Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 LAccepted-AOC | ₹1.4 L | L1 | Accepted-AOC L1 |
| 2 | L2₹1.5 LRejected-Finance 19 B PANKAJINI CHATTERJEE ROAD KOLKATA 700033 | KOLKATA | KOLKATA | WEST BENGAL | 700033 | ₹1.5 L | L2 | Rejected-Finance L2 |
| 3 | L3₹1.6 LRejected-Finance | ₹1.6 L | L3 | Rejected-Finance L3 |
| 4 | L4₹1.6 LRejected-Finance | ₹1.6 L | L4 | Rejected-Finance L4 |
| 5 | Rejected-Technical | - | - | Rejected-Technical PREMIER OEM COMPANY CERTIFICATE NOT SUBMITTED |
| Sl No | Description | Qty | Unit | BALAJI FIRE PROTECTION SYSTEMS L2 | west bengal fire engineering and emergency protection co. L1 | Fire Shield Engineering & Equipments L3 | EVERSAFE FIRE INDUSTRIES INDIA PRIVATE LIMITED L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Refilling of existing expired Fire Extinguisher
Refilling of Fire Extinguisher 6.0 kg ABC type in conformity with the IS 2190 : 2024 code of practice. It is mandatory to recharge the extinguisher by manufacturer or authorized agent of manufacturer of the existing fire extinguishers brand in conformity with IS 15683 : 2018. Note that the certificates for satisfactory refilling have to be furnished from the manufacturer or its authorized agent at the time of supplying of the refilled fire extinguishers. All other statutory markings/levelling have to be done as per IS-2190 : 2024 code of practice. Extingusihers to be refilled / hydro test for performance test once in 5 years.
A Polyester with 3D hologram label should be pasted on the body of the extinguisher showing
1. Supplied by: PWD
2. Date of refilling:
3. Date of expiry / date of next filling:
4. Refill Identification No/Serial No
5. Brand / rating of Fire Extinguisher to be refilled:
(Existing brand and rating to be mentioned by the Tender Inviting Authority) | 55 | Each | 1,600 ₹88,000 | 1,450 ₹79,750 | 1,750 ₹96,250 | 1,800 ₹99,000 |
| 2.00 | Supply new Fire Extinguisher
Supplying, fixing and Testing of ABC dry powder (Stored Pressure) Fire Extinguisher ISI Marked, of 6 kg. Capacity consisting of Welded cylinder squeeze lever discharge valve fitted with pressure indicating gauge,internal discharge tube, discharge nozzle suspension bracket, with ISI Marked Mono Ammonium Phosphate base (50%) ABC Powder conforming to IS;4308:2019 (W.E.F.16.07.19.) and pressurized with Nitrogen Gas, suitable for operating between -30 degree C to +60 degree C minimum, Fire Rating Class -3A & 89B. The colour of the extinguisher body should be PO Red conforming to shade 538 of IS 5 with Blue Colour Sticker pasted to indicate Power type for easy recognition. The Complete Extinguisher should conform to IS: 15683 : 2018 & should be maintained as per IS:2190:2024 Code of Practice. Extinguishers to be Refilled / Hydro test for performance once in 5 years.
A Polyester with 3D hologram label of OEM(Original Equipment Manufacturer) should be pasted on the body of the extinguisher showing:
1. Supplied by: PWD
2. Date of manufacture:
3. Date of expiry / date of next filling:
4. Serial No:
5. Brand Name:
(Minimax/Ceasefire/Safex/Fire Shield.) | 20 | Each | 3,200 ₹64,000 | 2,850 ₹57,000 | 3,150 ₹63,000 | 3,250 ₹65,000 |
Tender Value
Refer Docs
EMD Value
₹3,000
Closing Date
5 Mar 2026, 2:00 pmClosed
EE_II_KCHD_PWD
P-16, INDIA EXCHANGE PLACE EXTENSION 1st FLOOR, KIT BUILDING, KOLKATA 700 073
Refilling of existing fire extinguishers that have passed hydro test and supply of fire existinguishers at Lumbini Park Mental Hospital during the year 2025-26 .
2026_WBPWD_1009568_1
WBPWD/EEII/KCHD/NIeQ-15/25-26
Open Tender
CIVIL WORKS
10 days
Lumbini park mental hospital
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,000
Yes
17 Jun 2026
18 Feb 2026
9 Mar 2026
24 Feb 2026
5 Mar 2026
24 Feb 2026
Supply new Fire Extinguisher Supplying, fixing and Testing of ABC dry powder (Stored Pressure) Fire Extinguisher ISI Marked, of 6 kg. Capacity consisting of Welded cylinder squeeze lever discharge valve fitted with pressure indicating gauge,internal discharge tube, discharge nozzle suspension bracket, with ISI Marked Mono Ammonium Phosphate base (50%) ABC Powder conforming to IS;4308:2019 (W.E.F.16.07.19.) and pressurized with Nitrogen Gas, suitable for operating between -30 degree C to +60 degree C minimum, Fire Rating Class -3A & 89B. The colour of the extinguisher body should be PO Red conforming to shade 538 of IS 5 with Blue Colour Sticker pasted to indicate Power type for easy recognition. The Complete Extinguisher should conform to IS: 15683 : 2018 & should be maintained as per IS:2190:2024 Code of Practice. Extinguishers to be Refilled / Hydro test for performance once in 5 years. A Polyester with 3D hologram label of OEM(Original Equipment Manufacturer) should be pasted on the body of the extinguisher showing: 1. Supplied by: PWD 2. Date of manufacture: 3. Date of expiry / date of next filling: 4. Serial No: 5. Brand Name: (Minimax/Ceasefire/Safex/Fire Shield.)
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.99 MB
2911.pdf
Tender Documents • 1.86 MB
BOQ_2478530.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid