Loading…
Loading…
Tender ID
Tender Value
₹5.9 L
EMD Value
₹11,900
Closing Date
26 Mar 2026, 5:00 pmClosed
EXECUTIVE ENGINEER
EXECUTIVE ENGINEER PROVINCIAL DIVISION PWD B AND R BR JALANDHAR CANTT
CONVERSION OF ROOM INTO NEW WASHROOM AT COURT ROOM NO. 320 JUDICIAL COURTS COMPLEX JALANDHAR
2026_CEPW_163782_1
Bid No 60 of 13/03/2026
Open Tender
Civil Works - Buildings
Percentage
90 days
JALANDHAR
Please refer Tender documents.
13 documents required · 13 mandatory
₹2,000
₹11,900
Yes
16 Mar 2026
16 Mar 2026
27 Mar 2026
16 Mar 2026
26 Mar 2026
16 Mar 2026
Select, At Par, Excess (+), Less (-) IOCL
Tender Inviting Authority :- EXECUTIVE ENGINEER PROVINCIAL DIVISION PWD B&R JALANDHAR
Name of Work :- DNIT FOR CONVERSION OF ROOM INTO NEW WASHROOM AT COURT ROOM NO. 320 JUDICIAL COURTS COMPLEX JALANDHAR
Contract No: Civil Works
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Work Name Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
1 A1) ADDITION/ ALTERATION WORK OF EXISTING ROOM TO BE CONVERTED INTO NEW WASHROOM 2
2 Dismantling glazed tiles (to be carefully removed). 3 Sqm Excess(+) Full Conversion INR
3 Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading. 4 Sqm Excess(+) Full Conversion INR
4 Extra Rate For 2nd Floor 5 Sqm Excess(+) Full Conversion INR
5 Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by manual means 6 Cum Excess(+) Full Conversion INR
6 Extra for R.C.C/PCC. work done in each subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey. 7 Cum Excess(+) Full Conversion INR
7 First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level 8 Cum Excess(+) Full Conversion INR
8 Extra for work done in additional storey upto 4 metre above the top of structural roof of lower storey for Brick Work/ Concrete Block/ Clay Block. 9 Cum Excess(+) Full Conversion INR
9 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. i With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) size 595x595 mm 10 Sqm Excess(+) Full Conversion INR
10 12.5 mm thick cement plaster 1:5 11 Sqm Excess(+) Full Conversion INR
11 Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish 12 Sqm Excess(+) Full Conversion INR
12 Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade 13 Sqm Excess(+) Full Conversion INR
13 Extra rates for white washing, distempering, painting and decorative cement based paints etc for superstructure Where any single storey height exceeding 4 mtr in height for every additional height of 2 mtr or part thereof (External or Internal) 14 Sqm Excess(+) Full Conversion INR
14 Supply & Fixing of Door Frames ( Chowkhat) Including Mullions Consisting Frame fabricated from Sheet roll Formed Out of 1.2 mm thick galvanized sheet as per IS: 277) base steel as per IS:513) with zinic of 120gm/Sqm powder coated with pure polyester powder upto 50 micrones (as per approved colour), 3 Nos 100 mm butt hinges 2mm thick, 6 Nos 1.2 mm thick CRCA Electroplated Stiffner plate 200mm long reciever for aldrop, M.S tie Rod 50 mm x 25 mm to be fixed bottom finished with powder coating total thickness pf coating 0.60 mm of approved shape, fixed in position including the cost of cement concrete for 1:2:4 for fixing lugs complete in all respects as per design, drawing, specification & Entire Specifications of Engineer-in-Charge. b) Door Frame of Size 125mm x 60mm with 37 mm wide Double Rebate for 35mm door Shutter 15 Metre Excess(+) Full Conversion INR
15 Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : IS 2202-1 (1999): (a) Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- (iv) 35mm thick 16 Sqm Excess(+) Full Conversion INR
16 Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position 17 0.000 Qtl Excess(+) Full Conversion INR
17 Providing Polyester Powder coating 60 to 70 micron any coloured specified to M.S Grill section of various sizes including carriage of material from market to workshop & workshop to site of work. 18 Kg Excess(+) Full Conversion INR
18 Providing and fixing hydraulic door closer ISI mark with necessary screw etc. Complete (c) I.S.I Designation No. III (size of door 851mm to 1000mm) 19 Each Excess(+) Full Conversion INR
19 Providing & fixing 6" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. 20 Each Excess(+) Full Conversion INR
20 Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) ii) For shutter area above 0.50 sqm 21 Sqm Excess(+) Full Conversion INR
21 Providing and Fixing Single Glazing with 6mm thick glass with high perfromance coating as per relevent codal provisions as per satisfaction of Engineer-in-Charge. 22 Sqm Excess(+) Full Conversion INR
22 Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : a) 300mm x 16mm 23 Each Excess(+) Full Conversion INR
23 Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. 24 Sqm Excess(+) Full Conversion INR
24 Providing and applying Anti Termite Treatment using post constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 3 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer's specifications by drilling holes in the floor slab & along skirting 300 mm apart & 12 mm dia, drilling holes along all possible entry points such as junctions of floor and walls, door frames, sewage lines, entry points , etc. & injecting them with the chemical solution. Note :- The Engineer in Charge will ensure consumption of chemical as per manufacturer's specifications & minimum 5 years warranty from the concerned dealer. 25 Ltr Excess(+) Full Conversion INR
25 Renewing glass panes with putty and nails wherever necessary (b) Glass panes weighing 10.75 Kg/sqm 26 Sqm Excess(+) Full Conversion INR
26 B-2) PUBLIC HEALTH 27
27 Sub Head 1 - Sanitary Installation 28
28 Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. 29
29 Chinaware Floor Mounted One Piece EWC rim less type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) size 69x36x74 cm with P trap or S trap and seat cover complete in all respect. 30 Each Excess(+) Full Conversion INR
30 Providing and fixing Stainless steel health faucet complete in all respect. 31 Each Excess(+) Full Conversion INR
31 Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. 32
32 Size 49 cm dia (above counter round) 33 Each Excess(+) Full Conversion INR
33 Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect. 34
34 Note:-To be provided only for VIP Installations and with prior approval of the Engineer-in-charge. 35
35 C.P. Brass Accessories: 36
36 C.P. brass towel rail 600 mm long 37 Each Excess(+) Full Conversion INR
37 C.P brass towel ring square 38 Each Excess(+) Full Conversion INR
38 C.P. brass toilet roll holder with flap 39 Each Excess(+) Full Conversion INR
39 C.P. brass towel rack 600mm long with lower hangers 40 Each Excess(+) Full Conversion INR
40 C.P. brass soap dish holder with glass dish 41 Each Excess(+) Full Conversion INR
41 C.P. Glass Shelf 600mm long 42 Each Excess(+) Full Conversion INR
42 C.P. Brass fittings: 43
43 C.P. brass 3-Hole Basin Mixer Without Popup Waste System 44 Each Excess(+) Full Conversion INR
44 C.P. brass Bib cock with Wall flange 45 Each Excess(+) Full Conversion INR
45 C.P.brass 15mm Angular stop cock with Wall flange 46 Each Excess(+) Full Conversion INR
46 C.P. brass 15mm Concealed stop cock with adjustable wall flange with seal.(Outer +Inner Body) 47 Each Excess(+) Full Conversion INR
47 Providing & Fixing in postion liquid soap container of approved make (to the approval of Engineer-in-charge ) complete in all respect. (A)C.P. brass liquid soap Dispanser 48 Each Excess(+) Full Conversion INR
48 Providing & Fixing in position mirror of superior glass Size 1500mm x600mm or any other required size (of approved quality) and of required shape and size with high quality polystyrene moulding frame of 40 to 50mm size (of approved quality and shade) with 4mm thick hardboard backing fixed in with rawl plugs 50mm, C.P. brass screws and washers complete in all respect 49 sqm Excess(+) Full Conversion INR
49 Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect 50
50 PVC tube connection of size 15 mm x 450 mm with C.P. Brass nut 51 Each Excess(+) Full Conversion INR
51 Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. 52 Each Excess(+) Full Conversion INR
52 Providing and fixing in position C.P. brass bottle trap 32mm dia with 40 mm seal of approved make (to the approval of Engineer- in-charge) complete in all respect. 53 Each Excess(+) Full Conversion INR
53 Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. ii)25mm i/d Brass Ball valves 54 Each Excess(+) Full Conversion INR
54 Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. 55 Each Excess(+) Full Conversion INR
55 Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect. 56
56 i) C.P. Brass extension piece, 25mm long to 50mm long 57 Each Excess(+) Full Conversion INR
57 Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. 58
58 Triple Layer Tanks 59 ltr Excess(+) Full Conversion INR
59 Construction of Platform for HDPE tanks complete in all respect. 60 Each Excess(+) Full Conversion INR
60 Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. 61
61 G.I. tank nipple 25mm i/d 62 Each Excess(+) Full Conversion INR
62 G.I. tank nipple 32mm i/d 63 Each Excess(+) Full Conversion INR
63 Providing and fixing in position automatic brass Ball Cock in tanks. 64
64 Brass Ball Cock with rod and Plastic Ball 65
65 25mm i/d 66 Each Excess(+) Full Conversion INR
66 Prov & Fixing Aluminium door with frame complete in all respect 67 Job Excess(+) Full Conversion INR
67 Sub Head 2 -Internal Water Supply 68
68 CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. 69
69 b) CPVC SDR 11 Pipe & fitting 20mmo/d 70 Mtr Excess(+) Full Conversion INR
70 c) CPVC SDR 11 Pipe & fitting 25mmo/d 71 Mtr Excess(+) Full Conversion INR
71 d) CPVC SDR 11 Pipe & fitting 32mmo/d 72 Mtr Excess(+) Full Conversion INR
72 Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. 73
73 Size 150 mm x 150 mm 74 Mtr Excess(+) Full Conversion INR
74 Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. 75
75 Through wall 11.43 cm thick 76 Each Excess(+) Full Conversion INR
76 Through wall 22.86 cm thick 77 Each Excess(+) Full Conversion INR
77 Dismantling concrete 78
78 Cement concrete plain1:2:4 mix 79 Cum Excess(+) Full Conversion INR
79 Sub Head 3 -Internal & Estate Sewerage System 80
80 Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonagepipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 81
81 Single Socket Type B 82
82 b) 110mm o/d SWR UPVC pipe lines laid complete 83 Mtr Excess(+) Full Conversion INR
83 b) 160mm o/d SWR UPVC pipe lines laid complete 84 Mtr Excess(+) Full Conversion INR
84 Providing and fixing PVC pipes & specials 4kg/ cm2 including cost of earth work in excavation & back filling as per analysis A 14 complete in all respects. (By Manual) For 160 mm o/d PVC Pipe 85 Mtr Excess(+) Full Conversion INR
85 Providing and fixing in position SS Gratingwith frame of approved make (to the approval of engineer in charge) complete in allrespects 86 Each Excess(+) Full Conversion INR
86 Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. 87
87 For 110mm o/d pipes 88
88 ii) Single Tee With Door 89 Each Excess(+) Full Conversion INR
89 iii) Single Tee 90 Each Excess(+) Full Conversion INR
90 iv) Door Elbow 90 Degree 91 Each Excess(+) Full Conversion INR
91 vi) Vent Cowls 92 Each Excess(+) Full Conversion INR
92 vii) Reducer 110mm x 75mm 93 Each Excess(+) Full Conversion INR
93 ix) P Trap/Floor Trap 110mm x 110mm 94 Each Excess(+) Full Conversion INR
94 xi) Single Y-Junction 95 Each Excess(+) Full Conversion INR
95 (v) Elbow 90 Degree (All side socketed) 96 Each Excess(+) Full Conversion INR
96 For 160 mm o/d pipes 97
97 ii) Single Tee With Door 98 Each Excess(+) Full Conversion INR
98 iii) Single Tee 99 Each Excess(+) Full Conversion INR
99 iv) Door Elbow 90 Degree 100 Each Excess(+) Full Conversion INR
100 v) Elbow 90 Degree 101 Each Excess(+) Full Conversion INR
101 Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement,R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. 102
102 Size 450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty double seal 103 Nos Excess(+) Full Conversion INR
103 Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. 104
104 100mm internal Diametre H.C.I. gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm 105 Nos Excess(+) Full Conversion INR
105 Sub Head 4 - Flooring Wall Tiles & Dismantling 106
106 Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/ Highlighter/ emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x600 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement:4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 107 Sqm Excess(+) Full Conversion INR
107 Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material 108 Sqm Excess(+) Full Conversion INR
108 Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading. 109 Sqm Excess(+) Full Conversion INR
109 Dismantling concrete 110
110 Cement concrete plain1:2:4 mix 111 Cum Excess(+) Full Conversion INR
111 Cement concrete 1:2:4 112
112 a With stone ballast or shingle I mixing by manual means 113 Cum Excess(+) Full Conversion INR
113 C-3 ) ELECTRICAL WORK 114
114 RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: 115
115 Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- 116
116 Wiring light point 117 2 Each Excess(+) Full Conversion INR
117 Wiring 6Amp. Plug control comprising wall socket point 118 1 Each Excess(+) Full Conversion INR
118 Wiring 16/20Amp. power plug control point 119 1 Each Excess(+) Full Conversion INR
119 PVC INSULATED FR COPPER CONDUCTOR CABLES: 120
120 Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- 121
121 Overall size 2.5sq.mm (Un-sheathed) 122 81 mtr. Excess(+) Full Conversion INR
122 PVC, HDPE PIPES & PVC FLEXIBLE PIPES: 123
123 Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- 124
124 Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface) 125 40 mtr. Excess(+) Full Conversion INR
125 Supply and erection of LED batten 20watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.CD). The certification and Specification of the LED fitting should be as approved by O/o Advisor(Technical) , Govt. of Punjab vide Letter no. AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. 126 1 Each Excess(+) Full Conversion INR
126 Supply and Erection of Venti Air Fan 250mm with louver shutter longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the engineer in-charge at site. 127 1 Each Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.19 MB
BOQ_331701.xls
BOQ • 0.40 MB
Technical_Conditions.pdf
Tender Documents • 0.79 MB
SBD.pdf
Tender Documents • 3.95 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .