| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC | ₹1.2 Cr | L1 | Accepted-AOC Rate is lowest |
| 2 | L2₹1.3 Cr+₹8.3 L (6.85%)Rejected-Finance JHARIA BENIGANJ HARDOI | BENIGANJ | HARDOI | UTTAR PRADESH | ₹1.3 Cr+₹8.3 L (6.85%) | L2 | Rejected-Finance Rate is not lowest |
| 3 | L3₹1.4 Cr+₹17.0 L (14.0%)Rejected-Finance | ₹1.4 Cr+₹17.0 L (14.0%) | L3 | Rejected-Finance Rate is not lowest |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
8 Oct 2024, 4:00 pmClosed
SUPERINTENDING ENGINEER
SE, EDC-II, MOHADDIPUR, GORAKHPUR
Execution of work for system augmentation/strengthening (on semi turnkey basis) IN THE AREA OF Electricity Distribution Division-ii, Gorakhpur against Business plan scheme 2024-25
2024_PVVNV_950475_2
09/EDC-II(G)/2024-25
Open Tender
Electrical Works
Lump-sum
90 days
GORAKHPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
SE, EDC-II, MOHADDIPUR, GORAKHPUR
₹1.2 L
23 Oct 2024
2 Oct 2024
9 Oct 2024
2 Oct 2024
8 Oct 2024
2 Oct 2024
Amount
Hkkx&1 ifjorZd {kerko`f) dk dk;ZA 63 ds0oh0,0 ifjorZd ,oa mlls lEcfU/kr lkexzh dh Hk.Mkj [k.M] xksj[kiqj ls dk;Z LFky rd lqjf{kr <qykbZ ¼p<+kbZ ,oa mrjkbZ lfgr½ dk dk;Z ¼nwjh 0 ls 60 fdeh0½A
25 ds0oh0,0 ifjorZd dh Mcy iksy ls fMLesfUVfyax djds dk;Z LFky ls fo|qr Hk.Mkj dsUnz] xksj[kiqj rd lqjf{kr <qykbZ ¼p<+kbZ ,oa mrjkbZ lfgr½ dk dk;Z ¼nwjh 0 ls 60 fdeh0½A
63 ds0oh0,0 ifjorZd dh Mcy iksy ij leLr fQfVax ,Oka vfFkZax ds lkFk ekmfVax djds ÅthZd`r djus dk dk;ZA
100 ds0oh0,0 ifjorZd ,oa mlls lEcfU/kr lkexzh dh Hk.Mkj [k.M] xksj[kiqj ls dk;Z LFky rd lqjf{kr <qykbZ ¼p<+kbZ ,oa mrjkbZ lfgr½ dk dk;Z ¼nwjh 0 ls 60 fdeh0½A
63 ds0oh0,0 ifjorZd dh Mcy iksy ls fMLesfUVfyax djds dk;Z LFky ls fo|qr Hk.Mkj dsUnz] xksj[kiqj rd lqjf{kr <qykbZ ¼p<+kbZ ,oa mrjkbZ lfgr½ dk dk;Z ¼nwjh 0 ls 60 fdeh0½A
100 ds0oh0,0 ifjorZd dh Mcy iksy ij ekmfVax ,Oka vfFkZax djds izR;sd ifjorZd gsrq 4 vnn 240,e0,e0 dh ,Y;qfefu;e yXl lfgr ÅthZd`r djus dk dk;ZA
250 ds0oh0,0 ifjorZd ,oa mlls lEcfU/kr lkexzh dh Hk.Mkj [k.M] xksj[kiqj ls dk;Z LFky rd lqjf{kr <qykbZ ¼p<+kbZ ,oa mrjkbZ lfgr½ dk dk;Z ¼nwjh 0 ls 60 fdeh0½A
100 ds0oh0,0 ifjorZd dh Mcy iksy ls fMLesfUVfyax djds dk;Z LFky ls fo|qr Hk.Mkj dsUnz] xksj[kiqj rd lqjf{kr <qykbZ ¼p<+kbZ ,oa mrjkbZ lfgr½ dk dk;Z ¼nwjh 0 ls 60 fdeh0½A
250 ds0oh0,0 ifjorZd dh fIyaFk fuekZ.k dk dk;Z foHkkxh; fu;ekuqlkj lkexzh lfgrA
250 ds0oh0,0 ifjorZd dh fIyaFk ij ekmfVax djds izR;sd ifjorZd gsrq 4&4 vnn dkWij tsM DySEi ,oa ,Y;qfefu;e yXl lfgr leLr fQfVax ds lkFk ÅthZd`r djus dk dk;ZA
250 ds0oh0,0 ifjorZd dh Mcy dSfedy vfFkZax dk dk;Z leLr lkexzh lfgrA
250 ds0oh0,0 ifjorZd dh ukeZl ds vuqlkj QsfUlax dk dk;Z leLr lkexzh lfgrA
Hkkx&2 f}rh; fcUnq vkiwfrZ ls lEcfU/kr dk;ZA izLrkfor ykbuksa ls lEcfU/kr lkekuksa dh fo|qr Hk.Mkj dsUnz ls dk;Z LFky rd lqjf{kr <qykbZ] yksfMax o vuyksfMax ds lkFk ¼nwjh 0&60 fd0eh0½ %& ¼v½ ih0lh0lh0 iksy
¼c½ ,l0Vh0 iksy
¼l½ vo'ks"k ykbZu lkexzh
fuEu {kerk ds ifjorZdksa dks LVksj lsUVj] xksj[kiqj ls dk;Z LFky rd lqjf{kr <qykbZ dk dk;Z %& ¼v½ 25 ds0oh0,0
¼c½ 63 ds0oh0,0
¼l½ 100 ds0oh0,0
¼n½ 250 ds0oh0,0
lLisU'ku DySEi vkbZ gqd ds lkFk
MsM b.M DySEi
fMLVªhC;w'ku ckSDl gksfYMax DySEi uV cksYV ds lkFk
fofHkUu lkbt ds uV ,.M cksYV
DySEi
LVksu iSM
,Q czsdsV
dzkl vkeZ gksfYMax DySEi
,yVh DySEi
lsdsy bUlqysVj
gksfYMax DySEi VkWi@Mkij
,yqfefu;e yx
leLr fQfVaax ds lkFk flfxay ih0lh0lh0 iksy dk bjsD'ku
leLr fQfVaax ds lkFk Mcy ,l0Vh0 iksy dk bjsD'ku
leLr fQfVax ds lkFk Mcy ih0lh0lh0 iksy dk bjsD'ku
,y0 Vh0 fo|qr midsUnz ls lEcfU/kr leLr fQfVax ds lkFk 11@0-04ds0oh0 ifjorZd dh ekmfVax%& ¼v½ 25 ds0oh0,0 flafxy iksy ij
¼c½ 63 ds0oh0,0 Mcy iksy ij
¼l½ 100 ds0oh0,0 Mcy iksy ij
¼n½ 250 ds0oh0,0 ifjorZd dh fIyaFk ij ekmfVax djds izR;sd ifjorZd gsrq 4&4 vnn dkWij tsM DySEi ,oa ,Y;qfefu;e yXl lfgr leLr fQfVax ds lkFk ÅthZd`r djus dk dk;ZA
250 ds0oh0,0 ifjorZd dh fIyUFk fuekZ.k dk dk;Z ¼fu/kkZfjr ekud ds vuqlkj lkexzh lfgr½
250 ds0oh0,0 ifjorZd dh Qsaflax dk dk;Z ¼fu/kkZfjr ekud ds vuqlkj lkexzh lfgr½
250 ds0oh0,0 ifjorZd dh Mcy dsfedy vfFkZaax dk dk;Z ¼fu/kkZfjr ekud ds vuqlkj lkexzh lfgr½
VªkUlQkjej dh Mcy vfFkZx dk dk;Z
fMLVªhC;w'ku ckDl dh ekmafVx dk dk;Z
LVs] bjsD'ku] xzkmfVax] ukTkfyax] VkbV djus dk dk;Z
iksy dh xzkmfVax lkexzh lfgr
iksy dh vfFkZax dk dk;Z
d.MDVj dk QSykuk] bUlqysVj ij p<+kuk] lSx djds VkbV djuk ,oa izR;sd iksy ij ckbfMax djuk ¼v½ ,p0Vh0 ykbu 3 Qst 3 ok;j
Loading, unloading and safe carriage of following materials from store center, Gorakhpur to work site with proper stocking (Distance about 0 to 60 Km) :- LT AB cable difference size as per Estimate
Laying, stringing, sagging, binding and jumpering of LT AB Cable difference size as per Estimate for LT Line with fixing of Suspension Clamp with I Hook (Insulated), dead end Clamp with I Hook (Insulated), Piercing Connector (Insulated) along with installation LT Three phas Distribution box with clamp and nuts & bolts off siz as per required
Hkkx&3 QhMj ckbQjds'ku ls lEcfU/kr dk;ZA izLrkfor ykbuksa ls lEcfU/kr lkekuksa dh fo|qr Hk.Mkj dsUnz ls dk;Z LFky rd lqjf{kr <qykbZ] yksfMax o vuyksfMax ds lkFk ¼nwjh 0&60 fd0eh0½ %& ¼v½ ih0lh0lh0 iksy
¼c½ ,l0Vh0 iksy
¼l½ vo'ks"k ykbZu lkexzh
¼n½ 11 ds0oh0 vkmVxksbax oh0lh0ch0
fofHkUu lkbt ds uV ,.M cksYV
11 ds0oh0 vkmV xksbax oh0lh0ch0 dks iqjkuh oh0lh0ch0 clckj ds lkFk dkWij clckj LFkkfir djrs gq, ,ykbUes.V djds izkWij fQfVax djrs gq, iqjkuh vfFkZax ls tksM+us dk dk;ZA
Loading, unloading and safe carriage of following materials from store center, Gorakhpur to work site with proper stacking (Distance about 0 to 60 Km) :- XLPE cable 3x185 sqmm size as per Estimate
Laying of XLPE Cable difference size with sand and brick as per Estimate for HT Line as per required
Loading, unloading and safe carriage & Jointing of Cable by cable Jointing kit as per estimate
xkfMZax ,axy DySEi
xkfMZax ,axy
vkbZ gqd foFk uV cksYV
iksyksa dh xzkmfVax dk dk;Z lkexzh lfgr
dzkl vkeZ gksfYMax DySEi
,Q czsdsV foFk uV cksYV
gksfYMax DySEi VkWi@Mkij
leLr fQfVaax ds lkFk flfxay ih0lh0lh0 iksy dk bjsD'ku
leLr fQfVaax ds lkFk flfxay ,l0Vh0 iksy dk bjsD'ku
d.MDVj dk QSykuk] bUlqysVj ij p<+kuk] lSx djds VkbV djuk ,oa izR;sd iksy ij ckbfMax djuk ¼v½ ,p0Vh0 ykbu 3 Qst 3 ok;j
isM+ks dh Vgfu;ksa dks dkVus ,oa NkVus dk dk;ZA
Hkkx&4 11 dsoh ykbuksa ds jksM dzkflax ,oa ?kuh vkcknh {ks=ksa esa xkfMZax ls lEcfU/kr dk;ZA izLrkfor ykbuksa ls lEcfU/kr lkekuksa dh fo|qr Hk.Mkj dsUnz ls dk;Z LFky rd lqjf{kr <qykbZ] yksfMax o vuyksfMax ds lkFk ¼nwjh 0&60 fd0eh0½ %& ¼v½ ih0lh0lh0 iksy
¼c½ vo'ks"k ykbZu lkexzh
fofHkUu lkbt ds uV ,.M cksYV
xkfMZax ,axy
xkfMZax ,axy DySEi
vkbZ gqd foFk uV cksYV
,l0Vh0 iksyksa dh xzkmfVax dk dk;Z lkexzh lfgr
dzkl vkeZ gksfYMax DySEi
,Q czsdsV foFk uV cksYV
LVs] bjsDlu] xzkmfVax] ukTkfyax] VkbV djus dk dk;Z
ih0lh0lh0 iksy dh vfFkZax dk dk;Z
,p0Vh0 ykbu es yxs d.MDVj dh th0vkbZ0 ok;j ls xkfMZax djus dk dk;ZA
Hkkx&5 vkj0,e0;w0 ;wfuV LFkkfir djus dk dk;ZA (A) Cartage of following materials from Store Center, Gorakhpur to work site with loading-unloading & proper stocking (distance about 0-60 Kms) (a) Cable Al. 3x185 sq.mm. XLPE 11 KV
(b) 11KV Outdoor Cable Box for 3X185mm sq Cable
(B) Decentralised materials provided by Contractor at site. SF 6 SCADA compatible RMU 3 W ABB Make/Scinder Make/ C.G. Make or any reputed manufacturer With number plate fitting and danger board.
GI Strip (40X6 mm)
16 Gauage GI Net between front & back (H-500 W-600 with Hole Dia 10mm and thickness of 1.5mm) in 25X25X3 mm angle frame with fasteners of required size for protection from Garbage
(C) Erection & Labour Charges. Construction of new plinth (2700 X 2000 X 1200mm) as per specifications
Fixing of RMU on plinth with complete fittings with Cable box.
Chemical earthing of RMU with materials.
Fixing of GI Strip with Electrode at One end & RMU on other end
Internal wiring of RMU with CT & Auxiliary
Erection of fencing with materials
Jointing of 11 KV Indoor cable Box with 3x185mm Sq. Cable
Fixing of Net with Fasteners in Angle Frame
Laying of 11 KV XLPE 3x185 sqmm.
Hkkx&6 {kfrxzLr oh0lh0ch0@cl diyj cnyus dk dk;ZA 11 ds0oh0 cl diyj dh Hk.Mkj [k.M xksj[kiqj ls fo|qr forj.k [k.M&f}rh;] xksj[kiqj ds {ks=kUrxZr fofHkUu midsUnzksa ij <qykbZ dk dk;Z ¼p<+kbZ] mrjkbZ ,oa lqjf{kr j[kus lfgr½ nwjh 0 ls 60 fdeh0A
midsUnz ij LFkkfir 11 ds0oh0 cl diyj dh fMLesaVfyax dk dk;ZA
fo|qr forj.k [k.M&f}rh;] xksj[kiqj ds {ks=kUrxZr fofHkUu midsUnzksa ij 11 ds0oh0 cl diyj dks iqjkus ds lkFk dkWij clckj LFkkfir djrs gq, ,ykbUes.V djds izkWij fQfVax djrs gq, iqjkuh vfFkZax ls tksM+us dk dk;ZA
11 ds0oh0 vkmV budfeax@xksbax oh0lh0ch0 dh Hk.Mkj [k.M xksj[kiqj ls fo|qr forj.k [k.M&f}rh;] xksj[kiqj ds {ks=kUrxZr fofHkUu midsUnzksa ij <qykbZ dk dk;Z ¼p<+kbZ] mrjkbZ ,oa lqjf{kr j[kus lfgr½ nwjh 0 ls 80 fdeh0A
fofHkUu midsUnzksa ij LFkkfir 11 ds0oh0 budfeax@vkmV xksbax oh0lh0ch0 dh fMLesUVfyax djds midsUnz ifjlj esa lqjf{kr j[kus dk dk;ZA
fo|qr forj.k [k.M&f}rh;] xksj[kiqj ds {ks=kUrxZr fofHkUu midsUnzksa ij 11 ds0oh0 budfeax@vkmV xksbax oh0lh0ch0 dks iqjkuh oh0lh0ch0 clckj ds lkFk dkWij clckj LFkkfir djrs gq, ,ykbUes.V djds izkWij fQfVax djrs gq, iqjkuh vfFkZax ls tksM+us dk dk;ZA
fo|qr forj.k [k.M&f}rh;] xksj[kiqj ds {ks=kUrxZr fofHkUu midsUnzksa ij LFkkfir 11 ds0oh0 fMLesUVy budfeax@vkmV xksbax oh0lh0ch0 dks fo|qr midsUnz ls Hk.Mkj dsUnz xksj[kiqj rd lqjf{kr <qykbZ dk dk;Z ¼p<+kbZ] mrjkbZ ,oa lqjf{kr j[kus lfgr½ nwjh 0 ls 80 fdeh0A
Hkkx&7 fo|qr midsUnzks xaxVgh] [ktuh] muoy o gjiqj vuUriqj esa cSVjh ,oa cSVjh pktZj cnyus dk dk;Z ¼lkexzh lfgr½ ¼v½ cSVjh 24 cksYV
¼c½ pktZj 24 cksYV
Hkkx&8 11 ds0oh0 ttZj [email protected]@dsfcy cnyus dk dk;ZA izLrkfor ykbuksa ls lEcfU/kr lkekuksa dh fo|qr Hk.Mkj dsUnz ls dk;Z LFky rd lqjf{kr <qykbZ] yksfMax o vuyksfMax ds lkFk ¼nwjh 0&60 fd0eh0½ %& ¼v½ ih0lh0lh0 iksy
¼l½ vo'ks"k ykbZu lkexzh
fofHkUu lkbt ds uV ,.M cksYV
Loading, unloading and safe carriage of following materials from store center, Gorakhpur to work site with proper stacking (Distance about 0 to 60 Km) :- LT AB cable difference size as per Estimate
Laying, stringing, sagging, binding and jumpering of LT AB Cable difference size as per Estimate for LT Line with fixing of Suspension Clamp with I Hook (Insulated), dead end Clamp with I Hook (Insulated), Piercing Connector (Insulated) along with installation LT Three phas Distribution box with clamp and nuts & bolts off siz as per required
iksyksa dh xzkmfVax dk dk;Z lkexzh lfgr
dzkl vkeZ gksfYMax DySEi
iksyksa dh vfFkZax dk dk;Z
LVs] bjsDlu] xzkmfVax] ukTkfyax] VkbV djus dk dk;Z
leLr fQfVaax ds lkFk flfxay ih0lh0lh0 iksy dk bjsD'ku
d.MDVj dk QSykuk] bUlqysVj ij p<+kuk] lSx djds VkbV djuk ,oa izR;sd iksy ij ckbfMax djuk ¼v½ ,p0Vh0 ykbu 3 Qst 3 ok;j
Hkkx&9 XLPE dsfcy yxkus dk dk;ZA Loading, unloading and safe carriage of following materials from store center, Gorakhpur to work site with proper stacking (Distance about 0 to 60 Km) :- XLPE cable difference size as per Estimate
Laying of XLPE Cable difference size with sand and brick as per Estimate for 11 kv Line as per required
Loading, unloading and safe carriage of cable jointing kit and Jointing of cable by jointing kit with 11 kv Line as per required
M/s Anil kumar singh
Manish Traders
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .