Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹85.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹1.1 Cr+₹19.7 L (23.0%)Rejected-AOC | L2 | Rejected-AOC Being Not L1 | |
| 3 | L3₹1.2 Cr+₹38.5 L (44.9%)Rejected-AOC | L3 | Rejected-AOC Being Not L1 |
Tender Value
Refer Docs
EMD Value
₹1.6 L
Closing Date
13 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col PS Chand, CWE
CWE, Port Blair Minniebay, Junglighat (Post) Port Blair- 744 103
CONSTRUCTION OF WATCH TOWER WITH FOCUS LIGHT AT BVY (PBR), PORT BLAIR
2021_MES_447357_1
CONSTRN OF WATCH TOWER WITH FOCUS LIGHT AT BVY PBR
Open Tender
Civil Works
Lump-sum
270 days
PORT BLAIR
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GARRISON ENGINEER (P) NORTH
₹1.6 L
Yes
28 Jul 2021
1 Jun 2021
19 Jul 2021
1 Jun 2021
13 Jul 2021
29 Jun 2021
60 days
Amount
SCHEDUEL 'A' PART- I TO X NOTES: Schedule ‘A’ Part- I to X are prepriced by MES under Ser No. 1.00 to 10.00. Bidders shall insert their lump sum amount in the Green coloured field under Col-6 only.
Lump sum price worked out by the tenderer for "Building/Structures" as listed in Schedule 'A' Part-I
Lump sum price worked out by the tenderer for "Excavation, Earth work, site clearance and Land Development" as listed in Schedule 'A' Part-II
Lump sum price worked out by the tenderer for "Internal Water Supply" as listed in Schedule ‘A’ Part-III
Lump sum price worked out by the tenderer for "Internal Electrification" as listed in Schedule ‘A’ Part-IV
Lump sum price worked out by the tenderer for "External Water Supply" as listed in Schedule ‘A’ Part-V
Lump sum price worked out by the tenderer for "External Electric Supply" as listed in Schedule ‘A’ Part-VI
Lump sum price worked out by the tenderer for "Roads, Path and Culvert" as listed in Schedule ‘A’ Part-VII
Lump sum price worked out by the tenderer for "Retaining wall" as listed in Schedule ‘A’ Part-VIII
Lump sum price worked out by the tenderer for "Sewage Disposal" as listed in Schedule ‘A’ Part-IX
Lump sum price worked out by the tenderer for "AREA DRAINAGE" as listed in Schedule ‘A’ Part-X
Subtotal
NOTE: Schedule ‘A’ Part - XI is not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-6.
SCHEDULE `A' PART - XI (MISC ITEMS)
Internal Electric Supply
Supply and fix Coaxial TV cable, RG-6 with less signal losses Make: Havells, Cat no:WHOJTTKARG06 or equiv in Finolex
Supply and fix TV coaxial socket,1 module all as directed. Make:Havells,Cat No:AHLKTOG001or equiv in Havells
S&F ultra slim elegance LED lighting fixture with extruded Aluminium housing fo heat dessipation,integrated electronic driver, 10 watts ,5700K(2ft) Energy Efficient and environmental friendly, all as directed by the engg-in-charge. Make : Havells, or equiv of Wipro/Philips/Crompton
S&F ultra slim elegance LED lighting fixture with high efficacy ,20w,5700K (4ft) with Aluminium housing all as directed by the engg-in-charge. Make : Havells, or equiv of Philips/Crompton
Supply and fix fan exhaust of sweep 250mm, pace type, single phase with their all accessories fixed properly on wall surfaces including connecting/testing complete as directed. Make: Havells, Code: Venti Air-DX-White or equivalent in Usha/Almonard
Supply and fix ceiling fan 1200mm sweep,5 star rated ,230V, complete including all accessories. Make: Havells, Cat no: ES-40 or equivalent in Bajaj
Supply and Fixing Sheet metal enclosure for DBs when MCBs to be Used, 8way, double door SP & N, 240 Volt. Make-Havells or equvalent in Standard/L&T/Indo Asian.
Supply and Fixing Miniature circuit Breakers, single pole,B-Series 240 Volts of capacity (6-32 Amps) as ordered breaking capacity 10 KA. Make-Havells or equvalent in Standard/L&T/Indo Asian.
Supply and Fixing Miniature circuit Breakers, SP&N, C-Series 240 Volts of capacity (6-32 Amps) as ordered breaking capacity 10 KA. Make-Havells or equvalent in Standard/L&T/Indo Asian.
M&L for earthing complete with galvanized steel plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25mtrs deep below ground level) with top edge of plate not less than 1.5mtrs below normal ground level, connected to GI earth wire 4sqmm by means of bolts,nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 connected to earthing test point on completion with and including 15mm bore light grade GI protection pipe (7.5mtr long) for earth including PCC (1:2:4) type B1 chamber pit with pre cast RCC(1:2:4) type B1, 40mm thick reinforced with steel wire 6 mm dia MS bars @ 100 c/c both way lifting hooks made out of 6 mm dia MS bars, watering arrangement with funnel, wire, common salt, charcoal filling, necessary excavation and earth work in any type of soil complete all as specified including taking out the existing u/s earthing accessories. Note: If necessary earth resistance value is not obtained after testing the conractor should do fresh earthing free of cost.
External Water Supply
M&L for Construction of masonry valve chamber of size 600X600X600 mm internal size, 100 mm thick foundation using PCC 1:4:8, type D-2, over 15cm thick hard core, 20cm thick solid block masonry with blocks cast using PCC 1:3:6, type C-1, set in cement mortar 1:4, 15MM thick plaster to internal surfaces and external surfaces up to 15cm below ground level and top of floor in cement and sand mortar 1:4, finished even and smooth with out using extra cement , 3.15mm thick MS sheet cover including 50mmX50mmX6mm thick MS angle frame fixed in PCC 1:2:4, type B1 coping with 25mmX6mm flat iron hold fasts, handle, hinges with locking arrangements, applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces and earth work in any type of soil including disposal of surplus soil to a distance not exceeding 50M complete all as specified and directed.
M & L for making bore in existing CI pipe line of size 100 mm and including threading for making branch connection for 50 mm including suitable barrel nipples, union and all acessories etc as directed
M&L for cutting existing road/hard standing not exc 45x60 cm in wide & depth getting out excavated material for laying GI tube ;returning filling & well rammaing watering finish suraface 15 cm from top using PCC 1:3:6; including removal of surplase soil all as directed
External Electric Supply
S & F MCB TPN 20 Amps, 10 KA, 230 Volts including din rail for fixing in existing panel, providing 4 Sqmm copper wire wire from Bus bar to MCB with lugs
Supply and fix in replacement flood light fittings in street light poles/Buildings the fitting shall be of LED type 120 Watts complete with and including drivers, pressure die cast aluminium housing, prewired complete in including additional brackets made of angle iron of size 45mm X 45mm X 5 mm for mounting the fiting in Watch Towers. The fitting shalll conform to cat No -LFLN-120-CDL/60 of Crompton or Equivalent from Philips/Bajaj
S & Fix 1 module telephone socket with shutter including surface type plastic box
Subtotal
AMR TRADERS
ACME Consultants
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .