Irugur TOP Installation, Bharat Petroleum Corporation Limited
SUBJECT: TENDER FOR SSUPPLY & INSTALLATION OF SEMI AUTO TWIN DISTILLATION UNIT AT IRUGUR TOP INSTALLATION CRFQ NO 1000391120 DATED ON 09.08.2022 Kindly quote you lowest rate per unit against each item in figures as well in words and your rates are valid for a period of 60days up to 30.10.2022.After successful completion of contract period ,Repeat order shall be placed on mutual agreement. The quoted amount shall inclusive of all rates, taxes and duties but excluding Goods & Service tax will be paid extra as per prevailing rates and policy /rules and regulations. Kindly note that this is an e- tender and bids have to be submitted only online. Your offer is liable to be rejected if there is any deviation from terms and conditions and special conditions of the said tender. Following five documents are uploaded as tender documents. You are requested to sign all documents digitally and upload all documents in the tender without any corrections. Please note that even if a single document is missed while digitally signing uploading; the bid is tantamount to reject. Conditional bids will also be liable for rejection .No changes shall be made in the tender documents and it should be digitally signed and uploaded as it is. Tender Documents 1. Tender Covering Letter. 2. General Conditions of Contract 3. General Purchase Contract 4. Bid Security Declaration During the technical evaluation above parameter of successful digital signing and uploading of tender documents will be checked. Your offer digitally signed on all pages of bid and attached tender documents files should be signed digitally and uploaded in the e- procurement portal of BPCL on or before 26.08.2022 @ 1600 Hrs. BPCL will not be held responsible for any delays due to connectivity issues etc. The rates should be quoted for the specifications mentioned in the tender only and no deviation will be entertained. Any deviation found in the bid; same will be liable for disqualification. You may kindly contact us if in case you need any clarifications before submitting your offer. <span lang="EN-US" style="font-size:10.0pt;font-family:"Arial",sans-s
5069
1000391120
Limited Tender
Works
Irugur TOP Installation
31 Aug 2022
9 Aug 2022
31 Aug 2022
9 Aug 2022
31 Aug 2022
9 Aug 2022
Test method in conform with ASTM D 86, & D 126, IP 123, IS 1448 ( P -18 ) method.
Instrument having, both cooling and heating system, to work at below ambient and above ambient
temperature.
Cooling system:
Water bath : Made out of SS of 304 grade in 14 SWG thickness
Outer wall : Made out of SS of 304 grade in 16 SWG thickness
Type of the bath : Rectangular, double walled
Joints welding : Either by silver brazing or TIG welded for leak proof ever
Insulation : PUF insulated, in the thickness of 25 mm.
Drain valve : Provided at the bottom of the tank. Ball valve size is ½” BSP
Cooling condenser(In side bath) : 2 numbers will be provided in the bath itself
Condenser made out of : Copper pipe, in 14 mm OD, duly nickel coated
Condenser size : 560 mm + / - 5 mm
Temperature : For cooling from ambient to 2’C
: For heating from ambient to 70’C
For cooling in the bath : Refrigeration system to be provided
Refrigeration system : It comprises of hermetically sealed compressor, air cooled
condenser, self cooled motor to cool condenser, drier (Danfos
or Emerson make),suitable capillary, CFC free refrigerant. As
per the capacity of the compressor, condenser and cooling
motor to be provided.
For heating in the bath : Immersion heater in 1.5 KW rating to be provided. This tank
capacityto be around 18 to 20 lits
Temperature control for bath : Digital temperature controller, micro processor based, with SV
and PV options (Set value and processing value),eurotherm
make with accuracy of 0.1 deg cen
Type of sensor for bath : preferably PT 100 for bath
External circulatory system : Stirring motor provided on the top of the bath
Stirrer : Shaft and stirring blades are made out of SS of 304 grades
Number of metal shields to be given : Two numbers (For heater units)
Metal shield made out of : SS of 304 grades
Thickness of the shield : 20 SWG
Size of the shield : As per ASTM it should be 490 to 500 mm in height
: 200 mm x 200 mm width x width
Front view : Provided with toughened glass
Heating source : By non magnetic heating wire (In helical form)
Wire rating : 1000 Watts for MS and 1500 Watts for Diesel distillation
Heat control : Digital, :
Support, supported on : Moving type platform (Up and Down movements)
Indicator lamps : Provided for both Mains indicator and current controlling
Flask supporting plates : Ceramic plates.
Power supply : Single phase, 230Volts, 50 Hz
Scope: To determine the Distillation characteristics of Petroleum Products having boiling range
between 20 – 400degC at Atmospheric pressure.
Apparatus: The equipment should have rugged construction. It should be a compact self-contained
instrument with factory filled CFC-free cooling system, delivered with all accessories to immediately
begin testing. It should be the latest model and shall have the following features:
1. SEMI AUTOMATIC distillation Apparatus conforming to P – 18 &ASTM D-86 (group 2, 3 & 4).The
apparatus must be a Dual unit with standalone operation facility.
2. Apparatus should have capacity to perform physical distillation of liquid petroleum products
(boiling range 20-400°C) including upto 10% ethanol blended gasoline and upto 20% biodiesel
blends by means of measuring vapor & liquid temperatures in the distillation flask.
3. Apparatus should have capacity to test samples from group 2 to 4, and solvents as per ASTM
D1078 and D850.
4. Instrument shall be able to test sample from ambient till 450 °C temperature.
5. Appropriate heating system safe from electrical hazard which shall be able to maintain uniform
distillation rate by the operator as per the method (4-5 ml /minute) with a mechanical lifting device
in aligning the distillation flask.
6. The equipment shall have appropriate voltage heater with a mechanical lifting device for precise
positioning of distillation flask. The heater shall have a provision to lower manually after
completion of the test.
7. Should have CFC free sealed refrigeration system with high efficient cooling system able to
cool/warm 0 to 65 deg. C and vice versa in less than 30 minutes for condenser and receiver
chamber. Controller shall be able to maintain the temperature of the bath with in ±1 deg C.
8. Party to provide Calibration certificate and traceability for all temperature measurement system
PT 100 probe. (vapour temperature).
9. The apparatus should be supplied with essential consumables/spare parts for 2 years operation
considering 1500 distillations per year. (Note : The distillation flasks should be made of heat
resistance glass and constructed as per the dimensions of ASTM D 86).
Vendor shall provide following accessories
a. The party to provide 2 Nos of PT 100 probe calibrated from NABL accredisted laboratory.
b. 12 nos of distillallation flasks (borosilicate glass capable of withstanding temperature of
about 450 deg C.)
c. 3 nos of distillation cylinders.
d. Flask supports (ceramic make) 50mm and 38mm: 5 nos each.
e. Condenser swab : 4 nos
f. Drip plates: 02 nos.
10. To provide the List of 2 Indian users, preferably in the field of Petroleum/Petrochemicals.
11. The offer should be complete in all respect and instrument should be ready to use. In case of the
instrument being non-operational for want of spares or accessories not mentioned in the offer,
the vendor shall have to supply the same and bring back the instrument in working condition
without any charge whatsoever.
12. Powers supply 230 VAC 50/60 Hz.
Guarantee & Equipment Acceptance
13. Party to provide 1 yr. Guarantee of performance of the equipment. Equipment should have 2 yr
warranty for Maintenance and complete replacement for any component / unit against any
manufacturing / operational defects / problems/software upgradations free of cost within warranty
14. The offer should be complete in all respect and instrument should be ready to use. In case of the
instrument being non-operational for want of spares or accessories not mentioned in the offer,
the vendor shall have to supply the same and bring back the instrument in working condition
without any charge whatsoever.
15. The vendor should enclose the technical compliance statements against our technical
specifications clearly mentioning Yes or No for various points. The statement should be
supported by relevant literature/data/actual testing and/or inspection.
16. Should demonstrate the required precision and accuracy of instrument as per ATSM D 86 through
testing of minimum 5 samples of MS, 5 samples each of HSD, SKO and ATF provided by BPCL
in presence of our representative.
17. Delivery period & pre installation requirement to be clearly mentioned in the quotation
18. Copies of Manual (Maintenance & Operation) in hard as well as soft form in English to be supplied.
19. Party should install and commission the equipment within 3 weeks of delivery of the equipment
and necessary training should be imparted for operation, maintenance free of charge.
Safety Features
1. All electrical fittings shall be with fire proof wiring.
2. To prevent over heating in the event of primary controller failure, a high limit elelctronic lock
shall be provided to interrupt power to the bath beyond a temperature of 120 deg C.
3. Sufficient insulation to be provided to avoid electrical shocks and hazards.
General terms & Condition
1. The supply and installation of copper corrosion bath to done at
QA LABRATORY
BPCL IRUGUR TOP INSTALLATION,
RAVATHUR P.O., IRUGUR VIA,
COIMBATORE
TAMIL NADU-
2. The payment will be made after successful supply & installation of subject item. The bill should
be addressed to Business Process Excellence Centre (BPEC) 4th Floor, BPCL Office
Complex Plot No. 6, Sector – 2, Behind CIDCO Garden, Kharghar, Navi Mumbai - 410
with a copy to us.
3. Payment will be released through NEFT directly to the Vendor's account.
4. BPCL reserves the right to modify /cancel in full or part/extend due date without assigning any
reasons at their discretion and contractors have no right seeking reasons for such actions by
5. BPCL reserves the right to terminate the contract (in part or full) before its expiry without giving
any reasons at their discretion and the contractor will not have any right for any
claims/damages with BPCL on account of this. Contractor is fully responsible for any
consequences/loss/liabilities/risks solely in case the contract is terminated before expiry of
the contract period. The equipment should be complete in all respect and instrument should
be ready to use. In case of the instrument being non-operational for want of spares or
accessories not mentioned in the offer, the vendor shall have to supply the same and bring
back the instrument in working condition without any charge whatsoever.
6. Party shall provide any pre-installation requirement before delivery for smooth commissioning
of the instrument.
7. Party shall install and commission the instrument within 90 days from the date of issue of LOI
8. Party shall supply, operation and maintenance manual including that of the controller.
9. Party shall provide 24 months warranty to the supplied instrument and spares from the date
of successful commissioning at BPCL site (QA laboratory, BPCL Irugur TOP Inst., Coimbatore
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
5069.pdf
pdf • 2.28 MB
BUDGETDOC_5069.pdf
pdf • 0.57 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .