Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹25.7 LAccepted-AOC 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹30.8 L+₹5.1 L (19.8%)Rejected-Finance | L-2 | Rejected-Finance other than L-1 | |
| 3 | L-3₹31.9 L+₹6.2 L (24.0%)Rejected-Finance | L-3 | Rejected-Finance other than L-1 | |
| 4 | L-4₹32.0 L+₹6.2 L (24.2%)Rejected-Finance | L-4 | Rejected-Finance other than L-1 | |
| 5 | L-5₹34.4 L+₹8.6 L (33.6%)Rejected-Finance | L-5 | Rejected-Finance other than L-1 |
Tender Value
₹28.6 L
EMD Value
₹57,200
Closing Date
1 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh A K Dubey IDSE SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
ADDITION/ ALTERATIONS TO POWER SUPPLY SYSTEM OF HQ NC UNDER GE(UTILITY) UDHAMPUR
2022_MES_513091_2
CA NO CWE/U(U)-114/2021-22
Open Tender
Civil Works
Item Rate
180 days
UDHAMPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE(UTILITY) UDHAMPUR
₹57,200
14 Jun 2022
12 May 2022
3 Jun 2022
12 May 2022
1 Jun 2022
19 May 2022
60 days
Amount
Supply and ererction in vertical position Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate (300mmx300mm), welded to pole, B-118 finial taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-55 (11 m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome primer and two coats of black bitumenous paint internally & portion embedded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed. Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely.
M&L for MS work cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections ( flat, angle, channel) including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one coat of red oxide primer, one under coat and one finishing coat of aluminium paint, complete all as specified and directed by Engr-in-Charge.
Supply and fix Pin/ disc / shackle type, porcelain , vitreous, white, brown or green insulator including one galvanised mild steel spindle . Two galvanised iron washers and one galvanised iron nut , 150 mm height , 150 mm dia for 11000 volts grade complete all as specified and directed by engineer-in-charge.
Supply , installation testing & commissioning of maintenance free earth electrode of size 100mm dia X 3000mm long with 17.2 mm Cu bonded MS Conductor pre cast or in situ cast in high purity electrically conductive granular material having ultra low resistive value of 0.001 ohm-m. electrode made of conductive earth enhancing material mixed with cement in ration of 3:1 encase or backfill the voids sourrounding the 17.2 mm Cu bonded MS Conductor or other metal components placed in augured bore hole of 100mm dia X 3000mm depth ,resulting to increase in the effective surface area of the earth electrode or grids to lower the resistance. Earth enhancing material should not leach chemicals into the adjacent soil or underground water channels and should be pH neutral range. Earth enhancing material should be permanently protect the encased metal components of the earthing systyem. Copper bonding on MS rod should be minimum 250 microns. all hardware like nuts , bolts and washers should be of stainless steel. electrode should withstand fault current up to 35ka for 1 sec. electrode top terminal is sealed permanently packed with conductive concrete and Cu bonded MS/Copper strip taken out be terminated on to earth test point and equipped terminal. test certificate of NABL laboratory shall be submitted by the contractor, test link of size 500mmx 6mmx 200mm , RCC Pit cover including brazing of all the joints up to the test point complete all as specified and directed by engineer-in-charge Make of electrically conuctive material : Marconite/ITPC Met-chem/ Kratonite.
M&L for earth continuiy conductor or main earthing lead fixed to wall or recess or buried in ground in conduit / pipe or fixed to poles or any other indicated situiation for loop earthing etc. as required with 20mm x 3 mm copper strip complete wih and including brazing of copper strips and earthing insulators fixed to walls complete all as specified and as directed by Engr-in-Charge.
Supply , lay and stringing of ACSR Conductor , Aluminium conductor reinforced with steel including various acessories like line connectors , line taps and compression joints wherever required including streching, tightining of poles insulator with winding wire of suitable size with insulator/streching of ACSR conductor complete all as specified and directed by Engr-in-Charge.
Supply and fix voltage stabiliser outdoor type for automatic operation three phase naturally oil cooled outdoor type & designed for input variation between 340 V to 460 V with out put voltage stabilized at 415 V with accuracy +- 2.5% and speed of correction 8 volts per second and of capacity 250 KVA etc complete all as specified and directed by Engr-in-Charge. Notes : (i) Pre- commissioning inspection of Stabilizer shall be carried out by Electrical inspector and T&P for the inspection shall be arrange by contractor, cost of the T&P etc for testing shall deemed to be included in the unit rate. (ii) Construction of plinth for Stabiliser 2 mtr height x 2.5 mtr width x 2.5 mtr length including morum filling and PCC at top 10cm thick (1:2:4) and PCC foundation with 1:4:8(80cm width x 2.7 mtr length in square foundation 25cm Height all as per drawing provided by the department including plastering to exposed walls and white wash. Providing MS Channel on top of size 75x40x8 mm of 1.5 mtr in lenght for rolling to transformer including chain link fencing of wire mesh 150x 100 size made out of GI Wire of height 1.5 mtr fixed with the help of MS Strip 25x6 mm and including MS angle 75x45x6mm thick nos post by means of drilling holes at the distance of 30 cm and fixed with the help of suitable nut, bolt and washer .
Notes for Item 7 (Contd....) (ii) The length of the MS angle iron not less than 2.25mtr , top of the pad to the shape of 60degree including 3 nos for inserting barbed wire including 03 runs of barbed wire and including provision of gate of size 1.5mx 0.9mtr made out of MS angle iron 50x 50x6 mm and MS bar 12 mm dia for meshing the gate and locking arrangements including PCC goundation 1:2:4 type B-1 for posts complete all as specified and directed by Engr-in-Charge shall deemed to be included in the unit rate. (iii) Provision of 4 no rubber mats Synthetic 2mx1mx0.5m at near the surfaces of Plinth/platform of stabilizer shall deemed to be included in the unit rate. (iv) Necessary chain link fencing required around Stabiliser shall deemed to be included in the unit rate.
Suppy, installing, connecting, commissioning and testing of energy effficient transformer (level 3 of IS 1180) of capacity 250 KVA outdoor type powder coated, step down 11/0.433 KV, core type oil immersed, copper wound, natural oil cooled with external cooling tubes, having 3 phase 50 Hz, AC supply, DYN-11 design, off load tap changer on HT side to vary secondary voltage ±7.5% in steps of 2.5% as per IS 1180 (Pt-I to III) with all standerd accessories including HT and LT bushing LT box on LT side, including inbuilt protection and first filling of transformer oil (of die electric strength not less than 50 KV) upto required level in conservator tank with cover boxes, dial type thermometer, rollers, stop taps, breather with silica gel, conservator tank, oil level indicator, etc, complete all as specified and as directed by Engr-in-Charge. Note :(i) The transformer oil shall be fresh and approval certificate from manufacturer shall be obtained by contractor and furnished to GE. the copper shall be 99.97% purity and approval certificate from manufaturer shall be obtained by contractor and furnished to GE. (ii) Pre -commisioning, inspection of transformer shall be carried out by rep of Accepting offr and T&P for the inspection shall be arrange by contractor, cost of the T&P etc for testing shall deemed to be included in the unit rate.
Notes for Item 9 (Contd....) (iii) Construction of platform for transformer 2 mtr height x 2.5 mtr width x 2.5 mtr length including morum filling and PCC at top 10cm thick (1:2:4) and PCC foundation with 1:4:8(80cm width x 2.7 mtr length in square foundation 25cm height all as per drawing provided by the department including plastering to exposed walls and white wash. Providing MS Channel on top of size 75x40x8 mm of 1.5 mtr in length for rolling to transformer including chain link fencing of wire mesh 150x 100 size made out of GI Wire of height 1.5 mtr fixed with the help of MS Strip 25x6 mm and including MS angle 75x45x6mm thick nos post by means of drilling holes at the distance of 30 cm and fixed with the help of suitable nut, bolt and washer . The length of the MS angle iron not less than 2.25mtr , top of the pad to the shape of 60degree including 3 nos for inserting barbed wire including 03 runs of barbed wire and including provision of gate of size 1.5mx 0.9mtr made out of MS angle iron 50x 50x6 mm and MS bar 12 mm dia for meshing the gate and locking arrangements including PCC goundation 1:2:4 type B-1 for posts complete all as specified and directed by Engr-in-Charge shall deemed to be included in the unit rate. (iv) Provision of 4 no rubber mats Synthetic 2mx1mx0.5m at near the surfaces of Plinth/platform of transformer shall deemed to be included in the unit rate. (v) Necessary chain link fencing required around transformer shall deemed to be included in the unit rate. (vi) After completion of work all T&P used for opening, handling of transformer should be handed over to site-in-charge complete all as directed by engineer-in-charge.
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm complete, all as specified and directed by Engineer-in-Charge.
Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm complete, all as specified and directed by Engineer-in-Charge.
Supply, laying, commissioning and testing in replacement XLPE insulated screended PVC bedded galvanised steel strip or wire armoured electric power (Heay duty) with aluminium condutor 11000 volts (earthed) grade cross sectional area 120 sqmm 3 core cable in trenches, jointing with proper lugs, cable gland complete all as specified and directed by Engr-in-Charge. Note: Tagging of cable (like size, location from & to etc. ) must be embossed. Contractor's quoted rates shall be deemed to be inclusive of this aspect.
Supplying, laying, jointing, testing or fixing or passing through pipe, trench or duct, commissioning and testing new XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 Volt, cross-sectional area size 240 Sqmm, 3.5 core complete all as specified and directed by Engr-in-Charge. Note: Tagging of cable (like size, location from & to etc. ) must be embossed. Contractor's quoted rates shall be deemed to be inclusive of this aspect.
Supplying, laying, jointing, testing or fixing or passing through pipe, trench or duct, commissioning and testing new XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 Volt, cross-sectional area size 400 Sqmm, 3.5 core complete all as specified and directed by Engr-in-Charge. Note: Tagging of cable (like size, location from & to etc. ) must be embossed. Contractor's quoted rates shall be deemed to be inclusive of this aspect.
Excavation in trenches in any type of soil not exceeding 1.50 m wide and not exceeding 1.50 mtr in depth and getting out for pipe, cable pole, stay etc, complete all as specified and directed by engineer-in-Charge.
Returning filling in (soil) including spreading leveling watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed by engineer-in-Charge.
Removal of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by engineer-in-Charge.
M&L plain cement concrete 1:4:8 type D-2 as in foundations filling and mass concrete using 40mm graded stone aggregate complete all as specified and directed by engineer-in-Charge.
M&L plain cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate for coping of poles incl all necessary form work complete all as specified and directed by engineer-in-Charge.
S&F double walled corrugated (DWC) pipe of size 120 x 103 mm including snap fit coupler and any additional attachments suitable for DWC pipe , conforming to IS:14930 (Pt-II)/IS-16205 Pt-II for protection of HT/LT cable 95/400/185 sqmm in under ground complete all as specified & directed by Engineer-in-charge.
Material and labour for road cutting for laying of HT/LT Cables / Pipes and making good the distrubued surfaces as equal to existing road finishes including refilling the excavated material, compacting , WBM and black top carpeting with biutemen & aggregate all as specified & directed
Material & labour for switch air break, gang operated triple pole, mechanically operated, mounted on insulators and steel frame with operating mechanism worked from ground level for current rating up to 400A for working pressure 11000 volts with drop out type fuses three No of 40 amp capacity complete all as specified & directed by Engineer-in-charge.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .