Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹1.9 L
Closing Date
15 Dec 2025, 2:00 pmClosed
State Project Director
ARIAS Society, Agriculture complex, Khanapara, G.S Road, Ghy- 781022
Conservation, Restoration and Rejuvenation works of the Param Beel of Majuli District under Assam SWIFT Project
2025_FEAP_48656_1
ARIAS /ADB-SWIFT/CW10-08
Open Tender
Civil Works
365 days
Ujoni Majuli
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,890
₹1.9 L
Yes
ARIAS Society, Agriculture complex, Khanapara
6 Mar 2026
17 Nov 2025
15 Dec 2025
17 Nov 2025
15 Dec 2025
8 Dec 2025
17 Nov 2025 - 6 Dec 2025
1 Dec 2025
DE-WEEDING: Clearance of different types and nature of Water Hyacinth, Aquatic weeds, Taranies, Dalanies, Pitanies, repeated vegetation etc. from Beels/ Tanks/ Ponds/ swampy and marshy areas dragging manually /mechanically/ through machinery etc. with necessary ropes, bamboos, chains and other debries devices etc. making patches, cutting into pieces with the help of knifes/ sickles/ sews as necessary and depositing and stocking in the marginal areas of the beels/ tanks/ ponds/ swampy and marshy areas in a regular form of bundhs or heaps within a lead of 100 m and lift up to 2.50 m as per direction of the deptt. etc complete (pushing out the patches or pieces of vegetations may also be made through the connecting channels with the river and burning the lifted vegetation after sunshine as and when applicable). i) Thin and floating water hyacinths and other aquatic weeds etc.
DE-WEEDING: Clearance of different types and nature of Water Hyacinth, Aquatic weeds, Taranies, Dalanies, Pitanies, repeated vegetation etc. from Beels/ Tanks/ Ponds/ swampy and marshy areas dragging manually /mechanically/ through machinery etc. with necessary ropes, bamboos, chains and other debries devices etc. making patches, cutting into pieces with the help of knifes/ sickles/ sews as necessary and depositing and stocking in the marginal areas of the beels/ tanks/ ponds/ swampy and marshy areas in a regular form of bundhs or heaps within a lead of 100 m and lift up to 2.50 m as per direction of the deptt. etc complete (pushing out the patches or pieces of vegetations may also be made through the connecting channels with the river and burning the lifted vegetation after sunshine as and when applicable). ii) Thick and floating water hyacinths and other aquatic weeds etc.
DE-WEEDING: Clearance of different types and nature of Water Hyacinth, Aquatic weeds, Taranies, Dalanies, Pitanies, repeated vegetation etc. from Beels/ Tanks/ Ponds/ swampy and marshy areas dragging manually /mechanically/ through machinery etc. with necessary ropes, bamboos, chains and other debries devices etc. making patches, cutting into pieces with the help of knifes/ sickles/ sews as necessary and depositing and stocking in the marginal areas of the beels/ tanks/ ponds/ swampy and marshy areas in a regular form of bundhs or heaps within a lead of 100 m and lift up to 2.50 m as per direction of the deptt. etc complete (pushing out the patches or pieces of vegetations may also be made through the connecting channels with the river and burning the lifted vegetation after sunshine as and when applicable). iii) Thick and floating Taranies,Dalanies, Pitanies and other marginal aquatic weeds etc. upto a depth of 50 cm.
DE-WEEDING: Clearance of different types and nature of Water Hyacinth, Aquatic weeds, Taranies, Dalanies, Pitanies, repeated vegetation etc. from Beels/ Tanks/ Ponds/ swampy and marshy areas dragging manually /mechanically/ through machinery etc. with necessary ropes, bamboos, chains and other debries devices etc. making patches, cutting into pieces with the help of knifes/ sickles/ sews as necessary and depositing and stocking in the marginal areas of the beels/ tanks/ ponds/ swampy and marshy areas in a regular form of bundhs or heaps within a lead of 100 m and lift up to 2.50 m as per direction of the deptt. etc complete (pushing out the patches or pieces of vegetations may also be made through the connecting channels with the river and burning the lifted vegetation after sunshine as and when applicable). iv) Medium and floating Taranies,Dalanies, Pitanies and other marginal aquatic weeds etc. upto a depth of 50 cm to 80 cm
DE-SILTING & EXCAVATION: Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead from the beds of Beels/Tanks/ Ponds/ Swampy lands to the proper grade and slopes as required and utilizing the soil in construction of embankment or repairing of existing embankment on all sides, lifting in uniform layers not exceeding 20 cm thick (excluding compaction), clearing light jungles and trees up to 50 cm girth from the site of work, dug belling, profiling, ploughing or roughening or benching the seat, breaking clods up to 25 mm cube ramming, removing roots and vegetation, dressing to the designed section complete as directed. All kind of soil. Construction of Pheripheral Bund with de-silted soil Construction of Rearing Tank bund with de-silted soil
TURFING: Furnishing and laying of live sods of perennial turf-forming grass on embankment slopes, verges, or other locations as shown on the drawings or as directed by the Engineer, including preparation of ground, stacking the sods, and watering, as per Clause 309.
EARTHWORK IN EXCAVATION: Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Ordinary soil Upto 3 m depth For HP Culvert
PLAIN/ REINFORCEMENT CONCRETE: Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 I. With crushed Stone A.P.C.C grade M 10 i.Nominal mix 1:3:6 For HP Culvert
BEDDING FOR PIPE: Bedding of pipe (ii) Type B(First Class) Bedding Laying (FirstClass)bedding on well compacted approved granular material as per Clause 1105 (ii) (i) Sand Filling For HP Culvert
BRICK MASONRY WORK: Brick masonry work in cement mortar in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 600, 1202 & 1203 i) Brick masonry in 1:4 cement mortar For HPC head wall
CEMENT MORTAR: Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204 For HPC head wall
NP3 PIPE: Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. (B) 1000 mm dia
PLAIN/REINFORCED CEMENT CONCRETE: Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204 RCC Grade M20 For height upto 5m
STEEL REINFORCEMENT: Supplying, fitting and placing TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-550N/sqmm (Fe-550D) from Primary Producer(TATA/SAIL/Esser Steel/Jindal steel/Shyam steel/RINL) in superstructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202.
PEN CULTURE Construction of Pen Culture with Bamboo (1st Class) 85 mm - 100 mm dia, 4.5 m - 5.5 m long, vertically placed at 2.00 m centre to centre driven 1.50 m below ground/bed level and 2.50 m above ground/bed level tied with Jati or Bethua bamboo 50mm to 100 mm dia and 6m long above groung level horizontally in two rows at 2.00 m apart, Fencing with split bamboo kamis in horizontal direction at 300 mm c/c and vertical direction at 800 mm c/c having tied with coconut fiber two poly twisted rope etc. manually with provision of hired country boat (2 nos.), fitting and fixing of PEN culture Net 115 GSM HDPE mono shade, 45 ply Nylon, 210D, 24 mm mesh size net with boarder rope of 10 mm dia Polypropylene and tie rope in every 2 meter intervals conforming to technical requirement of Textiles - Twisted Nylon Fish-Net Twines as per IS 4401-2006, complete as per drawings and technical specifications as directed by Engineer in-charge. For RearingPen & Stocking Pen
PEN CULTURE Informatory Signboard for which Rs.1400.00 (L/S) is estimated against each signboard
CLEARING AND GRUBBING: Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. i) By Manual Means A) In area of non-thorny jungle For Approach Road
COMPACTING ORIGINAL GROUND: Compacting original ground supporting subgrade Loosening of the ground up to a level of 300 mm below the subgrade level, watered, graded, and compacted in layers to meet requirements of Tables 300.1 and 300.2 for subgrade construction as per Technical Specification Clause 303.5.2. For Approach Road
GSB: Construction of granular sub-base by providing well-graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix-in-place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. ii) For Grading II Material For Approach Road
WBM III: Providing, laying, spreading, and compacting stone aggregates of specific sizes to water-bound macadam specifications, including spreading in a uniform thickness, handpacking, rolling with smooth wheel roller 80- 100kN in stages to proper grade and camber, applying and brooming, stone screening to fill up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. WBM Grading 3 Using stone screening Type-B 11.2 mm for Gr.III For Approach Road
ICBP: Providing and laying interlocking concrete block pavement with M40 grade grade of concrete block, shaving thickness 80 mm as per technical specification clause 1504 complete including carriage. a) Including Edge block/ Edge restraints For Approach Road
EARTHWORK IN EXCAVATION: Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil For Fish Landing cum Community Centre
PLINTH FILLING: Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. Filling up to P. L. For Fish Landing cum Community Centre
PLAIN/ REINFORCEMENT CONCRETE: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) For Fish Landing cum Community Centre
REINFORCED CEMENT CONCRETE WORKS: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) For Fish Landing cum Community Centre
REINFORCED CEMENT CONCRETE WORKS: Reinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) For Fish Landing cum Community Centre
REINFORCED CEMENT CONCRETE WORKS: Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). For Fish Landing cum Community Centre
STEEL REINFORCEMENT: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. For Fish Landing cum Community Centre
SHUTTERING: Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete For Fish Landing cum Community Centre
SHUTTERING: Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams,plinth beams,columns For Fish Landing cum Community Centre
BRICK WORK : Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) For Fish Landing cum Community Centre
PRE CONSTRUCTION ANTI - TERMITE TREATMENT : Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along externa
l wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
PRE CONSTRUCTION ANTI - TERMITE TREATMENT : Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos emulsifiable concentrate of 20%
DAMP PROOF COURSE (DPC): Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
BRICK WORK : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
STRUCTURAL STEEL : Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Side Rail (MS Rectangular Steel Hollow Section Size-40mmX20mmX2mm) (For Fish Landing area)
ROOF TRUSS: Steel work in built up tubular( round, square or rectangular hollow tubes etc.) trusses etc. including cutting , hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction but welded tube
ROOFING: Providing & fixing at all heights, levels and locations Mill finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). 0.56 mm, Aluminium troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm.
ROOFING: Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm)
ROOFING: Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Barge board (Upto 300 mm)
FLOORING: 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
CEMENT PLASTER: 15 mm cement plaster on rough side of single or half brick wall of mix: A) On rough side 1:4 (1 cement: 4 coarse sand)
CEMENT PLASTER: 12 mm cement plaster of mix : B) On fair side - 1:6 (1 cement: 6 fine sand)
CEMENT PLASTER: 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
TILES: Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
TILES: Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed vitrified floor tiles polished finish of size of Tile 1200 x 1200 mm
TILES: Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size of Tile 600 x 600 mm
DOORS AND WINDOWS: Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 60 micron) 1.037kg/m
DOORS AND WINDOWS: Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost
of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
DOORS AND WINDOWS: Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
DOORS AND WINDOWS: 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. 'U' cleats.The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. PVC Door for Toilet
PAINTING: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
PAINTING: Wall painting with premium acrylic emulsion paint of interior grade having VOC (Volatile Organic Compound ) content less than 50 grams/litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
FALSE CEILING: Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks).
SANITARY WORKS: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm dia. nominal bore
SANITARY WORKS: Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore
SANITARY WORKS: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
SANITARY WORKS: Providing and fixing soil, wasteand vent pipes : 100 mm dia. Pipe
SANITARY WORKS: Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete : 100x100x100x100 mm. Sand cast iron S&S as per IS - 1729
SANITARY WORKS: Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
SANITARY WORKS: Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms
SANITARY WORKS: Providing and fixing 100 mm sand cast Iron grating for gully trap
SANITARY WORKS: Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern
SANITARY WORKS: Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore
SANITARY WORKS: Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore
SEPTIC TANK: EARTH WORK: Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge All kinds of soil
SEPTIC TANK: Modular Septic Tank of 5500 Ltrs Capacity, suitable for 10-12 PAX
ELECTRICAL WORKS: Wiring for light point/ fan point/ exhaust fan point/ call bell poin.t with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface I recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
ELECTRICAL WORKS: Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC condu
it alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
ELECTRICAL WORKS: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire
ELECTRICAL WORKS: Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
ELECTRICAL WORKS: Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch
ELECTRICAL WORKS: Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet
ELECTRICAL WORKS: Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet
ELECTRICAL WORKS: Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
ELECTRICAL WORKS: Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
ELECTRICAL WORKS: Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
ELECTRICAL WORKS: LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) < 3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). CRCA Sheet Body (Thickness ≥ 0.50 mm) 18- 22 watt
ELECTRICAL WORKS: Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
EARTH WORK FOR MS ANGLE STAGGING WITH STORAGE TANK: Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge All kinds of soil
MS ANGLE STAGGING WITH STORAGE TANK BRICK WORK : Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. For Stagging Footing
MS ANGLE STAGGING WITH STORAGE TANK STEEL REINFORCEMENT: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
PLAIN/ REINFORCEMENT CONCRETE: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
STRUCTURAL STEEL: Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
WATER STORAGE TANK: Providing and placing on terrace (at all floor levels) polyethylene water storage tank, I
S : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
CENTRIFUGAL PUMP SET: Supplying, installation, fitting & fixing, testing and commissioning of Electric driven 3-phase (for 5HP/ 7.5HP/10HP/12.5HP/15HP) / Single phase (for 1 HP / 2HP / 3 HP pump) Centrifugal pump set of approved make with bronze impeller of suitable diameter with G.I. suction pipe, suction strainer, non-return valve, delivery piping up to sluice valve all complete. The pump set should be coupled with electric motor drive of adequate power suitable for operation at 230V / 415 V, 50 Hz input power with DOL Starter /Star delta Starter including Electric Control panel board enclosure made of MS Sheet duly painted with Anti-corrosive paints complete, fitted with all electrical accessories i.e. Off-On Switch, Voltmeter, Ammeter, Indicator light etc., Complete wiring from Panel Board to Main Line including supply of Aluminium Armoured Cable of adequate cross section, Earthing wire and all necessary materials for the same, including cost of CC pump foundation with base plate complete and other accessories and labour charge for installation of the pump etc. all complete as specified and directed by the Department with One year warranty from the date of commissioning and satisfactory testing against any manufacturing defect. [If any such defect is found during the year from the date of installation and satisfactory testing, supplier will have to rectify the defect at their cost and risk & if necessary replace the pump set.] Test Certificate of Pump, Motor, Starter, Panel Board, etc. from the manufacturer shall have to be submitted: 1 HP of pump (to be provided) Single Phase
SOLAR POWER PLANT: Supply, Installation, Testing and Commissioning of 5KW Off Grid Solar Power plant.
DEMARCATION PILLER: RCC Guard Post:Supplying, fitting and fixing RCC guard post 150cm long erected 75cm above the ground and 75cm below the ground with M-15 grade (nominal mix 1:2:4 with broken stone aggregate up to 20mmsize) of cement concrete and required reinforcement tied in position with an nealed black wire including centering, moulding the top, curing including painting concrete surfaces in 3cm stripsup to0.75m from the to alternately in black and white and having 2 nos. reflective band of desired shade etc complete as per design and as directed. A) 30cmdia.RCCguardpostwithreinforcementof6nos.12mmdiaTMT main steel bars and 6mm TMT/ MS stirrups at 15cm c/c.
SOLAR LAMP: Supply, Installation, Testing and commissioning of a Complete solar street-lighting system, including a 160Wp crystalline silicon solar photovoltaic module supplied with a compatible module mounting structure, clamps, fasteners, and UV-resistant cable tails, with test certification conforming to IEC 61215 (Edition II)/IS 14286 and IEC 61730 from a NABL or IECQ accredited laboratory. The system shall incroporate a Lithium Iron Phosphate (LiFePO4) battery of 12.8V nominal voltage and 42 Ah capacity, equipped with an integrated Battery Management System (BMS) providing protections against over/under-voltage, over-current, short-circuit, over-temperature, and ensuring cell balancing, duly certified to IEC 62133-2011 or the latest BIS standard by a BIS-recognized lab or MNRE-accredited test centre. The MPPT charge controller, integrated with the luminaire and battery, shall operate at 12.8 V noinal, have a maximum current rating of 6A/12 A/14 A as required and provide automatic dusk-to-dawn operation, LiFEPO4 charging profiles, and full electronic protection. The LED street-light luminaire shall be rated at 30W(+5%), with high-effciency optics, a driver compatible with the MPPT output, and ingress protection of IP66 or higher, complying with relevent BIS standards, The system shall be mounted on a 6m long 2.2mm thick tubular hot-dip galvanized GI pole conforming to IS 1161 and IS 4736 complete with a single-arm bracket, MMS, and light arm to hold the luminaire and PV module, along with all necessary clamps and fasteners. The work shall include complte erection on a prepared foundation, all wiring and interconnection, functional testing (dusk-to-dawn operation) in the presence of the Engineer-in-Charge, and submission of as-built documentation. The contractor shall also provide a Comprehensive Maintenance Contract (CMC) for a period of five years from the date of commissioning covering preventive and breakdown maintenance, replacement of defective parts, and maintenance of illuinataion levels as specified.
stage.html
html • 0.03 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
BidDocVol1.pdf
Tender Documents • 2.48 MB
EMPVol2.pdf
Tender Documents • 0.84 MB
DrawingsVol3.pdf
Tender Documents • 9.59 MB
BOQ_77331.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid