Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAdmitted-Finance | ₹1.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.8 Cr+₹1,059.50 (<0.01%)Admitted-Finance | ₹1.8 Cr+₹1,059.50 (<0.01%) | L2 | Admitted-Finance |
| 3 | L3₹1.8 Cr+₹1,610.16 (<0.01%)Admitted-Finance | ₹1.8 Cr+₹1,610.16 (<0.01%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s G.Thaninjao R.Naga and Sons L1 | LAISHRAM JAMES L3 | Yumnam Somendro Singh L2 |
|---|---|---|---|---|---|---|
| 1.00EARTH WORKS: | ||||||
| 1.10 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m. including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. a) All kinds of soil | 130.1 | Cum | 310 ₹40,331 Lowest | 310 ₹40,331 Lowest | 310 ₹40,331 Lowest |
| 2.00 | Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 90.64 | Cum | 204 ₹18,490.56 Lowest | 204 ₹18,490.56 Lowest | 204 ₹18,490.56 Lowest |
| 3.00 | Supplying and filling in plinth with sandy soil under floors including watering, ramming, consolidating & dressing complete. | 66.11 | Cum | 1,736 ₹1,14,766.96 Lowest | 1,736 ₹1,14,766.96 Lowest | 1,736 ₹1,14,766.96 Lowest |
| 4.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level: a) 1:4:8(1 Cement:4 coarse sand:8 graded stone aggregate: 40 mm nominal size). | 21.64 | Cum | 10,665 ₹2,30,790.6 Lowest | 10,668 ₹2,30,855.52 | 10,667 ₹2,30,833.88 |
| 5.00 | b) 1:5:10 (1 Cement:5 coarse sand:10 graded stone aggregate: 40 mm nominal size). | 22.04 | Cum | 9,927 ₹2,18,791.08 Lowest | 9,930 ₹2,18,857.2 | 9,929 ₹2,18,835.16 |
| 6.00 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (Icement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size). | 32.11 | Sqm | 622 ₹19,972.42 Lowest | 622 ₹19,972.42 Lowest | 622 ₹19,972.42 Lowest |
| 7.00 | Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm bed of dry brick ballast 40 mm nominal size well rammed and consolidated and grouded with fine sand including finishing the top smooth. | 30.6 | Sqm | 938 ₹28,702.8 Lowest | 938 ₹28,702.8 Lowest | 938 ₹28,702.8 Lowest |
| 8.00 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level a) 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) | 49.09 | cum | 14,530 ₹7,13,277.7 Lowest | 14,534 ₹7,13,474.06 | 14,532 ₹7,13,375.88 |
| 9.00 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : a) 1:1.5:3 (1 cement :1.5 coarse sand :3graded stone aggregate 20 mm nominal size) | 28.27 | Cum | 16,011 ₹4,52,630.97 Lowest | 16,016 ₹4,52,772.32 | 16,015 ₹4,52,744.05 |
Tender Value
Refer Docs
EMD Value
₹3.6 L
Closing Date
3 Dec 2024, 6:30 pmClosed
EE Enggcell Hill-II H FW
Directorate of Health Services
Reconstruction oh PHSC Building with Quarter at hengbung Manipur
2024_HFW_2521_1
09/EE/Engg.CellHill-II/HFW/55
Open Tender
Civil Works
Item Rate
730 days
Hengbung Manipur
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,000
Payable To
₹3.6 L
16 Dec 2024
21 Nov 2024
5 Dec 2024
21 Nov 2024
3 Dec 2024
21 Nov 2024
Amount
EARTH WORKS:
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m. including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. a) All kinds of soil
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors including watering, ramming, consolidating & dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level: a) 1:4:8(1 Cement:4 coarse sand:8 graded stone aggregate: 40 mm nominal size).
b) 1:5:10 (1 Cement:5 coarse sand:10 graded stone aggregate: 40 mm nominal size).
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (Icement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size).
Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm bed of dry brick ballast 40 mm nominal size well rammed and consolidated and grouded with fine sand including finishing the top smooth.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level a) 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : a) 1:1.5:3 (1 cement :1.5 coarse sand :3graded stone aggregate 20 mm nominal size)
R.C.C. work in beams, suspended floors, roofs having slope uptp 15o landings, balconies, shelves, chajjas, lintels, band, plain window sills, staircases and spiral staircases above plinth level upto floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with 1 : 1 .5: 3 (1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm nominal size)
Reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete. Above Plinth Level. A) Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for: a) Foundations, footings, bases of columns, etc. for mass concrete
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Suspended floors, roofs, landings, balconies and access platform
Columns, pillars, piers, abutments, posts and struts.
BRICK WORKS:
Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: a) Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with 1st class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in a) Cement mortar 1:3 (1cement:3coarse sand)
Extra for half brick masonry in superstructure, above Floor V level for every four floors or part thereof by mechanical means by lifting materials using mobile crane
Brick edging 7cm wide 11.4 cm deep to plinth protection with 1st class common burnt clay F.P.S. (non modular) bricks i/c grouting with cement mortar 1:4(1 cement:4 fine sand).
Providing wood works in frames of doors, windows, clerestory windows & other frames, wrought frameed & fixed in position with hold fast lugs or dash fastener shall be paid for separately: a) Local best quality Uningthou Wood
Providnig and fixing panelled or panalled and glazed shutters for foors, windows and celestory windows including ISI marked M.S. butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all completely asd per direction of Engineer-in-charge. a) Local best quality Teak Wood 35mm thick shutter
Providing and fixing M.S. grills of required pattern to wooden frames of windows etc. with M.S. flats at required spacing & frames all round bars with round headed bolts & nuts or by screws. A) Fixed to openings /wooden frames with rawl plugs screws etc.
Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required EPDM rubber/ Neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleatangle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steelscrews, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately): For fixed portion. Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) With float glass panes of 4.0 mm thickness
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete a) 250 x 16 mm
Providing and fixing bright finished brass towerbolts (barrel type) with necessary screws etc. complete. A) 250 x 10 mm
Providing and fixing bright finished brass handles with screws etc. complete a) 125 mm
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffinge polishing and making curvature (wherever required) and fittingn the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and laying rectified Glazed Ceramic floor tiles 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours White, Ivory, Grey, Fume Red.. Brown, laid on 20mm thick cement mortar 1:4 (I Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigments etc., complete
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% nad conforming to IS:15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. a) Size of tile 600x600 mm
Providing and laying Vitrified tiles in floor in diffe rent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.080/0 and conforming to 19.15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will bo done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size a) Size of Tile 600x600 mm
Marble stone flooring with 18mm thick marble stone (sample Of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with: a) Raj nagar Plain
Tile work in skirting, risers of steps and dado (upto 2 m height) over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shade complete. a) Marbles tiles (polished) Raj Nagar 8mm thick
Providing and fixing glazing in aluminium door, window. ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-chargo . (Cost of aluminium snap beading shall be paid in basic item): a) With float glass panes of 5.5 mm thickness
FINISHING:
Cement plaster (1 cement: 3 coarse sand) finished with a floating coat of neat cement a) 12 mm cement plaster
15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : a) 1:3 (1 cement: 3 fine sand)
15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall.
Providing and applying white cement based putty of average thickness Imm,of approved brand and manufacturer, over the plasterod wall surface to prepare the surface even and smooth complete.
Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work, over and including priming coat of whiting to give an even shade:-
Finishing walls with textured exterior paint of required shade: a) New work (Two or more coat applied @ 3.28 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 sqm)
Applying primimg coat With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
(1.2) Wiring for light point /fan pt./ Exhaust fan pt./Call bell pt./ with 1.5 mm ² FRPVC insulated copper conductor single core cable in surface/ recessed steel conduit with modular type switch modular plate suitable G.I box and earting the point with 1.5 mm ² FRPVC insulated copper conductor single core cable etc as required a) 1) Gr A
(1.68) S/F suitable size G.I box with modular plate and cover infront on surface or recess i/c P/F 3 pin 5/6 amp modular socket outlet 5/6 amp modular switch,connectionpainting etc as reqd.
Suitable size GI box with modular plate and in front on surface or in recess i/c p/f 6 pin 16/15 amp modular socket outlet 15/16 amp modular switch, connection painting etc as required
(1.7) wiring for circuit/ submain wiring along with earth wire with the (following size of) FRPVC insulated copper conductor single core cable in surface/recessed steel conduit etc as reqd. a) 1) 2x1.5mm²+ 1x1.5mm² Earth wire
2) 2x4.0mm²+ 1x4.0mm² Earth wire
3)2x6mm²+1x6mm² Earthwire
(1.87) S/F (following way) single pole and neutral, sheet steel MCCB DB 240 v on surface /recessed complete with tinned copper busbar, neutral busbar, earthbar, dinbar, hinged front acrylie cover for the MCCB knobs datacable grand plate, enter connnection, phosphatised and power painted including earthing etc, as required ( but without MCB/RCCB/ isolator) a) (1) 2 + 4 way
(1.107) S/F 5amp to 32 amp rating 230 V "B" series for lighting and other purposes, load of (following poles)in the existing MCB DB complete with connection, testing and commissioning etc as required. A) (2) Single pole and neutral
(1.109) S/F (following rating) double pole 240 V isolator in the existing MCB DB complete with connection testing and commissioning as required. (1) 40 Amp
(1.84) P/F (following capacity TP&N) dis-connector fuse switch unit inside the exiting cubicle panel board with I.S.I mark HRC fuses i/c drilling holes in the cubicle panel board making connectio n as reqd. (1) 200 Amp TP & N
(2) 100 Amp TP & N
P/F 200Amp TPN stand ground on load on load change own switch (compact design) 415/500v including connection to as required.
(8.01) S/F 48” sweep (1200mm)a.c ceiling fan complete with down rod, canopy, 3 Blades but without regulator etc. as reqd. (Havells or similar 5 star)
(1.62) s/f stepped type electronic fan regulator on the modular plate switch box i/c connection but excluding modular plate etc as reqd.
(8.52) s/f LED down lighter .
(1.71) s/f brass batten holder i/c connection etc as reqd.
(1.71) s/f LED white lamp, 18 W.
SANITARY
Earth work in excavation in foundation trenches or drains i/c. dressing of sides and ramming of bottoms lift upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m in Hard dense Soil
Filling available excavated earth(excluding rock) in trenches, pinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidation each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5m.
Providing and laying cement concrete in foundation. Plinth excluding the cost of centering and shuttering in 1 : 4 : 8 ( 1 cement :4 c/sand : 8 graded stone aggregate. 40mm. nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement- All work up to plinth level: (a) 1:1.5:3 ( 1 cement :1.5 c/sand :3 graded stone aggreate 20 mm nominal size )
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with ( a) 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforcement for RCC work including Straightening, cutting, bending, placing in position and binding all complete. (a) Thermo-Mechanically treated bars.
Providing form work i/c shuttering and centering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m. And removal of the same for in-situ reinforced concrete and plain concrete work in a) Foundation, footings, bases of columns etc. and mass concrete.
b) shelves (cast in situ)
c) Edges of slab and breaks in floor walls above 20 cm wide
15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand)
Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fitting with solvent cement, tenching, refilling & testing of joints complete as per direction of Engineer in charge. A) 75 mm dia
110 mm dia
Supplying and fixing C.I. Cover with frame (for manhole and chambers) 600x450 mm rectangular C.I. Cover (light duty) 23 kg
Providing and fixing 600x450 mm bovolod cdgo mirror of superior glass (Of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass scrows and washers complete.
Providing and Fixing 600x20mm C.P brass towel rail complete with C.P brass brackets fixed to wooden cleats with C.P brass screws (hook type)
Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete White solid plasticseat with lid.
P/F white vitreous china wash basin i/c making all connections but excluding the cost of fittings Flate back wash basin of size 450x300 mm
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with scat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually con trolled device (handle lever). conforming to IS : 7231. with all fittings and fixtures complete. including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
P/F 8mm dia C.P./SS Jet with flexible tube upto 1 metre long with triangular plate to European type W.C. of quality and make as approved by E ngineer-in-charge
P/FP.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all. 10 litre capacity -white
P/F P.V.C. waste pipe for sink or wash basin i/c P.V.C. waste fittings complete. Flexible pipe 32mm dia.
Providing and fixing grating of approved quality for Nahni trap. Stainless steel 100 mm nominal diameter
Providing and placing on tcrrace (at all floor levels) polyethylene per litre 10.20 water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and tho baso support for tank.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps i/c cutting and making good the walls etc. (Internal work). 25 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
15 mm nominal outer dia Pipes
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to 1S.8931. a) 15 mm diameter
Providing and fixing brass bib cock of approved quality 15 mm nominal bore
EARTH WORK
Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms lift upto 1.5 metres including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres Loose/Soft Soil
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre
CONCRETE WORK
Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Reinforcement for R.C.C. work i/c. bending, binding and placing in position complete. TMTbars
RE-INFORCED CEMENT CONCRETE WORK
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in beams suspended floors, roofs having slope up to 15 degreee landing, balconies,shelves, chajjas lintels,bands, plain window sills stair cases,and spiral stair cases up to floor five level excluding the cost of centering shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in columns, pillars, piers, abutments, post and struts upto floor two level i/c plastering the exposed surface with cement 1:3 (1 cement:3 fine sand(Kanhaighat sand)) of thickness not exceeding 6 mm thickness to give a smooth and even surface but excluding the cost of centering-shuttering & reinforcement 1:1.5:3(1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal sizes
FORMWORK
Providing form works i/c centering and shuttering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 m and removal of the same for in-situ reinforced concrete and plain concrete work in a)Foundation, footings, bases of columns etc. and mass concrete.
c) Lintel, beam, plinth, girder, bressumers and cantiliver
b)Columns, pillars, posts and struts (square, rectangular or polygon in plan).
BRICKWORK
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 cement: 4 coarse sand)
FINISHING
12 mm cement mortar 1:4 (1 cement :4f/sand )
15 mm cementplaster 1:4 (1cement :4f/sand )
CEMENT PAINTING:- WITH WATER PROOF CEMENT PAINT
Applying one coat of cement primer of approved quality on wall surface.
Finishing walls with water-proofing cement paint of approved quality on new work (three or more coats) to given shade.
Painting on wall with (two coats) of plastic emulsion paint of approved quality in all shades on new work to give an even shade.
Painting (two or more coats) with synthetic enamel paint of approved quality all shades except black or chocolate on steel on new work to give an even shade.
Steel work welded in built up sections, framed work in cutting, hoisting, fitting in position & priming coat of red lead paint . In channel, angles & tees.
Providing & fixing Cast iron Spear head over the top of steel grills
Yumnam Somendro Singh (BID ID -8247)
LAISHRAM JAMES (BID ID -8248)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .