| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.1 LAccepted-AOC TAILOR MARKET MAIN BAZAAR MANDI ADAMPUR 125052 | HISAR | HARYANA | 125052 | ₹40.1 L | L1 | Accepted-AOC L1 |
| 2 | L2₹42.8 LRejected-Finance 2ND FLOOR PLOT NO 338 UDHYOG VIHAR PHASE IV GURUGRAM 122015 HARYANA | GURUGRAM | HARYANA | 122015 | ₹42.8 L | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical SCO 529 3RD FLOOR KESHO RAM COMPLEX SECTOR 4 C CHANDIGARH 160047 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160047 | - | - | Rejected-Technical Not Eligible |
| 4 | Rejected-Technical SHOP NO 2 TANIYA MARKET GALI NO 3 RAJGARH ROAD AZAD NAGAR HISAR 125001 | HISAR | HISAR | HARYANA | 125001 | - | - | Rejected-Technical Not Eligible |
| Sl No | Description | Qty | Unit | Prime Computers L1 | Netromics Engineering Solutions Private Limited L2 |
|---|---|---|---|---|---|
| 1.00 | [23.1.6.2]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 6.2. Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) [Through Rate] | 300 | Per Metre | 147 ₹44,100 | 162 ₹48,600 |
| 2.00 | [23.22.1.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA [Through Rate] | 1 | Each | 10,115 ₹10,115 | 11,200 ₹11,200 |
| 3.00 | [23.22.1.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.12. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 300 to 400 amp , 50 KA [Through Rate] | 1 | Each | 20,066 ₹20,066 | 21,230 ₹21,230 |
| 4.00 | [23.22.1.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.3. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA [Through Rate] | 10 | Each | 4,211 ₹42,110 | 4,480 ₹44,800 |
| 5.00 | [23.22.1.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.4. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 125 to 160 Amp, 25 KA [Through Rate] | 2 | Each | 4,920 ₹9,840 | 5,820 ₹11,640 |
| 6.00 | [23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA [Through Rate] | 7 | Each | 6,050 ₹42,350 | 6,122 ₹42,854 |
| 7.00 | [23.22.2.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP [Through Rate] | 2 | Each | 1,780 ₹3,560 | 2,050 ₹4,100 |
| 8.00 | [23.22.4.10]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.10. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 6 way ( 8 incoming 3phase*6 outgoing) [Through Rate] | 5 | Each | 6,855 ₹34,275 | 7,420 ₹37,100 |
| 9.00 | [23.22.4.6]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.6. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 6 way ( 8 incoming 3phase*6 outgoing) [Through Rate] | 1 | Each | 3,171 ₹3,171 | 3,820 ₹3,820 |
| 10.00 | [23.22.4.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.7. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing) [Through Rate] | 8 | Each | 3,941 ₹31,528 | 4,050 ₹32,400 |
Tender Value
₹40.9 L
EMD Value
₹81,775
Closing Date
10 Feb 2026, 11:00 amClosed
PRAMESH Kumar
ED - Hisar
Construction of Govt. ITI Jakhandadi at Ratia in Fatehabad Distt.(pdg. Balance EI work and ELV Services only)
2026_HRY_500219_1
2026D2E3698A 9C36 4EB8 A959 1096C4C0A94A666BAR
Open Tender
Electrical Works
90 days
JAKHANDADI (DHANI)
2 documents required · 2 mandatory
₹5,000
₹81,775
Yes
18 May 2026
3 Feb 2026
10 Feb 2026
3 Feb 2026
10 Feb 2026
3 Feb 2026
[23.1.6.2]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 6.2. Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) [Through Rate]
[23.22.1.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA [Through Rate]
[23.22.1.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.12. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 300 to 400 amp , 50 KA [Through Rate]
[23.22.1.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.3. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA [Through Rate]
[23.22.1.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.4. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 125 to 160 Amp, 25 KA [Through Rate]
[23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA [Through Rate]
[23.22.2.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP [Through Rate]
[23.22.4.10]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.10. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 6 way ( 8 incoming 3phase*6 outgoing) [Through Rate]
[23.22.4.6]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.6. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 6 way ( 8 incoming 3phase*6 outgoing) [Through Rate]
[23.22.4.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.7. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing) [Through Rate]
[23.22.4.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.9. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 4 way ( 8 incoming and 3phase*4 outgoing) [Through Rate]
[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate]
[23.22.5.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE [Through Rate]
[23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE [Through Rate]
[23.23.2.2]MISCELLANEOUS 2.2. Supply of GI pipe (B-Class) for suspension rod of ceiling fan including threading if required. 20 mm dia [Through Rate]
[23.23.8.1]MISCELLANEOUS 8.1. Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. 2 pair telephone wire [Through Rate]
[23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate]
[23.24.1]MS STAND, BUS BAR CHAMBER AND PANELS 1. Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide. [Through Rate]
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate]
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate]
[24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. [Through Rate]
[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate]
[24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. [Through Rate]
[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate]
[24.13.32]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 32. 25 Sq mm 4 core (Arm.) [Through Rate]
[24.13.38]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 38. 35 Sq mm 3.5 core (Arm.) [Through Rate]
S/E/T/C of Telephone Jack of MK make.(Exclusive GST)
SITC of 5 KVA Online UPS with 2 Hour power Backup with( 16 No. Battery 42Ah,12Volt with necessary MS stand for batteries and UPS) all necessary accessories civil electrical works and peripheral items.(Makes:- Eaton/Numeric/ELNOVA ) (Excluding GST)
SITC of minimum 1000 Mtr. Range Siren generator provided at the roof of the building with separate power suppl, relay etc.. Make: National/Kheraj (Rates are excluding GST).
SITC of IDF/MDF with Krone Make module on Krone Make MS Box duly painted and having lock facilities. 20 Pair IDF (Exclusive GST)
S/E/T/C of Face plate (Single / Dual) Make and Model: RandM/Dlink/Molex (GST Exclusive)
SITC of Analog Addressable type Active Repeater Fire Alarm Panel with Backlit LCD display, having controlls for reset, mute, accept, silence alarms and self test conforming to BS5839 standards with all labour and materials required to complete the job in all respect up to the entire satisfaction for engineer-in-charge of work. Make Siemens/Honeywell/G.S.T (GST Exclusive)
SITC ofintelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliant to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect Make Siemens/Honeywell/G.S.T(GST Exclusive)
SITC of Addressable Control Relay Module with flexible network structures with a maximum switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification Make Siemens/Honeywell/G.S.T (GST Exclusive)
SITC of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/voltage monitoring shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be consider separately for payment).Make Siemens/Honeywell/G.S.T (GST Exclusive)
SITC of ABC Stored Preassure type Fire Extinguisher 6kg. Capacity (5 year warranty) bearing ISI Mark for fire fighting ABC class of fire extinguisher will be manufactured strictly as per BIS IS:683:2006 bearing ISI Mark EN3 615 approved powder (MAKE CEASEFIRE / SAFEX/ SAVEMAX)(GST Exclusive)
SITC of Co2 type Fire Extinguisher 4.5 Kgs capacity made from brand new seamless cylinder, as per ISI 7285 and CCE approval, fitted with a Discharge hose and horn and squeeze Grip type valve with initial charge as per ISI 15683:2006 specification, bearing ISI Mark.(Make - Cease fire/ Savemax/ SAFEX). (GST Exclusive)
Wiring for Fire Alarm system with the following sizes of FRLS insulated copper conductor single core 1100 volts grade cables in existing surface/recessed M.S. conduit etc. as complete as required. Make Finolex/Grandly/Polycab 2 x 1.5 sq.mm (GST Exclusive)
S/E/T/C of UTP cat 6 Mounting 3 Feet length Patch Cords Low smoke zero halogen (LSZH/LS0H )complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Make : Dlink / Molex / RandM ( Rates are of GST excluded.)
S/E/T/C of 17U rack for switch Mounting with Fan and povwer Strip, PDU, Hatoware Mounting Kt Make: Make COMRACK/Hivenetwork/Dyanmic ( Rates are of GST excluded.)
S/E/T/C of POE 24 Port 10/100/1000 Base T, 2X 1G SFP plus Ports, 1 X10/100Base-T out of band management post 1 X Serial Console port RJ45, Switch should Support stacking up to 4 switches Switch should have switching fabric performance of minimum 88GBPS sWitch fabric switch should have forwarding rate of 65 Mpps Switch should have 16K MAC entries, should support inter / external redundant PSU, Switch should have operating temperature (O C to 50 C) ). (Make Alcatel Lucent / Cisco / Nexxus/ Junipher .(GST Exclusive)
Supply Installation Testing and Commissioning of Cat 6 Information outlet to complete the job in all respect. Make : Dlink / Molex / RandM (exclusive GST)
Supply Installation Testing and Commissioning of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having nos. of loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 2 Serial Ports. The pane\l shall have a built in power Supply, battery charger maintenance free battery capable of running for a minimum 24 hours operation complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS.Make: Honeywell/G.S.T/Siemens. (Exclusive GST)
Supply Installation Testing and Commissioning of Addressable Loop Powered Sounder with Strobe / flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work.Make:Honeywell/G.S.T/Siemens. (Exclusive GST)
Supply Installation Testing and Commissioning of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink sulphate as bare chemical class 1 material PSPA fixed on 3mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work.Make: PES/Glolite/OMEX. (Exclusive GST)
Supply,Erection testing and Commissioning of UTP Face plate(Single/dual) complte in all respect upto the entire satisfaction of Engineer-in-Charge of the work Make:- RandM/Molex/D-link (Exclusive GST)
Supply,Erection testing and Commissioning of intelligent Analog Addressable type Isolator having Surface or flush mounting option fully compliant to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect Make:Honeywell / GST/ Siemens. (Exclusive GST)
S/E/T/C of UTP cat 6 Mounting 7 Feet length Patch Cords Low smoke zero halogen (LSZH/LS0H )complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Make : Dlink / Molex / RandM ( Rates are of GST excluded.)
S/E/T/C of Wall mounted 9U enclosure of dimension 600W X9UX500D with front sheet steel glass door, top and bottom cCover with cable entryprovision, integrated side walls,1 pair of 19` angles with wall mounting provision, captivehardware(pack of 20) complete in all respect upto entire satisfaction Engineer in charge ofworks. Make COMRACK/Hive Network/Dyanmic.. ( Rates are of GST excluded.)
SITC of 24-port 19` 1 U jack panel which Should Be made of sheet steel 1.5 mm, Should be 19` 1U straight Patch Panel, 24-port,Should have integral cable management Metal shelf, Should accept Shielded as well as Unshielded jacks, Should have rear cable management shelf metallic powder coated. Make: Molex/Dlink/RandM. (Exclusive GST)
SITC of Push Button Telephone Desktop model with flash, Hold, Pause keys etc and Voice Mail Message indication LED Telephone instrument make Beetle C -51 . (Exclusive GST)
SITC of LED TV 55` Full HD 4K smart version having resolution 4K(3840*2160) HDR 10 plus and HLG,HDMI port,Components video input,1 digital out,complete accessories as supplied by th manufacturer.Make- Samsung,Panasonic,LG (Exclusive GST)
SITC of Network Video Recorder 32 Channel Network recorder With HD to a maximum of 32 IP cameras,The recorders can be installed with a maximum of internal HDDs for video storage. Option of a HDDs for storage, for video export. Max. capacity per HDD: 10 TB. 1 no. E-SATA supported. The recorders come with a built-in PoE plus switch as an option. 6 alarm i/p and 2 relay o/p. Simultaneous 1/4/9/16 channels playback. H.265/H.264/MJPEG supported. iPhone/Android support. Maximum incoming bandwidth of 320 Mbps. Maximum recording bandwidth of 320 Mbps. 1 I/O for audio. 1 VGA and 2 HDMI outputs. CE, UL and FCC certified MAKE: Axis/Pelco/Honey well. (Exclusive GST)
a S/E/T/C of 24 Port Access Switch with 24x 1G Base-Tand 4x1G SFP Slots Console port 1 Console port 1 Primary power internal 1 fan 1 GHz MIPS dual-core File system flash 512 MB Packet Buffers 16 Mb/s Max switching ASIC capacity 128 Gb/s Switch capacity with all ports (full duplex) 56 Gb/s Switch frame rate @ 64 byte packet 41.7 Mpps System power consumption: • Idle • 100% traffic all ports (max) 13,1 W 29.5 W MTBF (hours) @ 25C 1,632 k Operating temperature Operating temperature 0°C to 45°C (32°F to 113°F Storage temperature -20°C to 60°C (-4°F to 140°F) Fixed 1RU chassis 24 RJ 45 10/100/1G BaseT, 4 SFP (1G) uplink ports. Fan-less complete in all respects up to the entire satisfaction of the Engineer-in-charge of work. Make: Nexus / Cisco / Zyxel. ( Rates are of GST excluded.
S/E/T/C of IP IR PTZ Dome Camera PoE Enabled (High Definition) image device/Sensor - 1/3` Progressive Scan CCD/ Progressive scan CMOS or better, Resolution - 2 Megapixel, 1080p (1920x1080) or better, Optical Zoom 25X and Digital Zoom: 12X, lR Light and Distance - lR range up to 150 Mtrs. Or better, Signal to Noise Ratio - )_50 dB (AGC OFF ), PAN and Tilt travel - Pan 360 endless Tilt 0 to -90 (Auto Flip), Minimum lIIumination - 0.3Lx Color and B/W 0.01Lx, Day Night - Auto Day/Night with Auto lR-CUT fitter with auto switch, Encoding, Video Compression - H.265 MJPEG Triple Stream encoding, Frame Rate - Main Frame 30 FPS in all resolution or better, Audio Compression - G.711/G.726, Storage - SD Card shoutd be expandabte up to 128 GB, Protocols - lPv4/lPv6, TCP/lP, UDP, RTP, RTSP, HTTP, HTTPS, ICMP, SMTP, NTP, DHCP, UPnP, IGMP, SNMP, IEEE 802.1 X, System Compatibitity - ONVlF Profite S and G, Privacy Zone - Minimum 4 Privacy zones or higher, Additional Features, Noise Reduction-Digitat Noise Reduction on/off ., WDR -90dB True WDR or better, Alarm Input,/ Alarm Output-1 Alarm Input, 1 Alarm Output, Environment-, Operating Environment-Outdoor, Operating Temoerature- 0`C to 50`C, lngress protection lP66 or better., Certificates: UL, FCC, EN, Approved Make: Axis/Pelco/Honey well..(Rates are excluding GST)..
Supply,Erection testing and Commissioning of 1 KVA UPS with 30 min backup online with Suitables batteries with necessary MS stand for batteries. Make Microtek / Luminous / Elnova. (Exclusive GST)
Supply and laying of 1.5 m HDMI cable. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. Make:Kramer / Extron / Linetek.(Rates are excluding GST)..
Supply Installation Testing and Commissioning of Intelligent Addressable Photo-Thermal/Multi Detector with 3600 LED view, Electronically addressable complete with Mounting Base. The detector shall share the analog datapoints to the panel. The detector should have strong environmental adaptability by drift compensation with 2 programmable sensitivity levels. The detector shall operate in -10°C ~ 50°C Temperature and will give alarm in case of smoke detection or ROR (Rate of rise plus 10 ºC in 1 min) or at a Fixed heat temperature at (58 ºC). Operating Voltage shall be 16 to 28 Vdc. The Detector shall meet RoHS standard and shall confirm to IS2189 Standards and Duly Approved by LPCB/UL/FM with relevant IS/EN/NFPA Standard. (Detectors without inbuilt isolators may be considered with an additional isolator module after 20 devices) Make: Honeywell/G.S.T/ Siemens Cereberus.(Rates are excluding GST)..
S/E/T/C of 5MP IP Network TDN Low-Light IR Rugged Bullet Camera, 1/2.8` CMOS or better, 5MP (2592 x 1944) @ 25fps or better, triple stream at various resolution and Frame Rates, Min. Illumination required 0.005 lux @ F1.6 (color), 0 Lux IR On, 4 IR LEDs Smart IR with upto 50m IR distance, Auto ICR (Infrared Cut Filter) 120dB True WDR, S/N Ratio 50db, Shutter Speed 1/8 - 1/30,000: Adavance Video Compression technology such as H.265 and H.264 High Profile and MJPEG , Triple stream, 2.7 to 13.5mm 5X motorized focus and zoom lens, BLC, HLC, 3DNR White Balance, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, and People Counting, 4 Privacy Mask, 8 Region Of Intreset, Defog, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, Dual channel Audio, 256GB SD card support, Alarm: In/ 1out, PoE (802.3 af) and 12V DC, Max 6W, IP 66, IK 10 vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S/G/T/M Compliant (Can be verified from Onvif Website and T profile must have secure streaming), UL, CE, FCC, EN, RoHS and NDAA Section 889 compliant. Make: Axis/Pelco/Honey well..(Rates are excluding GST)..
S/E/T/C of 5MP IP Network TDN Low-Light IR Rugged Dome Camera, 1/2.8` CMOS or better, 5MP (2592 x 1944) @ 25fps or better, triple stream at various resolution and Frame Rates, Min. Illumination required 0.005 lux @ F1.6 (color), 0 Lux IR On, 4 IR LEDs Smart IR with up to 50m IR distance, Auto ICR (Infrared Cut Filter) 120dB True WDR, S/N Ratio 50db, Shutter Speed 1/8 - 1/30,000: Advance Video Compression technology such as H.265 and H.264 High Profile and MJPEG , Triple stream, 2.7 to 13.5mm 5X motorized focus and zoom lens, BLC, HLC, 3DNR White Balance, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, and People Counting, 4 Privacy Mask, 8 Region Of Interest, Defog, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, Dual channel Audio, 256GB SD card support, Alarm: In/ 1out, PoE (802.3 aft) and 12V DC, Max 6W, IP 66, IK 10 vandal proof with Die Cast Aluminum Housing, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S/G/T/M Compliant (Can be verified from Onvia Website and T profile must have secure streaming), UL, CE, FCC, EN, RoHS and NDAA Section 889 compliant. Make: Axis/Pelco/Honey well.(Rates are excluding GST).
S/E/T/C of Non-Blocking 32 Bit microprocessor / micro controller based on Stored Program Control Technique. Microprocessor EPABX system expandable up to 48 ports and system components as per specifications / features: - Make :- MATRIX /ALACTAL /UNIFY. EPABX system should be configured for: 04 Trunk Lines,24 Analog Extensions 4 Digital EXP UPTO 48, 5 IP user Hybrid- Preference would be given to the manufacturer having DSIR recognized RandD. - System should have a system memory of minimum 300 names and number., - System should have Dial by Name facility through built in keyboard in digital key phone instruments. (Rates are excluding GST).
Supply Installation Testing and Commissioning of Intelligent Addressable Heat/Thermal Detector with 3600 LED view, electronically addressable complete with Mounting Base. The detector shall share the analog datapoints to the panel. The detector should have strong environmental adaptability by drift compensation with 2 programmable sensitivity levels. The detector shall operate in -10°C ~ 50°C Temperature and will give alarm in case of ROR (Rate of rise plus 10 ºC in 1 min) or at a Fixed heat temperature at (58 ºC). Operating Voltage shall be 16 to 28 Vdc. The Detector shall meet RoHS standard and shall confirm to IS2189 Standards and Duly Approved by LPCB/UL/FM with relevant IS/EN/NFPA Standard. (Detectors without inbuilt isolators may be considered with an additional isolator module after 20 devices). Make: Honeywell/G.S.T/ Siemens Cerberus.(Rates are excluding GST).
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.14 MB
BOQ_578825.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid