| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹20.0 L+₹4,549 (0.23%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹21.9 L+₹1.9 L (9.74%)Rejected-Finance FLAT NO 601 TOWER NO 30 SECTOR NO 21 AMANORA PARK TOWN HADAPSAR PUNE 411028 | PUNE | MAHARASHTRA | 411028 | L3 | Rejected-Finance High Rate | |
| 4 | L4₹24.4 L+₹4.5 L (22.6%)Rejected-Finance 3 2 G NO 1 ROSHAN VIHAR EAST SADATPUR NORTH EAST DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L4 | Rejected-Finance High Rate | |
| 5 | L5₹24.6 L+₹4.6 L (23.3%)Rejected-Finance | L5 | Rejected-Finance High Rate |
Tender Value
₹34.9 L
EMD Value
₹69,800
Closing Date
10 Oct 2023, 6:00 pmClosed
GE (Central) Pune
Garrison Engineer (Central) Pune, Arjun Marg, Pune-411001
8416 REPAIR/ REPLACEMENT OF INTERNAL ELECTRIC WIRING FITTINGS FIXTURES AND CONNECTED ELECTRICAL ITEMS AT MARRIED ACCN FOR OFFRS JCOS ORS AND SERVANT QTRS AND DAY TO DAY TO MAINT WELCOME MAINT FOR INTERNAL E/M SERVICES FOR CERTAIN ACCN IN AFMC
2023_MES_617161_1
8416 REPAIR/ REPLACEMENT OF INTERNAL ELECTRIC WIRI
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (Central) Pune
As per Tender NIT
9 documents required · 9 mandatory
₹500
GE (Central) Pune
₹69,800
Yes
21 Dec 2023
4 Sept 2023
12 Oct 2023
4 Sept 2023
10 Oct 2023
18 Sept 2023
Amount
S & F in repairs Modular Switch flush type, single pole, one way, 6/10 Amp complete.
S & F in repairs Modular Switch flush type, single pole, one way, 15 Amps / 16 Amp complete.
S & F in repairs Modular Switch flush type, single pole, two way, 6 Amps /10 Amps complete.
S & F in repairs Bell push modular 6 Amps complete all as specified.
S & F in repairs Modular Socket outlet multipurpose 6 Amps , 2/3 pin combined flush type complete.
S & F in repairs Modular Socket outlet multipurpose Socket 6 Amps / 16 Amps , 2/3 pin combined flush type complete.
S & F in repairs modular step type fan regulator single module 230 Volt , 50 HZ , AC supply complete.
S & F in repairs modular fan regulator , stepped type (5 steps) , two module 230 Volt , 50 HZ , AC supply complete.
S & F in repairs Switch piano flush type, single pole, one way, 5 Amps complete.
S & F in repairs Switch piano flush type, single pole, two way, 5 Amps complete.
S & F in repairs Bell push 6 Amps 230 Volt , 50 HZ , AC supply complete.
S & F in repairs Switch piano flush type, single pole, one way ,15 Amps complete.
S & F in repairs Socket outlet multipurpose 2 in 1, 3 pin, 5 Amps flush type complete .
S & F in repairs Socket outlet multipurpose 2 in 1, 3 pin, 5 Amps and 15 Amps , flush type complete.
S & F in repairs Switch socket combination multipurpose with Box and shutter type, 3 pin, 5 Amps and 15 Amps , flush type universal complete.
S & F in repairs Switch socket combination multipurpose with Box and shutter type, 5 Amps , flush type universal complete.
S & F in repairs ceiling fan regulator socketed, stepped type (5 steps) , flush type, 230 Volts AC supply complete .
S & F in repairs Ceiling rose, surface Bakelite , 2 to 3 terminals , ISI marked , for batten fitting complete.
S & F in repairs Lamp holder, PVC / Polycarbonate type with back plate complete.
S & F in repairs Bell Electric , Ding dong/ musical type, 230 Volt , 50 Hz , AC supply complete.
S & F in repairs capacitor 2.5 / 3.15 / 4.0 MFD 230 Volt, AC supply complete
S & F in repairs Plug top 3 Pin , 15 Amps , 230 Volt , AC supply complete
S & F in repairs PVC surface modular box of size up to 6 module with modular plates inner and outer with each terminal including necessary fixing arrangements complete.
S & F in repairs PVC surface modular box of size 8 to 12 module with modular plates inner and outer with each terminal including necessary fixing arrandements complete.
S & F in replacement LED Tube light fittings wall / Ceiling mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient 20 Watt LED 6500 K with high efficient integral constant current LED Driver 230 Volts etc, complete with mounting batten including all accessories internally prewired and including provision of new multistranded copper conductor of suitable size from ceiling rose to fitting complete all as specified and as directed.
S & F in replacement LED Tube light fittings wall / Ceiling mounted, innovative LED batten that works automatically through motion detection within 5 metre range & turn off within 30 seconds of non movement LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient 20 Watt LED 6500 K with high efficient integral constant current LED Driver 230 Volts etc, complete with mounting batten including all accessories internally prewired and including provision of new multistranded copper conductor of suitable size from ceiling rose to fitting and making good disturbed sufaces on wall/floor/roof complete all as specified and as directed.
S & F in replacement LED Tube light fittings wall / Ceiling mounted, inverter LED batten with square profile and polycarbonate channel Lithium ion battery with charging time 8 hours - 10 hours and back up time upto 4 hours, environmental friendly, energy efficient 20 Watt LED 6500 K with high efficient integral constant current LED Driver 230 Volt etc, complete with mounting batten including all accessories internally prewired and including provision of new multistranded copper conductor of suitable size from ceiling rose to fitting and making good disturbed sufaces on wall/floor/roof complete all as specified and as directed.
S & F in replacement wall / ceiling mounted decorative ultra slim square profile LED lighting 10 Watt LED 6500 K fixture with extruded polycarbonate, environmental friendly, energy efficient and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements including provision of new multistranded copper conductor ceiling rose to fitting and making good disturbed sufaces on wall/floor/roof complete all as specified and as directed.
S & F in replacement sleek round recessed mounting LED downlight fitting WH/WW , 5/6 Watts with inbuilt driver in polycarbonate body to deliver low glare illumination with optimized heat sink for efficient heat dissipation , 230 Volts with connector block etc complete with all accessories internally pre wired and necessary fixing arrangements complete all as specified and as directed.
S & F in replacement slim Panel round recessed mounting LED downlight fitting WH / WW/NW , 3 in 1 , 12 Watts with inbuilt driver in polycarbonate body to deliver low glare illumination with optimized heat sink for efficient heat dissipation, 230 Volts with connector block etc complete with all accessories internally pre wired and necessary fixing arrangements complete all as specified and as directed.
S & F in replacement sleek round recessed mounting LED downlight fitting WH/WW , 18/20 Watts with inbuilt driver in polycarbonate body to deliver low glare illumination with optimized heat sink for efficient heat dissipation, 230 Volts with connector block etc complete with all accessories internally prewired and necessary fixing arrangements complete all as specified and as directed.
S & F in replacement Home decor , decorative wall lights gold finish fixture with white glass diffuser suitable for 7/9 Watt LED filament lamp E-27/B-22 base holder, including LED filament lamp 7/9 Watt, 230 Volts complete with all accessories internally prewired and necessary fixing arrangements and making good disturbed sufaces on wall/floor/roof complete all as specified and as directed.
S & F in replacement home decor decorative light filament lamp 4 Watt, 2700 K suitable for E-27/B-22 base holder and necessary fixing arrangements complete all as specified and as directed.
S & F in replacement LED security light of luminaires 20 Watt complete with all accessories and including wall mounting bracket of suitable size including clamps, nut bolts etc including all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size from ceiling rose to light fitting including necessary 40mm bore dia GI pipe light grade bracket 0.6 to 0.9 metre long bend to required shape with clamps, nut, bolts complete all as specified and as directed.
S & F in replacement energy saving new generation environmental friendly long life versatile 30 Watt energy efficient LED security light in pressure die cast housing, top maintainable, with clear PC, higher efficiency secondary moulded lens with inbuilt lithium battery pack for power back upto 2 hours, IP-66. Luminaire should be complete with Isolated electronic constant current driver efficiency, RTC enabled for automatic switch ON/OFF of light fitting suitable for operating in voltage range 140 Volt to 270 Volts, inbuilt internal surge protection device and necessary mounting arrangements and provision of 1.5 Sqmm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary 40mm bore dia GI pipe light grade bracket 0.6 to 0.9 metre long bend to required shape with clamps, nut, bolts complete all as specified and as directed.
Taking down unserviceable ceiling fan / Exhaust fan of any sweep, keeping with safe custody , replacement of unserviceable 3 core PVC insulated, PVC sheated 3 core multistranded copper conductor cable of size 23/0.193 from ceiling rose to fan terminal , overhauling the ceiling fan / exhaust fans, replacement of the split pin / rubber bush / fan hook / clamps / nuts / bolts / washers / condensor/ armature of suitable size, painting of ceiling fan / exhaust fans complete with synthetic enamel paint by spray painting including filling cavities with filler one coat after cleaning all dust etc and and refixing the same to its original position in servicable conditions complete all as specified.
M & L for Sub main wiring complete with two single core 1.5 Sqmm, 1100 Volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of one run of single core 1.5 Sqmm drawn through in and including non-metallic PVC rigid conduit of suitable size including all accessories including taking down old unserviceable / worn out sub main wiring of any type complete including making good of disturbed surfaces all as specified and as directed. Note :- 2 runs of 1.5 Sqmm conductor, one run of 1.5 Sqmm earth conductor and one run of PVC conduit shall be measured as one unit length.
M & L for Sub main wiring complete with two single core 2.5 Sqmm, 1100 Volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of one run of single core 2.5 Sqmm drawn through in and including non-metallic PVC rigid conduit of suitable size including all accessories including taking down old unserviceable / worn out sub main wiring of any type complete including making good of disturbed surfaces all as specified and as directed. Note :- 2 runs of 2.5 Sqmm conductor, one run of 2.5 Sqmm earth conductor and one run of PVC conduit shall be measured as one unit length.
M & L for Sub main wiring complete with two single core 4 Sqmm, 1100 Volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of one run of single core 4 Sqmm drawn through in and including non-metallic PVC rigid conduit of suitable size including all accessories including taking down old unserviceable / worn out sub main wiring of any type complete including making good of disturbed surfaces all as specified and as directed. Note :- 2 runs of 4 Sqmm conductor, one run of 4 Sqmm earth conductor and one run of PVC conduit shall be measured as one unit length.
M & L for Sub main wiring complete with two single core 6 Sqmm, 1100 Volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of one run of single core 6 Sqmm drawn through in and including non-metallic PVC rigid conduit of suitable size including all accessories including taking down old unserviceable / worn out sub main wiring of any type complete including making good of disturbed surfaces all as specified and as directed. Note :- 2 runs of 6 Sqmm conductor, one run of 6 Sqmm earth conductor and one run of PVC conduit shall be measured as one unit length.
M & L for Sub main wiring complete with four single core 4 Sqmm, 1100 Volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of one run of single core 4 Sqmm drawn through in and including non-metallic PVC rigid conduit of suitable size including all accessories including taking down old unserviceable / worn out sub main wiring of any type complete including making good of disturbed surfaces all as specified and as directed. Note :- 4 runs of 4 Sqmm conductor, one run of 4 Sqmm earth conductor and one run of PVC conduit shall be measured as one unit length.
M & L for Sub main wiring complete with four single core 6 Sqmm, 1100 Volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of one run of single core 6 Sqmm drawn through in and including non-metallic PVC rigid conduit of suitable size including all accessories including taking down old unserviceable / worn out sub main wiring of any type complete including making good of disturbed surfaces all as specified and as directed. Note :- 4 runs of 6 Sqmm conductor, one run of 6 Sqmm earth conductor and one run of PVC conduit shall be measured as one unit length.
Taking down carefully old unserviceable aluminium point wiring (light, fan, socket or power) complete and making good disturbed surfaces of wall, floor etc. complete all as specified and as directed.
M & L for point wiring of any length using approved colour coding as per IS with multistranded copper conductor 1.5 Sqmm (Nominal area), two single core, PVC insulated and unsheathed stranded FRLS H cable 1100 Volts grade, ISI - 694 marked drawn in PVC casing caping / PVC counduit of 25mm size heavy duty ISI marked including all accessories etc with PVC sunken boxes / Modular boxes including modular cover plate with frame suitable for mounting switches / sockets etc and PVC insulated stranded copper conductor 1.5 Sqmm (Nominal area) , single core FRLS H cable as earth conductor and connecting to common earth dolly and making good disturbed sufaces on wall/floor/roof complete all as specified and as directed for the following :-
(a) One light / fan point controlled by one, one way switch complete.
(b) One light point controlled by two, two way switch complete.
(c) One bell point / buzer point controlled by one bell push complete.
(d) One 3 pin 5 Amps switch socket outlet point controlled by one , one way switch on independent board complete.
(e) One 3 pin 5 Amps switch socket outlet point controlled by one , one way switch on the same board complete.
All as per Item No. 44 above but with multistranded copper conductor 2.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed multistranded FRLS H cable 1100 Volt grade ISI-694 marked for 3 pin, 15 Amps socket outlet on independent including PVC insulated multistranded copper conductor 2.5 Sqmm (nominal area) single core FRLS H cable as earth continuity conductor to common earth and connecting to earth dolly and making good disturbed sufaces on wall/floor/roof complete all as specified and as directed.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS H cable 1100 Volts grade,ISI marked in PVC rigid conduits heavy duty ISI marked totally concealed in wall/floor/roof including all accessories etc with modular sunken box boxes / Modular boxes including modular cover plate with frame suitable for mounting switches / sockets etc and PVC insulated stranded copper conductor 1.5 Sqmm (Nominal area) , single core FRLS H cable as earth conductor and connecting to common earth dolly and making good disturbed sufaces on wall/floor/roof complete all as specified and as directed for the following :-
(a) One light / fan point controlled by one, one way switch complete.
(b) One additional light point on the same switch circuit complete.
(c) One light point controlled by two, two way switch complete.
(c) One bell point controlled by one bell push complete.
(d) One 3 pin 5 Amps switch socket outlet point controlled by one , one way switch on independent board complete.
(e) One 3 pin 5 Amps switch socket outlet point controlled by one , one way switch on the same board complete.
All as per Item No. 46 above but with multistranded copper conductor 2.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed multistranded FRLS H cable 1100 Volts grade ISI-694 marked for 3 pin, 15 Amps socket outlet on independent, including PVC insulated multistranded copper conductor 2.5 Sqmm (nominal area) single core FRLS H cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed.
S & F MCB TP rated capacity 63 Amps, 415 Volts , breaking capacity 10 KA , 'B' curve complete all as specified and as directed.
S & F MCB TPN rated capacity upto 40 Amps, 415 Volts , breaking capacity 10 KA , 'B' curve complete all as specified and as directed.
S & F MCB SPN rated capacity 32/40 Amps, 240 Volts, breaking capacity 10 KA , 'B' curve complete all as specified and as directed.
S & F MCB SP rated capacity 5 to 32 Amps, 240 Volts , breaking capacity 10 KA , 'B' Curve complete all as specified and as directed.
S & F in replacement MCCB TP / TPN capacity 63 to 100 Amps with extended spreaded terminals , 415 Volts , breaking capacity 16 KA , complete all as specified and as directed.
Taking down the existing unserviceable main switch / DBs of any type / capacity / description and making good the disturbed surfaces to match with the existing finishes all as directed.
S & F sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar , 415 Volts, double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick / stone masonary etc and making good the distrubed surface to match with existing finishes complete all as specified and as directed.
S & F vertical type double door TPN DB 6 way IP-43 recess mounted / wall mounted type with including incoming MCCB 3 Pole, 25 KA, 100Amps - 01 No and outgoing MCB SP/SPN 32/40 Amps-18 Nos, suitable for single phase / three phase out going including including necessary provision for inserting the DBs in wall by cutting the brick / stone masonary etc and making good the distrubed surface to match with existing finishes complete all as specified and as directed. Note : Empty space shall be covered by blanking plate and connect with lugs without any extra cost to the department.
S & F sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 Volts , double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick / stone masonary etc and making good the distrubed surface to match with existing finishes complete all as specified and as directed.
All as per item No 56 above but MCB DB SPN 8 way complete all as specified and as directed.
All as per item No 56 above but MCB DB SPN 6 way complete all as specified and as directed.
All as per item No 56 above but MCB DB SPN 4 way complete all as specified and as directed.
All as per item No 56 above but MCB DB SPN 2 way complete all as specified and as directed.
S & F sheet metal enclosures single pole and neutral enclosure with a three pin and earth plug and socket complete with one MCB SP 20/32 Amps complete all as specified and as directed.
M & L for Servicing / testing of Metering indoor building Panels, 03/01 Phase, 415/230 Volts all as directed as per followings :- (i) Repair / replacement of damaged hinges and locks / latches of each compartment. (ii) Cleaning of existing bus bars with CTC applying with red solution, providing bus bar insulation and refixing with new nuts, bolts, washers etc. (iii) Replacement of damaged copper cable and fixing new copper cable for incoming and outgoing connections of each MCCB / MCBs switches alongwith lugs terminals to bus bars including connector. (iv) Replacement of damaged cable protection pipe and damaged / wornout cable insulation and lugs of any size for incoming & outgoing cables. (v) Replacement of neoprene gasket and transparent acrylic sheet 3 mm for all doors of panel board. (vi) Removing, cleaning and fixing/ refixing of elctric meter including connection of concerned qtrs complete. Note : Replacement of unserviceable MCCB/MCBs shall be measured & Paid separately.
M & L in replacement for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.50 metre deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel including GI pipe 15mm dia light grade protection upto the extent of 7.5 Mtrfor for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part-I including necessary excavation and earthwork in any type of soil / strata and testing on completion. Note :- GI earth wire 4mm dia and 15mm dia protection pipe upto 7.5 metre from earth plate is deemed to be included in quoted rates.
M & L in replacement 4mm dia galvanised iron or steel wire as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn through in conduit pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete all as specified and as directed.
Supply and fix in replacement 1100 Volts grade PVC round sheathed (flexible) industrial cable 3 core , 1.5 Sqmm nominal cross section alongwith conduit complete all as specified and as directed.
Supply and fix in replacement 1100 Volts grade PVC round sheathed (flexible) industrial cable 3 core , 2.5 Sqmm nominal cross section alongwith conduit complete all as specified and as directed.
Notes for item No 1 to 66 above :- :- (a) The contractor shall detail electrician with helper for attending door to door domestic electric complaints at various locations in defence area including checking serviceability of electric items as required at site and as directed. (b) Contractor will deploy electrician with helper to attend complaint in AFMC's Offrs /JCOs / ORs Md accn as well as in servant qtrs alongwith necessary tools, safety equipments and transportation required to attend complaint. (b) Complaint will be attended within 24 hours. (c) Electrician & Helper employed by contractor shall Possesses security pass all the time whenever on work shall be responsibility of contractor. (d) Subsequently sufficient store as required for execution of items as per BOQ shall be procured by the contractor for day to day complaints.
Akash Constructions
UNIQUE ENGINEERS
Anand Trading Co
ANUSHKA BUILDERS
Vishwas Electricals And Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .