Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 CrAccepted-AOC | ₹2.5 Cr | L1 | Accepted-AOC OK |
| 2 | L2₹2.5 Cr+₹1.6 L (0.62%)Rejected-Finance PANIHAR CHOWK CHOUDHARYWAS HISAR RAJGHAR RD PANIHAR CHOWK CHOUDHARYWAS 125001 | HISAR | HISAR | HARYANA | 125001 | ₹2.5 Cr+₹1.6 L (0.62%) | L2 | Rejected-Finance Higher rate |
| 3 | L3₹2.6 Cr+₹5.7 L (2.26%)Rejected-Finance | ₹2.6 Cr+₹5.7 L (2.26%) | L3 | Rejected-Finance Higher rate |
| 4 | L4₹3.0 Cr+₹43.5 L (17.2%)Rejected-Finance 62 BALSAMAND ROAD HISAR 125001 | HISAR | HARYANA | 125001 | ₹3.0 Cr+₹43.5 L (17.2%) | L4 | Rejected-Finance Higher rate |
Tender Value
₹2.8 Cr
EMD Value
₹5.5 L
Closing Date
24 Feb 2024, 1:00 pmClosed
SANDEEP KUMAR
Executive Engineer, MICAD Division, Canal Colony, Binjhol, Panipat
Solar Powered Integrated Micro Irrigation Infrastructure O/L RD 40155/L New Urlana Minor including low pressure pipeline infrastructure from the outlet to Community Pond/On-farm ponds on Item Rate Mode
2024_HBC_355407_1
2024572280CA D925 4A00 82B5 AC491FDA5B831841CAD
Open Tender
Civil Works
Works
510 days
KURANA
As per BID Document
3 documents required · 3 mandatory
₹15,000
₹5.5 L
Yes
MICAD Division Panipat
7 Mar 2024
17 Feb 2024
24 Feb 2024
17 Feb 2024
24 Feb 2024
17 Feb 2024
21 Feb 2024
Amount
NS Item -Providing and fixing of three phase 50Hz ±3% rated motor, frequency 415V ± 3% rated motor voltage, with constant motor flux control, (Submersible motors shall conform to all the requirements of IS 9283) Solar A.C. Agricultural Pumps along with Universal Solar Pump Controller (USPC) all external part of motor used in open well submersible pump having casing of Alloy steel confirming to IS 3444 including all PVC insulated polymer sheathed 3 core flat type cabling in conduit, required from solar plant to solar pump through control room required to connect, including cost of and as per IS code 14220-2018 including third party inspection.Average discharge 13 LPS / Head 52 meter / minimum / minimum output rating of 15 KW. Duly installed on the suitable foundation. Actual pump set`s parameters will be finalized after approval of design and drawing. Solar Pumping Sets should be of the make: KSB / Shakti/ Kirloskar /CRI/Lubi/ Crompton/ WPIL, (NS Item) @ Rs 11002.53/- per HP Quantities are total sum of varrious pumps capacity in HP may varry as per design requirement for site. ((174708*1.12/20) plus (163063*1.12/15) plus (123310*1.12/12.5))/3( Rates approved in TAC,MICADA Haryana on 09.02.2022)
NS Item -Supply Installation testing commissioning of Solar Photovoltaic Stand alone Plant conforming to MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength. Including lightning and surge voltage protection, Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required, built in metering system to moniter plant performance (Amp-meter, Volt-meter, Frequency meter, Energy meter, Watt-meter, and other instrument/equipment as required) Note:- PV modules used must qualify to the latest edition of IEC PV module qualification test or equivalent BIS standards Mono Crystalline Silicon Solar Cell Modules IEC 61215/IS14286. In addition, the modules must conform to IEC 61730 Part-1- requirements for construction and Part 2 – requirements for testing, for safety qualification or quivalent IS and be mounted on fixed Aluminium/GI structure of adequate strength and design as per IEC/IS specification. Including field-based electro luminescence (EL) study be performed after receiving the modules at site and after installation. Module mounting structure (MMS) design and drawing shall be duly vetted from government institute Including third party inspection Actual parameters/capacity will be finalized after approval of design and drawing. ( Rates approved in TAC,MICADA Haryana meeting on 09.02.2022)
NS Item -Horizontal directional drilling with micro tunnelling methods, for pipe laying under pucca rasta /road crossing( Rates approved in TAC,MICADA Haryana meeting on 09.02.2022)
NS Item -Providing and fixing Tank Type (Make of Metal) Fertilizer and Chemical Injector System confirming to IS 14483 (Part 3) of 2018 for demonstration and guiding the farmers regarding fertilization and chemicalisation of system. (rates include ventury with manifold 1.0`=1300 and 60 liter fertilizer tank= 4400 ) Rates approved vide memo No.MICADA/2021/3068-70 dated 07.06.2021
NS Item -Hydrant assembly for Nakka in field, Rates including Tee, riser pipe, butterfly valve, Flange and labour for fixing butter fly valve should be as per IS 13095-2020 (Rates are as per analysis including HSR item 25.3.6)
NS Item -Providing, fixing,testing and commissioning of pressure gauge 2` dial with Glycerin filled to be fixed before and after filtration unit ( Rates approved in TAC,MICADA Haryana meeting on 09.02.2022)
NS Item -Providing fixing of Header Assembly/Manifold 3`(loose) Rates approved vide memo No.MICADA/2021/3068-70 dated 07.06.2021
NS Item -Supply and erection of alfa valve(Rate approved vide XEN,CAD Kurukshetra letter No. 2082/5A dt. 29.6.2018)(N.S. item)
NS Item -Preparation and implementation of warabandi of the complete chak and Identification of training needs of the farmers, preparation of training modules on various subjects concerning operation and maintenance of the MI systems, Solar array and pumping systems and cropping pattern etc., and providing necessary training to the farmers as per the identified needs. Necessary training shall be provided to the WUA members and the staff identified by the Engineer also for all activities involved in the O and M of the complete MI System including
NS Item -Construction of control room/regulation cum watch and ward hut as per approved design and drawing including water supply, Sanitary fittings, electric fittings, septic tank and other items as required etc (Roof covered area 20` X 20.75`) As per approved design and drawing
NS Item -Complete operation and watch and ward of the project 1 plus 3 year including operation of pump house, pipe line and accessories, electro mechanical solar plants complete in all respect.( Rates are in per ha per year)
NS Item -Supplying, assembling, lowering and fixing in vertical position 70% of total depth UPVC medium well casing (CM) pipe of 200 dia in bore well, with 30% of depth UPVC medium well screen (RMS) pipes with ribs conforming to IS: 12818] covered with ISI marked welded stainless steel screen (SS 304) cage Type V-Wire Wound Screens, in bore wells conforming to IS:8110 and compositions of material as per IS:1012 after boring/drilling bore well of 300 mm diameter by suitable method prescribed in IS: 2800 (part 1), including collecting samples from different strata, after lowering of casing pipe bore should be packed with| graded gravel in bore well of size as per IS 4097, casing pipe should be connected with horizontal- perforated pipe burried in bottom filter media (HSR Item No 33.8.3, 33.9.3, 33.6.1.1, 20.99)
NS Item -Providing and placing in horizontal layers filtering media screened washed and 20%- 0.2 to 0.4 mm effective size Fine sand screened cleaned and washed in top layer, 10%-Charcoal layer activated carbon in second layer, 25 and washed in third layer, 25%- 20 mm to 25 mm Bajri (coursed) 46 screened and washed in fourt layer and 20%- 50 mm to 75 mm Broken Cum stone, screened, washed in bottom after EW excavtion. Including suitable wall thick brick structure of suitable size to cover filter media HSR Item No 20.52.1, NS Item, 20.52.2,20.52.4, 20.52.5, 7.21.1, 6.1.4 and 11.5.3 mm to 6 mm Coursed sand screened cleaned
NS Item -Providing and fixing of 4x5` Iron sheet board welded with 2` dia iron pipe having height of 5 feet anchored in concrete block 6`x6`x1.5` in ground duly painted and writing the site details. NS Item
NS Item -Supply and Installation of valve regulated solar batteries as per IS 16270:2014 (reaffirmed 2019) have autonomy time of 15 days.
NS Item -Supply and carriage of HDPE 180mm dia end cap
NS Item -Galvanized steel chain link both end twisted fence fabric having opening size 7.5 x 7.5 cm and 3.15 mm dia wire, 2.2 meter height of mesh,with 2.8 meter ht of MS Angle 50 x 50 x 5 mm supports fixing at spacing of 3 meter centre to centre, supports with MS Flat 35 x 5 mm. Fencing supported with MS Angle 35 x 35 x 5 at top and bottom. The M.S Angle supports shall be anchored in cement concrete (1:3:6) blocks 45 x 45 x 60 cm additional razor barbed wire fencing shall be provided at the top of mesh, fencing including gate @Rs 2400/-per meter plus 15% Contractor profit and over head charges (N.S.ltem)
NS Item -Providing and fixing electromagnetic water flow meter in main line( downstream to PRV and upstream to NRV) confirming to ISO 4064 manufactured with PTFE material diameter of main pipeline ( 49851 plus 15%=57329)
NS Item -Providing, laying, aligning, and jointing with butt fusion welding techniques (IS 7634 (Part 2) : 2012) at all level/ depths ISI marked HDPE pipe 180 mm dia, PE-80 grade and PN 6 per design for portable water supply as per IS 4984-2016 (amended up to date) in trenches in complete, including cost of PE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer including cost of third party inspection (Make Duraline,Reliance,Jain Irrigation,Nimbus,Finolex,Hasti,or equivalent)(NS Item)
NS Item -Providing, laying, aligning, and jointing with butt fusion welding techniques (IS 7634 (Part 2) : 2012) at all level/ depths ISI marked HDPE pipe 110 mm dia, PE-80 grade and PN 6 per design for portable water supply as per IS 4984-2016 (amended up to date) in trenches in complete, including cost of PE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer including cost of third party inspection (Make Duraline,Reliance,Jain Irrigation,Nimbus,Finolex,Hasti,or equivalent)(NS Item)
NS Item -PProviding and lowering of HDPE floater manufactured with 225 mm dia PE pipe having PE-80 and PN-10 to float the submersible open well pump/motor ( Rates approved in TAC,MICADA Haryana meeting on 09.02.2022)
Bidder Name
Amount
BALAJI IRRITECH PVT. LTD. (GSTN-06AADCB5236F1Z0) BID ID -1041616
Krishan Kumar contractor (GSTN-06AXBPK5232G1ZT) BID ID -1042010
jaimal construction (GSTN-06AANFJ5487B1Z7) BID ID -1042467
SIYARAM IRRIGATION PVT LTD(GSTN-NA)--1042542
BALAJI IRRITECH PVT. LTD.
SIYARAM IRRIGATION PVT LTD
Krishan Kumar contractor
BALAJI IRRITECH PVT. LTD.
jaimal construction
Krishan Kumar contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .