Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.4 LAccepted-AOC OPP GATE NO 02 PO NORTH BENGAL UNIVERSITY | DARJEELING | DARJEELING | WEST BENGAL | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹47.4 L+₹1.8 L (3.95%)Rejected-Finance SAHEBPARA RAOD UPPER BAGDOGRA P O BAGDOGRA DISTRICT DARJEELING WEST BENGAL PIN 734014 | BAGDOGRA | DARJEELING | WEST BENGAL | 734014 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹47.9 L+₹2.3 L (5.04%)Rejected-Finance MAJUMDER COLONY BURDWAN ROAD SILIGURI DIST DARJEELING WB PIN 734 014 | DARJEELING | WEST BENGAL | 734014 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹48.8 L+₹3.2 L (7.10%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹50.6 L+₹5.0 L (10.9%)Rejected-Finance | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
9 Dec 2022, 6:00 pmClosed
GE BENGDUBI
Bengdubi Military Station, PO-Bengdubi, Dist-Darjeeling, Pin 734424
MAINTENANCE REPLACEMENT OF OLD UNSERVICEABLE MCCB PANELS ACSR CONDUCTORS CABLES FOR OTM UNDER AGE E M OF GE BENGDUBI MIL STN
2022_MES_563244_1
8401/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE BENGDUBI
MES Enlisted/ Un-enlisted contractor of E and above category b(i) i.e. Low Tension Electric Works(upto 1100 Volts)
8 documents required · 8 mandatory
₹500
Yes
GE BENGDUBI
₹90,000
Yes
27 Jan 2023
15 Nov 2022
12 Dec 2022
15 Nov 2022
9 Dec 2022
3 Dec 2022
16 Nov 2022 - 21 Nov 2022
Amount
Dismantling of ACSR or AAC condutor from LT service feeder or distribution line complete all as specified and directed.
Taking out old/Unsv damaged existing steel/concrete poles of any size/length from existing position including necessary earthwork like excavation,returning filling,removal of earth etc and demolition of PCC foundation and removing the same from site complete all as specified and directed.
Dismantling cross arms of MS channels or angle sections etc complete complete all as specified and directed.
Dismantling insulators any type any sizes complete all as specified and directed.
Supply,erecting and fixing in proper position steel tabular electric pole swaged type 410 SP-31 (9 meter long) complete with CI base plate, final taper plug bolts nuts screw and pole cap and including two coat of aluminium paint over a coat of red oxide primer including preparing the surface complete all as specified and directed.
S&F in replacement digital Ammeter 3 phase LED display class 1 for measuring alternating current of range : 0 - 200 A flush type complete all as specified and directed.
S&F in replacement digital Voltmeter for measuring alternating current voltage of range 0-500 V flush type 96x96MM size complete all as specified and directed.
S&F in replacement LED indicator - R/Y/B/G 240 V AC complete all as specified and directed.
M&L for repairs to LT panel outdoor/indoor type including taking out old damaged / unserviceable door hinges and welding new hinges of size as per existing and providing one locking arrangement complete all as specified and directed.
M&L for preparation for old rusted steel surface of feeder pillar box/LT panel of any size ,applying one coat of synthetic enamel paint as per the existing pattern above the PCC and black paint on legs of feeder pillar/LT panel and cutting vegetation growth all around and on the feeder pillar box/panel board upto 1 mtr apart from feeder pillar all around complete all as specified and directed.
M&L for earthing complete of advance encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology upgrated (Zinic & alloy coated) Zinic coated (80-100) microns with pure (99.9%) & alloy coating (200-250) microns earthing system confirming IS-3034 the outer and inner pipe should be 76.2mm & 41.9mm dia 2 mtr length zinic coated with additional special alloy coating 300mm on the topside for additional protection of the terminal the annular space between the pipes being filled up with compact fill(CF) (Crystalline conductive compound) the compact fill (CF) mixture which is machine pressed in the pipes should not disintgrate or collapse when outer pipe corrods, the inner pipe should be extended with terminals for connectivity. The job includes digging the pits and refilling the same by electrode/conductolite back fill compound (Ground enhancer) the BFC should dbe eco friendly it should not contain environmentally hazard materials having ROHS certification from NABL accredited lab. The earth pit should be provided with a FRP earth pitcover for protection and safe guard of terminals. In area where soil condition is bad good earth is to be arranged to fill the excavated pits by mixing the same with BFC 4 bags (as per soil condition) extra perpit/unit. As earth electrode is the main component of the earthing system which is indirect contact with the ground and thus provides ameans of releasing or collecting earth leakage current. The materials should have a good electrical conductivity & anti corrosion properrty in wide range of soil condition complete and testing on completion including dismantling unserviceable earthing complete all as specified and directed. Make:- ASHLOK/JMV/True power
M&L for earthing complete of advance encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology upgrated (Zinic & alloy coated) Zinic coated (80-100) microns with pure (99.9%) & alloy coating (200-250) microns earthing system confirming IS-3034 the outer and inner pipe should be 76.2mm & 41.9mm dia 3 mtr length zinic coated with additional special alloy coating 300mm on the top side for additional protection of the terminal the annular space between the pipes being filled up with compact fill (CF) (Crystalline conductive compound) the compact fill (CF) mixture which is machine pressed in the pipes should not disintgrate or collapse when outer pipe corrods, the inner pipe should be extended with terminals for connectivity. The job includes digging the pits and refilling the same by electrode/conductolite back fill compound (Ground enhancer) the BFC should dbe eco friendly it should not contain environmentally hazard materials having ROHS certification from NABL accredited lab. The earth pit should be provided with a FRP earth pitcover for protection and safe guard of terminals. In area where soil condition is bad good earth is to be arranged to fill the excavated pits by mixing the same with BFC 4 bags (as per soil condition) extra perpit/unit. As earth electrode is the main component of the earthing system which is indirect contact with the ground and thus provides ameans of releasing or collecting earth leakage current. The materials should have a good electrical conductivity & anti corrosion properrty in wide range of soil condition complete and testing on completion including dismantling unserviceable earthing complete all as specified and directed. Make:- ASHLOK/JMV/True power
S&F in repairs MCCB 100 Amps 4 pole, 415 V, breaking capacity 16 KA,Ics=100% ICU including spreader terminals & connected accessories complete all as specified and directed. Make:- Legrand / ABB / L&T/Scneider/C&S
S&F in repairs MCCB 160 Amps, 4 Pole, 415 V, adjustable type, with breaking capacity 25 KA, Ics=100 % ICU including spreader terminals & connected accessories complete all as specified and directed. Make:- Legrand / ABB / L&T /Scneider/C&S
S&F in repairs MCCB 200 Amps, 4 Pole, 415 V, adjustable type, with breaking capacity 25KA,Ics=100 % ICU including spreader terminals & connected accessories complete all as specified & directed. Make:- Legrand / ABB / L&T /Scneider/C&S
S&F in repairs MCCB 250 Amps, 4 Pole, 415 V, Adjustable type, with breaking capacity 25 KA, 100 % ICU including spreader terminals & connected accessories complete as specified & directed. Make:- Legrand / ABB /L&T/Scneider/C&S
S&F in repairs MCCB 320 Amps, 4 Pole, 415 V, adjustable type, with breaking capacity 36 KA, Ics=100% ICU including spreader terminals & connected accessories complete all as specified & directed. Make:- Legrand / ABB / L&T/Scneider /C&S
S&F in repairs MCCB 400 Amps, 4 Pole, 415 V, adjustable type, with breaking capacity 36 KA, 100% ICU including spreader terminals & connected accessories complete all as specified & directed. Make:- Legrand / ABB / L&T /Scneider/C&S
S&F in repairs MCB 63 Amps, 4 Pole, 415 V, adjustable type, with breaking capacity 10 KA, 100% ICU including spreader terminals & connected accessories complete all as specified & directed. Make:- Legrand / ABB / L&T /Scneider/C&S
S&F in repairs on load changeover with handle in enclosure 100 Amps, 4 Pole, 415 V, AC, 50 Hz complete all as specified & directed. Make :- Legrand/L&T / ABB /Havells /C&S
S&F in repairs on load changeover with handle in enclosure 200 Amps, 4 Pole, 415 V, AC, 50 Hz complete all as specified & directed. Make :- Legrand/L&T / ABB /Havells /C&S
S&F in repairs on load changeover with handle 200 Amps, 4 Pole, 415 V, AC, 50 Hz complete all as specified & directed. Make :- Legrand/L&T / ABB /Havells /C&S
S&F in repairs on load changeover with handle 400 Amps, 4 Pole, 415 V, AC, 50 Hz complete all as specified & directed. Make :- Legrand/L&T / ABB /Havells /C&S
Supply and fixing in repair 3 phase and neutral, 415 volts outdoor type Bus bar chamber 100 Amps, TPN, 4 way, 415 V, AC, 50 Hz, confirming to IP 43, CPRI approved, factory fabricated & factroy assembled , waterproof,dust and vermin proof cubical type with locking arrangement , LT panel made out of suitable size angle iron, channel and fabricated from 3.15 mm thick ( minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032) and indicating lamps with & including busbars made of pure copper duly insulated with heat retardant fire proof (HRFR) heat shrinkable sleeves of relevant colours bus bar shall be properly supported/mounted on epoxy insulators. All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for cable gland and lugs for incoming and out going cable. Suitable openable doors shall be provided of all operational busbar provided on all other accessories. Grouting the pillar box in ground with & including suitable size foundation & plinth of PCC 1:3:6(type C-1 using 20 mm grade stone aggregate) complete.Panal shall be manufactured suitable for housing and including the following duly control wiring with multi stranded copper condutor FRLS with colour coding complete for 3 phase 50 Hz electric supply complete all as specified & directed.
All as per items No 25 here-in-before but 200 Amps, TPN, 4 way 415 Volt, AC, 50 Hz complete all as specified and directed.
All as per items No 25 here-in-before but 400 Amps, TPN, 4way, 415 V, AC, 50 Hz complete all as specified & directed.
M&L for cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in lean concrete in foundation of poles, filling and mass concrete , stay assembly, etc, including formwork( as / if required) complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in coping of poles, including formwork ( as / if required) complete all as specified and directed.
Excavation in trenches in any type of soil and not exc 1.5 m wide and n.exc 1.5 m in depth for laying of cable and fixing poles, stays etc and getting out in soft/loose soil complete all as specified and directed.
Add to item 30 for each additional 1.5m or part thereof in depth beyond the first 1.5 m complete all as specified and directed.
Returning,filling in including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick with excavated soil complete all as specified and directed.
Removing excavated material (surplus soil) to a distance not exceeding 50 mtrs and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
M&L clean dry sand in trenches/ ducts for cushioning to cable 8cm below the cable and 15cm above the cable and compacted thickness 18cm complete all as specified and as directed.
Supply & laying Sub-Class old size B bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection complete all as specified and directed.
Relaying of old serviceable brick as in cable protection complete all as specified and directed.
Taking out old unserviceable under ground cable of any size, any position forn trenches, floors and wall and serviceable cable for reuse complete all as specified and directed. Note:- Earth work,shall be measured and paid separetly under respective item of this schedule.
Relaying of serviceable cable retrieved from srl item No-37 here-in-above after detecting the fault and making straight through jointing kit of LT 440 volt under ground system of LT feeder/location of size 6 Sqmm 2 core to 16 Sqmm 2 core complete all as specified and directed. Note:-Necessary excavation,returning filling and removal of soil shall be measured and paid separately under respective item of this schedule.
Relaying of serviceable cable retrieved from srl item No-37 here-in-above after detecting the fault and making straight through jointing kit of LT 440 volt under ground system of LT feeder/location of size 16 Sqmm 4 core to 70 Sqmm 3.5core complete all as specified and directed. Note:-Necessary excavation,returning filling and removal of soil shall be measured and paid separately under respective item of this schedule.
Relaying of serviceable cable retrieved from srl item No-37 here-in-above after detecting the fault and making straight through jointing kit of LT 440 volt under ground system of LT feeder/location of size 95 Sqmm 3.5 core to 200 sqmm 3.5 core complete all as specified and directed. Note:-Necessary excavation,returning filling and removal of soil shall be measured and paid separately under respective item of this schedule.
Supply and laying insulated, armoured, heavy duty electric cables with aluminium conductor 1100 volts, cross sectional area 6 sqmm 2 core laid in trenches/ through pipes/ducts or on pole/wall/floor jointing to OH conductor, LT panels, main switch with cables size aluminium lugs and testing complete all as specified and directed. Note:- Earth work,shall be measured and paid separetly under respective item of this schedule.
All as per items No 41 here-in-before but 10 Sqmm 2 Core
All as per items No 41 here-in-before but 16 Sqmm 2 Core
All as per items No 41 here-in-before but 16 Sqmm 4 core
All as per items No 41 here-in-before but 25 Sqmm 3.5 core
All as per items No 41 here-in-before but 35 Sqmm 3.5 Core
All as per items No 41 here-in-before but 50 Sqmm 3.5 core
All as per items No 41 here-in-before but 70 Sqmm 3.5 core
All as per items No 41 here-in-before but 95 Sqmm 3.5 core
All as per items No 41 here-in-before but 120 Sqmm 3.5 core
All as per items No 41 here-in-before but 150 Sqmm 3.5 core
M&L for surface dressing averaging 15cm depth in soft/loose soil for cleaning and cutting /removal of green vegetation in and around the installations and removal of the soil outside of the installation including spreading thin layer of anti vegetation chemical to prevent abnormal growth of grass/bushes complete all as specified and directed.
Cutting and trimming of tree branches of any grith all around the LT over head lines upto 2 mtr from all around the over head lines complete and removing the cut branches from the site to a distances not exc 50 mtr complete all as sprcified and directed.
M&L for MS steel work (structure) as in cross arms breacing of MS channel or angle sections of required size and shape including clamps, D clamps, eye hooks, back plate with bolts, nuts and washers, drilling holes for bolts, insulator etc and welding to make rail to rest the cables in the existing ducts including priming coat with red oxide primer and two coat of aluminum paint complete all as specified & directed.
S&F LT line polyproplene composite phase separators 2 line (bolted type) at suitable spans conforming to IS 1445 complete all as directed and specified.
S&F LT line polyproplene composite phase separators 3 line (bolted type) at suitable spans conforming to IS 1445 complete all as directed and specified.
M&L for painting of LT steel tubular pole (9/11 mtr long) any type or size externally above foundation including all MS work with one coats of aluminium paint after scrapping / clearing well the existing surface complete all as directed and specified. Note:-The above work includes painting of 3 Nos black & 02 nos yellow bands width 30 cm by fluorescent paint in alternate layers upto 1.5 mtr height above foundation / plinth block)
M&L for painting of 9 m PCC pole with cement wash two coat by using the cement and two coat of aluminium paint over cross arms, clamp of any length and shape for LT overhead line including preparation of the existing surface including marking pole numbers in a 15 cm dia yellow circle & marking three black & two yellow bends width 30 cm by fluorescent paint, from bottom of pole to 1.5 Mtr height complete all as specified and directed.
M&L for repairs to main electrical panel at sub stations by tightning all loose connections of the cable ends & replacing the damaged/US/burnt aluminium lugs of required sizes, insulating/secure the weak insulated portin of cable ends inside the panel by taping with good quality of insulation tape, clean the dust by air blower complete all as specified and directed.
M&L for stringing, ACSR conductor of required size for O/H lines, on LT poles, including binding wire, including taking down old ACSR conductor complete all as specified & directed.
Restringing of each OH conductor with to permissible sag rebinding to insulators with new wire where cut point jumpers to be higher size of the OH conductor complete all as specified & directed.
Horizontal boring using ultra sound technique/any other suitable mechanical means at approx 1 metre below the road, pavement, hardstanding etc without damaging the existing surfaces getting out & disposal of soil to a distance not exceeding 50 metre from the site of work complete all as specified and directed.
S&F in repair/replacement of energy saving, environmental friendly, long life, pressure die-cast aluminium housing with IP66 protection flood light with high power LEDs as light source connecting and testing LED flood lights of 200 watts capacity fixed on high mast/ street light pole complete all as specified and directed. Make:- Havells/Crompton/C&S
All as per item No. 68 here-in-before but of 120 W capacity LED Flood light
All as per item No. 68 here-in-before but of 50/60 W capacity LED Flood light
S&F in repair GI pipe 50 mm light grade including fittings to poles/laid under road for protection of under ground cable including making good in disturb surfaces and sound condition complete all as specified and as directed.
S&F junction box made of thermoplastic of size 205mm x 255mm x 112mm consisting of 4 Nos terminal on porceline support inside enclosure with MCB SP 6 Amps and using 40 x 6mm size MS clamps of required shape & size with bolts, nuts & washers and making connection by providing suitable size of lugs / binding and testing directed complete all as specified and directed. Make : Hensel or equivalent
M&L for load distribution of LT panels/feeder pillar box and building panel upto transformer phase balance, including insulation tap lugs etc if required for load distribution complete all as specifed and directed.
Dismantling of old unserviceable stay assembly including stay wire complete with necessary demolition of concrete excavation and earth work as required and removing the same from site complete all as specified and directed.
S&F stay assembly complete with all accessories and stay clamps all as shown in electrical plate No 1 of SSR Part I with using stay rod of 20mm dia and insulator etc. complete all as specified and directed. Note:-Excavation and earth work shall be measured and paid seperately under relevant item.
M&L for 3 core cable 1.5 sqmm FRLSH PVC insulated copper conductor weather proof in existing surface/ recessed/on pole complete all as specified and directed.
M&L for PVC conduit pipe medium grade 20mm dia (ISI Marked) including necessary clamps, nuts, bolts etc. as required complete all as specified and directed.
M&L in repair steel wire rope 6 mm dia (7/19 construction) for high mast upto 30mtr height including necessary repair required for replace of stainless steel wire rope as required complete all as specified and directed.
Supply, jointing and testing straight through cable jointing kit (Heat shrinkable type) for 1100 volt grade cable complete with and including jointing materials and including accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 6sqmm 2 core to 16sqmm 2 core and including provision of aluminium thimbles complete all as specified and directed. Make: Denson / M Seal / Reychem
All as per items No 79 here-in-before but 25 to 50 Sqmm 3.5 Core
All as per items No 79 here-in-before but 70 to 150 Sqmm 3.5 Core
All as per items No 79 here-in-before but 185 to 250 Sqmm 3.5 Core
Supply, jointing and testing straight through cable jointing kit (Heat shrinkable type) for 1100 volt grade cable complete with and including jointing materials and including accessories suitable for 4.0 core XLPE armoured aluminium conductor cable of size 16sqmm 4 core including provision of aluminium thimbles complete all as specified and directed. Make: Denson / M Seal / Reychem
S&F in repair danger notice plate of 1.6mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for 25x20 cm size complete all as specified and directed.
S&F in repair earth continuity conductor GI strip 25x4mm size complete all as specified and directed.
S&F in repair earth continuity conductor GI strip 32x6mm size complete all as specified and directed.
S&F in repair GI pipe 80mm light grade including fittings to poles/ laid under road for protection of under ground cable including making good the disturb surfaces and sound condition complete all as specified and directed.
Schedule of Credit refere srl page No 38 & 39 of Tender
M/S G D CONSTRUCTION
M/S P. RAI CHOUDHURY AND CO.
GURUNG CONSTRUCTION
PRADIP KUMAR BOSE
M/S KAR CONSTRUCTION
M/S DUTTA CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .