Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹8.1 LAccepted-AOC PULGAON | 1st | Accepted-AOC Being a lowest bidder and reasonable rate quoted | |
| 2 | 2nd₹9.2 L+₹1.1 L (13.8%)Rejected-Finance | 2nd | Rejected-Finance Other than lowest tender | |
| 3 | 3rd₹9.7 L+₹1.6 L (20.2%)Rejected-Finance | 3rd | Rejected-Finance Other than lowest tender | |
| 4 | 4th₹9.8 L+₹1.7 L (21.3%)Rejected-Finance BHAWANI KRUPA GANDHI CHOWK PULGAON | PULGAON | WARDHA | MAHARASHTRA | 4th | Rejected-Finance Other than lowest tender | |
| 5 | 5th₹10.0 L+₹1.9 L (23.8%)Rejected-Finance | 5th | Rejected-Finance Other than lowest tender |
Tender Value
Refer Docs
EMD Value
₹16,200
Closing Date
13 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PULGAON
GE PULGAON CAD PULGAON
PROVN OF CARD BASED PREPAID ENERGY METER FOR PRIVATE PARTIES AT CAD PULGAON UNDER GE PULGAON
2021_MES_438329_1
8864/PUL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
3010 days
GE PULGAON
Asper tender documents
8 documents required · 8 mandatory
₹500
GE PULGAON
₹16,200
Yes
1 Jun 2021
24 Apr 2021
19 May 2021
24 Apr 2021
13 May 2021
8 May 2021
24 Apr 2021 - 5 May 2021
60 days
Amount
Supplying, Testing and commissioning Micro Processor Based, Single Phase Duel source Multifunction Energy Meter including Card, whole current 10/60A ( IS 13779 Standard ), with Inbuilt Default RS 485 & RF Recharge Facility, Electronic & Mechanical Tamper Proof, Including 2 way Communication for Disconnection & Reconnection facility of load, through Elnet Pro EMS & EBS Version 5.1 Web Based Software, by secured User Password login including necessary data cable all as specified and directed by Engr-In-Charge. Make:- Elmeasure Meter- PE5121 or eqvt in HPL/L&T
Supplying, Testing and commissioning Micro Processor Based, Three Phase Duel source Multifunction Energy Meter including Card, whole current 10/60A ( IS 13779 Standard ), with Inbuilt Default RS 485 & RF Recharge Facility, Electronic & Mechanical Tamper Proof, Including 2 way Communication for Disconnection & Reconnection facility of load, through Elnet Pro EMS & EBS Version 5.1 Web Based Software, by secured User Password login including necessary data cable all as specified and directed by Engr-In-Charge. Make:- Elmeasure Meter- PE5120 or eqvt in HPL/L&T
Supply and installation suitable size of wooden board for fixing meter on wall of any type complete all as specified and directed by Engr-In-Charge.
Supply and fixing Meter Enclosure box single / three phase meter for fixing on wall with adequate space for energy meter indoor cubical type wall mounted, vermin proof, dust proof, powder coated of suitable size for above meter fixing all as specified and directed by Engr-In-Charge.
Supply, Installation, Connecting & Testing Intel core i5 8th gen processer 8500 Q370 chipset motherboard (4 DIMM slot) 8 GB DDR 4 ram ( support up to 64 GB) 1 TB hard disk DVD RW 19.5 TFT monitor (E2016H) windows 10 professional keyboard & mouse 3 years warranty Make :- Dell/HP or equivalent
Supply, Installation, Connecting & Testing of line interactive external 180AH battery UPS 1KVA alongwith suitable UPS trolly and with the following technical specifications:- Input Voltage-220V AC/230V AC Voltage Range-140 to 300V AC Frequency Range-50Hz Make :- Canon/Epson or equivalent
Supply, Installation, Connecting & Testing Laserjet printer with single function black & white with USB connection with printing speed of min 18 pages per minute with resolution 600 x 600 x 2DPI complete all as specified and directed by Engr-in-Charge. Make :- HP, Model No:- P1108 or techno-commercially equivalent in Canon / Epson.
Supply and fixing (RF Card) for recharging of prepaid meter complete all as specified and directed by Engr-In-Charge. Make:- Secure/HPL/L&T/Elmeasure
Supply only additional Recharge Card as per specification match with above single and three phase meters all as specified and directed by Engr-In-Charge.
Material & Labour for maintenance and Servicing for next 06 years after 2 years of complition of defect liability period includes the following. (a) Computer, UPS, Battery, RF card for recharging meter i.e. Item Sr No. 01 to 08 (b) The contactor will provide through manufacturer training minimum 4 person of MES to handling the pre paid meter, maintenance, recharging and make them able to resolve possible defects in day to day maintenance. (c) The payment schedule will be at the end of the AMC period of one year commencing from the completion of two years of defect liability period after completion of phase -I BOQ items No 1.00 to 9.00. (d) AMC is also include all software hardware and related technology required to make serviacable item Sr No. 01 to 08 (e) AMC is included all spare parts related item ser No. 1 to 8 apart from physical damage. If physical damaged occured, the contractor shall born entire cost of meter.
SHRI RANI SATI TRADERS
SHUBHAM SALES AND ENGG WORKS
M/S JAI BHAWANI CONSTRUCTIONS
SHREE SIDDHIVINAYAK TRADERS
M/s MM TRADERS
Bidder Name
SHRI RANI SATI TRADERS
SHREE SIDDHIVINAYAK TRADERS
SHUBHAM SALES AND ENGG WORKS
M/S Maa Durga Constructions,Pulgaon
M/s MM TRADERS
M/S JAI BHAWANI CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .