| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹7.3 L
Closing Date
22 Nov 2021, 4:00 pmClosed
Estates Officer
Estates Division SKUAST Jammu Main Campus Chatha
Construction of shelves and sale counter in the Pulse Seed Hub store near Mega Seed Project at Chatha
2021_SKUST_146091_4
AU/Estates/21-22/25 dated 01-11-2021
Open Tender
Civil Works
Item Wise
90 days
Main Campus Chatha
Please refer tender documents
4 documents required · 4 mandatory
₹500
Assistant Comptroller Estates SKUAST Jammu
Exempted
29 Nov 2021
1 Nov 2021
23 Nov 2021
3 Nov 2021
22 Nov 2021
3 Nov 2021
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering. All work upto plinth level.
1:3:6 (1 Cement : 3 coarse sand(zone-III) : 6 graded stone aggregate 20 mm nominal size) (using 30 % boulders including cost and carriage of boulders)
1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete.
Suspended floors, roofs, landings, balconies and access platform.
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts.
Edges of slabs and breaks in floors and walls.
Under 20 cm wide
Weather shade, Chajjas, corbels etc., including edges.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Cold twisted bars
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:6 (1 cement : 6 coarse sand)
Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level for each four floors or part thereof by mechanical means.
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in.
Cement mortar 1:4 (1 cement : 4 coarse sand)
Extra for half brick masonry in superstructure, above floor V level for every four floors or part thereof by mechanical means.
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.
Second class teak wood
35 mm thick
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws:
35 mm thick shutters.
with ISI marked M.S. pressed butt hinges bright finished of required size - Second class teak wood
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
Fixed to steel windows by welding.
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :
Providing and fixing aluminium casement stays ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.
Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
Using M.S. angels 40x40x6 mm for diagonal braces
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
40 mm thick with 20 mm nominal size stone aggregate
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
25 mm thick.
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat :
With common burnt clay F.P.S.(non modular) brick tile of class designation 10.
Extra for every additional 1 cm thickness of mud phaska
Providing gola 75x75mm in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3(1 cement : 3 fine sand) as per standard design
In 75x75mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400 micron, finished with 12mm cement plaster 1:3 (1 cement :3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
12 mm cement plaster of mix : inside plaster
1:6 (1 cement: 6 coarse sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement: 3 coarse sand) finished rough with sponge. Outside plaster
6 mm cement plaster of mix : in ceiling
1:3 (1 cement: 3 fine sand)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade.
New work (two or more coats) over and including water thinnable priming coat with cement primer.
Finishing walls with water proofing cement paint of required shade :
New work (Two or more coats applied @ 3.84 kg/10 sqm).
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. : Internal work – Exposed on wall.
20 mm dia. nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. : External work
20 mm dia. nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
20 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work)
20 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931:
15 mm nominal bore.
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
15 mm nominal bore
Providing & fixing of the following sanitary items:-
PVC pipe:-
110 mm dia
75 mm dia
Providing and laying river bed material comprising of sand , stone boulders, earth etc. complete including consolidation, watering, carriages, loading and unloading etc
SUB-DISTRIBUTION BOARDS
Providing and fixing 6 amps to 32 amps rating 240 volts, 'L' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as reqired (category B)
Single Pole - 6 to 32 A
Supply and fixing of following rating, 2P 230 volts, SPN in the existing MCB DB complete with connections, testing and commissiong etc. as required
40 amps SPN
SUB-DISTRIBUTION BOARDS
Supply and fixing of the following way, single pole and neutral / t sheet steel, double door, phase segregation type, MCB distribution board, 230V on surface/recess, complete with tinned copper bus bar, neutral bus bar and link, earth bar, din bar, detachable gland plate, interconnections, including painting, earthing, etc., as required.
12 way APN
Supply and fixing 1x20 watt box type fitting complete with extruded alulminium tube rod including connection testing etc. as reqd.
Wiring for light / fan / exhaust fan / call bell point with 1.5 Sq mm FR PVC insulated copper conductor cable in surface / recessed ISI marked PVC conduit(2mm thick) including concealed box 6 inch and providing 5 amp switch and earthing complete as required.
Light point on board with copper wiring in ISI marked PVC conduit wiring for 3 Pin 6 amp plug point with 1.5sqmm PVC insulated multistrand copper conductor cable including P/F of 3 Pin 6 amp socket outlet on switch board in surfaced recessed PVC conduit wiring system and 6 amp switch, earth the 3 pin as required with 01 No. PVIC insulated green colour wire.
Wiring for light plug with 2 x 2.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x 0.75 mm copper wire for loop earthing required
Wiring for power plug with 2 x 4 sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x0.75 Sq mm copper wire for loop earthing as required
Wiring for 1x 1.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked in the existing PVC conduit etc. as required ( Invertor wiring )
Wiring for sub main wiring with following sizes of PVC/ insulated copper conductor wires in the surface/ recessed PVC / MS conduit along with PVC insulated copper conductor earth wire as required complete with connections, testing and commissioning etc. as per specifications and drawings.
2x6 sq mm
Supplying and fixing metal box of 180 x 100 x60mm deep in recessed with suitable size phoenolic laminated sheet cover in the front including providing and fixing 3 pin 15Amp socket outlet and 15Amp switch connections, painting etc. as required. (Power plug)
Supply and fixing step up electronic fan regulator on the existing switch box including connecting testing etc. as required.
Supply and fixing 20 Amp Industrial socket with 32 Amp SPN including connection, testing, etc. as required
Ravinder kumar Sharma
Sahil Sharma
Ratinder Singh
AMIT SHARMA
M/S VIJAY KUMAR CHOUDHARY
Laxman Singh
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .