Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.3 LAccepted-AOC 1108 CHOTA BAZAR MHOW MP PIN 453441 | MHOW | INDORE | MADHYA PRADESH | 453441 | L1 | Accepted-AOC Lowest and reasonable | |
| 2 | L2₹31.0 L+₹69,704.10 (2.30%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹31.4 L+₹1.1 L (3.67%)Rejected-Finance 84 A VIJAY NAGAR COLONY LALGHATI PO NAYAPURA BHOPAL 462032 | 462032 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹31.4 L+₹1.2 L (3.86%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹38.3 L+₹8.0 L (26.5%)Rejected-Finance 21 PASCHIM VIHAR EXTENSION NEW DELHI 110 063 | NEW DELHI | NEW DELHI | DELHI | 110063 | L5 | Rejected-Finance Being L5 |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
3 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Mhow
HQ CWE Mhow Cantt Mhow Pin 453441
PROVN OF ADDL POWER SUPPLY OF 315 KVA FOR ATC FOR NFS NODE UNDER GE MCTE MHOW
2020_MES_353702_3
CA No CWE/Mhow/06(T) OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
HQ CWE Mhow
Please refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE MCTE Mhow
₹64,000
Yes
31 Dec 2020
31 Aug 2020
5 Nov 2020
31 Aug 2020
3 Nov 2020
8 Sept 2020
60 days
Amount
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in deep and getting out for laying of cable/ pipes etc including forming bottom surfaces to the required level/slope complete all as specified and directed
Returning , filling in includiing spreading levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil comlete all as specified and directed
Removing surplus excavated to a distance not exc 50 mtr and depositing where directed at level not exc 1.5mtr above the starting point complete allas specified and directed.
Material and labour for approved river sand cushioning for under ground cable in trenches 8 cm before laying and 15cm after laying of cable and punned thickness of sand shall be measured and paid for 18 cm only after punned /consolidated thickness complete all as specified and directed
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type-1, flat, size 300mm x 180mm x 40mm, ISI marked, laid flat across the cable length complete all as specified and directed. (Make: Mahtab tiles / Alankar Tiles/Pearlers Industries/SIND Mozaic Gujrat/JJ Concrete Lucknow).
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type-1, flat, size 250 mm x 150mm x 40mm, ISI marked, laid flat across the cable length complete all as specified and directed. Make: Mahtab tiles / Alankar Tiles/Pearlers Industries/SIND Mozaic Gujrat/JJ Concrete Lucknow.
Supply and laying GI pipe “Light Grade” size 100 mm bore in trenches, under floors, roads, along poles for protection of cables, including sealing ends all as specified & directed.
Supply, installing, testing and comissioning AC 3 Phase 50Hz, 315 KVA capacity transformer copper wound step down transformer out door type 11000/433 Volts (at no load) double wound oil immersed naturally cooled with external Cooling Tube, core type delta connected on primary side (HV) and star connected on secondary side (LV) and have in tapping at +/- 2.5 % +/-5.0% and +/- 7.5% to be changed by means of hand operated off load tap changing gear the maximum temperature rise should not exceed 45 degree centigrade in oil and 55 degree centigrade in HV/LV winding when measured by resistance method after continuous full load run in ambient temp of 40 degree centigrade and the transformer bushing on HT side and LT side all as per IS 1180 of 2014 efficiency level-3, impedence 4.5% standared losses for 50% load-955 watt and 100% load 2750 watt complete all as specified and shall be comprising following accessories and the transformer shall be comprised with the following standared fittings:-
(a) Three Nos porcelain Bushings HT 11 KV with copper bushing with copper rod nuts and washers inside cable and including end box. (b) One cable box LV side consisting of four nos porcelain bushing with copper rod complete with nuts and washer including box HV side. (c) Oil Conservator with filter type drain valve and oil level gauge. (d) Dehydrating breather with first fill dehydrating agent (Silica Gel) (e) Explosive vent. (f) Thermometer Pocket on tank cover having maximum temperature indication with resisting device for transformer. (g) Rating plate and terminal marking plate. (h) The earthing terminal two nos to facilitate fixing of earth strip. (j) Oil filling hole with cap/plug with connection plate complete. (k) Air relief valve plug. (l) Initial filling to transformer oil. Note : i)Testing of transformer to be carried out by officer detailled by accepting officer before despatch from factory site. ii) Base for mounting of transformer made out of bricks 2mtrx2mtrx2mtr incl plaster is quoted in the above item rate.
Supply, installation ,testing and commissioning of 11 KV, 630 Amps, Non extensible, Outdoor, 3 way RMU Panel with 2 Isolators & 1 VCB, SF6 insulated, 11 kv Ring Main Unit contained within Robotically welded 3mm thick Stainless Steel Tank for main tank & 2mm GI sheet for outer enclosure suitable for outdoor use (without kiosk) free standing type tested for internal arc test for IAC AFL for 21KA for !sec. and comprising of :-
1) 1 No.- 630 Amp triple pole, manually operatoted vacuum ciruit breaker encapsulated in SF6 Stainless steel tamk with independent spring mechanism and fuly rated earth switch with provision for earth of the cable. 2) 1 No.- Air insulated cable boxes with split gland plate suitable for front side bottom entry 3 core cable up to 300 sq. mm for out goings. 3) 2 Nos.- 630 Amp triple pole, single break, 3-postion ('ON', 'OFF'and "EARTH') ring main switches, each with independent mannual charged spring mechanism and fully rated earth switch, with provision for earth and test of the cable. 4) 2 Nos. Air insulated cable boxes and glands suitable for front and bottom cable entry 3-core up to 300 sq mm for incomings. The Ring Main Unit should comprise of the following accessories: a) 1 Mimic diagram on front panel complete with status indicators.
t) 3 sets of right angel boots. u) Paint finish - All steel work will be finish painted in Dark grey shaded 632 as per IS v) 2Nos. of epoxy moulded Trip Coil with the Vaccum Circuit Breaket for Protection purpose. RMU Pannel should have following general characteristics :- (i) Enclosure degree of prtection -IP54 (ii) Type of Ventialtion -Natural (iii) Rated Enclosure class - K10 (iv) Rated power frequency withstand -28/38 kv Voltage KV rms,min (v) Rated lighting impulse withsatnd - 75/95 kv Voltage kv, 1.2/50 micro sec (vi) Short time current rating ka, for sec -20 kA/ 3sec (vii) Rated short ckt making current - 50kA (viii) Reference standard - IEC62271-202 MAKE : SIEMENS / SCHENIDER / ABB / LUCY ELECTRIC INDIA NOTE - Nacessary drwing shall be got approved before placing order and PDI including testing shall be carried out by the rep of accepting officer. The cost of PCC platform for mounting RMU Pannel as per manufacturers instruction are deemed to be including in the quoted rate.
Supply, fix, testing and commissioning of outdoor microprocessor based APFC Panel capacity 100 KVAR comprising of heavey duty gas filled capacitors and suitable capacity incommer MCCB and branch protection MCB with auto manual switching complete of following specifications :
(a) Power rating :100 KVAR. (b) Power supply : 3 phase 4 wire line. (c) Rated system voltage : 440 volts. (d) Rated frequency : 50 Hz. (e) Short circuit rating : > 25 KA. (f) Duty : continuous. (g) Ambient Temp : (-)5*C to 45*C (h) 3 Relay current input signal : 200/5A from CT on line. (i) Enclosures : load bearing structure, bottom, top, all three sides and front door made out of 3.00 mm thich CRCA sheet, powder coated, all partition made of 2.00mm thich CRCA sheet. The internal componants are accessible on opening the front door Ingress Protection : IP-54 (j) Capacitors : Heavy duty cylindrical gas filled capacitors (MPPH). 10kVAr -10 Nos (k) Switching device (Contactors) : Capacitor duty Three pole MPX dequate rating for respective steps. (l) Branch protection : MCCBs for providing short circuit protection and control. (m) Step Size : 10x10KVAR. (n) Step : 10
(c) APFC Panel manufacturers should have CPRI approved certificates type tested for Short Circuit Rating not less than 50 Kilo Amps 4000Amps (d ) Panel manufacturers should have inhouse powder coating plant with minimum 8 tanks pre treatment of MS sheet facilities, dust free spray paint booth . [ 8 Tanks pre treatment process includes : Degreasing / Water Rinsing / Derusting / Water Rinsing / Activation / Phosphating / Water Rinsing / Passivation]. (e) Thickness of powder coating shall not be less than 80 microns and test certificate for powder coating shall be furnished along with the APFC Panel. (f) Post fabrication inspection shall be carried out by the authorised rep of Accepting officer before powder coating. If found any deviation from approved drawing ,shall be corrected without any extra cost. (g) Pre despatch Inspection and testing shall be done at manufactur's premises and all routine test like IR and continuity tests sall be performed /recorded in presence of authorised rep of Accepting officer. (h) All Power connections shall be done with suitable size of Aluminum armoured 3.5 Core Cable and 3 Phase CT sensing connections shall be done through copper armoured 1.5 sqmm cables.
Supply, laying in trenches/through pipes under road, floor/ on wall/on pole or any other indicated place & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored earth, electric power cables (heavy duty)with stranded aluminum conductor, 11000 volts grade, of size 3 core 70 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 70 sq mm all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 70 sq mm all as specified and directed.
Sppply & Laying LT XLPE insulated,400 Sqmm 3.5 core, armoured, electric cable with aluminium conductor, 1100 volts grade, laid in trenches, fixed on poles / walls or passing through pipes including lugs, glands & making necessary connection complete all as specified and directed.
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts outdoor type Confirming to IP 43, CPRI approved, fabricated & assembled ,free standing, floor mounting, water proof,dust and vermin proof cubical type, LT Panel fabricated from 3.15 mm thick ( minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), fully compartmentalized design with busbars made of aluminium duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours. Bus bar shell be properly supported/mounted on epoxy insulators.All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for connecting suitable earth strips and both side openable doors shall be provided of all operational switchgear and MCCBs and detchable cover shall be provided on all other accessories.Panel shall be manufactured suitable for housing as the following :-
Incoming :- (a) Aluminium bus bar - 800 amps rating - 03 Nos. for phases and 300 amp rating - 01 No. for neutral. (b) MCCB 4 pole 630 Amp,50 KA, 415 volt - 01 No (Incommer). (c) Digital Ammeter/Voltmeter 0 to 500 A, 0-500 V . (d) ON/OFF LED type indication lamp with toggle switch - Set of 03. Outgoing :- (a) MCCB 4 pole 250 Amp, 415 volt, 37 KA - 02 No. (b) MCCB 4 pole 100 Amp, 415 volt, 37 KA - 02 No.
M & L for earthing complete with galvanised steel earth plate 600mm x 600mm x 6mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised MS strip 32 X 6 mm as earthing strip by means of bolts, nuts, check nut and washers of galvanised iron or steel at all joints as shown in Electrical Plate No-3 of SSR Part I including excavation and earth work in any type of soil, GI pipe 15 mm dia light grade protection pipe, chorcoal filling, common salt, PCC 1:3:6 type C-1 using 20 mm graded stone aggregate in chamber and RCC precast cover 60mm thick (1:2:4) type B-1 using 20mm dia graded crushed stone aggregate, reinforced with 8mm to steel bars @ 75 mm c/c both ways with MS handle 12mm dia, GI funnel and wire mesh, 20mm dia GI pipe medium grade for watering and connected to earth Test point including testing complete all as specified and directed.
JAZZCON ENGINEERS PVT LTD
POONAM ELECTRIC INDUSTRY
AGARWAL BUILDERS
M/s R. K. Bhambri
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .