| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.9 LAccepted-AOC RAWALPORA WANABAL PATI YAYIL POST OFFICE SANAT NAGAR SRINAGAR 190005 J K | SRINAGAR | JAMMU AND KASHMIR | 190005 | L1 | Accepted-AOC ACCEPTED BEING L1 | |
| 2 | L2₹27.1 L+₹37,211.70 (1.39%)Rejected-Finance | L2 | Rejected-Finance REJECTED BEING L2 | |
| 3 | L3₹29.3 L+₹2.6 L (9.78%)Rejected-Finance | L3 | Rejected-Finance REJECTED BEING L3 | |
| 4 | L4₹30.2 L+₹3.5 L (12.9%)Rejected-Finance | L4 | Rejected-Finance REJECTED BEING L4 | |
| 5 | L5₹31.2 L+₹4.5 L (16.8%)Rejected-Finance | L5 | Rejected-Finance REJECTED BEING L5 |
Tender Value
₹33.5 L
EMD Value
₹67,000
Closing Date
15 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 134 WORK ENGRS
HQ 134 WORK ENGRS, PIN-914134, C/O 56 APO
ADDITION/ALTERATION AND SPECIAL REPAIR TO BLDG NO T-155 AT KHREUH UNDER GE 861 EWS
2021_MES_422068_1
134 WE-80/2020-21
Open Tender
Civil Works
Item Rate
180 days
SRINAGAR
PLEASE SEE TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE 861 EWS
₹67,000
Yes
1 Apr 2021
13 Feb 2021
17 Mar 2021
13 Feb 2021
15 Mar 2021
1 Mar 2021
60 days
Amount
Taking down cement plaster on brick or concrete wall etc including racking out joint hacking for key, scrubbing down with water etc. complete all as specified and as directed.
Demolition of cement concrete in ground floors and paving not exceeding 15cm thickness (below or above ground level) complete all as specified or directed by the Engr-In-Charge.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete (reinforced) any description and in any position not otherwise specifically provided for and disposing off the rubbish materials where directed complete all as specified and directed by the Engr-in-Charge.
Taking down chowkats or frames with shutters (without taking shutters from the frame) exceeding 1.50 sqm but not exceeding 4.00 sqm each ,complete all as specified and directed by Engr-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) not exceeding 1.50 sqm each ,complete all as specified and directed by Engr-in-Charge.
Taking down shutters of any description exc 1.0 sqm but not exceeding 2.00 Sqm each leaf.
Excavation in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation or for shafts,wells,cess pits,,man holes pair holes etc not exc 10 sqm on plan and not exc 1.5m in depth and getting out in any type of soil complete all as specified and directed by Engr-in-Charge.
M&L for Plain cement concrete (1:4:8), type D-2 (using 40mm graded crushed stone aggregetes) as in foundations, filling and mass concrete, complete all as specified and directed by Engr-in-Charge.
M&L for RCC, M-25 (Design Mix), using 20 mm graded crushed stone aggregates as in foundation, rafts, footing, foundation beam, plinth beams, bases for coumns etc basement slabs complete all as specified and directed by Engr-in-Charge.
M&L for RCC, M-25 (Design Mix), using 20 mm graded crushed stone aggregates as in coloumns, pillers piers post and struts etc; complete all as specified and directed by Engr-in-Charge.
M&L for RCC, M-25 (Design Mix), using 20 mm graded crushed stone aggregates as in RCC bend, lintels over 1.5 meter span etc, complete all as specified and directed by Engr-in-Charge.
M&L for RCC, M-25 (Design Mix), using 20 mm graded crushed stone aggregates as in slabs supported on walls, beams and coumns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc complete all as specified and directed by Engr-in-Charge.
Formwork to sides of concrete foundations, footings, bases of columns , raft and raft beams, sides and soffits ( if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces complete all as specified and directed by Engr-in-Charge.
Use of waste formwork for RCC bend etc complete all as specified and directed by Engr-in-Charge.
Use of waste formwork for sides of columns etc complete all as specified and directed by Engr-in-Charge.
Use of waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for fair finished surfaces complete all as specified and directed by Engr-in-Charge.
S&F for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge.
All as per Serial item No 18 here-in-above but 5mm dia & over and including upto 10mm dia as in stirupps, spacers and binders complete all as specified and directed by Engr-in-Charge.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed by the Engr-in-Charge.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified Engineer-in-Charge.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls in cement mortar 1:4 complete all as specified Engineer-in-Charge.
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM (1:6) finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM (1:4) finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for 5mm thick rendering on fair faces of brick/ concrete surface in CM (1:3) finished even and fair without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for preparation of newly plastered surface and applying two coats of cement base paint on plastered surface of wall over one coat of alkali resistant primer complete all as specified and directed by Engr-in-Charge.
M&L for preparation of plastered or unplastered new surfaces of walls and applying three coats of white wash on walls complete all as specified and directed by Engr-in-Charge.
M&L for preparation of plastered or unplastered new surfaces of ceiling and applying three coats of white wash on ceiling complete all as specified and directed by Engr-in-Charge.
M&L for moorum/ red bajri filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering , complete all as specified and directed by Engr-in-Charge.
M&L for Hardcore of broken stone or boulders of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engr-in-Charge.
M&L for 100mm thick, PCC, M-10(1:3:6), type C-2 (using 40 mm graded crushed stone aggregate) as in sub base of floors and paving complete all as specified and directed by Engr-in-Charge.
M&L for non skid ceramic coloured tiles 7mm to 8mm thick, (square or rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM(1:4) complete all as specified and directed by Engr-in-Charge.
M&L for glazed ceramic coloured tiles (450x300mm) x 7mm thick, on vertical surface such as skirting, dados and risers to step etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tile including 10mm thick backing coat in CM (1:4) complete all as specified and directed by Engr-in-Charge.
M&L for 75mm thick PCC, M-10(1:3:6), type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection all around bldg finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
S&F for framed steel work such as in roof trusses, trussed purlin, crane gantries rails and fastening and heavy bracket framing (beam, tee, angle, channel or flat section) including dstances pieces, cleats etc of Fe 290, Gde E-165 including zinc chromate primer complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new or previously untreated steel surfaces of any description, not otherwise, described, over 10cm width or girth and applying two coats of synthetic enamal paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
Vitreous china White Squatting Orissa Pattern pan (Make : Somany Cat part No 121115 or equivalent of Hindware/Parryware) of size 580x440mm, including cast iron ‘P’ or ‘S’ trap, front or back inlet and integral foot rests and making connection to trap and to flushing pipe, anti syphonic pipe, fixed in repair including dismantling existing squatting pan and making good to disturbed floor, etc complete all as specified and directed.
Vitreous china Urinal, Half stall type white including 32mmm bore PVC waste pipe, PVC spreader, CP grating, providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plug with and including 60mm long brass screw, pointing around urinal back in coloured epoxy grout to match fixed in repair etc complete all as specified and directed. (Make : Jaquar Cat part No URS-WHT-13261 or equivalent of Hindware/Parryware)
S&F in repair 10 ltr capacity PVC valveless, syphonic action type, flushing cistern, low level white with inlet, ball valve, float and handle including bracket complete all as specified and directed by Engineer-in-Charge.
Vitreous china wash hand basin, white, flat back, size 550x400mm (Make : Jaquar Cat part No CNS-WHT-801 or equivalent of Hindware/Parryware/Somany) including 15mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated (Make : Jaquar Cat part No FLR-5011N or equivalent of Hindware/Marc.) brackets, CP waste coupling, 32mm bore PVC waste pipe of min 600mm long, including cutting for and pinning in end of brackets or erecting stand, fixed in repair, including taking out existing wash hand basin etc complete all as specified and directed.
S&F in repair PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed by Engineer-in-Charge.
S&F in repair Swivel shower rose (in repair) of PTMT any colour with arm 195mm long with bend of 45 degree with flange (both minimum weight 80gms) ,complete all as specified and directed by Engr-in-Charge.
S&F in repair 75mm PVC floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1,M-15 (1:2:4) complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) gully trap 125/110 mm , setting and jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
15mm bore bib taps fancy type with wall flange, chromium plated cast copper alloy long body with capstan heads, screwed for iron pipe or brass ferrule, fixed in repair etc complete all as specified and directed. Make : Jaquar Cat part No FLR-5047N or equivalent of Hindware/Marc.
15mm bore chromium plated angular stop cock with wall flange of cast copper alloy, fancy type, with capstan head, screwed both ends for iron pipe, fixed in repair etc complete all as specified and directed. Make : Jaquar Cat part No FLR-5053N or equivalent of Hindware/Marc.
Rotational moulded polyethylene water storage tanks three layer of capacity 500 litre, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm ball valve high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball etc complete including taking out existing water tanks of any description all as specified & directed.
S&F in repair Gun metal globe or gate valves 20mm bore, with iron wheel head screwed head both for iron pipe and fixed complete all as specified and directed by Engr-in-Charge.
M&L for plain solid straight chowkats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pins at joints of 2nd class hard wood, complete all as specified and directed by Engr in Charge
S&F for 35mm thick 2nd class soft wood(kail) Plain, framed, panelled shutter (any number of panels), with panel of timber flat on both sides (feather edged) or of venerred partical board medium denisty, wood particle board with commercial face veneers and fitted to chowkats, complete all as specified and directed by Engr-in-Charge.
S&F for 2nd class soft wood (kail) glazed and skeleton shutter 35mm thick open rebated and prepared to receive glass gauze etc (internal sash bars) edges of framing plain chamferred or rounded, fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR Part I section 8 clause 8.24 (a) supplied and fitted to chowkhats, complete all as specified and directed by Engr-in-Charge.
S&F for Second class soft wood, Glazed and skeleton shutters, 30mm thick, open rebated and prepared to receive glass, gauze, etc.(with sash bars) edges of framing plain, cham-fered or rounded, mitred and rebated sash bars, any numbers and mitred beads for securing glass, etc. sizes of members of window/ventilator shutters as specified in SSR Part I, Section 8. clause 8.24 (b); supplied and fitted to chowkats complete all as specified and directed by Engr-in-Charge.
M&L for 4mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in square not exceeding 0.5 sq.m. in each pane including hacking out old broken glass panes any thickness and size quality or description from wooden frames complete all as specified and directed by Engr-in-Charge.
S&F for PVC solid door frame of size 50mm x 47mm made out of 5mm single sheet colour PVC sheet reinforced with MS square tube, complete all as specified and directed by Engr-in-Charge.
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement,complete all as specified and directed by Engr-in-Charge.
S&F in repair MS steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm fixed with stainless steel wire staples complete all as specified and directed by Engr-in-Charge
S&F for aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed, 300mm size complete all as specified and directed by Engr-In-Charge.
S&F for 200mm size aluminium anodised, barrel tower bolt of extruded section complete all as specified and directed by Engr-In-Charge.
S&F for 150mm size aluminium anodised, barrel tower bolt of extruded section complete all as specified and directed by Engr-In-Charge.
S&F for 150mm aluminium handles extruded febricate type complete all as specified and directed by Engr-In-Charge.
S&F for Butt hinges 125mm in size, Medium weight, cold rolled mild steel, including welding to steel frame at site complete all as specified and directed by Engr-In-Charge.
S&F for Butt hinges 100mm in size, Medium weight, cold rolled mild steel, including welding to steel frame at site complete all as specified and directed by Engr-In-Charge.
S&F for Butt hinges 75mm in size, Medium weight, cold rolled mild steel, including welding to steel frame at site complete all as specified and directed by Engr-In-Charge.
S&F for MS helical door spring including roller & roller plate complete 300mm size complete all as specified and directed.
S&F for floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor overall length of cover plate 150mm complete all as specified and directed by Engr-in-Charge.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engr-in-Charge.
S&F for 0.63mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with `L' or J type or cranked hook bolt with washers, in roofs, walls etc. complete all as specified and directed by Engr-in-Charge.
S&F for 0.63mm thick plain, corrugated mild steel sheeting in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with zinc coating 275 grams/sqm complete all as specified and directed by Engr-in-Charge.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc)or insulation board/slabs/blankets, any thickness including covering fillet complete all as specified and directed by Engr-in-Charge.
S&F for plain anodised aluminium snap grid, frame work of size 605x605mm for false ceiling including straining with GI wire 4mm thick (upto 1200mm lenght) adjusting level, fix to roof by means of ceiling cleats made out of GI flat 40x30mm for and including 10mm thick PVC insulation panels with EPS stuck to 1mm thick plain PVC sheet suitably placed in false ceiling grid made of aluminium GI/MS as per specification and drawing complete all as specified and directed by Engr-in-Charge.
M&L for Kota stone slab as in flooring, 20-25mm thick and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, laid over 15mm thick screed bed or bedding in cement mortar 1:4, complete all as specified and directed by Engr-in-Charge.
All as per Serial item No 72 here-in-above but on vertical surface of walls/skirting/dado etc complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new surface of wall for applying two coat of oil bound distemper over a coat of alkali resistant primer and a layer of 3mm thick wall care putty complete all as specified and directed by Engr-in-Charge.
Non skid ceramic joint free coloured tiles 7mm to 8mm thick, (square or rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM(1:4) complete all as specified and directed by Engr-in-Charge.
Taking up or down 15mm dia GI tubing and connections including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20mm dia GI tubing and connections including cleaning for refixing or removal to store complete all as specified and directed.
S&F 15mm bore GI tubing med grade galvanised with all fittings and fixed complete to walls & floors etc all as specified and directed.
S&F 20mm bore GI tubing med grade galvanised with all fittings and fixed complete to walls & floors etc all as specified and directed.
S&F in repair PVC (SWR) pipe single socketed in any length with rubber ring joints laid in trenches or floors, 75mm bore pipe complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) pipe single socketed in any length with rubber ring joints laid in trenches or floors, 110mm bore pipe complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) pipe single socketed in any length with rubber ring joints laid on walls, 75mm bore pipe complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) pipe single socketed in any length with rubber ring joints laid on walls, 110mm bore pipe complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) bends (any radius) 75mm bore with access door complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) vent cowl of bore 110mm complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) vent cowl of bore 75mm complete all as specified and directed by Engr-in-Charge.
S&F in repair aluminium anodised tubular towel rail, 20 mm dia, D type, 60 cm long between flanges (fixed in repair), complete all as specified and directed by Engr-in-Charge.
S&F for repair 2nd class hardwood planks, boarding planed one side 40mm thick , with butt joints and fixed with nails complete all as specified and directed by Engr-in-Charge.
M&L for 2nd class soft-wood weather boarding, clean sawn, plain, 20mm thick or feather edged 15mm to 20mm thick and fixed in 30mm laps including dismantling boarding (weather boarding), fixed in any position with nails complete all as specified and directed by Engr-in-Charge.
Dismantling timber scantlings, unframed work, 40 sq. cm and over in section, in any position, complete all as specified and directed by Engr-in-Charge.
Dismantling timber scantlings, framed work, 40 sq. cm and over in section, in any position, complete all as specified and directed by Engr-in-Charge.
S&F in repair timber frame in second class soft-wood, clean sawn, complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new wooden surfaces exceeding 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old wooden surfaces exceeding 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
M&L for preparing of plastered or unplastered old surfaces of walls & applying two coats of cement base paint on walls (external) including removal of existing tretment complete all as specified and directed by Engr-in-Charge.
Complete removal of existing treatment & preparation of plastered or unplastered new undecorated surface of wall and applying two coats of cement base paint on walls over one coat of alkali resistant primer, wall care putty 3mm thick, complete all as specified and directed by Engr-in-Charge.
Taking down carefully copper/aluminium point wiring (light, fan, light & power socket) complete including fittings such as switches, sockets, bell pushes, ceiling roses, pendants/batten holder, call bell,fan, regulators, tube light fittings, bulk head etc. and making good to the disturbed surface of wall, floors, ceiling in CM 1:3 to match with existing finish etc complete all as specified and directed. Note: Fan shall be taken down and refixing will be measured and paid for seperately.
M&L for point wiring using FR PVC insulated unsheathed /multi stranded copper conductor cable 1.5 sqmm including 1.5 Sqmm FR PVC insulated unsheathed copper conductor earth wire drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bend, junction box and pressed steel sunken box 60 mm deep & 1.6 mm thick duly painted inside and anticorrosive out side for mounting switches, sockets, fan regulators etc with 3mm thick plastic laminated sheet cover of suitable size, connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etc (conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible), for light/fan/bell point etc complete all as specified and directed. (Note : Switch/bell push/fan regulator etc shall be measured and paid separately)
All as per Srl item No. 98 above but for 5 Pin 5 Amp socket outlet point controlled by one switch 5 Amps one way on same board, etc complete all as specified and directed.
All as per Srl item No. 98 above but for 5 pin 5 Amp socket outlet point on independent board controlled by one switch 5Amp one way, etc complete all as specified and directed.
All as per Srl item No. 98 above but for one 15Amp socket outlet point concealed using 2.5Sqmm FR PVC insulated multi-strand copper conductor wire including 1.5Sqmm FR PVC insulated unsheathed copper conductor earth wire and making good to disturbed surfaces of wall floor to match existing finishes etc complete all as specified and directed.
Sub main wiring with FR PVC insulated unsheathed 2X4 sqmm multistranded copper conductor cable 1100 V with 1X4 sqmm FR PVC insulated green multistranded copper cable for continuous earth drawn through & including concealed PVC conduit of appropriate size not less than 20 mm dia & 1.8mm wall thickness with all accessories including cutting grooves and making good disturbed surface to match existing including taking down existing surface sub main wiring etc complete all as specified and directed. Note : Two run of cable for phase, neutral and one run of cable for earth including conduit will be measured and paid as one unit length.
Switch piano flush type, single pole, 16 Amp, one way, AC 230 volts etc complete, all as specified and directed. Make : Anchor (Penta) Cat Part No : 38477 or equivalent of Havells/ SSK
Switch piano flush type, single pole, 16 Amp, one way, AC 230 volts etc complete, all as specified and directed. Make : Anchor (Penta) Cat Part No : 38477 or equivalent of Havells/ SSK
Socket outlet, 2 in 1, 5 pin, 6 Amp & 16 Amps, flush type, AC 230 volts etc complete all as specified and directed. Make : Anchor (Penta) Cat Part No : 38397 or equivalent of Havells/ SSK
Socket outlet, 2 in 1, 5 pin, 6 Amp, flush type, AC 230 volts etc complete all as specified and directed. Make : Anchor (Penta) Cat Part No : 38364 or equivalent of Havells/ SSK
Ceiling rose polycarbonate isolated body surface Bakelite, not less than 50x20mm, three terminals, AC 230 volts etc complete all as specified and directed. Make : Anchor (Penta) Cat Part No : 39040 or equivalent of Havells/ SSK
S&F in repairs of LED batten with poly carbonate housing and integrated electronic drive 1x18 watts 4 feet light fitting with white acrylic cover along with LED lamp white colour compete including connecting up with twin core twisted flixible copper conductor cable with suitable size all as directed. Make : Bajaj Cat Part No BCLSB18NW or equivalent of Philips/Crompton/ Wipro Note : CA No shall be written on each fitting before installation.
Street/Security light LED , 25 Watt energy savings and environmental friendly long life versatile pressure die cast aluminium fittings including necessary brackets and clamps complete connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and directed by Engineer-in-Charge. Make : Bajaj Cat Part No BRLEP25WLED (edge plus) or equivalent of Philips/Crompton/ Wipro Note : CA No shall be written on each fitting before installation.
Lamp holder(in replacement) insulated body with back plate suitable for batten fitting including LED lamp of capacity 9 watts complete all as specified and directed by Engr-in-Charge.
Taking down old ceiling fan including supply and fix 1200mm sweep heavy duty ceiling fan of 5 star rating, energy saving model with double ball bearing 230 volts 3 blades white in colour without regulator COMPLETE WITH CANOPY and suitable DOWN ROD all as directed: Note: Old UNSV fans will be deposited at MES store yard. Make : Havells or equivalent in Usha/CG/Bajaj.
S&F wall mounted LD picutre/mirror light LED 6Watt aluminium with silver finish complete all as specified and directed by Engr In Charge. Make : Philips commercial code No 30973, 12 NC code No 919215850143 or equivalent Wipro/CG/Havells.
S&F in repair energy efficient highly rating heavy duty exhaust fan 300mm sweep with louvers including making hole in wall as it where required and connecting electrically to ceiling rose or connector block using PVC insulated and overall sheathed 3 core cables of size 0.75sqmm with flexible copper conductor all as required at site. complete all as specified and directed by Engr-in-Charge. Make : CG/Havells/USHA
S&F in repair MCCB Distribution Board, TP&N, vertical, double door, sheet steel, enclosure powder coated with 100 Amps rated bubar with neutral link 415 volts 4 way fixed on wall duty grouted in solid block wall or on wooden board with electrical connection complete including 3 Pole V-Tech MCCB of 100 A rating & 16 K breaking capacity, MCCB pre-fitted at factory complete all as specified and directed by Engineer-in-Charge. Make : Indiasian cat part No KSLTVM04 or equivalent in Legrand/Havells.
Double door MCB DB SPN, 240 Volts, 08 Way made out of CRCA powder coated sheets, IP43 protection with copper bus bar including taking out old unsv MCB DB any size/type, etc complete all as specified and directed. Make: Legrand Cat Part No 6077-11 or equivalent of L&T/ABB/SCHNEIDER
MCB single pole neutral (SPN) 240 volts, 40 to 63 Amps, 10KA (C-series) of approved make and cat part etc complete all as specified and directed.
MCB single pole (SP) 240 volts, 6 to 32 Amps, 10KA (C-series) of approved make and cat part etc complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 metre in depth for foundation of poles/stay/cable etc including getting out in any kind of soil complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, and well ramming, in layers not exceeding 25 cm thick , complete all as specified and directed by Engr-in-Charge.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
Sand cushioning to underground cables 8cm thick before laying cable and 15cm thick after lying and streching the cable, complete all as specified and directed by Engr-in-Charge. Note :- For payment purpose punned thickness shall be measured.
M&L for brick well burnt locally available sub class 'B' laid over sand cushioning to cable for cable protection keeping width of brick parallel to the length of cable complete all as specified and directed by Engineer-in-Charge.
1100 volt grade XLPE insulated heavy duty cable, 16 sqmm 2 core, strip armoured with aluminium stranded conductor overall PVC sheathed laid in trenches including taking down existing cable etc complete all as specified and directed. Note : Excavation & Earthwork shall be measured and paid separately.
Supply and fixing of Geyser of capacity 50 litres with 4 star rating including nuts, bolts, connection pipe and gaskets etc and fixing in same position and testing including removing old UNSV the geysers from building and depositing to MES store yard (old UNSV geyeser will be deposited at MES store yard) complete all as specified and directed by Engineer-in-Charge. Make : Havells Monza EC or equivalent in Bajaj/CG.
S&F GI water tubing light grade 25mm dia bore, ISI marked, with all fittings and fix complete laid in trenches, complete all as specified and directed by Engr-in-Charge as per following size: Make: Jindal/Swaktik/Surya/Prakash.
S&F GI water tubing light grade 20mm dia bore, ISI marked, with all fittings and fix complete laid in trenches, complete all as specified and directed by Engr-in-Charge as per following size: Make: Jindal/Swaktik/Surya/Prakash.
S&F in repair Gun metal globe or gate valve 25mm dia bore non rising spindle heavy duty with iron wheel head, screwed both end for connection GI pipe complete all as specified and directed by Engr-in-Charge as per following size (ISI marked): Make: Kirloskar/Bir/Varun/Venus/Leader/Sant.
S&F in repair Gun metal globe or gate valve 20 mm dia bore non rising spindle heavy duty with iron wheel head, screwed both end for connection GI pipe complete all as specified and directed by Engr-in-Charge as per following size (ISI marked): Make: Kirloskar/Bir/Varun/Venus/Leader/Sant.
Supplying installing, commissioning testing in repair LT cubical feeder piller box out door kiosk type made ou tof CRCA sheet 3.15mm, 3 phase 4 wire 50 C/S AC with aluminium bus bar of 250 Amps rating fixed on insulators for incoming & outgoing taping complete double door type with locking arrangement fixing on PCC platform with suitable nuts, bolts dully painted with two coats of synthetic enameled paint over a coat of red oxide primer, comprising with MCCB 160 Amps TPN 50Hzs, 35KA (01 Nos) in coming and MCCB 100 Amps TPN, 25 KA (01 Nos), MCB 40 Amps SPN C curve (02 Nos) cable for service connection complete all as specified. Make: Havells/Legrd/L&T
Earthing complete with galvanised steel earth plate electrode 600x600x6mm burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5mtr below normal ground level connected to the Galvanised iron strip 32x6mm size by means of bolts ,nuts,check nuts and washers of galvanised iron and 32x6mm GI strip procted by provision of GI light grade pipe 40 mm bore incl provision of concrete pit in PCC1:2:4 type B-1, using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil ,charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mesh and medium grade GI protection pipe 15mm bore 5 Mtr long and GI strip upto main earthing of pole complete all as shown in electrical plate No 3 of MES Sch 2009 Part-I all as specified and directed. Notes:- (i) Main earthing strip from earth plate electrode to test point upto length of 7.5 metres length shall deem to be included in the unit rate quoted against this item. (ii) GI protection pipe & earthing lead beyond 7.5 metres shall be measured and paid for seperately under appropriate item of Sch A part-I. (iii) On testing after completion if desired resistanace is not obtained, the contrator shall redo the earthing without any extra cost to the department.
M/S BHAT CONSTRUCTION AND BUILDERS
Javeed And Co
M/S AK ENTERPRISES
NAJAR ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .