GE (AF) FARIDABAD
GE (AF) FARIDABAD
PROVN OF RO WATER BOTTLE WASHING SYSTEM AND DISTRIBUTION OF WASTE WATER OF RO AND RENOVATING OF BLDG NO P-137 SWT-02 ALONG WITH ASSOCIATED BR AND EM WORKS AT AF STN FARIDABAD IN AOR OF GE (AF) FARIDABAD (2ND CALL)
2023_MES_592992_2
GE (FBD)/AF-11/2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Faridabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Faridabad
₹86,000
Yes
21 Sept 2023
6 Jun 2023
22 Jun 2023
6 Jun 2023
20 Jun 2023
6 Jun 2023
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mm complete all as specified and directed by Engineer-in-Charge.
Supply, laying, spreading dry, clear sand in trenches including spreading, levelling, punning for cushioning of cable complete all as specified and directed by Engineer-in-Charge.
Supply and laying in trenches, LT underground cable of size 3.5 core 50 Sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands jointing materials etc.laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as specified and directed by Engineer-in-Charge. Make - KEI, Polycab, Havells.
S&L GI tubing light grade 40 mm bore intrenches/fixing on pole/wall/crossing in drain etc. for protection of UG cable complete all as specified and directed by Engineer-in-Charge.
Taking Down carefully Copper/aluminium Point Wiring (light, fan,socket or Power) complete,(fittings Such as switches, ceiling roses, pendents, regulators sockets etc, to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer-in-Charge.
Taking down carefully aluminum two core sub main wiring of sizes 6 Sqmm /4 Sqmm cable any type and removing old material from site and making good disurbed surface complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring in repairs complete with 1.5 sqmm single core multistranded copper conductor PVC insulated and unsheathed cable 1100 volts grade FRLS cable IS-694 marked drawn through and including rigid non metallic PVC heavy duty concealed conduit(min 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.12.5 of SSR Part I ) ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends.tees, juction boxes etc fixed concealed in wall/ceiling or surface conduit on ceiling with provision of 2 mm thick pressed steel terminal boxes covered with 3 mm thick plastic laminated white /coloured top cover for mounting switch,socket,fan regulator,industrial socket and all lamp fittings etc including 1.5 sq mm PVC insulated but unsheathed copper conductor FRLS cable,1100 volt grade IS-694 marked as earth contuinity wire for for one light point/Fan point/bell point controlled by one way switch complete all as specified and directed by Engineer-in-Charge. Make - Polycab/Havells/KEI, Anchor.
All as per Item No.10 mentioned here-in- before but on the same board with 1.5 sq mm PVC insulated copper conductor for continuous earthing complete all as specified and directed by Engineer-in-Charge.
All as per item No.10 mentioned here-in- before but one three pin 5 Amps socket out let on independant board with 1.5 sq mm PVC insulated copper conductor for continuous earthing complete all as specified and directed by Engineer-in-Charge.
All as per item No.10 mentioned here-in- before but 15 Amps 3 pin socket outlet on independent board with 2.5 sq mm PVC insulated and sheathed copper conductor with 2.5 sq mm PVC insulated copper conductor single core for continuous earthing complete all as specified and directed by Engineer-in-Charge.
All as per item No.10 mentioned here-in- before but for Single pole and neutral enclosure with 4.0 sq mm PVC insulated and sheathed copper conductor with 4.00 sq mm PVC insulated copper conductor single core for continuous earthing complete all as specified and directed by Engineer-in-Charge.
S&F Piano switch in repairs, flush button single pole one way 6 Amp complete all as specified and directed by Engineer-in-Charge. Make - Havells, Anchor, Cona/Legrand.
S&F bell push, in repairs, flush type 5 Amps complete all as specified and directed by Engineer-in-Charge. Make - Havells, Anchor, Cona/Legrand.
S&F socket outlet, in repairs, flush type 2 in 1, 3 pin 6 Amp complete all as specified and directed by Engineer-in-Charge. Make - Havells, Anchor, Cona/Legrand.
S&F socket outlet, in repairs, flush type 2 in 1, 3 pin and 6/16 Amp complete all as specified and directed by Engineer-in-Charge.
S&F Piano switch in repairs, flush button single pole one way 16 Amp complete all as specified and directed by Engineer-in-Charge. Make - Havells, Anchor, Cona/Legrand.
S&F stepped type electronic fan regulator, in repairs, flush type on the existing phenolic laminated sheet etc complete all as specified and directed by Engineer-in-Charge. Make - Havells, Anchor, Cona/Legrand.
S&F ceiling rose surface backlight, 65 x 50 mm three terminals complete all as specified and directed by Engineer-in-Charge. Make - Havells, Anchor, Cona/Legrand.
S & F in repairs Bell ,Bell Multi Music type,240 Volts complete all as specified and directed by Engineer-in-Charge. Make - Havells, Anchor, Cona/Legrand.
S & F Sheet metal Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 V complete all as specified and directed by Engineer-in-Charge. Make - Legrand/L&T/Havells/Seimens/Hager.
Supply and Special Purpose metal enclosures for VTPN suitable for MCCB upto 125 Amps as incomer distribution board 415 Volts optium F1+12, 4 way double door IP-54 protection including flushing the DBs inside the walls and making good the disturbed surface also matching with the existing surface complete all as specified and directed by Engineer-in-Charge. Make - Legrand/L&T/Havells/Seimens/Hager.
Supply and fixing 100 Amps MCCB four pole, 16 KA, 415 Volts,50 Hz Adjustable type complete all as specified and directed by Engineer-in-Charge.Make - Legrand/L&T/Havells/Seimens/Hager.
Supply and fix sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 12 way Double door with 200 Amps rated busbar complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface complete all as specified and directed by Engineer-in-Charge. Make - Legrand/L&T/Havells/Seimens/Hager.
Supply and fix sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 8 way Double door with 200 Amps rated busbar complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface complete all as specified and directed by Engineer-in-Charge. Make - Legrand/L&T/Havells/Seimens/Hager.
Supply and fix sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 4 way Double door with 200 Amps rated busbar complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface complete all as specified and directed by Engineer-in-Charge. Make - Legrand/L&T/Havells/Seimens/Hager.
Supply and fix MCB Triple pole and Neutral , 415 volts, 63 Amps 10 KA, 'C' grade complete all as specified and directed by Engineer-in-Charge. Make - Legrand/L&T/Havells/Seimens/Hager.
Supply and fix MCB Triple pole and Neutral , 415 volts, 25 Amps 10 KA, 'C' grade complete all as specified and directed by Engineer-in-Charge. Make - Legrand/L&T/Havells/Seimens/Hager.
S&F in repairs MCB SPN 6 to 32 Amps, 240 Volts,"B" grade complete all as specified and directed by Engineer-in-Charge. Make - Legrand/L&T/Havells/Seimens/Hager.
Supply and fix MCB single pole, 240 volts, 6 to 32 Amps 10 KA complete all as specified and directed by Engineer-in-Charge. Make - Legrand/L&T/Havells/Seimens/Hager.
M&L two single core PVC insulated cable with copper conductor multi stranded 6 Sqmm in and incl. duly drawn through and including concealed PVC conduit suitable size as sub main with continuous earth wire 6 Sqmm size and connecting to common earth dolly all complete complete all as specified and directed by Engineer-in-Charge.(Flexible Copper Wire Used In FRLS) Make - Polycab/Havells/KEI, Anchor.
All as per item No.33 mentioned here-in- before but 4.0 sq mm PVC insulated and sheathed copper conductor with 4 sq mm PVC insulated copper conductor single core for continuous earthing complete all as specified and directed by Engineer-in-Charge.
All as per item No.33 mentioned here-in- before but 2.5 sq mm PVC insulated and sheathed copper conductor with 2.5 sq mm PVC insulated copper conductor single core for continuous earthing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED , Tube light fitting 20 W, 6500K Intenso AX LED batten aluminium profile self ballasted surface mounted LED Batten extruded aluminium body with PC diffuser in unic shape. >180º wide light distribution. soft glare free light complete accessories prewired and including provision of three core textile braided copper conductor flexible wire from ceiling rose to light fitting complete all as specified and directed by Engineer-in-Charge. Make - Havells/Bajaj/Wipro/ Philips.
Supply and fixing LED , Tube light fitting 12 W, 6500K Intenso AX LED batten aluminium profile self ballasted surface mounted LED Batten extruded aluminium body with PC diffuser in unic shape. >180º wide light distribution. soft glare free light complete accessories prewired and including provision of three core textile braided copper conductor flexible wire from ceiling rose to light fitting complete all as specified and directed by Engineer-in-Charge. Make - Havells/Bajaj/Wipro /Philips.
Supply and fixing LED 14 Watts 230 V, with Control driver with efficiency 90 % ,attractive type sleek LED mirror light 2 feet fitting with high output diffuser prewired inluding all accessories and connecting up with twin core twisted copper conductor with suitable size complete all as specified and directed by Engineer-in-Charge. Make - Havells/Bajaj /Wipro /Philips.
S&F in repair energy efficient LED building secruity lights 1x30W with lens, PDC aluminium body and toughened glass visor fitted in frame secondary optical lens for superior light distribution efficay >100 Lm/W, CCT 5700K, IP-65 complete with bracket/clamps, nut bolts and washers suitable for fitted in building complete all as specified and directed by Engineer-in-Charge.Make - Havells/Bajaj/Wipro /Crompton.
Supply and fixing LED-Post top 40 Watts, 230 V, IP 65, 5700K rated with control driver with efficiency 90% pure coated aluminium die cast and spun aluminium body with clear/opal diffuser suitbale for landscape lighting for uniform illumination prewired including all accessories and connecting up with twin core copper conductor with suitable size complete all as specified and directed by Engineer-in-Charge. Make -Polycab Cat No. PCGLP 01 40 C or equivalent to Wipro/Philips/Havells.
S&F Fresh Air fan 250 mm sweep, 240 Volt AC single phase complete all as specified and directed by Engineer-in-Charge. Make - Standard/Havells/USHA/Crompton.
S&F exhaust fan heavy duty metal body with louvers of size 300mm sweep, 1400 RPM including making holes in existing bricks/stone wall and fixing arrangements complete all as specified and directed by Engineer-in-Charge. Make - Standard/Havells/USHA/Crompton.
Supply and Fixing 40 watts 5700 K Recess mounting Back lit LED Panel having white Polycarbonate body & Aluminium plate heat sink, high quality PMMA diffuser and HPF driver suitable for Gypsum, POP, Armstrong and Grid ceiling and complete all as specified and directed by Engineer-in-Charge. Make : Polycab/Philips/Wipro/Bajaj /Crompton.
Supply and fix wall mounted cabin fan super high speed portable 450 mm sweep, 220-240 volt AC,50 Hz sigle phase with Thermal overload protected motor complete all as specified and directed by Engineer-in-Charge. Make.Standard/Havells/Crompton/Bajaj.
Supply and Fix Efficiencia BLDC(Brushless Direct Current) power saver Ceiling fan 1200 mm sweep with remote and connecting up including provision of cable from ceiling rose/connector to Ceiling fan complete all as specified and directed by Engineer-in-Charge. Make – Bajaj/Crompton/Usha.
Supply and fixing Storage water heater(Geyser) 25 lts cap 5 star rating complete with water pipe line connection incl cutting the existing pipe complete all as specified and directed by Engineer-in-Charge. Make - Havells/Racold/Bajaj/Crompton. Note: PVC connection 02 Nos (for hot& cold water inlet and outlet) upto 1 mtr length of each included in the unit quoted rate.
Supply and install hi wall split units indoor/outdoor with inverter power indoor/outdoor with inverter power supply (V/Hz/Ph) 230/50/1 phase complete with cordless remote control unit and with in built air ioniser, blue fins and plasma filter for better indoor air quality with high EER twin rotary compressor-BLDC, copper condenser coil, variable speed compressor which adjusts power depending on heat load energy efficient and lowest-noise operation capacity: 1.5 ton suitable for large sized rooms, Energy Rating: 5 star rated having ISEER value 4.60, Regrifgerant gas : R 32/R-134a, Environment friendly- no ozone depletion potential & low global warming potential with suitable MS mounting stands for indoor and outdoor unit includig connecting Cu tubings, drain pipe, connecting Cu cable and Cu power cable complete all as specified and directed by Engineer-in-Charge. Make - Voltas/LG/Blue Star/Carrier NOTE : (a). The rate deemed to be included the rate of labour for taking down the old unsrviceable ACs (b). The rates quoted shall deem to include the cost of cutting holes in the brick wall for passing copper tubing and making good the surfcaes to match with adjoining surfaces include fixing with angle iron into any type of wall for out door unit whereever reqd. (c). The cost of copper tubing of size 5/8" and 1/4" with suitable insulation up to a length of 4.5 mtr is deemed to be included in the unit rate quoted. Cost of copper tubing of size 5/8" and 1/4" with suitable insulation beyond 4.5 mtr will be measured and paid separately under the relevant item.
Supply and fix voltage stablizer for automatic operation/single phase AC supply 230V 50 Hz naturally air cooled indoor type designed for input variation between 170V to 270V with output valtage stablizer at 230V with accuracy of (+) or (-) 2.50% and capacity 5 KVA complete all as specified and directed by Engineer-in-Charge. Make - V-Guard/Microtech/Luminous.
M&L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick buried in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to galvanised earth lead wire 4 mm GI earth continuity conductor including 15 mm bore pipe Light grade for protection of lead by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel connected to maint switch control board upto 7.5 mt away from earth electrode all as shown as per plate No 05 of SSR part - I including necessary earth work, PCC 1:3:6 type C1 chamber, RCC cover slab of 50 mm thick 1:2:4 with 8 mm CTD 140 mm C/C with suitable handle, watering pipe 20 mm dia light grade pipe with funnel, charcoal, salt and testing on completion and including taking old unserviceable earthing with connected items complete all as specified and directed by Engineer-in-Charge.
Supply and fixing cold water flow meter flange type end digital type 80 mm including rubber gaskjet,flange and tail piece in existing CI pipe line with standard ISO:4064/1 complete all as specified and directed by Engineer-in-Charge. Make - Kranti or equivelent.
S&F Rotational moulded polye?thylene water storage tank 10000 ltrs cap (cylindrical vertical with closed top) hoisted double layer with tank diameter 100.3", length 97.6" and manhole diamter 20" and fixed in position complete all as specified and directed by Engineer-in-Charge.Make - Sintex/Sheetal.
M & L for PCC 1:2:4 type B1,20mm graded aggregate to base for a sintex tank complete all as specified and directed by Engineer-in-Charge.
Supply, laying & jointing of following HDPE/UPVC pipes IS 4984 :2016 and Compression Push fit type fittings/ ASTM UPVC Fitting including (COMPRATION /ASTM FITTINGS,(Comp. Elbow, Tee, End Cap. MTA For HDPE Pipe), ASTM FITTING (FLANGE( including excavation, removal and returning filling of any type of soil/road/wall of size 300 mm Depth, 250 mm wide) complete all as specified and directed by Engineer-in-Charge. Make - Godavari,Smartflow
(a) HDPE PIPE ISI 63 mm OD PE 100 PN 6
(b) HDPE PIPE ISI 50 mm OD- PE 100 PN 6
(c) HDPE PIPE ISI 40 mm OD- PE 100 PN 6
(d) ASTM UPVC Pipe 50 mm SCH-40 Make - Ashirvad /Astral/vectus
(e) ASTM UPVC Pipe 40 mm SCH-40 Make - Ashirvad /Astral/vectus
(f) ASTM UPVC Pipe 32 mm SCH-40 Make - Ashirvad /Astral/vectus
(g) ASTM UPVC Pipe 15 mm SCH-40 Make - Ashirvad /Astral/vectus
Supply, Installation, Testing & commissioning of 3/4" Rotar Sprinker full/part circle having radius of 6.7m - 12m @ 2.5 - 4.5 bar with discharge of 0.09 - 0.61 ltr./sec. the sprinklers having Arc Adjust thru top Cover w/ Std. Screwdriver complete all as specified and directed by Engineer-in-Charge. Make: Rain Bird / Hunter
Supply, Installation, Testing & commissioning of 3/4" Pop up Connecting Swing joint assembly, the tubing shall be made of polyetylene having wall thickness of 2.3mm ,a working pressure of 5.5 kg/cm2 at 43 degree Centigrade and a surge pressure of 16.6 kg/cm2. The fittings shall be made of UV resistant thermo plastic SA Series complete all as specified and directed by Engineer-in-Charge. Make : Rain Bird/Hunter/Elitech
Supply, Installation, Testing & commissioning of PP Clamp Saddle 50mm X 3/4" complete all as specified and directed by Engineer-in-Charge. Make- Elitech/Astore/Rainson
Supply, Installation, Testing & commissioning of 1/2" Spray Pop Up and features an encased plastic 'cage' to provide unmatched resistant to grit, two-piece ratchet mechanism, features is precision controlled flush at pop-down clears debris from unit, constructed of time-proven UV resistant plastic complete all as specified and directed by Engineer-in-Charge. Make: Rain Bird / Hunter
Supply, Installation, Testing & commissioning of 1/2" Spray Pop Up connecting swing joint assembly. The tubing shall be made of polyetylene having wall thickness of 2.3mm ,a working pressure of 5.5 kg/cm2 at 43oC and a surge pressure of 16.6 kg/cm2. The fittings shall be made of UV resistant thermo plastic. SA Series complete all as specified and directed by Engineer-in-Charge. Make : Rain Bird /Harit
Supply, Installation, Testing & commissioning of PP Clamp saddlee 50/40mm X 1/2" complete all as specified and directed by Engineer-in-Charge. Make: Elitech/Astore/Rainson
Supply, Installation, Testing & commissioning of flexible,16mm Inline drip line tubing, resistance to UV damage, algae growth in colour with flow rate , pressure rating 0.58 to 4.1 bar wall thickness 1.2mm complete all as specified and directed by Engineer-in-Charge. Make: Netafim/Rivulis/Godavari
Supply, Installation, Testing & commissioning ,Fixing & commissioning of openwell pumpset of having 5 HP 3 Phase complete all as specified and directed by Engineer-in-Charge. Make AquaTec/Texmo
Supply, Installation, Testing & commissioning of 4 Sq mm 4 Core copper Cable ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply, Installation, Testing & commissioning of 1.5 Sq mm 2 core Copper cable ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply, Installation, Testing & commissioning ,Fixing & commissioning of panel suitable for pumpset having outdoor type panel box and fixed alongwith following accessories starter ,start / stop push buttons , Ammeter, Voltmeter , Indicating lamps, MCB , with cable, auto manual relay etc. item complete all as specified and directed by Engineer-in-Charge. Make - BCH/L&T
Supply, Installation, Testing & commissioning of PVC Ball Valves 40 mm complete all as specified and directed by Engineer-in-Charge. Make Harit/Astore/Ashirvad
Supply, Installation, Testing & commissioning of PVC Ball Valves 50 mm complete all as specified and directed by Engineer-in-Charge. Make Harit/Astore/Ashirvad
Supply, Installation, Testing & commissioning of Air Release Valve 40 mm complete all as specified and directed by Engineer-in-Charge. Make: Automat/Harit
Supply, Installation, Testing & commissioning of Screen Filter 3" (30m³/hr) complete all as specified and directed by Engineer-in-Charge. Make: Automat/Harit
Supply, Installation, Testing & commissioning of Disc Filter 3" (30m³/hr) complete all as specified and directed by Engineer-in-Charge. Make: Automat/Harit
Supply, Installation, Testing & commissioning of 10" Rectangular valve box with cover complete all as specified and directed by Engineer-in-Charge. Make - Rain Bird
Supply, Installation, Testing & commissioning of brass quick coupling valve size 3/4" made up of solid brass with locking cover corrosion resistant and stainless steel spring including service saddle and riser assembly complete all as specified and directed by Engineer-in-Charge.
Supply, Installation, Testing & commissioning of brass Key with swivel elbow size 3/4" threads into top of QCV to provide water access complete all as specified and directed by Engineer-in-Charge.
Supply, Installation, Testing & commissioning of PP Clamp saddle 63 mm X 3/4" complete all as specified and directed by Engineer-in-Charge. Make: Elitech/Astore/Rainson
Supply, Installation, Testing & commissioning of 6" Round valve box with cover complete all as specified and directed by Engineer-in-Charge. Make : Rain Bird
Supply, Installation, Testing & commissioning of Pressure Relief valve 2" with accessories complete all as specified and directed by Engineer-in-Charge. Make: Harit/Automat
Supply, Installation, Testing & commissioning of MS with powder coated filter support for filter complete all as specified and directed by Engineer-in-Charge. Make - Arya steel
Supply of Water Level Sensor complete all as specified and directed by Engineer-in-Charge. Make - Harit /Automat
Supply, Installation, Testing & commissioning powder coated enclosure box for automation controller complete all as specified and directed by Engineer-in-Charge. Make - Arya Steel
Supply, Installation, Testing & Commissioning conduit pipe for cable ducting 25 mm complete all as specified and directed by Engineer-in-Charge. Make - PolyPack or Equivalent
Supply, Installation, Testing & commissioning Pump for RO water puming to storage tank complete all as specified and directed by Engineer-in-Charge. Make - Aquatec/Texmo
Supply, Installation, testing and Commissioning pressure pump with pressure switch complete all as specified and directed by Engineer-in-Charge.
Supply, install and commissioning Semi automatic jar washing machine 3 phase, 415 volt, 1 HP motor(Havells/CG) and 2 Nos 1 HP pump(CRI/Lubi) with nozzles SS-304(02 Nos) with high qaulity nylon brush(07 Nos), inner tank SS-304 and outer body structure 40x40 square pipe and push button ON/OFF including all contacts parts in SS-304 complete cutting/connecting with existing pipe/input water pipe line connection upto machine and machine drain pipe line conection complete all as specified and directed by Engineer-in-Charge. Make - Amishi Engg
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushing neat cement slurry with 3.00 Kg of cement per sq m complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (un-reinforced) in ground floor and in paving not exceeding 15 cm thickness ( below or above ground level) complete all as specified and directed by Engineer-in-Charge.
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge.
Demolition brick work or stone/boulder masonary,built in cement mortar or cement lime mortar including all quions, arches pillars,etc but ashlar facing dressed stone work and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
Taking down chowkat or frames not exe 1.50 sq.m each (with shutter without taking off shutter from the frame) etc complete all as specified and directed by Engineer-in-Charge.
Taking down chowket or frame with shutter (without taking of shutter from frame) exc 1.5 sqm but not exe 4.00 Sq m each each complete all as specified and directed by Engineer-in-Charge.
Taking down shutter of any description not exc 1.00 sqm each as in window & ventilator etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 97 here in before but exc 1.0 sqm but not exc 2.00 sqm each complete all as specified and directed by Engineer-in-Charge.
Haking out old broken glass (any thickness size quality or description) from wooden frames or stone,concrete or brick surrounds glazed with putty or fixed with beeds complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster, any description, on brick or stone walls etc, including raking out joints, hacking for key, scrubbing down with water etc and disposal of debris complete all as specified and directed by Engineer-in-Charge.
Dismantling False ceiling boards (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete (1:4:8) type D-2 using 40m graded stone agg as in foundation, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L M-25 using 20mm graded stone aggregate in foundations, footing, plinth beams, columns and slab, (reinforcement to be measured separately) complete all as specified and directed by Engineer-in-Charge.
S&F Pre- painted galvalume aluminum zinc coating GI base corrugated steel sheet 0.50mmthick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall ,fixed with self tapping screws as specified and directed by Engineer-in-Charge.
Form work to sides of concrete fdns, footings, bases of columns, raft and raft beams, sides and soffits of fdn and plinth beams and similar works complete all as specified and directed by Engineer-in-Charge.
Form work to sides of pillers, columns, struts, parts etc complete all as specified and directed by Engineer-in-Charge.
Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with dips icl, anchoring and welding at places as directed quilety conforming to IS complete all as specified and directed by Engineer-in-Charge.
As per item No 110 above but 6mm dia and over upto incl 10mm dia in stirrups, spacers and binders complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
M & L PCC 1:2:4 type B-1 using 20mm graeded stone aggregates as in floor 40mm thick finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L 100mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregates in sub base complete all as specified and directed by Engineer-in-Charge.
S&F Armstrong/instrulla mineral fibre acoustical ceiling panels of 16 mm thick RH 99 dune (Tegular) over in true in horizontal level false ceiling grid of XL 24mm system manufactured by M/S Armstrong works industries Ltd using hot dipped steel section exposed surface chemically cleaned caping pre-finished in baked polyster paint, wall angle of size 3000X19X19mm used in periphery of the ceiling fixed to wall partition /RCC column / band walls with the help of screws at 600mm C/C , main runner of size3000X24X32mm suspended at 1200mm C/C by using 2mm dia , GI wire hanger securely fixed to the structural soffit of slab by using 6mm anchor fastener at every 1200mm (max) and 1200mm long cross tee of size 24X27mm to be interlocked between in main runner at 600mm long cross tee of size 24X27mm fixed in between 1200mm long cross tee to forming a grid of 600X600mm complete all as per manufacturers specification & complete all as specified and directed by Engineer-in-Charge.
M&L for Epoxy treatment for bonding new or old Brick /concrete surfaces with applying chemical fosroc and Nitto Bond AR complete all as specified and as per manufacturers instructions & complete all as specified and directed by Engineer-in-Charge.
S & F Continuous (piano) hinges, brass, bright finish or electrogalvanise with width 30 mm complete all as specified and directed by Engineer-in-Charge.
S & F Rolled Steel sections confirming to Fe 410 - W qlty A as in main and cross beams, hip and jack rafters; purlins where connected to common rafters fixed with angle cleats or other connecting plates complete all as specified and directed by Engineer-in-Charge.
S&F Vitrified ceramic tiles 10 mm thick of light shade (Square/rectangular) polished area of each tile not exceeding 0. 36 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match over 15 mm thick screed bed or bedding layers in CM 1:6 complete all as specified and directed.
All as per item No 119 above but light shade as in skirting on vartical surface over 10 mm thickbacking coat in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for Non skid ceramic coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match incl screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM (1:4) complete all as specified and directed by Engineer-in-Charge.
M&L for Glazed ceramic coloured tiles 300x450x 7mm thick on vertical surfaces of wall set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 10mm thick rendering in CM (1:4) backing of wall tiles such as dado/skirting in vertical surface complete all as specified and directed by Engineer-in-Charge.
M&L for 18 to 20 mm thick Granite (of any type) work (table rubbed and polished ) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) incl pointing in white cement (1:2) using marble dust with admixture of pigment ot match with shade of granite including 15mm thick screed bed in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick cement concrete type C-2 1:3:6 using 40mm graded aggregate as in plinth protection, varamdah or path including necessary formwork & dummy joints complete all as specified and directed by Engineer-in-Charge.
M&L for brickwork with sub class B bricks straight or curved on plan to any radius in half brick thick wall built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces with WPC @ of 3% of weight of cement complete all as specified and as directed by the Engineer-in-Charge.
M & L for rendering 15mm thick in cement plaster 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement or cement complete all as specified and as directed by the Engineer-in-Charge
M&L, Rendering 5 mm thick on fair faces of brick or concrete surfaces with in CM 1:3 on ceilling finished even and smooth all as specified & as directed by Engineer-in-Charge
Supply only Integral waterproofing complete all as specified and directed by Engineer-in-Charge.
M&L for preparing newly plastered surfaces of walls and applying two coats of cement base paint complete all as specified and directed by Engineer-in-Charge.
M & L for preparing new surfaces of walls, distempering 2 coats with oil emulsion distemper white or tinted over one coat of wall care putty complete all as specified and as directed by the Engineer-in-Charge
All as per item No 131 above but on ceiling surfaces complete all as specified and directed by Engineer-in-Charge.
Complete removal of existing treatment including preparation of surfaces and applying two coats of weather proof emulsion of electric blue or white colour over a coat of exterior wall primer in (projections of column/wall/edges of chajja, roofs and other narrow locations in buildings upto ground plus three floor) complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment on walls including preparing old plaster surfaces and applying two coats of cement based paint complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment on walls including preparing old plastered surfaces and applying two coats of oil bound distemper complete all as specified and directed by Engineer-in-Charge.
All as per item No 135 above but on ceiling surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for two coat of Synthetic enamel paint over a coat of pink primer on new wooden surfaces of any description not other wise described over 10 cm width or girth including preparation complete all as specified and directed by Engineer-in-Charge.
Preparation of old painted surfaces and applying one coat of synthetic enamel paint on wooden surfaces of any description not other wise described over 10 cm width or grith etc complete all as specified and directed by Engineer-in-Charge.
M&L for prepartion of old painted surface of steel & iron work of any description not specifically mentioned otherwise over 10 cm width or girth & applying one coat of synthetic enamal paint complete all as specified and directed by Engineer-in-Charge.
M&L for prepartion on new surface of steel & iron work of any description not specifically mentioned otherwise over 10 cm width or girth & applying two coat of synthetic enamal paint over one coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
M&L PCC type B1, 1:2:4, using 20mm graded aggregate as in stagging for water tanks, inserting hold fast and filling Jamb etc and like including weathering slighly rounded or chamfered and where connecting slab and parapets etc angles throating complete all as specified and directed by Engineer-in-Charge.
M&L in repair for guniting work to RCC work in columns, beams, chajjas, Balconies, soffit of slabs, landings, RCC perapet wall and similar work by removing loose concrete, cleaning of surface with wire brush and applying one coat of epoxy paint to rusted Reinforcement and including S&F welded wire mesh fabric or wire not less than 95x95x3mm, adhesive plaster grade of concrete admixture non providing guniting pressure 2.00/2.50kgs/sqm with admixture part of cement and 3025 part of sand with a thickness of 50mm average and making the surface even and smooth including all necessary form work and applying 5mm cement plaster in CM 1:3 complete all as specified and directed by Engineer-in-Charge.
Formwork to rough fininised surfaces of chullah hoods, chajjas, troughs and similar items in- cluding edges complete all as specified and directed by Engineer-in-Charge.
Rebaring of reinforcement bar 8mm to 12mm dia upto depth of 200mm and complete all as specified and directed by Engineer-in-Charge.
Taking down carefully existing bitumen tar felt including plaster, concrete/brick coba /tiling from the roof /parapets till RCC slab and roughening the surface ,wire brushing , cleaning and washing with water etc. , and removing the rubbish to a distance exceeding 500m but n.exc 1Km & depositing where complete all as specified and directed by Engineer-in-Charge. .
Material and labour for grouting in roof through PVC nipples at a spacing of 45 to 60cm C/C including drilling injection points to a depth of 75-100mm, providing 10mm dia PVC nipples and pressure grouting using with and including cement mixed with plasticizing admixture of cement to fill up all capillaries/ voids/ honeycombing areas inside concrete with pressure of 2 to 4 Kg/Sqcm and continued till refusal. After grouting, nozzles to be sealed with the sealing compound/mortar etc, all as per manufacturers instructions complete all as specified and directed by Engineer-in-Charge. Note:- After ascertaining the location of leakage/ seepage/dampness under item No.2 here-in-before, this item shall be operated at the required location.
Material and labour for roof treatment on RCC roof slab complete as mentioned below, complete all as specified and directed by Engineer-in-Charge. (i) Cleaning the concrete surfaces of RCC roof slab as obtained after demolition/taking down of existing water proofing treatment thoroughly with wire brushes, washed and dried. (ii) Checking the roof slab by flooding test with water till total elimination of leakage/seepage/ dampness all as specified in SSR Part-I (after ascertaining location of leakage/seepage/ dampness, carrying out treatment vide item No. 9 hereinafter of pressure grouting shall be operated at the required locations). (iii) Brushing surface with neat cement slurry at the rate of 3.00kg of cement per Sqm. (vi) Cleaning the plastered roof surfaces and applying a coat of bitumen primer @ 0.3 kg/sqm on top of dry surface. (v) Laying APP modified polymeric membrane 3mm thick with non woven polyester core laid and bonded to the sub-strata and over-laps shall be sealed/fused by flame "torch', application method all as per manufacturer's instructions.
S&F PVC door frame 50x47x5mm thick reinforced MS square tube including 25x6mm MS holdfast etc complete all as specified and directed by Engineer-in-Charge.
S&F 30mm thick (styles) factory made solid panel PVC door shutters consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width tuck inside with solvent cement for styles & plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the styles & rails with suitable PVC sheet beading and joined together with solvent cement and fixing in the frame at site all as shown on drawing on page 146 of SSR Part-II 2004 including taking down the old PVC door shutters complete all as specified and directed by Engineer-in-Charge.
Mild steel framed work such as angles, grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; door frame, ladders and similar work conforming to Fe 290 Gde-E-165 complete all as specified and directed by Engineer-in-Charge.
S&F 30mm thick flush door shutter solid core construction with block board case and plywood face panels, commercial type on both sides complete all as specified and directed by Engineer-in-Charge.
S & F 4 mm thick Figured glass, pin headed type and glazing with oil putty in squares not exceeding 0.5 Sq. M in each pane complete all as specified and directed by Engineer-in-Charge.
S&F 35mm thick glazed and skelton shutter of 1st class hardwood open rebated and prepared to receive glass, gauze divided into square with plain ,chamfered or rounded, mitred and rebated sash bars, any number, edges of framing plain or rounded , fitted with cut and mitred beads for securing glasses etc size of members of shutters as specified in SSR Part-I, section 8, clause 8.20(a) supplied and fixed to chowkhat complete all as specified and directed by Engineer in Charge
S&F pressed steel frame for doors with one or more rebated including necessary fixing lungs, hinges, lock, strike plates etc complete all as specified and size of frame 125 x60 mm complete all as specified and directed by Engineer-in-Charge.
S&F in repairs powder coated Anodised aluminium frame for doors, windows ( min thickness 50 microns) with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engineer-in-Charge.
S&F Of Powder coated Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified and directed by Engineer-in-Charge.
S&F 200 mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed by Engineer-in-Charge.
S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) complete all as specified and directed by Engineer-in-Charge.
S&F 150 mm long, extruded aluminium alloy handles, fabricated type anodised complete all as specified and directed by Engineer-in-Charge.
S&F 100 mm cold rolled mild steel butt hinges heavy weight complete all as specified and directed by Engineer-in-Charge.
S & F floor door stopper of brass body and tongue, anodised, with hard drawn steel spring, fixed in floor, Overall length of cover plate 150mm complete all as specified and as directed by the Engineer-in-Charge
S&F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed in wooden/steel/Aluminium windows, or Stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
S&F in repair Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed in wooden/steel/ Aluminium windows, or Stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
S&F sheet glass ordinary quality 3mm thick quality with oil putty or beads fixed with screws in sequence not exceeding 0.5 sqm in each pane complete all as specified and directed by Engineer-in-Charge.
M&L for 18/19 mm thick Block boards, grade 2 quality, interior grade, decorative type with decorative face veneer on one face, Ditto fixed in repair for copboard shutter, shelve, partiion & kitchen cabinet complete all as specified and directed by Engineer-in-Charge.
Dismantling water tanks 250 to 500 ltrs capacity. complete all as specified and directed by Engineer-in-Charge.
S&F Rotational molded polyethylene water storage tanks 3 layered, ISI marked (cylindrical vertical with threaded lid) hoisted and fixed in position all as specified in SSR Part-I of Capacity 500 litres with GI Tank Nipple inlet and outlet 20mm complete all as specified and directed by Engineer-in-Charge.
S&F Ball valve, high pressure with of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe or fixed of size 20 mm bore, fixed in repairs.(Min Wt 20mm- 210 gms) complete all as specified and directed by Engineer-in-Charge.
S&F in repair Gun metal globe or gate valves high pressure with polythene float and fly nut complete screwed for iron pipe or for unions of 20 mm bore and fixed in repairs, complete all as specified and directed by Engineer-in-Charge.
S&F Harrison curtain rails, 19/20mm dia, anodised aluminium alloy with fixing brackets, stops, rollers etc including taking down old one complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing with connections for cleaning for refixing complete of bore 15mm, complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing with connections for cleaning for refixing complete of bore 20mm, complete all as specified and directed by Engineer-in-Charge.
S&F 15mm bore steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings complete all as specified and directed by Engineer-in-Charge.
S&F 20 mm bore steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings complete all as specified and directed by Engineer-in-Charge.
Cutting chases for concealed water tubing or concealed conduitwiring, etc. and making good, cutting exceeding 10cm girth in CM 1:3 complete all as specified and directed by Engineer-in-Charge.
S&F in repair Bib taps, long body, fancy type, chromium plated with crutch or butterfly handle screwed down for iron pipe or for brass ferrule and fixed for bore of pipe 15 mm, fixed in repair, complete all as specified and directed by Engineer-in-Charge.
S&F in repair Brass chromium plated shower rose 125mm with CP Arm with swivel joints incl fixing to steel pipe or union complete complete all as specified and directed by Engineer-in-Charge.
S&F in repair Stop valves fancy type, chromium plated with long shank and cup (concealed type) for iron pipe or for unions of bore dia 15mm and fixed, complete all as specified and directed by Engineer-in-Charge.
S&F in repair Vitreous china squatting pan of Orissa Pattern size 580x 440 mm white with ‘P’ or ‘S’ trap , front or back inlet but excluding flushing cistern and flush pipe fixed in repair including placing in position in floor and embedded in cushion of PCC 1:7:12 type E-1 using brick bats and finishing the top surfaces to match with the existing flooring complete all as specified and directed by Engineer-in-Charge.
S&F in repair vitreous china wash basin, Vitreous China (flat back or angle back type) any size, including cutting for and pinning in ends of bracket or erecting stand fixing of waste pipe etc complete all as specified and directed by Engineer-in-Charge.
S & F in repairs Sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 915 mm x 460 complete all as specified and directed by Engineer-in-Charge.
S&F in Repair PVC waste pipe suitable for 32mm dia waste coupling complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC connections 15 mm size with PTMT nuts of length 450 mm long complete all as specified and directed by Engineer-in-Charge.
S&F in repair Angle cock, chromium plated screwed down, high pressure, screwed both ends for iron pipe or for unions bore dia of 15mm complete all as specified and directed by Engineer-in-Charge.
S&F 15mm dia pillar taps, cast cast copper alloy with capstan heads, chromium plated, fency type screwed down high pressure, with or with out lettered hot or cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repair Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed by Engineer-in-Charge.
S&F in repair Sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with mild steel chromium plated bracket guard and railing 60cm long complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC (Plastic polymer Cistern) valve less, Symphonic action type, flushing cistern of capacity 10 liters, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete including taking down by dismantling the existing unserviceable cistern of any description complete all as specified and directed by Engineer-in-Charge.
S&F in repair Waste coupling, 32mm dia, of PTMT (half or full threaded) .(Minimum weight 32mm-45gms/40mm-60 gms) complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) floor trap, plain with CP grating including jointing with solvent cement, 75mm diameter of outlet, complete all as specified and directed by Engineer-in-Charge.
Taking down rainwater pipes/PVC pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by Engineer-in-Charge.
S&F PVC(SWR) pipes, 110 mm external dia double socketed in any length with rubber joints, fixed to walls with PVC brackets/clamps complete all as specified and directed by Engineer-in-Charge.
S&F PVC(SWR) pipes, 75 mm external dia double socketed in any length with rubber joints, fixed to walls with PVC brackets/clips complete all as specified and directed by Engineer-in-Charge.
S&F PVC(SWR) bends suitable for 110 mm external dia complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) junction single, (Single T) equal or unequal of 110mm dia with access door complete all as specified and directed by Engineer-in-Charge.
S&F PVC(SWR) bends suitable for 75 mm external dia complete all as specified and directed by Engineer-in-Charge.
S&F PVC(SWR) bends suitable for 75 mm external dia with acces door complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) vent cowl of 75mm bore dia complete all as specified and directed by Engineer-in-Charge.
M&L in repair 75mm bore dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
M&L in repair 110mm bore dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
M&L 15mm thick screed bed or bedding layer of cement mortar 1:4, for laying floor finish, complete all as specified and directed by Engineer-in-Charge.
M&L fibrillated fiber reinforced heavy duty coloured cement concrete pre polished chequred tiles from Ultra floor tiles or equivalent size 300 x 300 x 20 to 25 mm and wt 4.2kg/tile set jointed and pointed in neat cement slurry in floors, and cut and polished with white cement & pigment complete all as specified and directed by Engineer-in-Charge.
M&L for providing precast cement louvres and jallies, 25 mm thick, type B0 1:2:4 (Using 12.5 mm graded aggregate), set in cement mortar 1:4, (Measured solid), including all mouldings but excluding frame, complete all as specified and directed by Engineer-in-Charge. (Note : necessary demolition of jallies is included)
M&L for chain link fence, chain-link fence should be woven fence made of galvanized steel wire. The wires should run vertically and are bent into a zig-zag pattern so that each "zig" hooks with the wire immediately on one side and each "zag" with the wire immediately on the other. The wire mesh should be woven in shuch a way that it should form diamond shape. The size of mesh should be 2-2.5 inches. chain link fencing should be made of 4 mm gauge.chain link fencing should be 7 feet high. Fixing of fence should include of Line Post,Top Rail , End Post Cap , Rail Ends cap, Tension Bands,Tie Wire ,Chain Link Fence Posts , Tension Wire, End Post ,tension Bar ,Top Rail Sleeve ,Gates come pre-assembled. ,Gate Post Hinge to mount to the post,Gate Frame Hinge to mount to the gate. Brace Bands to hold the rail ends and mount above the tension band complete all as specified and directed by Engineer-in-Charge.
S & F Mild steel work in hand rails, wind ties, posts and struts in fencing and gate screwed or welded to shape as directed, including all necessary drilling, bolting or riveting etc., and similar work confirming to Fe 410 - O or Fe 310 - O complete all as specified and directed by Engineer-in-Charge.
M&L for Kerb stone Ornamental type semi circle on top size 500 x 225 x 100mm thickness from M-30 plain cement concrete and maximum depression from a straight edge held against the finished surfaces shall not exceed 15 mm jointed in cement mortar 1:6 and struck flush complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushioning under floors as in foundations including watering and consolidation, complete all as specified and directed by Engineer-in-Charge.
M&L for machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment confirming to SI 15658-2006 of 60 mm thickness M-35 Grade, over 25 mm thick leveled sand cusining etc complete all as specified and directed by Engineer-in-Charge. (Sand shall be measured and paid seperetly )
Removing building material etc, (other than spoil payable under items 03028 to 03031 in Section 3-Eathwork) to a distance of 2.5 km or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination (for per load refer SSR 2010 section 21 page 462) complete all as specified and directed by Engineer-in-Charge.
S.R. Constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .