Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹82.0 CrAccepted-AOC RAM PLAZA NAVASHAKTI CHOWK BHABHA NAGAR NASHIK 422 011 | NASHIK | NASHIK | MAHARASHTRA | 422011 | ₹82.0 Cr | 1 | Accepted-AOC L1 |
| 2 | 2₹89.4 CrRejected-AOC HARSH ANAND YEVALEKAR MALA COLLEGE ROAD NASHIK 422005 | NASHIK | NASHIK | MAHARASHTRA | 422005 | ₹89.4 Cr | 2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | Harsh Constructions Pvt Ltd L2 | Pawar Patkar Constructions Pvt.Ltd. L1 |
|---|---|---|---|---|---|
| 1.00 | Removing grass, gazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc. complete. | 94,866.58 | Square Metre | 12 ₹11.4 L | 8 ₹7.6 L |
| 2.00 | Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5meter to 3.0meter) By Manual Means | 12,533.39 | Cubic Metre | 345 ₹43.2 L | 316 ₹39.6 L |
| 3.00 | Excavation for foundation in hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0 metre) By Manual Means | 2,877 | Cubic Metre | 454 ₹13.1 L | 434 ₹12.5 L |
| 4.00 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 1.5metre To 3.0 metre) | 3,764.19 | Cubic Metre | 574 ₹21.6 L | 549 ₹20.7 L |
| 5.00 | Excavation for foundation in Hard-rock by blasting including trimming and leveling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the building area including dewatering and back filling with available earth/murum watering, ramming etc. complete. (Lift from 1.5 metres To 3.0 metres) | 2,973.9 | Cubic Metre | 1,300 ₹38.7 L | 1,071 ₹31.9 L |
| 6.00 | Filling in plinth and floors with contractors material/brought from outside and approved by Engineer in charge in layers of 15 centimetre to 20 centimetre. including watering and compaction etc. complete. Spec. No. : Bd.A. 11/Page No. 263 | 11,477.69 | Cubic Metre | 1,200 ₹1.4 Cr | 861 ₹98.8 L |
| 7.00 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand Vertical Shaft Impactor Grade finely washed etc) | 3,590.81 | Cubic Metre | 6,800 ₹2.4 Cr | 6,121 ₹2.2 Cr |
| 8.00 | Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete. | 2,834.57 | Cubic Metre | 6,500 ₹1.8 Cr | 5,739 ₹1.6 Cr |
| 9.00 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controllers with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand / Vertical Shaft Impactor quality Artificial Sand | 2,924.29 | Cubic Metre | 16,585 ₹4.8 Cr | 15,862 ₹4.6 Cr |
| 10.00 | Providing and laying in situ / Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying / pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controllers with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/Vertical Shaft Impactor quality Artificial Sand. | 3,374.06 | Cubic Metre | 9,000 ₹3.0 Cr | 8,321 ₹2.8 Cr |
Updated dates
Tender Value
₹78.3 Cr
EMD Value
₹39.1 L
Closing Date
21 Jan 2026, 5:00 pmClosed
CE MSIDC
13th Bakhtawar building Nariman Point
Construction of Laxmi Narayan ghat, Someshwar waterfall Ghat and Navshya Ganpati ghat at Tal District Nashik
2025_MSIDC_1262205_1
21
Open Tender
Civil Works
365 days
Nashik
Please refer Tender documents.
7 documents required · 7 mandatory
₹35,400
Yes
₹39.1 L
Yes
CE MSIDC
17 Apr 2026
22 Dec 2025
23 Jan 2026
22 Dec 2025
21 Jan 2026
22 Dec 2025
29 Dec 2025
Removing grass, gazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc. complete.
Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5meter to 3.0meter) By Manual Means
Excavation for foundation in hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0 metre) By Manual Means
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 1.5metre To 3.0 metre)
Excavation for foundation in Hard-rock by blasting including trimming and leveling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the building area including dewatering and back filling with available earth/murum watering, ramming etc. complete. (Lift from 1.5 metres To 3.0 metres)
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer in charge in layers of 15 centimetre to 20 centimetre. including watering and compaction etc. complete. Spec. No. : Bd.A. 11/Page No. 263
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand Vertical Shaft Impactor Grade finely washed etc)
Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete.
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controllers with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand / Vertical Shaft Impactor quality Artificial Sand
Providing and laying in situ / Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying / pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controllers with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/Vertical Shaft Impactor quality Artificial Sand.
Providing and fixing in position Thermo Mechanically Treated - FE - 500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
Centring and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Providing and laying weep holes of 100 millimetre diameter Asbestos cement / Poly Vinyl Chloride pipes as per drawing for abutment returns, return walls etc. Complete.
Providing and laying of filter media with granular materials/ stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2 of MoRTH specifications to a thickness of not less than 600 millimetre with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition as per drawing and technical specifications etc. complete.
Providing Autoclaved Aerated Concrete Block masonary approved make conforming to IS:2185 (Part3) -1984 in extra fine jointing mortar in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)
Providing and constructing masonry in precast solid Concrete Block (Grade D-50 As per Indian Standards 2185, Part-I, 1974, Reframed 1987) having compressive strength 5-00 N/mm2) of size (300 millimetre x 200 millimetre x 150 millimetre) in cement mortar 1:6 for superstructure including striking joints on unexposed faces, racking out joints on exposed faces, watering, curing and scaffolding etc. complete.
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete.
Providing internal cement plaster 12 millimeter thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.
Providing and fixing 60 millimetre thick. Machine cut basalt stone, dressed with undulated finish as per approved pattern and sample, in required position laid on a bed of 25 millimetre thk 1:4 cement mortar including cement float, machine cutting, dressing, leveling, jointing, filling joints with matching colour cement slurry / cement mortar (1:3) inclusive of pointing the joints (joints thk 6 mm ) fixed over surface / concrete bed or as shown on the drawing, curing, finishing, chaphored edges wherever necessary etc complete as directed by engineer in charge. (Prefarable size in 120X60 centimetre)
Providing and fixing machine cut machine polished 18 millimetre to 20 millimetre thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
Providing and fixing heavy duty inter locking concrete Gray paving blocks of 80 millimetre thickness of having a strength of 300 kilogram per Square metre of approved quality and shape on a bed of crushed sand of 25 to 30 millimetre thick including skirting joints and cleaning etc. complete.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding Indian Standard of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete.
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)
Supplying and stacking of good earth at site including royalty and carriage upto 5 kilometre lead complete (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking sludge at site including royalty and carriage upto 5 kilometre lead complete (sludge measured in stacks will be reduced by 8% for payment).
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
Providing Square Cement Concrete pots of specified size, cast with cement concrete of nominal mix 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size), reinforced with 7 Nos ( 3 nos horizontal & 4 nos vertical ? U ? shape) Mild Steel wires of 3.5 millimetre diameter as per design, including required frame work, finishing with cement punning on exposed surface, curing for specified period and stacking in required rows & height, all complete as per direction of Officer-in-charge Top inner width 35 cm, outer bottom width 25 centimetre, total height 35 cm and wall thickness 25.4 millimetre
Filling of the following size empty pots with mixture of good earth & manure in the ratio of 2:1 (Two part of Good earth & one port of manure) and placing them on approprite place i/c carriage of earth, manure and pots up to 50 meter, as per direction of officer incharge. (The cost of good earth, earthen pots & manure will be paid seperately.) 30.2.31.3 Size of Empty Pots 20cm Top dia, 12 centimetre Bottom Dia & 20 centimetre Perpendicular height
Complete maintenance of the entire garden features having as per yard stick in the garden area i.e. lawn trees, shrubs, herbs, hedge, flower beds, foliages, creepers etc. including hoeing, weeding pruning replacement of plants, gap filling, watering, mowing of lawn, grass cutting by lawn mover and brush cutter , removal of garden waste, applying insecticide, pesticide & fertilizers(whenever required) top dressing of lawn with good earth and manure and maintenance of other garden related works as directed by office-in-charge (Cost of Good Earth, Manure, Fertilizer, Insecticide , Pesticide , lawn mover and brush cutter with fuel will be provided by the Department & other T & P material/articles shall be provided by the contractor.)and as per direction of officer in charge. 30.2.39.1 Prestigious works / H.M. house & officers entitled to free accommodation. (1.00 Acre=One Mali) As per yard stick
Providing Circular Cement Concrete pots of specified size, cast with cement concrete of nominal mix 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 millimetre nominal size), reinforced with 7 Nos ( 3 nos horizontal & 4 nos vertical ? U ? shape) Mild Steel wires of 3.5 millimetre diametre as per design, including required form work, finishing with cement punning on exposed surface, curing for specified period and stacking in required rows & height, all complete as per direction of Officer-in-charge.Top inside dia 30 centimetre, outer bottom dia 20 centimetre, total height 30 centimetre with wall thickness of 25.4 millimetre
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material?s as per direction of officer in charge (excluding cast of plant & water ) Cost of plantation per trees plants (for 100 nos.=427.45/100)
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material?s as per direction of officer in charge (excluding cast of plant & water ) Cost of plantation per Shrubs plants (for 200 nos.=427.45/200)
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material?s as per direction of officer in charge (excluding cast of plant & water ) Cost of plantation per Hedge plants (for 300 nos.=427.45/300)
Five years old tree
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 meters beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 meter)
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 meter) By Mechanical Means
Centring and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressummers and cantilevers
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing Mangalore tiled roofing with class 'AA' tiles including securing the last course of tiles near the eaves with steel flat 40 millimetre x 3 millimetre and 1.22 millimetre wire fixing country teak wood sloping battens of 25 x 12 millimetre teak wood horizontal battens of 50 millimetre x 25 millimetre over the slopping battens, all iron work and coal tarring the battens etc. complete (Excluding ridge and hip tiles).
Providing and fixing Mangalore tile ridge and hip tiles of class 'AA' including scaffolding if necessary, pointing with coloured cement mortar and curing etc. complete.
Providing and fixing fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing accessories in all colours with polymer coated J or L hooks, bolts and nuts and or Galvanized Iron seam bolts and nuts, Galvanized Iron plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete: Eave’s filler pieces
15 millimetre cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand)
Providing and Fixing factory made Unplasticised Poly vinyl Chloride door frame, made of Unplasticised Poly vinyl Chloride extruded sections, of size 65 millimetre x 55 millimetre with wall thickness 2.0 millimetre (± 0.2 millimetre), corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with Poly vinyl Chloride profile of Size 28 millimetre x 30 millimetre having wall thickness 2 millimetre (±0.2 millimetre), including providing & fixing 3 nos of 125 millimetre long stainless steel hinges to the frame, fixing the frame with jamb with required number & size of anchor dash fastners, all complete as per manufacturer’s specification and direction of Engineer-in-charge.
Providing and fixing factory made Unplasticised Poly vinyl Chloride glazed/wire mesh windows/ doors comprising of lead free Unplasticised Poly vinyl Chloride multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 millimetre for Series R1 and R2 profiles and 2.10 millimetre for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, Unplasticised Poly vinyl Chloride extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per Indian Standards 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of Unplasticised Poly vinyl Chloride profiles to be as per design approved by Engineer-in-Charge. Casement window single panel with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles. Using R4 series with frame (64 millimetre & above) x (50 millimetre & above) & sash (64 millimetre & above) x (70 millimetre & above). (Height above 1.8 metre)
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 square metre per kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete.
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 millimeter to 605 millimeter x 590 millimeter to 605 millimeter of 8 to 10 millimeter thickness and confirming to Indian Standard 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. a) Flooring
Deduct for not using 20 millimetre thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3 kilogram per square metre.
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.
Providing and applying one coat of seal cement primer of approved manufacture and shed including scaffolding preparing the surface by cleaning dirt and other foreign matters, scrapping if necessary including scaffolding etc. complete.
Deduct for not using 20 millimetre thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3 kilogram per square metre.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 centimetre measured at a height of 1 metre above ground level and removal of rubbish up to a distance of 50 metre outside the periphery of the area cleared.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 metre in width or 10 square metre on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 metre, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metre All kinds of soil.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 5 kilometre also including ramming and watering of the earth in layers not exceeding 20 centimetre in trenches, plinth, sides of foundation etc. complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 millimetre nominal size derived from natural sources)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 millimetre nominal size) up to plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per Indian Standards: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centring, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: All works up to plinth level Concrete of M30 grade with minimum cement content of 350 kg /cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per Indian Standards: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centring, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: All works above plinth level up to floor V level Concrete of M30 grade with minimum cement content of 350 kg /cum
Centring and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centring and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressummers and cantilevers
Providing and laying autoclaved aerated cement blocks masonry with 150 millimetre/ 230 millimetre/ 300 millimetre thick AAC blocks in super structure above plinth level up to floor V level with Reinforced Cement Concrete band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of Reinforced Cement Concrete band and reinforcement shall be made for separately).
Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 millimetre nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately).
Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 millimetre nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately).
Providing and fixing fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing accessories in all colours with polymer coated J or L hooks, bolts and nuts and or Galvanized Iron seam bolts and nuts, Galvanized Iron plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete: Eave’s filler pieces
15 millimetre cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand)
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 millimetre (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 leter/10 square meter over and including priming coat of exterior primer applied @ 0.90 litre/10 square meter)
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete.
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 meters beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 meter)
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 meter) By Mechanical Means
Providing and fixing in position Thermo Mechanically Treated - FE - 500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to Indian Standards: 15622, of approved make, in all colours and shades, laid on 20 millimetre thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kilogram per square meter including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 millimetre
Providing and Fixing factory made Unplasticised Poly vinyl Chloride door frame, made of Unplasticised Poly vinyl Chloride extruded sections, of size 65 millimetre x 55 millimetre with wall thickness 2.0 millimetre (± 0.2 millimetre), corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with Poly vinyl Chloride profile of Size 28 millimetre x 30 millimetre having wall thickness 2 millimetre (±0.2 millimetre), including providing & fixing 3 nos of 125 millimetre long stainless steel hinges to the frame, fixing the frame with jamb with required number & size of anchor dash fastners, all complete as per manufacturer’s specification and direction of Engineer-in-charge.
35 millimetre thick factory made Solid panel Poly vinyl Chloride Door shutter, made out of single piece extruded solid Poly vinyl Chloride profiles, 5 millimetre (± 0.2 millimetre) thick, having styles & rails (except lock rail) of size 95 millimetrex 35 millimetre x 5 millimetre, out of which 75 millimetre shall be flat and 20 millimetre shall be tapered (on both side), having one side thickness of 15 millimetre integrally extruded on the hinge side of the profile for better screw holding power, including reinforcing with MS tube of size 40 millimetre X 20 millimetre x 1 millimetre, joints of styles & rails to be mitered cut & joint with the help of Poly vinyl Chloride solvent cement, self driven self tapping screws & Mild Steel rectangular pipes bracket of size 190 mm X 100 mm of cross section size 35 millimetre x 17 millimetre x 1 millimetre at each corner. Single piece extruded 5 mm thick solid Poly vinyl Chloride Lock rail of size 115 millimetre x 35 millimetre, out of which 75 millimetre to be flat and 20 millimetre to be tapered at both ends, having 15 millimetre solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125 millimetre x 11 millimetre, including providing 5 mm Single piece solid Poly vinyl Chloride extruded sheet inserted in the door as panel, all complete as per manufacturer’s specification and direction of Engineer-in-charge. Decorative finish (wood grained finish)
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 meters beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 meter)
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
MSB Supply, installation, testing and commissioning of 63A MV Cubicle panel. Fabricated out of 16 swg CR CA sheet, powder coated, dust and vermin tight proof, front opening type , cable bottom entry type, flush and wall mounted free standing on 4” MS channel directly bolted to wall using nuts and bolts stenciling all identification etc.. confirming to IS1863,IE rules . INCOMER 63A 4P 36kA Microprocessor based MCCB with all isolation duty with inbuild E/F release – 1Nos 63A 4P isolator - 1No (DG Side) 63A 4P ATS - 1 No. Class B&C type-1,type-2 surge arrestor - 1Nos Multi function meter - 1 No. RYB Indication Lamp - 2 Set OUTGOINGS 32A DP MCB with provision for metering- 6Nos 32A TPN MCB with provision for metering- 2Nos 32A TPN isolator- 1 Nos (electrical and mechanical interlocking shall be done ) Busbar Corresponding to 63A All MCCBs are Rotary operated.
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 4 core 10 sq mm
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil) 3 core 10 sqmm
Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil) 3 core 10 sqmm
Supplying and laying of following size DWC HOPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 3 core 10 sqmm
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 2 core 10 sq mm
Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil) 2 core 10 sq mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required 2 core 10 sq mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 core 10 sq mm (22 mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 core 10 sq mm (19 mm)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 8 Way, Double door
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required 25 amps
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Labour for Installation, testing & commissioning of 3 phase 62.5 KVA Diesel generator, including required earthing, power/control cabling, terminations including getting the necessary clearance/ approval of generator from electrical inspectorate, testing of neutral CT, relays, meters etc.. as required[statutory charges shall be borne by the clients on production of valid proof][ Mechanical erection of packaged generator will be done by the generator supplier
Supply and Labour charges for erection of additional length of MS B class medium grade exhaust pipe line of suitable sizes ,with heat resistant Al painting to building top for 62.5KVA DG.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amps
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amps socket outlet
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x2.5 sq.mm + 1x2.5 sq.mm earth wire
supply and Labour for fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc.6m Double arm Pole light(100W) - Make : K LITE
supply and Labour for fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc. 2.5m Pole light(50W) - Make : K LITE
supply and Labour for fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc.15W Hanging light(LED type)
supply and Labour for fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc.9W wall light
supply and Labour for fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc.Bollard light 12W
supply and Labour for fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc.Wall fan
supply and Labour for fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc.IP 65 Junction box suitable for 3 c x 2.5 sqmm copper cable
supply and Labour for fixing, testing and commissioning of CCTV including CAT-6 cable and POE switch etc.
MSB Supply, installation, testing and commissioning of 125A MV Cubicle panel. Fabricated out of 16 swg CR CA sheet, powder coated, dust and vermin tight proof, front opening type , cable bottom entry type, flush and wall mounted free standing on 4” MS channel directly bolted to wall using nuts and bolts stenciling all identification etc.. confirming to IS1863,IE rules . INCOMER 125A 4P 36kA Microprocessor based MCCB with all isolation duty with inbuild E/F release – 1Nos 125A 4P isolator - 1No (DG Side) 125A 4P ATS - 1 No. Class B&C type-1,type-2 surge arrestor - 1Nos Multi function meter - 1 No. RYB Indication Lamp - 2 Set OUTGOINGS 63A TPN 25kA Thermomagnetic Type MCCB with Variable setting with shunt release- 3Nos 63A TPN isolator- 1 Nos (electrical and mechanical interlocking shall be done ) Busbar Corresponding to 125A All MCCBs are Rotary operated.
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 3.5 Core 50 sqmm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2 50 sq mm (35 mm)
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc.
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 3 module
supply and Labour for fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc. 12m Pole light(200W) - Make : K LITE
supply and Labour for fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc. 6m Double arm Pole light(100W) - Make : K LITE
supply and Labour for fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc. 2.5m Pole light(50W) - Make : K LITE
supply and Labour for fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc. Ceiling Recessed down light 6W
supply and Labour for fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc.Ceiling Recessed down light 9W
supply and Labour for fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc.15W Hanging light(LED type)
supply and Labour for fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc.9W wall light
supply and Labour for fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc.Bollard light 12W
supply and Labour for fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc.Wall Exauhst 8inch 150 cfm
supply and Labour for fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc.Wall fan
supply and Labour for fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc.IP 65 Junction box suitable for 3 c x 2.5 sqmm copper cable
supply and Labour for fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc.Mirror Light
Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
Supply and installation of camera - 2MP Analog BULLET CCTV Camera, WITH 1080p Resolution, PoE Compatible, Indoor Type Camera 3.6mm lens, 20 mtr IR Range
Supply and installation of 32Channel NVR – Recording device - H.264 & Dual-stream video compression - With Min 200 MBPS Bandwidth, 2 SATA Support, Upto 5MP Camera Resolution Support, 25 FPS, Remote Access with Client Software CMS(Non POE Type)
Supply and installation of Switch for IP CCTV- 24Port Gigabyte POE Switch - Compatible with IP PoE CCTV Cameras - With 1/4 Fiber SFP Link Ports
Supply and installation of 4TB Surveillance Hard - Surveillance Special HDD / AV Series
Supply and installation of 6U Storage Rack with Power strip and tray
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Supply and Labour for Installation of Angle cock with wall flange
Supply and Labour for Installation of Health Faucet
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Supply and Labour for Installation of Angle cock with wall flange
Supply and Labour for Installation of Health Faucet
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: Range of three urinal basins with 10 litre white P.V.C. automatic flushing cistern
Supply and Labour for Installation of Angle cock with wall flange
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers
Supply and Labour for Installation of Angle cock with wall flange
Supply and Labour for Installation of PVC Bottle Trap
Supply and Labour for Installation of site 20mm dia C.P brass Concealed and Exposed part of Stop Cock [inside bathroom] including cutting and making good the wall wherever required (for drinking water/ cooler/ water-filtering units)
Supply and Labour for Installation of site 20mm dia Angle Valve including cutting and making good the wall wherever required
Supply and Labour for Installation of site 15mm dia C.P brass Bib tap/horse connector with wall flange including cutting and making good the wall wherever required
Supply and Labour for Installation,testing and commission of valves stated as follows with all supports,fixing and fitting alla as specified and shown on drawings and complying to relevent standards(ZOLOTO) 20mm dia section Brass Valve
Supply and Labour for Installation,testing and commission of valves stated as follows with all supports,fixing and fitting alla as specified and shown on drawings and complying to relevent standards(ZOLOTO) 25mm dia section Brass Valve
Supply and Labour for Installation,testing and commission of valves stated as follows with all supports,fixing and fitting alla as specified and shown on drawings and complying to relevent standards(ZOLOTO) 32mm dia section Brass Valve
Supply and Labour for Installation,testing and commission of valves stated as follows with all supports,fixing and fitting alla as specified and shown on drawings and complying to relevent standards(ZOLOTO) 32mm dia NR Valves
Supply and Labour for Installation,testing and commission of valves stated as follows with all supports,fixing and fitting alla as specified and shown on drawings and complying to relevent standards(ZOLOTO) 50mm dia Brass ball Valves
Supply and Labour for Installation,testing and commission of valves stated as follows with all supports,fixing and fitting alla as specified and shown on drawings and complying to relevent standards(ZOLOTO) 20mm ARV
Supply and Labour for Installation of Lead free PVC-U pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings.through floor,concrete etc. as required , replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand). Testing of the system for leakage and Air tightness (Supreme/Astral or equivalent) (4kg/cm2) 40mm OD Waste Piping
Supply and Labour for Installation of Lead free PVC-U pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings.through floor,concrete etc. as required , replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand). Testing of the system for leakage and Air tightness (Supreme/Astral or equivalent) (4kg/cm2) 75mm OD Waste Piping
Supply and Labour for Installation of Lead free PVC-U pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings.through floor,concrete etc. as required , replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand). Testing of the system for leakage and Air tightness (Supreme/Astral or equivalent) (4kg/cm2) 110mm OD Waste Piping
Supply and Labour for Installation of Lead free PVC-U pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings.through floor,concrete etc. as required , replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand). Testing of the system for leakage and Air tightness (Supreme/Astral or equivalent) (4kg/cm2) 50mm OD Soil Piping
Supply and Labour for Installation of Lead free PVC-U pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings.through floor,concrete etc. as required , replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand). Testing of the system for leakage and Air tightness (Supreme/Astral or equivalent) (4kg/cm2) 75mm OD Soil Piping
Supply and Labour for Installation of Lead free PVC-U pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings.through floor,concrete etc. as required , replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand). Testing of the system for leakage and Air tightness (Supreme/Astral or equivalent) (4kg/cm2) 110mm OD Soil Piping
Supply and Labour for Installation of Lead free PVC-U pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings. Ts, Elbows, Bends, Ysetc.. Adapters, Airvents, Clamping with GI U Clamps /supports, as required for firmliy installing the pipes and adjesent to the building/chasing the walls, concrete etc. as required, replastering and refinishing using cement plaster 1:3 mix ( cement : coarse sand). Testing of the system for leakage and Air tightness (Supreme/Astral or equivalent) (4kg/cm2) 110mm Rain Water Piping
Supply and Labour for Installation of Lead free UPVC SWR Type B pasted pipe using Solvent Cement ISI Marked [As per IS 13592] with Heavy duty ISI Marked PVC fittings through trench having upto a depth of 1mtr /as per site condition and to make corresponding slope hence complete. [Excavation will be in the scope of contractor]. Testing of the system for leakage and Air tightness (Supreme/Astral or equivalent) 160mmOD Rain water piping
Supply and Labour for Installation of Lead free UPVC SWR Type B pasted pipe using Solvent Cement ISI Marked [As per IS 13592] with Heavy duty ISI Marked PVC fittings through trench having upto a depth of 1mtr /as per site condition and to make corresponding slope hence complete. [Excavation will be in the scope of contractor]. Testing of the system for leakage and Air tightness (Supreme/Astral or equivalent) 160mmOD Rain water piping 110mm OD Waste Piping
Supply and Labour for Installation of Lead free UPVC SWR Type B pasted pipe using Solvent Cement ISI Marked [As per IS 13592] with Heavy duty ISI Marked PVC fittings through trench having upto a depth of 1mtr /as per site condition and to make corresponding slope hence complete. [Excavation will be in the scope of contractor]. Testing of the system for leakage and Air tightness (Supreme/Astral or equivalent) 160mmOD Rain water piping 110mm OD Soil Piping
Supply and Labour for Installing at site UPVC multi inlet traps and outlet connections to pipes using solvent cement complete as required for floor drains. (Supreme/Astral or equivalent) Multi Inlet floor trap 110x75x50/40mm.
Supply and Labour for Installing at site UPVC multi inlet traps and outlet connections to pipes using solvent cement complete as required for floor drains. (Supreme/Astral or equivalent) Supply and Installation of 125x125mm CP Stainless Steel Gratings with Cockroach Protection for multi inlet floor trap.
Supply and Labour for Installing at site Open UPVC Lead Free ASTM Schedule 40 Pipes (Equivalent Standard Size) with all accessories like bends,y's etc for Water supply Joined using Solvent Cement fittings suitable for the working pressure. Supporting exposed pipes using cement mortar at 60 cm intervals above terrace floor. Hydrostatic Testing of the Pipes using 10KG/cm2 test pressure for specified time period (Supreme/Astral or equivalent) 32mm Nominal Dia ASTM
Supply and Labour for Installing at site Concealed/open UPVC ASTM Schedule 40 Pipe of Equivalent Standard Size with all accessories like bends,y's etc for Water supply Joined using Solvent Cement fittings with metal inserts suitable for the working pressure. Inside walls, ceiling, concrete... etc. using GI clamps/supports as required, Hydrostatic Testing of the Pipes using 10kg/cm2 test pressure for specified time period (Supreme/Astral or equivalent) (including return pipes) 20mm Nominal Dia
Supply and Labour for Installing at site Concealed/open UPVC ASTM Schedule 40 Pipe of Equivalent Standard Size with all accessories like bends,y's etc for Water supply Joined using Solvent Cement fittings with metal inserts suitable for the working pressure. Inside walls, ceiling, concrete... etc. using GI clamps/supports as required, Hydrostatic Testing of the Pipes using 10kg/cm2 test pressure for specified time period (Supreme/Astral or equivalent) (including return pipes) 25mm Nominal Dia
Supply and Labour for Installing at site Concealed/open UPVC ASTM Schedule 40 Pipe of Equivalent Standard Size with all accessories like bends,y's etc for Water supply Joined using Solvent Cement fittings with metal inserts suitable for the working pressure. Inside walls, ceiling, concrete... etc. using GI clamps/supports as required, Hydrostatic Testing of the Pipes using 10kg/cm2 test pressure for specified time period (Supreme/Astral or equivalent) (including return pipes) 32mm Nominal Dia
Supply and Labour for Installing at site Concealed/open UPVC ASTM Schedule 40 Pipe of Equivalent Standard Size with all accessories like bends,y's etc for Water supply Joined using Solvent Cement fittings with metal inserts suitable for the working pressure. Inside walls, ceiling, concrete... etc. using GI clamps/supports as required, Hydrostatic Testing of the Pipes using 10kg/cm2 test pressure for specified time period (Supreme/Astral or equivalent) (including return pipes) 50mm Nominal Dia
Supply and Labour for Installation at site Concealed/open UPVC ASTM Schedule 40 Pipes of Equivalent Standard Size with all accessories like bends,y's etc for Water supply Joined using Solvent Cement fittings with metal inserts suitable for the working pressure. Chasing of the walls/Supporting exposed pipes using rails at 60 cm intervals through through duct, concrete etc. as required, replastering and refinishing using Cement Plaster 1:3 mix [Cement : Coarse sand]. Hydrostatic Testing of the Pipes using 10kg/cm2 test pressure for specified time period (Supreme/Finolex/Astral or equivalent) 32mm Nominal Dia ASTM
MANHOLE & MH COVER Supply and Labour for Installation,testing and commissioning of PVC type Manholes, valvechamber, sandtrap etc.. with suitable PCC around it with fit and finish and including escavation,backfilling,disposel, waterproofing etc upto 1 mtr depth all in accordance with the drawing ,specification and relevant standards. and its Cover with suitable frame and accessories 355mm base with suitable riser 110mm IN and 110mm OUT Size(as per the site condition): 45 cm x 45 cm
Constructing Gully Trap Chamber 300X300mm internal size including 100mm thick 1:4:8 PCC base,120mm thick brick masonry in CM 1:5, plastering internally and externally with CM 1:3 and providing 110mm dia PVC Trap
MANHOLE COVER Supply and Labour for Installation ,testing & commisssioning of ISI marked FRP manhole cover and frame of (10 ton withstanding capacity) conforming to the latest relevant IS specifications. Make:Thermodrain Size(as per the site condition): 45 cm x 45 cm
MANHOLE COVER Supply and Labour for Installation ,testing & commisssioning of ISI marked FRP manhole cover and frame of (10 ton withstanding capacity) conforming to the latest relevant IS specifications. Make:Thermodrain Size(as per the site condition): Size(as per the site condition): 30 cm x 30 cm
Supply and Labour for Installation of Robe Hook
Supply and Labour for Installation of Soap Dish
Supply and Labour for Installation of Tumbler Holder
Supplying, installation, testing and commissioning of factory fitted electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required: (a) Horizontal type, centrifugal, end suction pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
Supplying, installation, testing and commissioning of factory fitted electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required: b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump).Horizontal type, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads.Diesel engine driven end suction Pump (2280 LPM at 55 m head)including MS fabricated common base plate, coupling, coupling guard.
Antivibration mounts
180 AH Battery
Batery Leads
100 Ltr Diesel Tank
Coolant
Diesel Filter
Supplying, installation, testing and commissioning of electric driven Jockey pump with centrifugal vertical inline multistage pump having cast iron base with flanged connection and SS 304 impeller, mechanical seals and electric motor. suitable for automatic operation and consisting of following, complete in all respects, as required. The pump motor shall be TEFC IP55 squirrel cage induction motor having efficiency class IE2 (as per IS 12615/IEC 60034) with class 'F' insulation, 2900 RPM synchronous speed, operating on 415 V +/- 10%, 3 phase, 50 Hz AC +/- 5% supply. Locally assembled sets (outside the manufacturer's premises) are not acceptable. Vertical inline multisatge Pump (180 LPM at 75m head)
Supplying, installation, testing and commissioning of electric driven Jockey pump with centrifugal vertical inline multistage pump having cast iron base with flanged connection and SS 304 impeller, mechanical seals and electric motor. suitable for automatic operation and consisting of following, complete in all respects, as required. The pump motor shall be TEFC IP55 squirrel cage induction motor having efficiency class IE2 (as per IS 12615/IEC 60034) with class 'F' insulation, 2900 RPM synchronous speed, operating on 415 V +/- 10%, 3 phase, 50 Hz AC +/- 5% supply. Locally assembled sets (outside the manufacturer's premises) are not acceptable. Antivibration Mounts
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump).Horizontal type, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation,conforming to IS-325. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. Electric driven end suction Pump (900 LPM at 35 m head)including MS fabricated common base plate, coupling, coupling guard.
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump).Horizontal type, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation,conforming to IS-325. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.Antivibration Mounts
Supplying and fixing air vessel made of 200 mm dia, 6 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal Ball valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.(Fabricated Type)
Supply,Installation, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 200 mm dia
Supply,Installation, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 150 mm dia
Supply,Installation, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm dia
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. Below Ground Piping 150 mm dia
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. Below Ground Piping 100 mm dia
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. Below Ground Piping 80 mm dia
Providing laying, testing & commissioning of 'B' class medium duty M.S Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground/below ground/suspended including welding, supports, anticorrosive treatment with coal tar/asphalt tape as per IS 10221, etc. of following sizes complete as required. DIESEL ENGINE EXHAUST PIPE 80 mm Dia
Providing, laying of 75 mm thick mineral wool insulation (150 Kg per cubic meter density) on diesel engine exhaust pipe and silencer with chicken mesh wrapping and aluminum cladding with aluminum sheet of 26 SWG, complete as required and as per specification and IS
CONNECTIONS TO WATER TANKS-PUDDLE FLANGE Allow for GI pipe work and fittings in the water tank including puddle flanges all in accordance with the drawings and specifications.( underground and overhead tanks ) 200mm dia (75cm)
CONNECTIONS TO WATER TANKS-PUDDLE FLANGE Allow for GI pipe work and fittings in the water tank including puddle flanges all in accordance with the drawings and specifications.( underground and overhead tanks ) 150mm dia (75cm)
BREACHING INLET ASSEMBLY Supply, installation, testing and commissioning of 4-WAY FIRE BRIGADE inlet connection made of CI Body, 150mm dia. flanged inlet with 4 Nos. of inbuilt gunmetal, NRV (Body type) with PVC Blank cap , Chain complete with GI nuts, bolts, gasket etc as required as per technical specification.
TANK FILLING INLET Supply, installation, testing and commissioning of 4-WAY TANK FILLING INLET connection made of CI Body, 150mm dia. flanged inlet with 4 Nos. of inbuilt gunmetal, NRV (Body type) with PVC Blank cap , Chain complete with GI nuts, bolts, gasket etc as required as per technical specification.
DRAW OUT CONNECTION Supply, installation, testing and commissioning of draw out connection with CI body and gunmetal coupling, complete with GI nuts, bolts, gasket etc as required as per technical specification.
BUTTERFLY VALVES Supply, Installation, Testing and Commissioning of PN 1.6 (16 Kg/Sq.CM) rated wafer type Butterfly Valves of the following sizes. Valves shall be provided with Black Nitrile rubber integrally moulded onto the body as body seat, Nylon coated SG Iron disc with flow control lever, stainless steel disc & stem, conforming to IS 13095, with ISI mark. 150mm dia
BUTTERFLY VALVES Supply, Installation, Testing and Commissioning of PN 1.6 (16 Kg/Sq.CM) rated wafer type Butterfly Valves of the following sizes. Valves shall be provided with Black Nitrile rubber integrally moulded onto the body as body seat, Nylon coated SG Iron disc with flow control lever, stainless steel disc & stem, conforming to IS 13095, with ISI mark. 100mm dia
BUTTERFLY VALVES Supply, Installation, Testing and Commissioning of PN 1.6 (16 Kg/Sq.CM) rated wafer type Butterfly Valves of the following sizes. Valves shall be provided with Black Nitrile rubber integrally moulded onto the body as body seat, Nylon coated SG Iron disc with flow control lever, stainless steel disc & stem, conforming to IS 13095, with ISI mark. 80mm dia
NON-RETURN VALVES Supply, Installation, testing and commissioning of Dual Plate type Non Return Valves as per API594 PN16 wafer type, SS Disc with required flanges,nuts,bolts,washers,gaskets etc., complete as required. 150 mm Dia
NON-RETURN VALVES Supply, Installation, testing and commissioning of Dual Plate type Non Return Valves as per API594 PN16 wafer type, SS Disc with required flanges,nuts,bolts,washers,gaskets etc., complete as required. 80 mm Dia
Y-STRAINER VALVES Supply, installation, testing and commissioning of Y strainer with Cast iron/Carbon steel body, SS mesh complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification. 150mm dia
Supply & installation of Pressure Gauge with 0-300 psi (0-21Kg/Sq.CM) range white background, black graduation scale with dual reading in Kg/Sq.CM & PSI, 1/4" BSPT bottom entry PHOSPHOROUS BRONZE bourden tube, brass moving parts, polished stainless steel case with positive seal against weather,moisture & dust, hardened glass, Glycerine filled type with syphon tube and isolation cock.
AUTO AIR VENTS - SITC of automatic purge valves at the highest points and strategic locations of chilled water piping complete with fittings and accessories as required and specified -25mm Dia.
Supply, Installation, testing and commissioning of Industrial type SPDT pressure switch with inlet connection of 1/4 " BSP(F) phosphor bronze bellows, suitable to operate AC/DC supply of 110-380 /24-250 v respectively with current rating of 6A inductive/10A resistive for maximum pressure of 230 psi including providing isolation cock. (control cabling from the pressure switch to panel, termination of cable etc are in the scope of electrical contractor)
Supply, Installation, testing & commissioning of resilient rubber lined single arch vibration eliminator connection (Expansion Bellow) with unit control suitable for water up to 45oC temperature, working pressure 10.00 Kg/cm2 and test pressure 15.00 Kg/cm2 150mm dia
Supply, Installation, testing & commissioning of resilient rubber lined single arch vibration eliminator connection (Expansion Bellow) with unit control suitable for water up to 45oC temperature, working pressure 10.00 Kg/cm2 and test pressure 15.00 Kg/cm2 80mm dia
Supply, Installation, testing and commissioning of Cast Iron flanged Sluice valve as per IS 14846,Flanged to BS5163, PN16, with required flanges, rubber insertions, bolts, nuts, Washers etc. complete.150 mm dia
Supply, Installation, testing and commissioning of forged brass Ball valve with forged brass ball suitable for operating pressure of not less than 16 kg / sq.cm. 25 mm dia
Supply, Installation, testing and commissioning of forged brass Ball valve with forged brass ball suitable for operating pressure of not less than 16 kg / sq.cm. 20 mm dia
Supply, Installation, testing and commissioning of Stainless Steel flanged Ball type Foot valve,Y type pattern,PN 16 as per IS 4038. 100 mm dia
Supplying and fixing single headed internal hydrant valve with instantaneous Gun Metal coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank stainless steel cap and chain as required
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings,Stainless Steel (Grade 304) duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
Supplying & fixing 63 mm dia stainless steel short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
Supplying and fixing first aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 & 30m long, 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipment on wall. Connections from riser with M.S. Pipe and socket .
Supply & Installation of Hose Cabinets to accommodate two piece of hose pipe along with one pair of male and female coupling and one branch pipe. The cabinet is with double door and glass fronted hinged doors and lock, powder coated to PO red colour. Locking arrangements of the cabinets shall be provided in the front side of the box with a glass covering to access easily.Stainless Steel
Supply, erection, testing & commissioning of Fire extinguishers & Accessories all in accordance with the drawings and specifications. 4.5 KG CO2 fire extinguishers
Supply, erection, testing & commissioning of Fire extinguishers & Accessories all in accordance with the drawings and specifications. 4Kg Dry Chemical Powder extinguisher(MAP 90)
Providing and installation in position 1 x 6W, 240 V, 1 ph, 50 Hz indoor type emergency exit light fixture with 1.3 AH 4hrs battery back up unit, LED Lamps, indicating Fire Exit, recess mounted type. 24hrs x 7days working conditional and shall be as per IS code 9457:2005, IS 12349, IS 12407.
Making of openings in structural (RCC) walls / slabs of 10cm thick for passage of pipes / cables using suitable core cutting machinery for the following sizes . 100mm dia opening
Making of openings in structural (RCC) walls / slabs of 10cm thick for passage of pipes / cables using suitable core cutting machinery for the following sizes . 125mm dia opening
Making of openings in structural (RCC) walls / slabs of 10cm thick for passage of pipes / cables using suitable core cutting machinery for the following sizes . 160mm dia opening
FIRE ALARM PANEL: Supply, installing, testing and commissioning of Micro processor based Main Fire alarm control panel of 2 zones capacity, with visual LED indications for fire / fault alarms, signals and should have stage alarm facility with maintenance free The panel shall be fabricated by M.S. sheet and powder coated both inside & out side, door shall be glass fronted type with locking arrangement, as per specification. Make : Ravel
MANNUAL CALL POINT: Supply, Installation, testing and commissioning of Manual Call Point ABS type as per standrad specification. Make : Ravel
ELECTRONIC ALARMING HOOTER:Supply, installation, testing and commissioning of Electronic Hooter (Sounder) as per standard specification. Make : Ravel
FIRE ALARM CABLE:Supply and laying of PVC insulated 1sq mm copper fire alarm cable Make:V-Guard/Polycab/Havells.
PVC CONDUIT:Supply and laying of 20mmPVC rigid conduit with fixing material Make: ISI Marked
Supplying, installation, testing and commissioning of factory fitted electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required: (a) Horizontal type, centrifugal, end suction pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c)M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. e)Suitable cement concrete foundation duly plastered with anti vibration pads.Electric driven end suction Pump (2280 LPM at 70 m head)including MS fabricated common base plate, coupling, coupling guard.
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump).Horizontal type, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. Diesel engine driven end suction Pump (2280 LPM at 70 m head)including MS fabricated common base plate, coupling, coupling guard.
Supplying, installation, testing and commissioning of electric driven Jockey pump with centrifugal vertical inline multistage pump having cast iron base with flanged connection and SS 304 impeller, mechanical seals and electric motor. suitable for automatic operation and consisting of following, complete in all respects, as required. The pump motor shall be TEFC IP55 squirrel cage induction motor having efficiency class IE2 (as per IS 12615/IEC 60034) with class 'F' insulation, 2900 RPM synchronous speed, operating on 415 V +/- 10%, 3 phase, 50 Hz AC +/- 5% supply. Locally assembled sets (outside the manufacturer's premises) are not acceptable. Vertical inline multisatge Pump (180 LPM at 85m head)
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump).Horizontal type, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation,conforming to IS-325. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.
Providing and fixing N.H./ S.H. Route Marker size 60 cm x 45 cm with one No. direction plate of size 30 cm x 25 cm prepared on 16 guage Alluminium sheet including Type IV High Intensity Micro-Prismatic Grade Sheeting (HIP) having pressure sensitive / heat activated adhesive, IRC Specified colour retro reflective cutout border & messages having pressure sensitive adhesive having border & messages in IRC Specified colour background, including one One Number of M.S. Angle iron post of size 50 x 50 x 5 mm of 3.65 m. long inflated at bottom drilled on top in one piece without joint painted with white and black bands of 30 cm. fixing board and post with 4 Nos. of high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long including all taxes, conveying, fixing in ground with cement concrete 1:4:8 block of 60 cm x 60 cm x 75 cm size as directed by Engineer-in-charge etc. complete. Alluminium sheet Type IV High Intensity Micro-Prismatic Grade Sheeting
Braille Signage at Entrances (300×300)
Audio Signage / PA units
Tactile Pathway Guidance Maps (raised)
Accessible Toilet / Feeding Room signage (tactile)
History Boards of Ghats (premium 900×600)
Supply and fixing of Linear LED Wall Washer, 36–48 W, RGBW, IP66 aluminium body, DMX-compatible driver, complete with brackets and connection accessories as required.
Supply and fixing of Underwater LED Luminaire, 18–36 W RGBW, IP68, SS316 body, toughened glass cover, including waterproof gland, mounting clamp, and termination.
Supply and fixing of Recessed Step Light, 6–12 W warm white, IP67, aluminium housing with toughened front glass, including recessed box and all accessories.
Supply and fixing of Bollard Light, 20 W LED, IP66, 1 m height, powder-coated body with foundation bolts and internal driver complete in all respects.
Supply and fixing of Architectural Floodlight, 50–100 W RGBW, IP66, DMX controllable, die-cast aluminium housing with mounting bracket and accessories.
Supply and fixing of Façade Downlight, 15–25 W warm white, IP65, recessed / surface type as required, complete with driver and mounting accessories.
Supply and fixing of Spike / Garden Focus Light, 10–15 W warm white, IP66, powder-coated aluminium body with adjustable spike and connection accessories.
Supply and fixing of Flexible RGBW LED Strip, IP67, 12–24 V DC, installed in aluminium channel with diffuser, end caps and driver.
Supply and fixing of Signature Dynamic Feature, programmable RGB pixel array / fountain module with DMX controller, SS housing, drivers, cabling and mounting.
Supply and fixing of Signature Dynamic Feature, programmable RGB pixel array / fountain module with DMX controller, SS housing, drivers, cabling and mounting.
Supplying, installation, testing and commissioning of factory fitted electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required: (a) Horizontal type, centrifugal, end suction pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c)M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. e)Suitable cement concrete foundation duly plastered with anti vibration pads.Electric driven end suction Pump (2280 LPM at 70 m head)including MS fabricated common base plate, coupling, coupling guard.
Royalty Charges as per Revenue and Forest Department's notification dated 11/02/2010 as Maharashtra Minor Mineral Extraction Rules, 2010 and as per insruction in general notes on State Schedule Rates 2022-2023 in Public Works Sanctioned schedule of rates for year 2022-2023 for items of lime stone, lime shell, stones, rubble, stone dust, shingles, gravel, murum, kankar, ordinary clay, ordinary earth (to be used for embankment and filling), slate and shell etc. Spec. No.: As directed by Engineer-in-charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
technical_2175208.pdf
techsummary_2175208.pdf
finance_2175208.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.47 MB
RFP.pdf
Tender Documents • 3.46 MB
LAXMINARAYANTEMPLEMASTERPLAN.pdf
Tender Documents • 0.55 MB
SOMESWARWATERFALLMASTER.pdf
Tender Documents • 3.41 MB
VOLUME2NAVSHYAGANPATIMANDIR.pdf
Tender Documents • 29.93 MB
VOLUME2SOMESWARWATERFALL1.pdf
Tender Documents • 33.52 MB
BOQ_2175208.xls
BOQ • 0.58 MB
VOLUME2LAXMINARYANTEMPLE.pdf
Tender Documents • 37.17 MB
NAVSHYAGANAPATIMANDIRMASTERPLAN.pdf
Tender Documents • 1.41 MB
Download all tender documents and submit your bid