| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹34.7 LAccepted-AOC | 1 | Accepted-AOC LOWEST RATE | |
| 2 | 2₹36.4 L+₹1.7 L (4.88%)Rejected-Finance | 2 | Rejected-Finance NOT LOWEST |
Tender Value
₹40.5 L
EMD Value
₹81,100
Closing Date
28 Sept 2022, 6:00 pmClosed
GE (AF) PALAM DELHI CANTT
GE (AF) PALAM DELHI CANTT
PROVN OF CERTAIN WORK SERVICES,PROVN OF MOORING POINTS AND PICKETING BLOCKS AND ADDN/ALLTN TO GARBAGE RECEPTACLE BINS AT AF STN PALAM UNDER GE (AF) PALAM, DELHI CANTT-10
2022_MES_548764_1
GENP-48/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (AF) PALAM DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) PALAM
₹81,100
Yes
24 Apr 2023
30 Aug 2022
29 Sept 2022
30 Aug 2022
28 Sept 2022
15 Sept 2022
Amount
Demolition of brickwork or stone/ boulder masonry, built in cement or cement lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and directed as directed by Engr-in- Charge.
M&L for brick work with subclass 'B, brick, straight or curved on plain exceeding 6 m mean radius built in cement mortar 1:6 complete .
M&L for 10 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces including finishing surface even and smooth without using extra cement on walls complete all as specified .
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer using rollers complete.
M&L for struck, keyed, raised or recessed pointing on brick wall surface in cement mortar 1:4 complete all as specified and directed by Engr-in- charge.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc. 15cm thick above or below ground level including removal of debris from site to outside of Mod Land.
M & L for 75 mm thick cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in floor etc complete.
M&L for factory made machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and pigment complete all as specified and directed.
M&L sand layer under floor of interlocking paver block including watering and consolidation.
M&L for cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in roof kerbs or mud stops, rounded or chamfered on edges etc complete.
M&L for 75 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in plinth protection including finishing surface even and fair with out using extra cement and making necessary joints filled with bitumenous mastic complete.
Dismantling mild steel sheeting of any gauge, thickness and type including Nainital or similar pattern roof coverings, complete all as specified and directed by Engineer-in-charge.
S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified
S&F for rolled mild steel as Joist, channel, angle, or tee sections,fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated)
M&L for wire netting of galvanised steel wire 4.0 mm dia and size of mesh 25mm with 40X40X6mm MS angle frame fixed to wall etc complete all as specified and directed
S&F 1 mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete.
S&F for rolled mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framedguard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe -290 Gde-E-165 complete all as specified and directed.
Taking down cement plaster on brick or concrete wall surfaces etc including raking out joints, hacking for key , scrubbing down with water etc.
Dismentling boarding of any description, fixed in any position with nails complete.
M&L for 15 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even and smooth surface without using extra cement on wall complete.
M&L for 5 mm thick cement plater in cement mortar 1:3 in ceiling finished even & smooth surface without using extra cement complete all as spcified.
M&L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth surface without using extra cement on wall complete.
M&L for two coats of plastic emlusion paint over a coat of primer including including prepairation of newly plastered surface of walls complete all as specified and directed.
M&L for preparation of newly plastered or unplastered surface of ceiling and applying two coats of white wash all as specified.
Supply only integral water proofing compound ISI marked.
Dismantling of floor, hearth or wall tilling including cement mortar bedding (but not backing) and removing the debris from site to outside MoD land .
M&L for vitrified tiles 10 mm thick of first quilaty (Square/rectuangular) polished, double charge shade, area of each tiles exceeding 0.36 Sqm but not exc. 0.42 sqm laid in floors etc set and jointed with neat cement slurry and pointed in white or coloured cement to match the tile over and including 15mm thick screed bed in cement mortar 1:6 all as specified.
All as per item No 28 above but as in skirting.
M&L for non skid joint free coloured ceramic tiles 7mm to 8mm thick (squre or rectangular) area of each tile excedding 0.11sqm but n.exc. 0.18sqm as in floors etc. set and jointed in grey cement and pointed in white or colour cement to match the surfaces over & including 15mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.
M&L for glazed ceramic tiles in vertical surface such as dado,skirting,walls etc of size 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & including 10mm thick rendering in cement mortar 1:4 all as specified.
Dismantling wall and ceiling boards ( fibre , pulp,insulation etc.) or insulation boards / slabs / blankets , any thickness including fillets all as specified
M & L for provding false ceiling of 15mm thick fine fissure board sharped finished mineral fiber accountic false ceiling tiles with back of the duly sanded and finshed with a coat of protective paint and front duly finished false system of size (600x600) mm having noise reduction co-efficient of 0.55 light reflection of 80% thermal conductivity k=0.057 W/WWC and humidity resistance of 95% fixed to true look PVC die KL -24 suspension system (Hot dipped aglvanised steel section) of exposed T Section consisting of perimeter wall angle of size (24x24) mm of thickness 0.45 of mm c/c universal main runner of T Shape with double rotary siticing of size (38x25) mm of lenght 1200mm made from 0.33GS steel of lenght 3.60 mtr to be spced at 600x 600mm size) c/c cro runner T shape wtih double rotary siticing of size (30x24)mm of length 1200mm made 0.25 thick GS sheet spaced @ 600mm c/c (600mm 600mm) size complete all as specified and directed by Engineer -in- Charge.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for all as specified and as directed by Engr-in-Charge.
M&L for 100mm thick cement concrete 1: 2:4,type B-2 (using 40mm graded crushed stone aggregate) as in floor including finishing surface even and smooth without using extra cement complete all as specified .
S&F wash hand basin, Vitreous China, flat back 550mmx400mm size, white including PVC waste coupling 32mm size, PVC waste pipe 32mm bore, pair of brackets of mild steel angle 35 x 35 x 6mm size including one CP pillar tap, cast copper alloy 15mm bore, one brass stop valve 15mm bore and one PVC connection15mm size with PTMT nuts of length 450mm long complete all as specified and directed by Engineer-in-Charge.
S&F for Vitreous China Urinal pot white including partition, waist pipe screw with wall fixing complete, Make:Hindware Cat Part No: 61001 or equivalent in Parryware/Cera as approved by GE.
Supply & fixing for Vitreous China EWC Super constellation including cistern of size 83x37x66 Cm with 'S' or 'P' trap as aer Cat Part No 20040 (S-10/P-9) (Make Hind ware or equvallent in Parry ware
M&L for 100mm dia Cast iron floor / Nahani trap with grating including jointing and breaking/ dismantling any type of floor and making good cement concrete type B-1 (1:2:4) and testing complete all as specified.
S&F brass chromium plated tubular towel rail, 20mm dia, 'D' type, 60cm long between flanges complete all as specified and directed.
M&L for 15 mm bore GI tubing medium grade with all fittings and fixed to walls and ceilings or laid in floors etc complete all as specified and directed by Engineer-in-Charge.
M&L for 20 mm bore GI tubing medium grade with all fittings and fixed to walls and ceilings or laid in floors etc complete all as specified and directed by Engineer-in-Charge.
S & F 15mm dia bib tap with wall flange, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle , screwed down , screwed for iron pipe or for brass ferrule complete.
Supply and fxing for 75mm bore cast iron soil,waste and vent pipe in any length with or without ears fixed to walls including suitable clamps after every one mtr of interval with cement joints fixed to wall complete all as specified and directed.
S & F CI bend (any radius ), diminishing pieces or tapers of 75 mm bore fitted with oval access door complete all as specified.
S&F for 110 mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls including suitable clamps after every one meter of interval complete all as specified.
S&F PVC(SWR) bends any radius, 110 mm bore complete
S&F 15mm dia angle cock,cromium plated, screwed down, high pressure, with crutch or butterfly handles, screwed both ends for iron pipe or for unions and fixed all specified .
Supply and sixing PVC connections 15mm size with PTMT nuts of length 450mm and fixed all as specified and as directed.
S&F CP Soap dish of Make-AKP-35731P of Jaquar or its equivalent in kohler/ZIM complete all as specified and directed.
S&F Rotational moulded polythlyene water storage tanks (cylindrical vertical with close top) of capacity 500 ltrs,three layers, hoisted and fixed in position all as secified
S&F 20mm dia ball brass valve high pressure with pollythene float and fly nut complete
Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, wall panelling etc and making good cutting not exc 10 cm girth in brick work complete .
M&L for reinforced cement concrete 1:.5:3,type A-1using 20mm graded stone aggregate as in slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the including form work complete all as specified.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoping for columns hooking ends and binding with and including mild steel wire not less than 0.9mm dia or securing with clips complete .
M&L for TMT bars 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hoping for columns hooking ends and binding with and including mild steel wire not less than 0.9mm dia or securing with clips complete all as specified and directed.
Material and Labour for 18 to 20mm thick polished granite stone slab fixed on floor/platform over and including 15 mm thick cement screed bed in cement mortar 1:4 with neat cement slurry and jointed with coloured cement to match complete all as specified and directed by Engineer-in-Charge.
S&F Mild steel powder coated 20 mm dia curtain rod including brackets and end knobs / fineals complete all as spcified..
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size not exceeding 1.50 Sqm each including cutting holes in walls of appropriate size for insertion of cement concrete blocks for hold fasts complete all as specified.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size exceeding 1.50 Sqm but n. exc 4.0sqm each including cutting holes in walls of appropriate size for insertion of cement concrete blocks for hold fasts complete all as specified.
S&F anodised aluminium powder coated frame for door, windows, ventilators, partition wall etc with one or more rebates including joining cleat for fixing etc complete all as specified and as directed
S&F anodised aluminium powder coated (minimum thickness of powder coating 50 micron) door shutter, aluminium section weight 0.55 Kg/m including neccesary joining cleats, glazing clips,rubber neoprene packing, handle 2 Nos in each door, hinges, anodised aluminium snap beading screw etc. complete all as specified.
S&F anodised aluminium powder coated (minimum thickness of powder coating 50 micron) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised, handle 2 Nos in each window aluminium fittings such as peg stays150mm long (1 No). hinges type B-21, 100mm long (2 Nos) handle 100mm (1No.) complete all as specified.
S&F aluminum grill of design and parttern as approved including aluminium beading complete.
M&L for 12mm thick prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination & fixed with screws to timber frame complete
S & F door closure hydraulically regulated designation No 3 universal type suitable for door shutter of 851 to 1000 mm in width of Aluminum body (die cast) weight between 61 to 80 kg.
S & F double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminum alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other party made of mild steel heavy duty complete.
S & F brass Mortice lock,vertical type, size 100 mm 4 levers
S&F aluminium tower bolt of extruded section of 150mm size complete all as specified.
S&F aluminium door stopper double legged with rubber shoe 75mm long fixed to door shutters complete.
Material and labour for prepartion of plastered or unplastered old deorated surfaces by brooming down or steel wire brushing scraping down smoke, soot , mould moss efforescent salt & trading oil and grease spots and filling cracks/holes with wall care putty and applying two coats of oil bound distemper on walls all as specified and directed by Engr in charge,
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth or not exceeding 10 Sqm on plan and not exceeding 1.50 m in depth for manholes ,well ,sewer lin etc and getting out in soft/loose soil.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm.
Removing excavated soil to a distance exceeding 50m but not exceeding 200m and depositing where directed at a level not exceeding 1.50m above the starting point .
Material and Labour for concrete bed to 150 mm bore drain pipes in cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregates including packing under and haunching against the sides of pipes after they are laid and tested.
Material and Labour for 150 mm internal dia reinforced cement concrete pipes drain pipes class NP-2 laid in trenches and jointed complete all as specified..
Excavation over areas n.exc.1.5m deep and getting out in any type of soil.
M&L for PCC 1:4:8 type D-2(40mm stone graded agregate) in foundation, filling and mass concrete as in sub base complete.
M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius built in cement mortar 1:4 with WPC all as specified and directed by Engr-in-Charge. (NOTE : WPC shall be measured and paid separately).
M&L for cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in surface channels and drains including necessary form work.
M&L for RCC precast manhole covers with plain faces using mix 1:2:4 type B-1 using 20mm graded stone aggregate and set in CM 1:4 complete
M&L for PQC/RCC Core Cutting of 152mm dia and depth up to 200mm ( mooring point ) and providing 20mm Mild steel-U shape bar including installation, drilling, gruoting/filling with use of material RE-500V4 HILTI including tool use with core cutting drill 25mm & 16mm machine to be use for the cutting of RCC footing to furnish the cutting pieces, dismentling with HILTI Machine and removing excavated material from the site to outside of MoD land complete .
S&F framed work as in picketing,doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete with Fe-410-W (Gde E-250 quility A ) including drilling, welding complete all as directed by Engr-in-Charge.
M&L for preparation of newly steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete.
M & L for Point wiring with single core PVC insulated but unsheathed 1.5 Sqmm FRLSH multistranded copper conductor cable 1100 volts grade IS-694 marked drawn in and including rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked with all conduit fittings and fixing accessories including modular metal flush box with modullar plate for mounting switches, sockets, fan regulators, etc and earth wire single core PVC insulated but unsheathed multistrand copper conductor cable 1100 volts grade IS-694 marked 1.5 Sqmm FRLSH cable as continuous earth wire connecting to common earth dolly in concealed wiring system including making good the disturbed surface of wall for one light point controlled by one switch one way all as specified and directed by Engr- in- Charge.
All as per item No 87 above but for one fan/exhaust fan point controlled by one switch.
All as per item No 87 above but for one socket outlet 5 Amp controlled by one switch on independent board
All as per item No 87 above but for one 3 pin 5Amps socket out let point on the same board controlled by one switch complete
All as per item No 87 above but for but for one power point 6 pin 15 Amps socket out let with 2.5 Sq mm stranded copper conductor cable PVC insulated including earth wire 2.5 Sq mm copper conductor cable connected to earth dolly complete.
All as per item No 87 above but for one power point 6 pin 15 Amps socket out let with 4.0 Sq mm stranded copper conductor cable PVC insulated including earth wire 4 Sq mm copper conductor cable connected to earth dolly complete all as specified and directed by Engr-in-Charge.
S&F for Modular switch 1 way 6 Amps one module all as specified.
S&F for modular socket 6 Amps 2/3 Pin combined 02 module complete.
S&F for modular switch one way 16 Amps, one module complete.
S & F for socket modular type 6 amp/16 amps, 2/3 pin combined 02 Module complete.
Supply and fixing for ceiling rose, surface type, 65mm x 50mm, 2 to 3 terminal complete.
S&F for Indoor decorative LED battens- integrated type 20 watt 4 feet white fixture with extruded aluminium body, suitable for LED tube 20 watt , bipin holder, connector block, LED rod 20 watt etc complete with all accessories internally are wired and including connecting up with twin core copper conductor cable complete .
Supply and fixing sheet metal enclosure for distribution board SPN (when MCBs to be used ) 8 way double door, 200 Amps rated bus bars and with neutral, earthing bar and din rail complete .
Supply and fixing MCB, SPN, 40A ,10KA .
Supply and fixing MCB, SP, 6-32A ,10KA.
Supply and fixing MCB, SP 40 Amp ,10KA .
S & F of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB single pole 20 Amps complete.
M&L for sub main wiring with 2 run of 6 Sqmm single core PVC insulated but unsheathed FRLSH cable of specified size multistranded copper conductor 1100 V grade IS-694 drawing into and including rigid non metallic PVC conduit, medium grade ISI marked ( not less than 25 mm) with all conduit fittings & fixing accessories for concealed in wall/ ceiling or surface including one run of 6 sqmm earth continuity conductor of similar type of cable complete (Note- The undermentioned runs of single core cable and specified earth continuity conductor and revelent conduit with fitting acessories will be measured as one run).
All as per item No 104 above but 2 runs of 4.0 sqmm and 1 run of 4.0 sqmm earth wire.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, check nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) with fair finish, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of 22 gauge, 8 mesh per liner inch, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No. 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge.
S&F exhaust fan metallic body 300 mm sweep 230 volts, single phase , AC supply complete with nuts, bolts and washers size of the bolts 06 inch long 6mm dia embedded in the wall including suitable hole for fixing of exhaust complete all as specified and direted by Engr-in-Charge.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-Charge.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW , BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc of capacity 25 litres all as specified and directed by Engr-in-Charge.
M/S Parshant Associates
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .