Group D: Pathology Fully Automated Computerized Archival System for Histopathology & Cytology slides and Blocks Gas Chromatograph with Headspace Sampling system LC-MS/MS Triple Quadrupole Mass Spectrometer Gel Imaging System Mcrowave Multifunctional Tissue Processor Cold Plate Stoarge Cabinet for Specimens Bone Cutter Tissue Floating Bath Slide warming table Electron Microscope Tissue Microarrayer
143763
NIT No.25/2026-2027/Bio-Medical Eqpt/IGIMS/Store/D
Open Tender
GENERAL
Sheikhpura
• Status of Bidder:
? Manufacturer or Authorized Agent of the Manufacturer
? Whether Public Undertaking, Public Ltd., Private Ltd. Company or Proprietary Firm/partnership firm
(Please attach Notary certified MANUFACTURER?S AUTHORISATION FORM as per FORMAT placed at Annexure ? III)
• Power of Attorney as per Annexure - V in favour of person to sign, submit and negotiate the bid.
• Certificate towards market standing of minimum 05 years in the area of supply, installation, commissioning and maintenance of IT Equipment?s.
• Certificate for sole ownership / partnership
• Statement of financial standing from bankers
• Statements of turnover per year for last three successive years duly certified by the Chartered Accountants.
• Notary certified User List (List of Govt./Semi Govt., Reputed Pvt. Hospital) where quoted model of the items has been supplied and installed.
• Notary certified Supply order copy (Minimum 3nos. or more) issued by Govt. /Semi Govt. /Reputed Pvt. Institutions/organization for the quoted items.
• Notary certified Performance certificate of the same supplied machine (of quoted make and Model) issued by Head of the dept. or Institution after a minimum period of six months of installation
• Prerequisite (if any) for installation of the Machine, if any, to be provided by the Institute.
• Whether rates quoted are inclusive of all taxes or not.
• Whether rates are quoted as per format mentioned in the Bidding Document or not.
• Affidavit to the effect that the bidder is not blacklisted by any Govt. agency or has no pending case either Civil or Criminal against them.
• Affidavit, to the effect that the bidder is not supplying the quoted item(s) to any other Govt. /Semi Govt. Organizations / Institutions / Hospitals at the rate lower than the rate quoted against this tender.
• Bid Security amount deposited is enclosed or not. If yes, please mention the details.
• Original Technical Catalogue of the quoted model.
• Certificate, to the effect that bidder will maintain the quoted item(s) during Warranty period of five years as mentioned against each item including all spares, accessories, consumables etc., (Please mention the name of the item / items with price, which are not supplied by the bidder free of cost with frequency of replacement)
• Certificate, to the effect that bidder has quoted its rate for Comprehensive Annual Maintenance Contract inclusive of labour, spares, consumables, accessories etc. on per year basis for a further period of five years after expiry of warranty period of five years in the price bid.
(Please mention the name of the item / items with price, which are not supplied by the bidder free of cost with frequency of replacement during Comprehensive Annual Maintenance Contract period in the price bid)
• Acceptance of all terms / conditions towards after sales / services as mentioned in the bidding document. (Clause No- 13 of ?Instruction to Bidder ?& clause no- 3, 4 and 5 of Condition of contract.)
• Compliance Statement with relation to the technical specification as mentioned in the bidding document duly supported by the original catalogue. The bidder must quote specification in the compliance column Mere writing? Complied shall not be accepted.
• Compliance Statement with relation to the terms & conditions as mentioned in the document.
• PAN and copies of Income Tax Returns for the last three years.
• Duly attested copy of GST registration certificate.
• Should have OEM authorization against this tender.
GENERAL
ITEM RATE
L1
1
21 documents required · 21 mandatory
₹2,500
Processing Fee: 1180
Conference Hall (Ground Floor, New Administrative Building), IGIMS, Patna
20 Nov 2026
20 Nov 2026
28 Dec 2026
20 Nov 2026
23 Dec 2026
20 Nov 2026
27 Nov 2026
180 days
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 25/2026-2027/Bio Medical Equipt /IGIMS/Store
A.: To be filled by the bidder and submitted along with the Technical Bid.
Sl. No. Terms & Conditions as per Bidding Document Page No. Remarks
1 Status of Bidder:
· Manufacturer or Authorized Agent of the Manufacturer
· Whether Public Undertaking, Public Ltd., Private Ltd. Company or Proprietary Firm/partnership firm
(Please attach Notary certified MANUFACTURER’S AUTHORISATION FORM as per FORMAT placed at Annexure – III)
2 Power of Attorney as per Annexure - V in favour of person to sign, submit and negotiate the bid.
3 Certificate towards market standing of minimum 05 years in the area of supply and or maintenance of bio-medical equipments.
4 Certificate for sole ownership / partnership
5 Statement of financial standing from bankers
6 Statements of turnover per year for last three successive years duly certified by the Chartered Accountants.
7 Notary certified User List (List of Govt.
/Semi Govt., Reputed Pvt. Hospital) where quoted model of the items has been supplied and installed.
8 Notary certified Supply order copy (Minimum 3nos. or more) issued by Govt./Semi Govt.//Reputed Pvt. Institutions/organization for the quoted items. ( same model)
9 Notary certified Performance certificate of the same supplied machine (of quoted make and Model) issued by Head of the deptt. or Institution after a minimum period of six months of installation
10 Prerequisite (if any) for installation of the Machine, if any, to be provided by the Institute.
11 Whether rates quoted are inclusive of all taxes or not.
12 Whether rates are quoted as per format mentioned in the Bidding Document or not.
13 Affidavit to the effect that the bidder is not
blacklisted by any Govt. agency or have no pending case either Civil or Criminal against them.
14 Affidavit, to the effect that the bidder is not supplying the quoted item(s) to any other Govt. / Pvt. Organizations / Institutions / Hospitals at the rate lower than the rate quoted against this tender.
15 Quality Assurance Certificate like ISI, ISO-9002, IP/BP, CE, FDA (US) or any other (please specify)
16 Bid Security amount deposited is enclosed or not. If yes, please mention the details.
17 Original Technical Catalogue of the quoted model
18 Certificate, to the effect that bidder will maintain the quoted item(s) during Warranty period of five years including all spares, accessories, consumables etc.,
(Please mention the name of the item / items with price, which are not supplied by the bidder free of cost with frequency of replacement)
19 Certificate, to the effect that bidder has quoted its rate for Comprehensive Annual Maintenance Contract inclusive of labour, spares, consumables, accessories etc. on per year basis for a further period of five years after expiry of warranty period of five years in the price bid.
(Please mention the name of the item / items with price, which are not supplied by the bidder free of cost with frequency of replacement during Comprehensive Annual Maintenance Contract period in the price bid)
20 Acceptance of all terms / conditions towards after sales / services as mentioned in the bidding document.( Clause No- 13 of “ Instruction to Bidder “ & clause no- 3, 4 and 5 of Condition of contract.)
21 Compliance Statement with relation to the technical specification as mentioned in the bidding document duly supported by the original catalogue. The bidder must quote specification in the compliance column Mere writing” Complied shall not be accepted.
22 Compliance Statement with relation to the terms & conditions as mentioned in the document.
23 PAN and copies of Income Tax Returns for the last three years.
24 Duly attested copy of GST registration certificate.
B: To be filled by the Bidder and submitted along with Price Bid
Sl. No. Terms & Conditions as per Bidding Document Page No. Remarks
1 Item wise price for the item(s) as mentioned in the Bidding Document and as per format attached as Annexure – I(a) or I (b)
2 Rate for Comprehensive Annual Maintenance Contract as per terms & conditions mentioned in the Bidding Document and as per format attached as Annexure - II
Note: If the above-tender details are not mentioned and required documents are not attached at appropriate places, the offer of the bidder(s) shall be summarily rejected. Hence, bidder(s) are advised to go through the bidding document carefully and tender be prepared with all the required documents to avoid rejection of offer.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 25/2026-2027/Bio Medical Equipt /IGIMS/Store
ELIGIBILITY CRITERIA Mentioned Page no.
1 Manufacturers or their authorized dealers/Indian subsidiaries/direct importers having a place of business in any of the States of India are eligible to participate in this tender.
2 The bidder and manufacturer of the equipment offered should be in the business of the supply and installation of same / similar equipment for the last five calendar years.
3 (a) The manufacturer should have completed at least 05( Five ) nos. installations of the quoted items in Govt. /Pvt. Institutions /Hospitals in India. The installations mentioned by the manufacturer in their offer must be functional and performance certificate for the same issued by the user concerned also be attached with the offer.
(b) The bids quoted as the authorized representative of the manufacturer meeting the above criteria 02 (a) should have also supplied and installed at least 03( Three) nos. installations of the quoted items in Govt. /Pvt. Institutions/ Hospitals in India in last five years from the last date of submission of tender. The installations mentioned by the authorized representative in their offer must be functional and performance certificate for the same issued by the user concerned also be attached with the offer.
4 The Bidder should be public undertaking /Autonomous Body /Public Ltd./Pvt. Ltd. Company or proprietary firm /Partnership Firm and should be in medical equipment business since last five years in India. The Bidders having manufacturing facility in their name in India for the majority of the items offered by them shall be given preference.
5 The Bidder (manufacturer or their authorized agent) should have had average annual financial turnover of Rs. 50 Lakh during the last three years ending s 31st March 2024.
6 Bidders who have the capability to attend repairs of these equipment within the time mentioned in this bidding document and who are willing to provide stand by equipment or replace the faulty equipment if the repair/down time extends beyond 72 hours from the time of reporting of the fault within the next 48 hours (total down time should not exceed 5 days in one instance). The bidders who have the capability to ensure the uptime mentioned in this document (Documentary proof shall be submitted on the after sales facilities and expertise of the bidder.)
7 Bidders are not offering the equipment of a firm /company that has
been blacklisted by Indira Gandhi Institute of Medical Sciences – Patna or blacklisted/debarred by any other State / Central Government's organization.
Note: Notwithstanding anything stated above, the Institute reserves the right to assess the Bidder’s capability and capacity to perform the contract satisfactorily before deciding on award of contract, should circumstances warrant such an assessment in the overall interest of the purchaser.
The Institute reserves the right to ask for a free demonstration of the quoted equipment at a pre determined place acceptable to the purchaser of technical acceptability as per the tender specification, before the opening of the price tender.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 25/2026-2027/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 1180
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- D (1)
SI. NO. Specification of Fully Automated Computerized Archival system for Histopathology and Cytology slides and blocks
Scope of Supply
The bidder shall supply, install, commission and provide comprehensive training for an Automated Pathology Specimen Archiving and Retrieval System for secure, high-density storage and automated management of pathology paraffin blocks and glass slides.
The system shall provide an integrated solution for :-
Automated specimen storage
Randomized/high-density storage
Automated specimen retrieval
Digital inventory management
Specimen location tracking
Borrowing and return management
Complete audit trail and traceability
Batch specimen identification/scanning
Environmental monitoring
User authentication and access control
LIS/LIMS integration
Reporting and analytics
The solution shall be modular and scalable to accommodate future expansion.
2. Automated Storage System
Sr. No. Technical Requirement Minimum Requirement
1 Storage methodology Automated randomized/dynamic storage rather than fixed-position manual storage
2 Storage of specimens Shall accommodate both pathology paraffin blocks and glass slides
3 Block capacity Minimum 100,000 blocks per cabinet/module
4 Slide capacity Minimum 140,000 slides per cabinet/module
5 Drawer/tray capacity Minimum approximately 500 pathology blocks per storage drawer/tray
6 Slide drawer/tray capacity Minimum approximately 700 glass slides per storage drawer/tray
7 Space utilization System shall optimize available storage volume through dynamic/randomized allocation
8 Location assignment Automatic assignment of storage location by the system
9 Location identification Each stored specimen shall have a digitally recorded unique location
10 Expansion Modular architecture allowing additional storage modules/cabinets to be added subsequently
11 Inventory Real-time inventory and available-capacity status shall be displayed electronically
The proposed architecture should avoid dependence on manually assigned permanent shelf positions and should automatically identify an available optimum storage location. The source system specifically describes randomized storage and automatic location assignment.
3. Automated Retrieval
The system shall provide automated retrieval of stored specimens.
Minimum requirements: -
1. User shall be able to search for a specimen using: -
Accession number/specimen ID
Barcode/unique identification
Patient-related reference number, where permitted
Other configurable specimen identifiers.
2. Upon selection of a specimen, the system shall automatically identify its stored location.
3. The storage mechanism shall automatically bring/guide the required specimen to the designated retrieval/access point.
4. The system shall provide visual and/or electronic guidance to the operator during retrieval.
5. The system shall record the retrieval transaction automatically.
6. The system shall minimize the requirement for manual searching of shelves, racks or drawers.
7. The system shall provide confirmation of successful retrieval.
8.Search-based one-click retrieval, automated positioning and indicator-light guidance.
4. Automated Batch Identification / Scanning
The solution shall support automated or semi-automated batch identification of pathology blocks and slides.
Minimum requirements :-
Batch scanning of multiple specimens.
High-speed identification of specimens.
Accurate capture of specimen/barcode information.
Support for mixed specimen scanning where technically applicable.
Automatic association of scanned specimen information with the digital archive.
Elimination/minimization of repetitive manual data entry.
Automatic creation/update of storage records.
Ability to associate specimen identification with its assigned storage location.
Workflow describes batch scanning, mixed scanning and automated capture of specimen information as part of the overall workflow.
5. Digital Specimen Traceability
The system shall provide complete end-to-end traceability of pathology specimens.
The software shall maintain, at minimum:
Specimen identification
Date/time of entry
Storage location
Date/time of storage
Retrieval history
User/operator details
Borrowing details
Current specimen status
Movement history
Transaction history
The system shall allow authorized users to determine:
Who accessed the specimen, when it was accessed, where it is currently located, and whether it has been returned.
The system shall maintain an immutable or controlled audit trail of specimen movements and transactions.
This reflects the source system's stated principle of recording every specimen, movement, user and record.
6. Smart Borrowing & Return Management
The system shall have an integrated electronic specimen borrowing and return management module.
It shall provide:
1. User authentication before specimen issue.
2. Digital recording of specimen borrowing.
3. Recording of :
Case/reference number
4. Return registration.
5. Identification of overdue/non-returned specimens.
6. Return reminders/alerts.
7. Complete borrowing and return history.
8. Ability to identify the current custodian/user of a specimen.
9. Audit trail of every transaction.
The source material specifically identifies digital borrowing records, return management and user authentication.
7. Handheld / Mobile Terminal
The system shall provide a suitable handheld/mobile operator terminal or equivalent mobile interface for archive operations.
The terminal shall support, as a minimum :-
Specimen scanning
Drawer/rack/location scanning
Specimen search
Guided specimen location
Retrieval confirmation
User authentication
Transaction recording
The mobile workflow shall allow operators to perform archive transactions without being permanently stationed at the central workstation. It identifies scanning, searching, locating, borrowing and returning as handheld functions.
8. Software & Digital Archive Management
The system shall include dedicated archive management software.
Software shall provide :-
A. Smart Search
Search specimens using multiple configurable identifiers.
B. Real-Time Location
Display current physical/digital location and status of specimens.
C. Digital Inventory
Total stored specimens
Available capacity
Occupied capacity
Storage utilization
Cabinet/module status
Specimen status
D. Transaction Management
Maintain complete records of storage, retrieval, borrowing and return.
Generate configurable reports relating to :-
Specimen movement
Borrowing/return
Storage utilization
Pending returns
Operational activity.
It should have smart search, real-time location tracking, digital inventory, LIS integration and data analytics/reporting.
9. LIS/LIMS Integration
The system shall support integration with the hospital/laboratory LIS/LIMS or equivalent laboratory information system.
Integration shall support, as applicable :-
Data exchange between LIS/LIMS and archive system
One-time data entry
Batch data import
Real-time data synchronization
Specimen identification exchange
Retrieval/status information exchange
Archive location information
Borrow/return status.
10. User Authentication & Access Control
The system shall provide controlled access to authorized users.
Minimum acceptable authentication methods shall include one or more of:
Username/password
Biometric authentication
Facial authentication
Other equivalent secure authentication mechanism.
The system shall support role-based access control, with configurable privileges for :-
Laboratory staff
Archive operator
Auditor/management.
All user activities shall be logged.
The system should be accessible through password, fingerprint and facial authentication as available mechanisms.
11. Environmental Monitoring
The storage system shall incorporate continuous environmental monitoring.
Minimum requirements:
Real-time temperature monitoring
Real-time relative humidity monitoring
Display of current environmental conditions
Configurable alert thresholds
Alarm/notification for abnormal conditions
Historical environmental records/logging.
Where applicable, the system shall provide environmental conditioning or corrective control to minimize moisture-related damage to archived specimens.
The temperature/humidity monitoring and one-touch environmental conditioning as system features.
12. Safety Features
The system shall incorporate appropriate safety mechanisms for personnel, equipment and specimens.
Operator Safety
Personnel/presence detection
Obstruction detection
Anti-drop protection
Emergency stop mechanism
Safe access to specimen retrieval area.
Equipment Safety
Overload protection
Anti-tip/tilt protection
Mechanical/electrical safety protections
Appropriate fire protection provisions.
Specimen Safety
Controlled access
Environmental monitoring
Protection against accidental dropping/damage
Secure storage against unauthorized access.
The system should have personnel presence detection, obstruction detection, anti-drop, overload, tip-over and fire protection.
13. Control Interface
The system shall provide a user-friendly control interface through touchscreen and/or workstation.
The interface shall permit :
Inventory management
User management
Alarm/status monitoring
Configuration and administration.
Voice-assisted or equivalent hands-free operational control may be provided as an additional capability.
14. Specimen Storage Integrity
The system shall be designed to ensure :-
Secure physical storage
Controlled access
Prevention of accidental specimen displacement
Reliable specimen-location association
Prevention of duplicate location assignment
Identification of occupied/available storage locations
Recovery of specimen location after system restart/power restoration.
15. Power Failure & System Recovery
The bidder shall specify :-
UPS/power backup requirements
Safe shutdown mechanism
Data protection during power interruption
Automatic recovery after restoration of power
Retention of specimen-location database
Manual emergency access/retrieval procedure.
The system shall not lose stored specimen location or transaction records due to normal power interruption.
16. Data Security & Audit
The system shall provide: -
User authentication
Role-based access
Controlled modification/deletion rights
Regular data backup
Database recovery mechanism
Secure data storage
Export of reports/data by authorized users.
All specimen movement and user activity shall be traceable.
17. Modular & Scalable Architecture
The system shall be modular and scalable.
18. Physical Configuration
The bidder shall provide complete details of :
Overall dimensions
Floor space requirement
Power consumption
Electrical requirements
Operating environment
Heat generation
Access/maintenance clearance
Loading/unloading arrangements.
The equipment shall be suitable for installation in a hospital/laboratory environment.
19. Installation & Commissioning
The successful bidder shall be responsible for :
Site assessment
System configuration
Software installation
LIS/LIMS integration
Performance demonstration
No additional installation infrastructure cost shall be payable unless specifically mentioned in the BOQ.
The bidder shall provide comprehensive training to :-
Laboratory personnel
Archive operators
System administrators.
Training shall cover :-
Specimen registration
Borrowing/return
User management
Troubleshooting
Preventive maintenance.
21. Demonstration / Proof of Compliance
The purchaser shall have the right to conduct a technical demonstration prior to final technical acceptance.
The bidder shall demonstrate, using the offered system :-
1. Batch specimen identification.
2. Randomized storage.
3. Automatic location assignment.
4. Digital search.
5. Automated retrieval.
6. Location guidance.
9. User authentication.
10. Complete audit trail.
11. Inventory monitoring.
12. Temperature/humidity monitoring.
13. LIS/LIMS integration or interface capability.
14. Report generation.
A bidder claiming compliance only through brochure/documentation shall not be considered sufficient where the functionality can reasonably be demonstrated.
22. Minimum Technical Compliance Matrix
> “Automated high-speed batch identification and accurate capture of specimen/barcode information, with capability to process multiple specimens in a batch.”
The system shall automatically assign and digitally record the physical storage coordinates/ location of every archived specimen and provide guided retrieval.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 25/2026-2027/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 1180
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- D (2)
SI. NO. Specification of Gas Chromatograph with Headspace Sampling System
1. Gas Chromatograph:
Supply, installation, commissioning, demonstration and training for one complete bench-top gas chromatographic analytical system suitable for routine QA/QC and research applications, integrated/configurable for headspace sampling.
System shall include the GC main unit, chromatographic oven, injection system, detectors as specified below, electronic gas/pneumatic control, control/display system, chromatography/data acquisition software, computer interface and the complete headspace sampling unit.
All standard interconnecting items, fittings, cables, tubing, communication interfaces, software licences, manuals and accessories required for safe installation, commissioning and routine operation shall be supplied.
Where any accessory is necessary for the quoted configuration to perform the specified application but is not separately listed, the bidder shall include it in the basic offer without additional cost.
2. Gas Chromatograph – Minimum Generic Technical Requirements
Parameter Minimum / required tender specification Instrument type Laboratory bench-top gas chromatograph suitable for capillary and packed-column applications. Column oven Temperature programmable oven with adequate capacity for capillary and packed columns; temperature range shall extend from approximately ambient/near-ambient to at least 400 °C; programmable temperature ramps and method storage shall be provided. Oven programming At least 8 programmable temperature ramps/steps with method storage; automatic/controlled cooling and stable temperature control shall be provided. Heated zones Independent temperature control for injector/detector and other required heated zones; system shall support stable operation of the offered detector/injector configuration. Temperature control Settable in fine increments (approximately 1 °C or better) over the applicable operating range. Injection system System shall support split and splitless capillary injection and packed-column injection. Single or multiple injector configuration shall be offered according to the detector/column configuration. Injector temperature Temperature control shall extend to at least 400 °C; higher range may be offered. Carrier-gas control Electronic programmable pressure/flow control for carrier gas, with selectable constant-flow and/or constant-pressure operation for capillary injection. Carrier gases System shall support commonly used carrier gases such as nitrogen, helium, hydrogen and argon, as applicable to the offered configuration. Gas safety Interlock/safety provision shall prevent or reduce heating operation in case of carrier-gas depletion or unsafe gas-flow condition. Split control Wide split-ratio control suitable for trace and routine GC applications; high split ratios shall be supported. Detectors – basic configuration At minimum, the quoted system shall include one flame ionization detector (FID) and one thermal conductivity detector (TCD), unless the procuring entity specifies another detector combination in the Schedule of Requirements. FID High-sensitivity FID with automatic ignition/flame monitoring and temperature control up to at least 400 °C. Vendor shall state detection performance and dynamic range for the offered detector. TCD TCD with stable filament operation, temperature control and filament-protection facility. Vendor shall state sensitivity/detection performance for the offered detector. Provision for selective detector System shall have provision to add/configure selective detectors such as nitrogen-phosphorus detector and/or electron-capture detector, without replacement of the complete GC system. NPD/ECD (if included in quoted configuration) Where offered, detector shall have appropriate temperature control and safety provisions; bidder shall state detection performance and applicable source/safety requirements. Display / local control Front-panel display and keypad/local controls or equivalent interface for viewing status and setting essential operating parameters. External event control Provision for programmable external event/control outputs and logic inputs/outputs for chromatographic accessories shall be available. PC communication Full PC control of GC parameters, run status and data acquisition through standard communication interface(s). Power supply Suitable for Indian laboratory electrical supply, nominal 230 V AC, 50 Hz, with required protection and power cabling. Construction Robust laboratory construction, compact bench-top form factor and suitable for continuous laboratory use. Software Licensed chromatography/data-acquisition software compatible with the supplied GC. Software shall permit method creation, instrument control, chromatogram acquisition, processing, integration, report generation and data storage/export. Software access Software licence(s) required for the supplied system shall be included. Any required drivers, communication modules and installation media/download access shall be included.
1. Headspace Sampling System – Minimum Generic Technical Requirements
Parameter Minimum / required tender specification Type Automated/static headspace sampler suitable for coupling with the supplied gas chromatograph for analysis of volatile/semi-volatile components and residual solvents. Sample capacity Capacity for at least 20 samples/vials in a continuous sequence. Vial size Compatible with approximately 20 mL headspace vials; bidder may offer equivalent standard vial formats with corresponding consumables. Mode Static headspace sampling. Sample loop Approximately 1 mL sample loop or equivalent capacity suitable for GC headspace injection. Valve system Automated multi-port, air-actuated or equivalent switching valve suitable for reliable headspace sampling and GC injection. Sample path Inert/chemically compatible tubing, with a sample path equivalent to stainless-steel tubing suitable for headspace applications. Vial temperature Programmable/controllable from ambient to at least 200 °C; capability up to approximately 250 °C shall be acceptable/preferred where supported by the offered system. Sample line temperature Programmable/controllable independently or suitably linked with vial temperature, extending to at least 200 °C and preferably approximately 250 °C. Valve/loop temperature Temperature control shall be provided and coordinated with the vial/sample-path temperature to minimise condensation and carryover. Sequence programming User-selectable vial sequence, including single vial, multiple vials and programmable sequence up to the full sample capacity. Display Local display showing operating mode, temperature/status and sequence information; backlit LCD or equivalent is acceptable. Keypad/control Local keypad or equivalent control interface for programming and status monitoring. Operating environment Suitable for normal laboratory operation; bidder shall state permissible ambient operating temperature and humidity. GC interface Complete hardware/interface required for reliable communication and triggering between the headspace sampler and supplied GC shall be included.
6. Accessories and Items to be Included in the Supply
Item Requirement Quantity / inclusion Headspace sampler Complete automated/static headspace sampling unit matching the offered GC configuration. 2 complete set Headspace vial set Standard headspace vials of the specified capacity, compatible with the supplied sampler. Initial working set Vial closures Compatible septa/caps/closures and required sealing accessories for the supplied vials. Initial working set Vial handling accessories Vial rack/holder/tray and other standard handling accessories required for full sample capacity. 2 set Sample loop Factory-fitted or supplied sample loop of the specified capacity. 1 installed + spare where standard Valve and tubing Complete valve assembly and chemically compatible sample-path tubing/fittings required for operation. 2 complete set GC injector accessories All liners/inserts, ferrules, nuts, septa and standard fittings necessary for the quoted injector configuration. 2 initial set Column connection accessories Standard nuts, ferrules, adapters and fittings needed for connection of supplied/compatible capillary and packed columns. 2 complete set Detector accessories All standard detector installation parts, jets/filaments or equivalent replaceable operating parts supplied as standard by the manufacturer for the quoted detector configuration. 2 complete set Gas control accessories Required pressure/flow control modules, regulators/interfaces and fittings integral to the quoted instrument configuration. 2 complete set Gas safety accessories Required interlocks, pressure switches and safety fittings integral to the offered system. 2 complete set Gas purification Gas purification system, traps/filters and associated fittings, where required for the quoted detector/GC configuration. 2 complete set Gas extraction/venting accessory Suitable gas extraction/venting arrangement for the headspace/GC configuration where required for safe operation. 2 complete set Gas sampling valve Multi-port gas sampling valve suitable for gas sampling/column switching/backflush applications, where included in the requirement; the tenderer shall quote compatible valve options separately. 2 set, if specified Methaniser Methaniser compatible with the supplied GC/TCD configuration, if required for the intended analytical application; quote as a separate line item. 2 set, if specified Additional pressure controller External programmable pressure controller with programmable ramps, if required for advanced methods; quote separately. 2 set, if specified Sniffer port Sniffer/inspection port compatible with the GC system, if required; quote separately. 2 set, if specified Autosampler Automatic liquid sampler compatible with the supplied GC, if required; quote separately with all control/interface accessories. 1 set, if specified Computer Desktop computer/laptop of current commercially available configuration adequate for GC control/data acquisition, with required operating system and ports/interfaces. 1 set UPS Online/line-interactive UPS of adequate capacity for the supplied GC, headspace sampler and computer, with suitable backup duration as specified by purchaser. 1 set Printer Printer compatible with the supplied data system, if required by purchaser. 1 Cables & interfaces All power, signal, communication and trigger cables required for complete integration of GC, headspace sampler and PC. 2 complete set Software Full licensed instrument-control/data-processing software and all required drivers/interfaces. 1 licence/set Documentation User manuals, installation manuals, service/maintenance manuals, software manuals and calibration/verification documents. 1 complete set Consumable starter kit Reasonable initial quantity of standard consumables necessary for commissioning and performance demonstration, as listed by bidder in the offer. 2 starter set
1. Installation, Commissioning and Acceptance
Installation shall be carried out at the purchaser's site by trained/authorised technical personnel.
Supplier shall provide all installation accessories, interconnections and initial setup required to make the complete system operational.
Supplier shall demonstrate GC temperature control, detector operation, gas-flow/pressure control, software control, headspace vial sequencing and successful transfer/injection of a headspace sample into the GC.
Acceptance shall be based on satisfactory installation, commissioning, demonstration of the offered specifications and submission of relevant calibration/quality documents, wherever applicable.
Any site requirements such as gases, ventilation/exhaust, electrical points and bench space shall be clearly stated by the bidder before supply. The bidder shall not assume that proprietary site infrastructure is available unless explicitly stated in the tender.
On-site application/operation training shall be provided to designated laboratory personnel.
Training shall cover instrument operation, method creation, headspace sequence programming, chromatographic data acquisition, processing, report generation, routine maintenance and basic troubleshooting.
Supplier shall provide training material/operating instructions in electronic and/or printed form.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 25/2026-2027/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 1180
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- D (3)
SI. NO. Specification of Triple Quadrupole Liquid Chromatography-Mass Spectrometry System
Bench top Triple Quadrupole Mass Spectrometry coupled with Liquid Chromatography for high sensitivity trace level quantitative analysis with following specifications.
Sl No. Description Product Specification 1 Mass Spectrometer API Interface The instrument must have a proven atmosphere to vacuum interface. The interface must be capable to handle large batches of complex samples in blood plasma/serum, body fluids extract over a long period. The API source must incorporate a safety interlock switch to shut off voltages when source housing is opened or removed from the system. Source Dedicated separated ESI and APCI probe should be quoted for optimum sensitivity, ESI and APCI should handle flow rate of 2ml/min or better without splitting. The desolvation temperature should be 550 degrees Celsius or better for both ESI and APCI mode. System should have APPI compatibility. The ion beam guide, with its suitable technology to block neutral should stops neutrals and high-velocity clusters, keeping the ion path cleaner, reducing noise, increasing sensitivity and robustness. Mass range: The MS operational mass range should be from 10 – 2000 m/z or better MS/MS sensitivity (SRM/MRM) Electrospray Positive (ESI) sensitivity: Minimum signal-to-noise ratio should be 5,00,000:1 or better with 1pg/ul reserpine solution or equivalent for the transition m/z 609.3 to the fragment ion at m/z 195.1. Electrospray Negative (ESI) sensitivity: Minimum signal-to-noise ratio should be 5,00,000:1 or better with 1pg/ul chloramphenicol solution or equivalent for the transition m/z 321.0 to the fragment ion at m/z 152.0. Atmospheric pressure chemical ionization (APCI): Total injection of 1pg/ul reserpine solution will produce a minimum signal-to-noise ratio of 50,000:1 or better for the transition m/z 609.3 to the fragment ion at m/z 195.1 or equivalent. Instrument Detection Limit IDL (Instrument Detection Limit) for <5fg Reserpine must be ≤ 0.5 fg. Documentary evidence must be submitted. IDL for <5fg of Chloramphenicol must be ≤ 1.5 fg. Should be part of the instrument specification sheet. Collision Cell The collision should have suitable design to reduce the chemical background noise and increase effective S/N. Collision Cell should be capable to have zero cross talk that helps for excellent sensitivity and speed. Dwell Time The CID should be able to work with low dwell time of less than 1 milliseconds or better Resolution Resolution should be up to 0.4Da FWMH for better selectivity across the entire mass range. Scan Speed 15,000 amu/sec or better SRM / MRM transitions System should be capable to perform up to 30,000 SRMs definable and up to 800 SRMs/sec or better. Scheduled SRMs should have 1msec dwell time / 1msec inter channel delay without loss of sensitivity Polarity Switching The MS system should have ion polarity switching to less than 10 milliseconds or less. Dynamic Range The MS system should have 6 order of dynamic linear range or better. Divert Valve The divert valve must be under fully automated data system control. The divert valve must enable the user to switch the solvent front, gradient end point and any other portion of the HPLC run to waste. Allow user to define the default state of the valve and change state in time segments. Scan Functions Must acquire and display Full Scan mass spectra from Q1 and Q3 Must acquire and display Selected Ion Monitoring (SIM) scan data. Must acquire and display Full Scan Product ion spectra. Must acquire and display Full Scan Precursor ion spectra. Must acquire and display Full Scan Neutral loss ion spectra. Must acquire and display Selected Reaction Monitoring (SRM/MRM) data. MS/MS data along with MRM to confirm the compound of interest. Enhanced Product Ion Scan or Quantitation enhanced data dependent scanning or equivalent 2 Quaternary/Binary Gradient UHPLC with Auto sampler, Column Oven with suitable columns should be offered as Front-end to the Mass Spectrometer Pump Quaternary/Binary Gradient operations. The flow rate range should be able to set around 1 µl to 2 ml/min or better. Flow rate accuracy should be +/- 0.1% of set value. Flow rate precision should be 0.05% RSD or better. Maximum Pressure tolerance should be 15,000 psi or better. Solvent degassing: Built in 4 channel or better. Gradient precision 0.15% RSD or better. Wetted Part should be MP35N, titanium, ceramics, sapphire, PEEK, UHMW PE, fluoropolymers or equivalent. Auto-Sampler Injector with Sample Cooler Auto sampler should be available with a capacity of 200 vials of 1.5 ml or more. Auto sampler should be capable of accommodating 96 well plate with injection volume range from 0.1– 25 ul with 0.01 ul increment. Temperature setting range should be from 4 to 40°C or better. Injection linearity: r >0.99999 (caffeine in water or equivalent). The carryover must be <0.002% with caffeine or better. Injection volume accuracy should be ±0.5% or better. Injection volume precision should be less than 0.25% RSD or better. Autosampler should be able to handle maximum pressure limit of 15,000 psi or higher without any additional setup or modifications. pH range should be covered from 2-12. Sample loop 100uL and strong solvent loop must be supplied Column Oven The column compartment must provide Dual Thermostatting Modes; Still air for highest efficiency at UHPLC conditions and forced air for easiest method transfer. The temperature range should be ambient +5 °C to 80 °C or more in 0.1 °C increments. Temperature accuracy should be ±0.5 °C or better. Should accommodate 2nos. of column or more with individual programming. Active pre-heating and post cooler must be available for all column installed Diode Array Detector: The detector must typically provide a linear range up to 2 AU or better. The wavelength range of the detector must range from 190 to 800 nm or better. The drift of the detector must be below 1 mAU/h or better at 254 nm. Detector Noise must be <± 6μAU or better at 254 nm. No of Photodiodes must be 1024 for better. The detector must provide a data collection rate of up to 120 Hz or better with spectra acquisition. The detector must be able to record 8 channels plus 3D field simultaneously. Standard analytical flow cell should be of 10mm path length and >10μL flow cell volume. The detector must have an internal wavelength calibration using the D-alpha line of the deuterium lamp. Wavelength validation must be validated by a holmium oxide filter. The detector must provide a software-supported predictive performance function for scheduling maintenance procedures. The Detector must have built in safety features like Leak detection and safe leak handling, excess pressure monitoring. Column Should provide with the system. RP C18, 100mm x 2.1 mm, 2.6 µm- Quantity 2 HILIC C18, 100mm x 2.1 mm, 2.6 µm- Quantity-2 C18 column, for vitamin D2, D3, Vit A, Vit C, Vit E, Vit K: 75mmx 3 mm × 3 u column- 1number C18 100A Diameter: 50 mm × 4.6 mm, 2.6 u for immunosuppressants Amino acid analysis column, 150mm × 3mm, 3um- 1 numbers Phenyl column: 150 mm × 4.6 mm, 5 u for Meta nephrine and Nor Metanephrine- 1 number Workstation Software Single software platform must be provided for a seamless control of all the modules of LC and MS. Auto Start-up and shutdown of the MS should be possible using a single key operation. Method file should be capable to save all analysis parameters, data Processing parameters and report format. The instrument should have a single point of control for both the MS detector and the HPLC from single vendor. Software for processing targeted metabolomics and peptide quantification dataset shall be quoted PC & Printer Original and Licensed software, computers with all interfacing hardware and software for instrument control, Data Acquisition and Data Processing must be supplied compatible to the LC-MS System must be quoted. Computers: 2 in numbers [One with the LC & MS unit and another for installing data processing software] with the following or equivalent or higher specification. Printer- One Mono LaserJet Printer Accessories 1. Suitable imported Gas generator with built-in compressor for the LC MS should be provided. 2. Gas: High-purity (99% pure, UHP grade Argon-Qty 1 each. With dual stage Pressure regulator – Qty 1 No. for each gas 3. Branded 15 KVA true online UPS 30 minutes backup. 4. Gas purification panel with traps and filter 5. Suitable external pump to create vacuum to start the turbo pump of MS 6. Solvents of MS grade such as ACN (10 ltrs), Water (20 ltrs), Methanol (16 ltrs) along with 500 mL of formic acid [10 X 50 ml] should be provided. 7. All required standards of mass calibration (positive and negative) and tuning, to make the instrument functional should be provided. Micro-syringes (2 Nos) for injection of samples should be offered. 8. LC-MS/MS installation kit should be supplied as standard along with regent & standards for NBS for at least 2000 samples. (MINIMUM 2 SET OF NBS KIT have to be provided.) 9. Standards of vitamin D2, D3, Vit A, Vit C, Vit E, Vit K, immunosuppressants, Meta nephrine and Nor Metanephrine1, all amino acids for LCMS should be provided at the time of installation of equipment. 10. Automated DBS Puncture to be quoted. 11. Sonicator to be provided 12. 24 position manifolds with vacuum pump and SPE cartridges.
Note: - System software configuration should be able to work for Stand-alone, all in one PC (with core i5, desktop 27-32-inch desktop, genuine windows, etc.,). Suitable 10 KVA Online UPS with at least 30 min backup connected, or direct connection to network Cloud via LAN or Wi‑Fi. and start-up reagents should be provided to run atleast 2000 reactions.
20. All the essential civil and electrical works during installation in laboratory should be provided by the vendor.
21. Working table and cover for equipment should be provided by the vendor at the time of installation.
22. Technical support for instrument operation, method development and data analysis for six months shall be provided. The system shall support pathological/cancer biomarker analysis, newborn screening and toxicological testing using LC-MS/MS-MRM/SRM. Complete workflows shall be demonstrated at installation. Essential consumables, standards (all available vitamin, amino acid etc.,) and accessories for 2,000 samples/tests shall be provided.
23. After successful installation and commissioning, on-site operational training for the deputed personnel to be provided for 6 months at no additional cost.
24. All essential civil, electrical, installation-related works, and necessary accessories required for the successful installation, commissioning, and operation of the system in the laboratory shall be provided by the vendor at no additional cost to the purchaser.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 25/2026-2027/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 1180
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- D (4)
SI. NO. Specification of Gel Imaging System
1. The system should be a compact, standalone gel Imaging/documentation system suitable for imaging nucleic acid and protein gels with fluorescent and colorimetric stains.
2. The system should support colorimetric, fluorescence, and GFP colony-counting imaging modes.
3. The system should incorporate a scientific CMOS (sCMOS) camera with at least 5-megapixel resolution for high-quality gel image acquisition.
4. The system should provide a field of view of at least 14 × 21 cm (5.5 × 8.3 in.) and should accommodate gels up to approximately 20 × 13 cm, including multiple mini/midi gels.
5. The system should have integrated UV, blue, and white LED transillumination to support a broad range of nucleic acid and protein gel stains.
6. Illumination wavelengths should include approximately:
o UV: 300–310 nm
o Blue: 460–470 nm
o White: 400–800 nm
7. The system should include an approximately 590 nm emission filter for fluorescence imaging.
8. The system should provide automatic tray recognition, enabling the instrument to identify the installed sample tray and activate the appropriate imaging mode automatically.
9. The system should offer one-touch image capture with automatic exposure determination for rapid and reproducible image acquisition. Manual adjustment of exposure time, field of view, and illumination intensity should also be available.
10. The system should have an integrated 12.1-inch LCD touchscreen display with approximately 1024 × 768-pixel resolution, allowing standalone operation without requiring an external computer for routine image acquisition.
11. The system should have an integrated computer with at least:
· 500 GB solid-state drive
· Approximately 1 TB storage
· Monitor: - ≥ 27’
12. The system should provide multiple data-transfer and connectivity options, including USB 2.0/3.0, Ethernet, and Wi-Fi capability.
13. The system should support common image formats including TIFF, JPG/JPEG, PNG, as well as a proprietary format suitable for subsequent image analysis.
14. The system should include compatible image-analysis software for advanced image analysis, annotation, data reporting, and image processing. The analysis software should support PC, Mac, and cloud-based workflows.
15. The system should incorporate a UV safety shield with automatic safety detection/shutoff to help protect the operator during UV-based gel excision procedures.
16. The complete system should include UV, blue, and white imaging trays, tray rack, UV safety shield, and image-analysis software.
17. The system should have a compact footprint of approximately 38 × 45 × 41 cm and weight of approximately 22 kg, suitable for routine benchtop laboratory use.
18. The instrument should operate on 200/240 V, 50/60 Hz power supply for the offered configuration.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 25/2026-2027/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 1180
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- D (5)
SI. NO. Specification of Microwave Multifunctional Tissue Processor
Stable Ergonomical compact design.
Metal housing with stainless steel lining.
Bench unit with programmable microprocessor control and at least 10” LCD display and touch screen/keyboard in external operating console.
Silent electro-mechanical motors for agitation and transport of slide carrier.
Transportation arm on X, Y and Z axes for positioning the slide carriers.
Divided transparent methacrylate/acrylic cover over the entire working area to protect the user against hazardous vapours.
Integrated fume hood with active carbon filter and preset timer with count-down function to monitor the filter change interval.
Alteast 30 reagent stations each with up to 300-400 ml capacity & 4 loading & 4 unloading.
4 Rinsing station with through flow that can be controlled and simple water pressure control.
Drying station with temperature control upto +650C.
Should run H & E and Papanicolaou or other special terms simultaneously with advanced optimization software.
Should be able to allocate a specific protocol to each load station for quick and error free slide loading.
Slide capacity of carrier up to 30 slides per carrier in vertical position.
Slide Throughput : 200-300 slides/hour.
It should be able to run 12 simultaneously program with upto 30 slides each slide carrier capacity
Electronic components separated from humid working areas.
Agitation should be continuous
Microprocessor control of immersion time (0 sec.-99 min. 59 sec.) for each station.
Permanent memory capacity for up to 40 different programs.
Simple to operate external control panel with touch screen at least 10” LCD display.
Indication of date, time, remaining time in process step, step number and reagent description.
Optical and acoustic alarm during power failure and program end.
Should have drip tray to reduce reagent carry over contamination
Manual basket removal during power failure.
Printer/USB connection
On line UPS of standard make & appropriate calibration should be supplied. UPS & UPS batteries should be covered under both warranty & CMC.
Equipment should be CE /FDA approved.
Equipment should be ISO 9001:2015 and ISO 13485:2016 certified
Battery backup upto 45 minutes
Equipment should be supplied with:
a. 30 reagent containers.
b. 4 Rinsing container
c. 4 loading and 4 unloading station
c. 1 Pressure resistant water inlet tube
d. 1 Draining hose
e. Connecting clamps
f. 10 Slide carrier for 30 glass slides
g. 1 Active charcoal filter
i. Replacement fuses
j. Instruction manual.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 25/2026-2027/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 1180
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- D (6)
SI. NO. Specification of Cold Plate (Cooling Plate)
Should be in 3-part modular system with separate fully programmable automatic on/Off control for each of them.
Paraffin Dispensing Unit
Capacity of Paraffin Tank: should be minimum 5 litres.
Capacity of Thermal Chambers for storage of moulds: min 1.8 liters
Temp. range of Paraffin tank: 50-700C
Temp. range of Thermal Chamber: 50-700C
Temp. range of Hot plates & forceps wells: 50-700C
Should have connection for electrically heated forceps
Should have provision of rapid heating of paraffin wax
Should have six heated wells for normal forceps, 3 on either side of the wax dispensing line.
Should have precisely metered and adjustable gravity feed paraffin dispenser to deliver the right amount of paraffin.
Should have both finger touch plate and foot switch for control of paraffin flow.
Should have large warm working surface on either side for min 10 cassettes on each side.
Should have dot matrix 7 segment display.
Should have a Magnifying lens adjustable in any position, large
Should have in-built paraffin trimmer
Cold spot & illumination for specimen orientation.
Unit should be CE/FDA approved
Capacity of freezing up to 100 blocks at a time.
Temp. range of cold plate: 0-120C, adjustable in steps of 10C.
Compressor to be extra quite to reduce noise fatigue.
Cold console can work independently without switch –on dispensing console
The system should work on 220-240V, 50 Hz. Should use CFC free gas and manufacturer must have ISO certification.
2 years comprehensive warranty and 3 years non-comprehensive warranty for equipment free of cost.
Should be supplied with 1000 nos. Plastic Embedding Rings for making paraffin Blocks and 100 nos. reusable Metallic Base moulds
Comprehensive training of lab staff and equipment support services till familiarity with equipment.
Certificate of calibration and inspection from manufacturer.
User/technical/maintenance manual
There should be a provision for demonstration before final approval of equipment.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 25/2026-2027/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 1180
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- D (7)
SI. NO. Specification of Storage Cabinet for Specimens
Block Cabinet (Capacity: 25000)
1. The cabinet should be made of CRCA steel after 7-Stage Phosphating Process with white powder coated paint finish for very high scratch resistance & long life.
2. The internal drawers should be also made of M.S. duly powder coated.
3. The cabinet should be made of 20-gauge sheet.
4. The cabinet should have drawer having 4 to 8 compartments with capacity of 136 blocks approximately.
5. Should have capacity of keeping 25000 blocks.
6. The cabinet should be provided with Door to protect from dust.
7. The cabinet should have handle & key lock.
8. The Dimensions of the cabinet should be 1440(W) x 480(D) x 1950(H) approx.
9. The weight of cabinet should be approx. 400 kg.
10. The instrument should be certified with following certifications, to be attached with Bid.
11. CE (European)
13. ISO 13485:2016 for Medical Devices
16. NSIC Regn. Certificate should also be provided with Bid.
Slide Cabinet (Capacity: 50000)
1. The cabinet should be made of CRCA steel after 7-Stage Phosphating Process with white powder coated paint finish for very high scratch resistance & long life.
2. The cabinet should be made of 20-gauge sheet.
3. The cabinet must be capable of keeping 75 × 25 mm Slides in vertical position one after the other.
4. Should have capacity of keeping 50000 slides.
5. The cabinet should have 480 × 75 mm Drawers and must takes slides in vertical position.
6. Should have 160 Drawers.
7. The cabinet should be provided with Door to protect from dust.
8. The cabinet should have handle & key lock.
9. The Dimensions of the cabinet should be 617(W) x 540(D) x 1350(H) approx.
10. The weight of cabinet should be approx. 166 kg.
11. The instrument should be certified with following certifications, to be attached with Bid.
o CE (European)
o ISO 13485:2016 for Medical Devices
12. NSIC Regn. Certificate should also be provided with Bid.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 25/2026-2027/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 1180
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- D (8)
SI. NO. Specification of Bone Cutter
1. The equipment should be independent floor standing with ‘C’ shape construction.
2. Body Frame should be CRCA Powder Coated after 7-Stage Phosphating Process for very high scratch resistance & long life.
3. Sheet metal should be fabricated on CNC machines for Fabrication accuracy, reliability & finish.
4. All welding should be TIG/MIG.
5. Cutting Table should be made of thick stainless steel sheet grade SS304 with heavy for firm, smooth, jerk free movement.
6. Size of Cutting Table should be 785 x 585 mm, ±10mm approx.
7. Total Table Travel should be about 1245 mm ±10mm,
8. Size of Extension Table should be about 455 × 760 mm ±10mm.
9. Motor Capacity: 1 H.P. Crompton Make.
10. The system should have strong blade that can cut thin bone slice.
11. Low vibration.
12. Following Certifications are required mandatorily with the Bid:
13. CE (European)
15. ISO 13485:2016 for Medical Devices
18. Should be supplied with blade, electrical cord and hospital-grade plug.
19. Suitable to work on 220V, Single phase, 50 Hz AC supply
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 25/2026-2027/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 1180
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- D (9)
SI. NO. Specification of Tissue Flotation Bath
1. For precise control of different samples at constant temperature.
2. Tissue Flotation Bath is ideal for tissue culture, enzyme reactions fermentations tissue section processing etc.
3. Micro Processor based Digital Temperature Controller.
4. Inner chamber is rectangular in construction & made of seamless (Die pressed) for easy cleaning.
5. The jet-black surface with scratch-proof coating provides better contrast to identify sections and an easy to clean gray surface.
6. Removable glass container.
7. The broad oversized rim of the water bath allows convenient storage for microscope slides.
8. Rounded inner corners allows it to be cleaned easily and efficiently.
9. Embedded heater element plate.
10. Should also have Slide Warmer on the top of machine.
11. Slide Warmer should be such that slide can be take out without disturbing the other.
12. Temperature for Slide Warmer & Tissue Floatation Bath can be controlled seperately.
13. It should have White LED light inside floatation bath so that tissue can be seen while floating.
14. Temperature selectable between ambient to 90°C.
15. Temperature is controlled by capillary type thermostat, from ambient to 900C with an accuracy of ±10C.
16. Overheating protection system.
17. LED illuminated black background with transparent glass dish allows specimen to be
18. LED display for programmed and tempecaitye display and visual indication in case of temperature exceeds above 45°C.
19. High grade insulation.
20. Membrane keyboard is resistive to water and paraffin contamination and is easily
21. The Tissue Flotation Bath is supplied complete with pilot light, cord and plug.
22. Dimensions: WxLxH (cm): 403 x 520 x 176
23. Voltage: 220V, 50 Hz, Single Phase, A.C. Supply
24. Should be CE/USFDA/WHO-GMP certified.
25. Equipment should have one year warranty
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 25/2026-2027/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 1180
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- D (10)
SI. NO. Specification of Slide Warming Table
. Compact, table top design with corrosion-resistant, outer housing
2. Adjustable temperatue range ambient to -800C
3. Up to a minimum of 40 slides capacity
4. Provision to attach at the side vetically
5. Heating temperatue : upto 800C
6. Digital temperature controller with +/- 10C accuracy
7. Large LED display for real time temperature readout
8. Accommodate upto 50 standard microscopy slides (75 mm x 25 mm) simultaneously
9. Should be able to pull out slides without disturb the other one
10. Power supply: 220-240V AC, 50/60 Hz
11. CE/ISO Certification
12. Equipment should have one year warranty
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 25/2026-2027/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 1180
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- D (11)
SI. NO. Specification of Electron Microscope
S/N Technical Parameters Descriptions Latest state-of-the art design, Electron Microscope (EM) with environmental mode and necessary accessories for imaging & analytical studies for pathological application example: Tissue etc. 1. Electron Source: Tungsten (W) filament. The source alignment should be automatic. 2. Resolution: • 2.5 nm at 30 kV (SE) or better in High Vacuum mode • 7.5 nm at 3 kV (SE) or better in High Vacuum mode • 3.4 nm at 30 kV or better in Low Vacuum mode 3. Operational Modes: • High Vacuum and Variable Pressure/Low Vacuum mode up-to 2500 Pa 4. Accelerating Voltage: 0.2 kV to 30 kV, with incremental step of 10 volts for the entire range. 5. Probe Current: Up to 3 µA or more – continuously variable 6. Magnification: 10x to 10,00,000x - continuously variable 7. Electron-Optics: The EM should be equipped with suitable Condenser and Objective lenses. The focus control of the objective lens should be automatic. EHT and Rotation compensation should be automatically adjustable. The system should have adjustable aperture from outside for both imaging and analysis purpose. 8. Vacuum System: The vacuum system should be capable of producing ultra clean high vacuum using appropriate turbo molecular pump backed by rotary pump to achieve required vacuum at reasonable time. Variable Pressure Range should be 10 Pa – 2500 Pa. 9. Stage Specification: 5-axes Fully Motorized Stage with movement facility with: o X = 90 mm or higher o Y = 90 mm or higher o Z = 50 mm or higher o Tilt = 10o to +90° o Rotation = 360° - continuous • Facility to accommodate multiple specimens should be provided. • Need to provide multiple sample holder up to 9 or more sample stubs to be hosted up. • The stage should accept samples up to 500 gm at full motion of all the 5 axes 10. Specimen Chamber Specification • Large Specimen Chamber with internal diameter / width 300 mm and height 200 mm or more. • Minimum number of spare ports in the chamber should be 8 or more for integrating accessories & detectors in future. • Sample size: 180 mm in diameter or better. • Sample height: 100 mm or better. 11. Detectors: • Secondary Electron Detector (ET-SED) for use in high vacuum mode. • High Definition Segmented Angular / Directional Back Scattered Electron Detector • Variable Pressure Secondary Electron Detector (VPSE) • IR-CCD camera for viewing inside the specimen chamber 12. Computer system & Image Processor: High-end Computer system with high capacity Hard disk (1TB or more) and CD/DVD writer drive, 27 inches Color monitor, Keyboard, mouse should be provided. The PC should be equipped with latest licensed windows operating system. The Image Processor should have image Frame store of resolution at least 32k x 24k pixels. 13. Software: Complete software for the EM and related accessories for data acquisition, analysis and interpretation should be included in the system configuration. 14. Accessories & Consumables for EM: • 2 rolls of carbon tape. • Specimen stub: 20 nos. • Tungsten Filaments: 20 nos. • Desiccator for reducing moisture in vent air: 1 no. (Dry Air venting is preferred) • Online UPS 10 kVA: 1 no. • Sputter Coater • Critical Point Dryer • Glutaraldehyde, osmium tetroxide, phosphate buffers, Graded ethanol for sample preparation 15. Peltier Cooling stage for investigating the hydrated sample • Temperature range between -50°C up to +50°C • Temperature accuracy: +/-1.5°C or 2%, whichever the greatest • Temperature display resolution: 0.1°C • Maximum Specimen size: 5mm height & 10mm diameter • Temperature stability: +/-0.2°C • Temperature display resolution: 0.1°C • Maximum cooling/heating rate: 12°C per minute • Microprocessor controlled • Keypad/display for temperature display and control • Vacuum feed-through flange with all connections • Supplied with 15x standard & 15x dished specimen stubs • RS-232 or USB interface to enable remote readout and control • CE & RoHS compliant 16. Upgradability (Advance feature) The system should be provided with EDS. 17. Installation, Commissioning & Training The installation, commissioning and demonstration of complete system should be carried out by the supplier at free of cost. After successful installation and commissioning, on-site operational training for the deputed personnel to be provided for 6 months at no additional cost. 18. Service Facility The supplier must have sufficient nos. of service engineers in India to provide prompt services at any point of times as & when needed. 19. Pre-Installation requirement Pre-installation details, such as, room, floor plan, size, electrical requirement, EM field & vibration levels etc. should be sent immediately after the placement of the order and the installation site should be surveyed physically to check its suitability by the vendor. A copy of the pre-installation requisites should be enclosed along with the technical bid. Necessary environmental requirements, i.e., temperature, humidity etc. during the operation (and unused hours) of EM & EDS should be specified clearly. Note: - All essential civil, electrical, installation-related works, and necessary accessories required for the successful installation, commissioning, and operation of the system in the laboratory shall be provided by the vendor at no additional cost to the purchaser. 20. STEM Detector STEM detector for brightfield and Darkfield imaging with STEM grid. 21. Warranty As per IGIMS tender norms.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 25/2026-2027/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 1180
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- D (12)
SI. NO. Specification of Tissue Microarrayer
1. Should have preferably Automated or Semiautomated Tissue Processor requiring minimal interaction from the user 2. Small batches of minimum 4 cassettes allowing flexibility of urgent processing of biopsy within one hour 3. Should be availability of processing of minimum 100 cassettes 4. Should be availability to perform rapid bone decalcification 5. Should perform rapid special stains for minimum 12 slides 6. Should have facility for antigen retrieval within two hours 7. Should have facility for faster fixation of minimum 100 cassettes 8. The gross specimen should be hardened through microwave heating-induced coagulation of the proteins, while the tissue is immersed in saline solution 9. Should have capacity to perform rapid processing system for electron microscopy: through a dedicated kit and preset programs for different kind of resins, and samples can be processed within 4 hours 10. Should have EM system allowing closed vessel processing from fixation through 100% resin, limiting to a minimum the operator’s exposure to toxic reagents. Microwave Rapid Tissue Processor Application: Continuous rapid tissue processing Power requirement: Single phase, 200 VAC +/- 10%, 50/60 Hz, 15A Weight: Less than 500kg Retorts: Load station- 1 station or more; Retorts- 4 or more; Unload station: 2 stations or more Capacity: Up to 40 cassettes, every 30 minutes or less Processing programs: Standard up to 2mm; 60 minutes or Extended up to 3mm; 120 minutes Temperature Ranges: Processing stations 1 and 2:51° C ± 1° C; Processing stations 3 and 4:65° C ± 2° C Certifications: FDA certified Regulatory status: IVD, FDA Tissue Microarrayer It can process multiples of 24 samples with the following features 1. The Tissue Microarrayer (TMA) should be software-controlled electronic laboratory device that is able to automate the creation of tissue microarrays (TMAs) and also the process of PCR sampling. 2. The creation of TMA blocks and the insertion of extracted tissue cores into PCR tubes should be controlled by using a graphical user interface. 3. TMA handling capacity: minimum 72 (60 donor, 12 recipient) 4. It should have automatic recipient block creation by drilling. 5. Automatic block height and tool size measurement for precise operation. 6. System should be capable for loading, imaging, drilling and punching simultaneously. 7. Multiple core diameter options should be available from 0.6, 1, 1.5 and 2 mm 8. Extraction of tissue samples in PCR tubes for molecular should be available. 9. The equipment should have dedicated software for TMA block design & creation: layout for recipient block, donor block data, Spot finding, and automated data binding should be done through software interface. 10. TMA data should be exported in various spread sheet formats like ODS, XLS, XLSX, CSV 11. Speed should be 250-280 cores to be transferred per hour 12. Max number of cores per TMA block should be 558 (0.6 mm), 286 (1 mm), 135 (1.5 mm), 84 (2 mm) 13. 20 recipient Blook (2mm- 15 nos and 1.5 -5nos), 100 PCR core recipient tube must be included without additional cost. 14. The system should have built-in digital camera that give a clear image of each donor block, so that user can aim the puncture more accurately. 15. An additional camera should also be there to takes pictures of the block labels. 16. It should be a robust and stable mechanical main unit. 17. It should have intuitive operation control via the keyboard and the mouse of a PC connected to the main unit. 18. One suitable UPS which can manage the system with battery backup of 30 minute must be provided.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 25/2026-2027/Bio Medical Equipt/IGIMS/Store
NAME OF WORK:- A
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 1180
LOCATED WITHIN INDIA.
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
EMAIL ID OF AGENCY
Scheduled Brief description of goods Make: Model: Country of origin Qty./Nos. Ex-factory/ Ex-warehouse/ Ex-Showroom/ off-the shelf (a) Excise duty (If any) % and value. (b) GST (If any) % and value (c) Pcaking and forwarding charge (d) Inland transportation, isurancer for a period inculing 3 months delivery, loading/unloading and incidental cost till consignee site. (e) Incidental services (Including installation and commissioning, supervision, demonstration and training) at the consignee site. (f) Unit Price( at consingee site basis (g) a+b+c+d+e+f Total unit price (at consignee site) Basis Rs. 4x5 (g)
TOTAL AMOUNT IN FIGURE
TOTAL AMOUNT IN WORDS
Note: Bidders are requested to submit price bid in above format otherwise the bid submitted will be regected.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 25/ 2026-2027/Bio Medical Equipt/IGIMS/Store
NAME OF WORK:- A
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 1180
COMPREHINSIVE ANNUAL MAINTENANCE CONTRACT PRICES SCHEDULE
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
S. No. Item Description 1st Yr. 2nd Yr. 3rd Yr. 4th Yr. 5th Yr. 6th Yr. 7th Yr. Total Comprehensive annual maintenance contract over a period of seven years after expiry of warranty period of three years from the date of successful installation. (c+d+e+f+g+h+i)
a b c d e f g h i j
1 Name of the equipment Make: Model: Qty:
2 Name of the equipment Make: Model: Qty:
3 Name of the equipment Make: Model: Qty:
4 Name of the equipment Make: Model: Qty:
5 Name of the equipment Make: Model: Qty:
6 Name of the equipment Make: Model: Qty:
7 Name of the equipment Make: Model: Qty:
8 Name of the equipment Make: Model: Qty:
9 Name of the equipment Make: Model: Qty:
10 Name of the equipment Make: Model: Qty:
11 Name of the equipment Make: Model: Qty:
12 Name of the equipment Make: Model: Qty:
13 Name of the equipment Make: Model: Qty:
14 Name of the equipment Make: Model: Qty:
15 Name of the equipment Make: Model: Qty:
16 Name of the equipment Make: Model: Qty:
17 Name of the equipment Make: Model: Qty:
18 Name of the equipment Make: Model: Qty:
19 Name of the equipment Make: Model: Qty:
20 Name of the equipment Make: Model: Qty:
21 Name of the equipment Make: Model: Qty:
22 Name of the equipment Make: Model: Qty:
23 Name of the equipment Make: Model: Qty:
24 Name of the equipment Make: Model: Qty:
25 Name of the equipment Make: Model: Qty:
26 Name of the equipment Make: Model: Qty:
27 Name of the equipment Make: Model: Qty:
28 Name of the equipment Make: Model: Qty:
29 Name of the equipment Make: Model: Qty:
30 Name of the equipment Make: Model: Qty:
31 Name of the equipment Make: Model: Qty:
32 Name of the equipment Make: Model: Qty:
33 Name of the equipment Make: Model: Qty:
34 Name of the equipment Make: Model: Qty:
35 Name of the equipment Make: Model: Qty:
36 Name of the equipment Make: Model: Qty:
37 Name of the equipment Make: Model: Qty:
38 Name of the equipment Make: Model: Qty:
39 Name of the equipment Make: Model: Qty:
40 Name of the equipment Make: Model: Qty:
41 Name of the equipment Make: Model: Qty:
42 Name of the equipment Make: Model: Qty:
43 Name of the equipment Make: Model: Qty:
44 Name of the equipment Make: Model: Qty:
45 Name of the equipment Make: Model: Qty:
46 Name of the equipment Make: Model: Qty:
47 Name of the equipment Make: Model: Qty:
48 Name of the equipment Make: Model: Qty:
49 Name of the equipment Make: Model: Qty:
50 Name of the equipment Make: Model: Qty:
Scope of contrct (details as mentioned in the clause No. - 13 of "Instruction to Bidder" & Clauses No. 3,4 and 5 of Condition of Condition of Contract".)
a) The rate of Comprehensive Annual Maintenace Contract as mentioned above shoul cover the Complete system.
Complete System should include the basic unit and allied supporting components like UPS, stabilizer Computer System,
Printer, De-ionizer, dehumififer etc to be supplied by the bidder along with basic unit.
b) Preventifve maintenance visit: Four Maintenance visits at ragular interval for usual mintenance & supervision failing which
25% of the contract amount per visit would be deducted as penalty.
c) Break down maintenance visit: As & when requrd
d) Response Time: Within 48 Hours.
e) Uptime Guarantee: 95% of 365 days
f) The above-mentioned charges should includes labour charges for maifntenance and breakdown visits per year, spares,
accessories and all type of consumables requird for the maintenaed charges: it should be clearly mentiond with frequency of
replacement and with rate. The validity of rate of suchf items should also be mentioned vclearly. What will be the rate of
such item must be mentioned.
g) Payment of Comprehensive Annual Maintenance Contract would be made on half yearly basis after completion of work and
satisfctory working report . In no case, advance payment is to be considerd.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Bidding Doc...pdf
NIT • 1.36 MB
Technical Sheet.xls
NIT • 0.21 MB
179489600830.pdf
NIT • 0.97 MB
BOQ.xls
NIT • 0.20 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .