Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.0 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED DUE TO LOWEST | |
| 2 | L2₹52.0 L+₹5.5 L (11.8%)Rejected-AOC SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L2 | Rejected-AOC REJECTED DUE TO NOT LOWEST | |
| 3 | Rejected-Technical 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | - | Rejected-Technical Residual work in hand is more than twice the tendering limit. | |
| 4 | Rejected-Technical MAHAMUNI PARA BOGAFA P S P O SANTIRBAZAR SOUTH TRIPURA | GOMATI | TRIPURA | 799125 | - | Rejected-Technical Firm did not upload requisite documents of one class below firm as per Note 1 of Appx A to NIT on Pg No 10 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
1 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) LOHEGAON
GE (AF) LOHEGAON, PUNE -411032
MAINTENANCE, REPAIR AND REPLACEMENT OF DEFECTIVE ITEMS OF LT DISTRIBUTION SYSTEM IN OMQ, NP AREA, TECH AREA AND WSA AT 2 WG AT AF STN PUNE
2021_MES_443160_2
8441/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) LOHEGAON
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (AF) LOHEGAON
₹90,000
Yes
19 Aug 2021
17 Jun 2021
3 Jul 2021
17 Jun 2021
1 Jul 2021
19 Jun 2021
60 days
Amount
Disconnecting of incoming / outgoing ACSR conductor/ cables and GI earthing wire and dismantling of existing unserviceable LT pole any size / type and removing unserviceable LT pole from the PCC foundation in necessary earth work complete all as specified and directed.
Dismantling cross-arms of M.S. channel or angle sections, clamps, nut bolts etc. complete all as specified and directed.
Dismantling / taking out insulator of any size / type from existing electric LT lines complete all as specified and directed.
Dismantling of existing stay assembly any type / size from its stay rod, cutting stay rods (above ground portion) dismantling MS clamps, nuts, bolts, stay bow, loop insulators, stay wire etc complete all as specified and directed.
Dismantling / taking out existing ACSR conductor any size from existing over head lines incl disconnection complete all as specified and directed.
Disconnecting of incoming / outgoing cables and earthing lead and taking out existing unserviceable outdoor feeder pillar box / Panel and removing unserviceable pillar box / Panel with frame from the PCC foundation complete all as specified and directed.
Taking down Old unserviceable LT UG cable of service connection or distribution system of any size and removing from site complete all as specified and directed. ( Excavation and earth work will be measured seperately)
Refixing of serviceable cross arms, channel or angle sections obtained under above item No. 2 including painting of cross arms with two coats of synthetic enamel paint complete all as specified including necessary welding complete all as specified and directed.
Material and labour for painting to existing steel tubular poles 7/9/11 mtr long including cross arms,looping box,GI pipe bracket,clamps etc. with one coat of aluminium paint including preparation of surfaces and feeder name and pole number with zebra type painting upto 6 feet from bottom with alternate patch of size 1 foot of white and light blue colour paint complete all as specified and directed.
Material & Labour for painting to feeder pillar box / LT panel & duct cover etc, including angle iron frame with two coat of grey synthetic enamel paint including welding of door with proper size new hinges of suitable size and locking arrangements where required complete all as specified and directed.
Supply & fix line separator suitable for LT OH line of 3 phase and neutral conductor complete all as specified and directed.
Ditto all as per Ser Item No.12.00 above but single phase and neutral conductor complete all as specified and directed.
Felling/trimming of trees not exc 30 cm girth including cutting of upper portion of branches and disposal of same at a distance not exc 50 mtr and clearing of site complete all as specified and directed. (Note:Tools/ladder required for cutting/trimming of trees will be provided by the contractor at no extra cost and cost of the same be deemed to be included in the quoted rate.) Note:Each Span will be measured from one pole to another pole
Removing LT over head conductor from insulator where ever required and restretching the same without any kink / bend upto premissible sag, binding it on insulator by means of binding wire including fixing line seprator at 3 places where required and directed and testing LT over head line on completion complete all as specified and directed. Note:- 1.Three runs of LT over head conductor for phase, one run of LT over head conductor for neutral shall be measured & paid as one length. 2.Line seprator shall be measured and paid seperately.
Provn of services for cable fault location for LT UG cable, XLPE insulated 1100 Volts, of any size with fault detector machine complete all as specified and as directed.
Material and labour for straight through jointing kits heat shrinkable type LT UG XLPE cable heavy duty armoured sheathed including excavation in any strata, taking out cable, and making disturbed surface after relaying the cable making joints suitable for aluminium conductor of size given below complete all as specified and directed.
25 to 50 sqmm 3.5 core
70 to 120 sqmm 3.5 core
150 to 185 sqmm 3.5 core
240 to 300 sqmm 3.5 core
Supply and fix GI Pipe Light grade with all connected accessories of sizes 100 mm complete all as specified and directed.
Supply and fix GI Pipe Light grade with all connected accessories of sizes 80 mm complete all as specified and directed.
Supplying and erecting ( in true vertical position) steel tubular swaged poles complete with cast iron base plate final taper plug, bolts nuts and screws all as specified of type 410-SP-31 (9.0 mtr length) complete all as specifed in IS 2713 (part-II) 1980 including one coat or red oxide primer and two coats of aluminium paint to exposed surfaces and with blach bituminous paint for embedded portion of pole complete all as specified and directed.
Material and labour for cross arms, bracing supports, clamps and back plates fabricated from structural steel sections, including nut bolts, washer welding bending cold/ hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one premer coat of red oxide primer, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
Material and labour for replacement of old broken ACSR with aluminium conductor steel reinforced streching without kinks / bends and binding with insulators on street poles complete all as specified and directed.
M&L for stay assembly complete with accessories as shown in electrical plate No.1 of SSR part-I 1991 using stay rod of 20mm dia stay plate 6mm thick complete all as specified and directed. Note :- Loop type insulator, stay clamps excavation and earthwork and PCC shall be measured and paid separately respective item of this schedule.
S&F shackle type insulator vitreous procelain white / brown / green with and including galvanised mild steel straps, washer insulator, bolts and nuts, insulator of size 100mm height and 115 mm max dia with working pressure 1100 volt and galvanised steel straps 3 to 5 mm size and suitable size nut and bolts complete all as specified and directed.
M&L for providing pin type procelain white / brown / green / insulator including galvanised mild steel spindle, two galvanised iron. Washer and one galvanised iron nut, 100mm height 65 mm dia for 1100 volts grade complete all as specified and directed.
M& L for danger notice plate 1.6 mm thick mild steel sheet vitreous enamelled white with letter figures and conventional skull and tongue in signal red colour and fixed with MS clamps bolts nuts of approved size LT, 20x15cm complete all as specified and directed.
M&L for cement concrete (1:4:8) type D2 in foundation filling and mass concrete using 40mm graded stone aggregate for pole/stay foundation etc complete all as specified and directed.
M&L for cement concrete (1:3:6) type C2 in foundation filling and mass concrete using 40mm graded stone agg for pole/stay foundation etc complete all as specified and directed.
M&L for cement concrete (1:2:4) type B1 in foundation filling and mass concrete and coping of poles incl necessary form work using 20 mm graded stone aggregate etc complete all as specified and directed.
Supplying, spreading & leveling stone aggregate size of 20 mm grade to the existing sub station complete all as specified and directed.
Supplying ,Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified and directed for following size:-
16 sqmm 4 core
25 sqmm 3.5 core
35 sqmm 3.5 core
50 sqmm 3.5 core
70 sqmm 3.5 core
95 sqmm 3.5 core
120 sqmm 3.5 core
150 sqmm 3.5 core
185 sqmm 3.5 core
240 sqmm 3.5 core
300 sqmm 3.5 core
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole etc. complete all as specified and directed.
Soft/loose soil
Hard/dense soil
Soft/disintegrated rock
Returning/ Refilling of excavated soil including spreading levelling and well ramming in layers for any type of soil complete all as specified and directed.
Removing the surplus spoil to a distance not exceeding 50 mtrs from the starting point and depositing at a height not exceeding 1.5 m above ground level complete all as specified and directed.
Material and labour for stone dust sand cushioning to under ground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable complete all as specified and directed. [Note : Measuremenet will be done after punning]
M&L for brick protection covers laid over cables of sub class'B' bricks old size (230X115X75) mm complete all as specified and directed.
Supply and fix in repair / replacement of MCCB FP 630 Amps Adjustable type with breaking capacity 50 KA including connections and testing for proper functioning complete all as specified and directed.
Supply and fix in repair / replacement of MCCB FP 400 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning complete all as specified and directed.
Supply and fix in repair / replacement of MCCB FP 250 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning complete all as specified and directed.
Supply and fix in repair / replacement of MCCB FP 200 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning complete all as specified and directed.
Supply and fix in repair / replacement of MCCB FP 160 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning complete all as specified and directed.
Supply and fix in repair / replacement of MCCB TP 200 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning complete all as specified and directed.
Supply and fix in repair / replacement of MCCB TP 160 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning complete all as specified and directed.
Supply and fix in repair / replacement of MCCB TP 100 Amps Fixed type with breaking capacity 16 KA including connections and testing for proper functioning complete all as specified and directed.
Supply and fix in repair / replacement of MCCB TP 63 Amps Fixed type with breaking capacity 16 KA including connections and testing for proper functioning complete all as specified and directed.
Supply and fix in repair / replacement of digital Volt meter (0-500) including connections and testing for proper functioning complete all as specified and directed.
Supply and fix in repair / replacement of digital ammeter including connections and testing for proper functioning complete all as specified and directed.
Supply and fix in repair / replacement of Indicating Lamp R. Y. B (LED) Type including connections and testing for proper functioning complete all as specified and directed.
Supply and fix in repair / replacement of CTs of ratio 100/5 including connections and testing for proper functioning complete all as specified and directed.
Supply, Install, Test and Commissioning of LT feeder pillar box outdoor type fabricated out of 3.0 mm thick CRCA sheet double door(front & back opening), CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following:- (a)Aluminium bus bar 400 Amp (R Y B & N) with coloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set. (b) MCCB FP 160 Amps 35 KA - 01 No for main in coming (c) MCCB 63 Amps 3P, 10 KA - 03 Nos (d) LED indicator for RYB of size 22.5 mm - Set of 3 (e) 3 Phase Digital voltmeter -01 nos (f) 3 Phase Digital ammeter-01 Nos Note: All MCCBs must conforms Fixed thermal and fixed thermal magnetic setting and Ics= 100% of Icu For Officers Qtrs, MAP qtrs and Geyer ss
Supply, Install, Test and Commissioning of LT feeder pillar box of size 1200x1200x400 mm outdoor type fabricated out of 3.0 mm thick CRCA sheet double door(front & back opening), CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following:- (a) Aluminium bus bar 400 Amp (R Y B & N) with coloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set. (a) MCCB FP 250 Amps 35 KA - 01 Nos for Main incoming (b) MCCB 3P 125 Amps 25 KA - 04 Nos (outgoings) (c) LED indicator for RYB of size 22.5 mm - Set of 3 (d) 3 Phase Digital voltmeter -01 nos (e) 3 Phase Digital ammeter-01 Nos Note: All MCCBs must conforms Fixed thermal and fixed thermal magnetic setting and Ics= 100% of Icu JUNCTION PANEL
Supply, Install, Test and Commissioning of LT bus bar panel of size 600x600x300 mm outdoor type fabricated out of 3.0 mm thick CRCA sheet double door(front & back opening), CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following:- (a)Aluminium bus bar 400 Amp (RYB & N )with coloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set.
Material and labour for shifting of LT panel of size2500 x 2500x 400mm consisting of 800 Amps ACB as main incoming and 12 Nos Outgoings of different capacity and changeover switch from PS-I Tech area to LDP lab substation. LT Panel to be properly mounted on MS frame of minimun size of 50x50x6mm duly grouted in the ground using suitable PCC mixture and connection of existing LT cables into the panel using lugs and glands and commisioning and testing of panel on full load complete all as specified and directed. Note:- (a) Dismantling and taking out of old unserviceable LT panel will be measured and paid seperately (b) Quoted Rate must include the service cost of carriage truck/crane to be used in shifting of panel
Material and labour for shifting of LT panel of size 2500 x 2500x 400mm consisting of 800 Amps ACB as main incoming and 12 Nos Outgoings of different capacity and changeover switch from PS-II Tech area to ATC substation. LT Panel to be properly mounted on MS frame of minimun size of 50x50x6mm duly grouted in the ground using suitable PCC mixture and connection of existing LT cables into the panel using lugs and glands and commisioning and testing of panel on full load complete all as specified and directed. Note:- (a) Dismantling and taking out of old unserviceable LT panel will be measured and paid seperately (b) Quoted Rate must include the service cost of carriage truck/crane to be used in shifting of panel
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 25 X 4 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab cover 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade, including galvanised iron strip 25X4 mm with GI protection pipe of 40 mm medium grade up to 7.5 meter length, etc complete all as specified and directed.
S & F GI earth continuity conductor or main earthing lead of size 25x4 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. as required complete all as specified and directed.
Material and labour for Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out removing of grass and vegetation grown around the electrical installations like transformers, LT panels, 2 pole structure, HT panels and complete area inside the fencing complete all as specified and directed.
Material and labour of taking out of serviceable ACB of 800 amps from LT panel and refixing of same in new LT panel complete all as specified and directed. Note: ACB will be fixed in new LT panel taken under Item No.62.00
Supply, Install, Test and Commissioning of LT feeder pillar box outdoor type fabricated out of 3.0 mm thick CRCA sheet double door(front & back opening), CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following:- (a)Aluminium bus bar 400 Amp (R Y B & N) with coloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set. (a) MCCB FP 250 Amps 35 KA - 01 No for Main incoming (b) MCCB 100 Amps 3P, 35 KA - 03 Nos (Outgoing) (c) MCCB 63 Amps 3P, 10 KA - 02 Nos (d) LED indicator for RYB of size 22.5mm - 01 Set (e) 3 phase DIgital voltmeter -01 nos (f) 3 phase Digital ammeter-01 Nos Note: All MCCBs must conforms Fixed thermal and fixed thermal magnetic setting and Ics= 100% of Icu 2402 SQN
Supply, Install, Test and Commissioning of LT feeder pillar box outdoor type fabricated out of 3.0 mm thick CRCA sheet double door(front & back opening), of size 900x 900mm x 400mm CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following:- (a)Aluminium bus bar 600 Amp (R Y B & N) with coloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set. (a) MCCB FP 400 Amps 50 KA - 01 No for Main incoming (b) LED indicator for RYB of size 22.5 mm - 01 Set (c) 3 Phase DIgital voltmeter -01 nos (d) 3 Phase Digital ammeter-01 Nos Note: All MCCBs must conforms Fixed thermal and fixed thermal magnetic setting and Ics= 100% of Icu Bombdumb
Supply, Install, Test and Commissioning of LT feeder pillar box outdoor type fabricated out of 3.0 mm thick CRCA sheet double door(front & back opening), CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following:- (a)Aluminium bus bar 1000 Amp (R Y B & N) with coloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set. (a) Provn of space for fixing of 800 Amps 4 Pole ACB (ACB taking down under item no. 3.00 above will be fixed in this panel) - As main incoming (b) MCCB FP 400 Amps 50 KA - 02 Nos(outgoing) (c) MCCB 250 Amps 3P, 35 KA - 02 Nos (Outgoing) (d) MCCB 100 Amps 3P, 35 KA - 02 Nos (outgoing) (e) LED indicator for RYB of size 22.5mm - 01 Set (f) 3 phase DIgital voltmeter -01 nos (g) 3 phase Digital ammeter-01 Nos Note: All MCCBs must conforms Fixed thermal and fixed thermal magnetic setting and Ics= 100% of Icu Akash missile
Rama Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .