Executive Engineer (E) M 253 PWD
Executive Engineer (E)M 253 PWD, Delhi Sachivalaya, New Delhi
RMO of electrical an mechanical installations at Delhi Secretariat, New Delhi during 2025-26. Comprehensive AMC of window, Split, cassette, tower type Air conditioning system and SITC of tower and split type air conditioners in Delhi Sachivalaya
2026_PWD_287894_2
113/EE(E)/PWD M-253/2025-26
Open Tender
Electrical Works
Percentage
365 days
M 253 PWD, Delhi Sachivalaya, New Delhi
Please refer Tender documents.
11 documents required · 11 mandatory
₹0
₹46,417
23 Mar 2026
13 Mar 2026
19 Mar 2026
13 Mar 2026
19 Mar 2026
13 Mar 2026
Select, At Par, Excess (+), Less (-) IOCL
Tender Inviting Authority: Executive Engineer(E) PWD M-253
Name of Work:- RMO of electrical & mechanical installations at Delhi Secretariat, New Delhi during 2025-26. (SH:- Comprehensive AMC of window, Split, cassette, tower type Air conditioning system & SITC of tower and split type air conditioners in Delhi Sachivalaya building)
NIT No.:113/EE(E)/PWD M-253/2025-26 Estimated Cost:-23,20,854/-
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Sub Head Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
1 Comprehensive Annual Maintenance contract and service charges for 1.5/2.0/4.0 TR Split/window/cassette/tower type AC units (i/c inverter & non Inverter technology based AC units) installed at Delhi Sachivalaya Building, New Delhi which includes supply and replacement of components found defective, servicing, repairing, rectification of condenser coil, cooling coil, thermostat relay, PCB, fan motor, electrical wiring, gas charging if found necessary including replacement / repairing of sealed compressors etc. complete as required. For 149 Units in Summer Season Month 38840 374800 Excess(+) Full Conversion INR
2 Comprehensive Annual Maintenance contract and service charges for 11 TR Package/Ductable Air Conditioners installed at Delhi Sachivalaya Building, New Delhi which includes supply and replacement of components found defective, servicing, repairing, rectification of thermostat relay, PCB, fan motor, electrical wiring, gas charging if found necessary including replacement / repairing of sealed compressors, fan motor, PCB, transformer and other electrical parts etc. complete as required. - For 4 Units summer and winter Month 30789 374800 Excess(+) Full Conversion INR
3 TOWER TYPE SPLIT UNITS Supplying, Installation, Testing and Commissioning of Air Cooled Floor standing Tower type split Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5 Mtr (IDU to ODU), copper power cable upto 5.5 Mtr (IDU to ODU), i/c drain pipe of suitable length and size. R-32/R-410/R-407C Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electrotechnical Commission (IEC) 17025 standards / Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS: 1391 as required.Cooling Only 2.4 TR BEE 5 Star Rating each 93613 374800 Excess(+) Full Conversion INR
4 3.8 TR BEE 5 Star Rating each 110025 374800 Excess(+) Full Conversion INR
5 HI - WALL SPLIT SYSTEMS Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, Sble for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only 2.0 TR with 5 Star BEE Rating each 374800 Excess(+) Full Conversion INR
6 Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm mtr 256 374800 Excess(+) Full Conversion INR
7 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm mtr 346 374800 Excess(+) Full Conversion INR
8 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm mtr 739 374800 Excess(+) Full Conversion INR
9 Providing of fixing 4 core 2.5 mm pvc insulated copper wire as main led of AC units i/c connectioning testing as required. mtr 350 374800 Excess(+) Full Conversion INR
10 SITC of flexible plastic drain pipe for various type of A.C mtr 41 374800 Excess(+) Full Conversion INR
11 Less credit for Dismantling materials Assorted tower A.C 2TR nos 374800 Excess(+) Full Conversion INR
12 Assorted tower A.C 2TR nos 6000 374800 Excess(+) Full Conversion INR
13 Assorted split A.C 2TR nos 4000 374800 Excess(+) Full Conversion INR
14 Assorted copper pipe mtr 374800 Excess(+) Full Conversion INR
15 Assorted copper wire mtr 10 374800 Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.10 MB
113.pdf
Tender Documents • 2.11 MB
BOQ_382867.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .