal including write number on pole as specified and directed
S&F in replacement of Junction box IP 65 / IP 66 Thermoplastic Polycarbonate Cable Junction boxes for Intrinsic Fire resistance and insulating Integrity (with Terminals) (From 1.5 Sqmm upto 25 Sqmm Cable conductors) made of PC-GFS of size 200mm x 160mm x 98mm and fixing on pole with 32x6 mm aluminium strip clamp with nuts, bolts and washers , electrical connections all as directed by Engr-in -Charge.
S&F in replacement service bracket for street light fitting made out of 40 mm bore light graded GI pipe of length 1.50 mtr bend/weld to shape at 120 degree for fixing of street light fitting on pole all as specified and as directed by the Engineer-in-charge. Note: - Cost of MS clamp, nuts, bolts and washers shall be inclusive of this item
Supply only in repairs following items (against item No 94 here in before): -
HPSV / MH ballast 150watt.
HPSV/MH ballast 250watt .
Electronic ballast 36 W
Super imposed ignitor for SON/MH light fitting
Capacitor 20 MFD, 230 volts.
Lamp holder porcelain threaded type for single ended lamp 70/150 watt SV/MH lamp.
Lamp holder for retrofit T-5/8/12 TL 14/24/36 watt
Lamp 150 Watt tubular
Lamp 250 Watt tubular
MCB SP 06 to 32 Amp 10 KA, 'C' curve 230 .
MCCB TP 125 Amp, 36KA 4Pole.
MCB DP 63 Amp 10 KA, 'C' curve 230 Volt .
MCB TP 63 Amp 10 KA, 'C' curve 230 Volt .
S&F in replacement of Street light fitting LED type, 25 Watts 240 Volts luminous efficiency not less than 100 lm/Watt , and accessories complete mounted on suitable dia light grade GI pipe bracket 1.0 mtr long bent to shape, mounted on wall and providing connection complete all as specified and directed
S&F in replacement of Street light fitting LED type, 45 Watts 240 Volts luminous efficiency not less than 100 lm/Watt , and accessories complete mounted on suitable dia light grade GI pipe bracket 1.0 mtr long bent to shape, mounted on wall and providing connection complete all as specified and directed
S&F in replacement of Street light fitting LED type, 72 Watts 240 Volts high luminous, energy efficient not less than 100 lm/Watt , including SPD fittings and accessories complete mounted on suitable dia light grade GI pipe bracket 1.0 mtr long bent to shape, mounted on wall and providing connection complete all as specified and directed
S&F in replacement of Street light fitting LED type, 100 Watts 240 Volts high luminous , energy efficient not less than 100 lm/Watt , including SPD fittings and accessories complete mounted on suitable dia light grade GI pipe bracket 1.0 mtr long bent to shape, mounted on wall and providing connection complete all as specified and directed
S&F in replacement of Street light fitting LED type, 120 Watts 240 Volts high luminous not less than 100 lm/Watt , energy efficient , including SPD fittings and accessories complete mounted on suitable dia light grade GI pipe bracket 1.0 mtr long bent to shape, mounted on wall and providing connection complete all as specified and directed by Engr-in-Charge
S&F in replacement of smart bright Flood light fitting LED type, 120 Watts 240 Volts luminous efficiency not less than 100 lm/Watt , PDC housing with IP 65 flood light sleek and robust design for better aesthetics, reliable and sturdy, mounted on wall and providing connection complete all as specified and directed
S&F in replacement of smart bright Flood light fitting LED type, 200 Watts 240 Volts luminous efficiency not less than 100 lm/Watt , PDC housing with IP 65 flood light sleek and robust design for better aesthetics , reliable and sturdy, mounted on wall and providing connection complete all as specified and directed
S&F in replacement energy efficient post top light fitting on wall/gate 360 digree indirect light with IP 65 protection high quality integerated LEDs assuring soothing warm white light all night long LED 40 W black case aluminuim including all necessary wiring LED bulb , clamps, nut and bolts mounting acessories etc and providing connection all as specified and directed
S&F in replacment energy efficient post light (bollard light) 360 digree light distribution with IP-65 ,85.5 cm hight and 17.4 cm width fitting on ground , wall etc including excavation and PCC 300cmx300cm and high quality integerated LEDs assure soothing warm white light all night long LED 10 W black case aluminuim , synthetic model Robin including all necessary wiring LED bulb , clamps, nut and bolts mounting acessories etc all as specified and directed
S&F in replacement LED emergency tube tube light fittings 1x20 W, 2000 lumen, 230V, 4 feet fitted on wall / surface with back up time 1.5 to 2 hours complete all as specified and directed.
ICON AGENCIES
AMR TRADERS
M/s Sai Electrical Works
M/s G K Construction
M/s Pooja Enterprises
M/S ISLAND REALCON INDIA PVT. LTD
M/s Power Engineering Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .