Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAdmitted-Finance NO 84 METTUPALAYAM CHINNAPUTHUR DHARAPURAM TIRUPUR 638657 | TIRUPPUR | TAMIL NADU | 638657 | ₹2.7 L | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Sri Sellandiyamman Engineers and Constructions L1 |
|---|---|---|---|---|
| 1.00 | Excavation of Pole / stay pit for pole upto 8.00m length by using JCB/Manual.[ Pole - (1.25 x 0.6 x 1.5m), Stay - (0.95 x 0.6 x 1.2m).] | 1 | Per pit | 650 ₹650 |
| 2.00 | Excavation of Pole pit for pole above 8.00m length by using JCB/Manual (1.25 x 0.6 x 1.83m) | 1 | Per pit | 680 ₹680 |
| 3.00 | Excavation of Pole / stay set pit in Hard Soil (common to all size of poles). | 1 | Per pit | 500 ₹500 |
| 4.00 | Excavation of Pole / Stay pit in rocky area (common to all size of poles) by blasting / Manual. | 1 | Per pit | 600 ₹600 |
| 5.00 | Erection of RCC, REC, PSC poles upto 8.00m length by using Crane / Manual | 1 | Per pole | 720 ₹720 |
| 6.00 | Erection of RCC, REC, PSC poles above 8.00m length by using Crane / Manual | 1 | Per pole | 800 ₹800 |
| 7.00 | Erection of metal supports above 9m / RSJ / Rail Pole/Tubular Poles | 1 | Per pole | 770 ₹770 |
| 8.00 | Erection of stay set complete with fixing up stay wire Eye, Bow, Guy Shackle, Binding etc. | 1 | Each set | 650 ₹650 |
| 9.00 | Erection of additional Stay in the same stay rod, excluding excavation of stay pit and burial of stay rod. | 1 | Each set | 100 ₹100 |
| 10.00 | Erection of stay set complete in the rock area by blasting | 1 | Each set | 100 ₹100 |
Tender Value
₹15 L
EMD Value
₹15,000
Closing Date
19 Jan 2026, 3:00 pmClosed
The superintending Engineer Palladam EDC
O/o.The Superintending Engineer/TNPDCL,Palladam EDC,56 B, GT Building, TrichyRoad,Palladam 641 664
HT LT line erection works in Mulanur Sub division
2026_EB_642663_1
Spec.No.75/2025-26 dt.09.01.2026
Open Tender
Electrical Works
365 days
Mulanur sub div
2 documents required · 2 mandatory
₹0
₹15,000
Yes
3 Feb 2026
12 Jan 2026
20 Jan 2026
12 Jan 2026
19 Jan 2026
12 Jan 2026
12 Jan 2026 - 19 Jan 2026
Excavation of Pole / stay pit for pole upto 8.00m length by using JCB/Manual.[ Pole - (1.25 x 0.6 x 1.5m), Stay - (0.95 x 0.6 x 1.2m).]
Excavation of Pole pit for pole above 8.00m length by using JCB/Manual (1.25 x 0.6 x 1.83m)
Excavation of Pole / stay set pit in Hard Soil (common to all size of poles).
Excavation of Pole / Stay pit in rocky area (common to all size of poles) by blasting / Manual.
Erection of RCC, REC, PSC poles upto 8.00m length by using Crane / Manual
Erection of RCC, REC, PSC poles above 8.00m length by using Crane / Manual
Erection of metal supports above 9m / RSJ / Rail Pole/Tubular Poles
Erection of stay set complete with fixing up stay wire Eye, Bow, Guy Shackle, Binding etc.
Erection of additional Stay in the same stay rod, excluding excavation of stay pit and burial of stay rod.
Erection of stay set complete in the rock area by blasting
Replacement of stay rod only. (Including stay pit excavation & refilling & erection)
Replacement of guy shackle only in existing stay
Set right of all sizes of leaning HT/ LT poles [Pin point]
Set right of all sizes of leaning HT/ LT poles [Cut point]
V cross arm 3.5 feet
V cross arm 4.5 feet
V cross arm 5.0 feet
Fixing of LT S phase cross arm
Fixing of LT 3 phase cross arm
Fixing of Tapping Channel Cross Arm
Fixing of Guarding Cross Arm
Fixing of Double channel-X-Arm
Fixing of HT / LT Ti fitting
Fixing of HT PIN insulator with Pin 11 kv
Fixing of HT PIN insulator with Pin 22 kv
Fixing of HT PIN insulator with Pin 33 kv
Fixing of LT PIN insulator
Fixing of HT strain disc 11 KV
Fixing of HT strain disc 22 KV
Fixing of HT strain disc 33 KV
Fixing of shackle
Fixing of Aluminium knob
Fixing of open type fuse unit
Providing of line spacers in LT lines 1 phase
Providing of line spacers in LT lines 3 phase
Fixing of LT capacitor
Fixing of HT LAS (3 Nos.)
Fixing of LT LAS (3 Nos.)
Guarding Arrangement - Flat guarding with earth pit
Guarding Arrangement - Split neutral
Paving and stringing of conductors of sizes upto 7/2.59 mm ACSR or other equivalent conductor.
Paving and stringing of conductors of above 7/2.59 mm ACSR or other equivalent conductor upto 7/3.35mm ACSR or other equivalent conductor.
Paving and stringing of conductors of 7/4.09mm ACSR or other equivalent conductor.
Paving and stringing of conductors of 7/4.72 mm Dog Conductor or other equivalent conductor.
Paving and stringing of conductors of one run of PVC cable line of all sizes with GI wire and reel insulator.
Releasing and reerection (only for resagging) of one run of all sizes of conductor.
Resagging of lines for all sizes at cutpoint location per wire / span.
Earthing of poles with GI wires 4 or 6 SWG by coil earthing
Provision of spike including earthing arrangement
Pipe earthing including excavation of earth pit and fixing earth pipe 3 m length
Replacing the corroded earth pipes of transformer structure and replacing the earth wire completely with aluminium lugs for termination
Replacement of corroded earth pipe
Mass concreting of poles (0.6 x 0.6 x 1.25 m) wih coping.
Sleeve concreting (0.6 x 0.6 x 0.3 m) wih coping.
Stay concreting (0.3 x & 0.75m long).
Erection of Distribution Transformer structure complete as per TNEB standard including painting, feeders arrangrment, colour washing of RCC poles etc.. Fixing of 1 No. open type unit, 3 Nos Earth pits with earth trough, HT / LT LAS and jumpering except erection of Distribution Transformer.
Erection of 11 KV single pole Structure including erection of DT complete with centre support.
Erection / Dismantling of Distribution Transformer including unloading of Distribution Transformer at site and erection at structure or vice versa. By JCB/ Crane. i) Upto 25 KVA Distribution transformer / Metering set.
ii) Above 25 KVA to 100 KVA
iii) Above 100 KVA to 250 KVA
iv) 500 KVA and above
Erection of DP structure with stay as per TNEB standard including fixing of top channel, cross bracing, concreting, painting, colour washing etc., i) With 11 KV AB switch using all types of poles of size 9.14m and above length
ii) With 22 / 33 KV AB switch using all types of poles of size 9.14 m and above length
Erection of single pole DP with complete and with single earth
Erection of centre rotating Switch AB Switch complete
Intergrater DT Metering Arrangements/ Whole Current Meter
Dismantling of 1068 mm (3'6") V-X-Arm
Dismantling of 1372 mm (4'6") V-X-Arm
Dismantling of 5' V-X Arm
Dismantling of 1ph X -Arm
Dismantling of 3ph X -Arm
Dismantling of Tapping channel x arm
Dismantling of Guarding Cross Arm
Dismantling of Double Channel X-Arm
Dismantling of H.T/L.T. T.I. Fitting
Dismantling of 11kv PIN with insulator
Dismantling of 22kv PIN with insulator
Dismantling of 33 KV Pin Insulator
Dismantling of LT Pin with Insulator
Dismantling of 11kv Composite Disc with Mp
Dismantling of 22kv Composite Disc with Mp
Dismantling of 33 KV Disc
Dismantling of LT Shackle with Mp
Dismantling of Aluminium knob
Dismantling of LT open type
Dismantling of HT LAS (3 nos)
Dismantling of LT LAS (3 nos)
Dismantling of Top channel
Dismantling of Bed channel
Dismantling of Belting channel
Dismantling of RCC, REC, PSC & metal pole of all sizes including the closing of the pit
Dismantling of stay set complete including stay rod
Dismantling of stay set complete without stay rod
Dismantling of 7/2.59 conductor including transporting the conductors to the nearest road side and stocking in coils
Dismantling of 7/3.35 conductor including transporting the conductors to the nearest road side and stocking in coils
Dismantling of 7/4.09 conductor including transporting the conductors to the nearest road side and stocking in coils
Dismantling of Dog conductor including transporting the conductors to the nearest road side and stocking in coils
Dismantling of Double pole Transformer structure materials complete set and transporting the same from the location to the road side
Dismantling of Single pole Transformer structure materials complete set and transporting the same from the location to the road side
Engaging Crane per Hour (for handling of poles, Metering set,DT etc)
Engaging JCB per Hour (for extension works & maintenance works etc)
MISCELLANEOUS WORKS : Releasing and erection 1 ph SC wire [during conductor or support change]
Releasing and erection 3 ph SC wire [during conductor or support change] Upto 50 HP
Releasing and erection 3 ph SC wire [during conductor or support change] above 50 HP
Provision of Street light, switching arrangement including fixing of meter, wiring & service board etc.,
Fixing of one set of street light fixture with clamp and fitting of all sizes including cable jumpering and including transportation
Retrieving grill from Deteriorated RCC pole
Erection of MV/Sodium Vapour Lamps including wiring and fixing at street light location including transportation
Manufacturing / Altering of Clamps
Drilling of holes in the structure materials clamps etc.,
AB switch or open type side arm stud, cutting and drilling holes
Manufacturing of earth pipe clamps for structure including of drilling holes and welding and clamp with earth pipe.
Clearing of tree braches of coconut trees
Clearing of tree braches of Neem, Tamarind, Country wood etc
Leveling of Ground using Bul Dozer
Clearing of Branches / Trees with JCB
Fencing of Distribution Transformer Structure at Road side- Fabrication and Erection.(including all materials)
Maintenance of Distribution Transformer including checking tightness, reconditioning of HG fuse,cleaning of insulators, reconditioning of LT open type,replacement of damaged bushing clamp,topping of transformer oil, bus bar maintanence / renewal / AB switch maintanance,yard cleaning, earth pit watering,silica gel replacing and other related works.
Maitenance of 11 / 22 KV AB Switch with all accessories (Applying Greese, Alignment Checking etc.,)
Maitenance of existing LT Open type Fuse Unit in Distribution Transformer (Replacement of Insulators, Jumbers etc.,)
Maitenance of existing Distribution Transformer Bus bar (Replacement of Bus bar conductors,Insulators, Jumbers and etc.,)
Maitenance of existing Distribution Transformer HG Fuse set assembly ( Replacement of Insulators, Arc Horn etc.,)
BREAKDOWN (Labour can be engaged for the following works due to non availability of sufficient staff in presence of Foreman/LI) Ground patrolling of HT /LT lines during Breakdown
Rectification of conductor snapping in HT line Pin point / cut point
Rectification of conductor snapping in HT line cut point
Rectification of conductor snapping in LT line Pin point / cut point
Rectification of conductor snapping in LT line Cut point
Replacement of Flashover HT pin insulator/LAS including jumpering,binding and transporting of required materials
Replacement of Flashover LAS including jumpering,binding and transporting of required materials
Replacement of Flashover strain disc and PT insulator including jumpering,binding and transporting of required materials
Tiding of service connection with erection of clamp jumper in low tension SC/Line aerial Board, Fuse unit and looping
Renewal of jumper from 22/11 kv line to AB Switch to HG Fuse, HG Fuse to Distn. Transformer with PG Clamps
Inspection of HT Insulator / Disc /PT Insulator pole to pole during break Down / routine and premonsoon inspection.
TRANSPORTATION CHARGES: Transportation of all types and sizes of poles and other associated materials from Road side to pole pit and vice versa upto 0.50 KM
Transportation of all type of poles by bullock cart or other vehicle (for all sizes of poles including loading and unloading) i) For a lead upto 5 KM
ii) Above 5 KM of lead of every KM
Transport of Metal pole of all sizes by head loads in hill areas from road side to pole pit location i) Upto 1 KM
ii) Above 1 KM per each KM
Transporting of conductors of all sizes from road side to pit locations upto one KM of Conductor
Transporting of Distribution Transformer / Line materials from stores to office / site by engaging 1 Ton capacity Minidor (Lorry) i) upto 10 KM distance
ii) Above 10 KM
Loading or unloading of Distribution Transformer i) Upto 100 KVA
ii) Above 100 KVA and upto 500 KVA
iii) Metering set of all ratios
Loading of various sizes of poles i) REC, RCC, PSC pole upto 8.00 m length
ii) All REC, RCC pole above 8.00 m length
iii) Metal poles all sizes
Unloading of various sizes of poles i) REC, RCC, PSC pole upto 8.00 m length
ii) Unloading of All REC, RCC pole above 8.00 m length
iii) Unloading of Metal poles all sizes
Sub Total
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.56 MB
BOQ_769960.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid