Loading…
Loading…
Tender Value
₹6.2 Cr
EMD Value
₹6.2 L
Closing Date
1 Sept 2026, 5:30 pm
MS PRIYANKA SHARMA(DFLT)
CHIEF ENGINEER ( TENDER CELL)
NIT 1176 Renewal / Strengthening Road Under MMGSVY PKG No MMGSY-RGH-M-08 District-Raigarh
197785
NIT 1176 Renewal / Strengthening Road Under MMGSVY PKG No MMGSY-RGH-M-08 District-Raigarh
RESTRICTED TENDER
WORKS
PERCENTAGE
6 days
CHIEF ENGINEER ( TENDER CELL)
Required Past Technical Experience: As per Tender document
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
15 documents required · 15 mandatory
Panchayat and Rural Development (PARD)
WORKS
MS PRIYANKA SHARMA(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B
CHIEF ENGINEER ( TENDER CELL)
TENDER CELL
CGRRDA RAIPUR
120
06
No
1
197785
1 Sep, 2026 5:30:00 PM IST
3 Sep, 2026 5:40:46 PM IST
17 Aug, 2026 5:30:00 PM IST
NIT 1176 Renewal / Strengthening Road Under MMGSVY PKG No MMGSY-RGH-M-08 District-Raigarh
NIT 1176 Renewal / Strengthening Road Under MMGSVY PKG No MMGSY-RGH-M-08 District-Raigarh
622000.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
62166000.00
2
3 Sep, 2026 5:30:54 PM IST
62166000
AS PER NIT
AS PER NIT
As per Tender document
5000.00 INR
14d 23h 26m
15 documents required · 15 mandatory
₹5,000
₹6.2 L
17 Aug 2026
17 Aug 2026
3 Sept 2026
17 Aug 2026
3 Sept 2026
Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth up to 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. In area of non-thorny jungle
Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. (B) Cement Concrete
Restoration of Rain Cuts Restoration of rain cuts with soil, moorum gravel or a mixture of these , clearing the loose soil , benching for 300 mm width laying fresh material in layers not exceeding 250 mm and compaction with plate compactor or power rammer to restore the original alingement , level and slopes as per drawings and techinical specification Clause 1902
Surface drain in soil- Construction of unlined surface drains of average cross section 0.4 sqm in soil
Scarifying Existing Granular bituminous Surface to a Depth of 100 mmScarifying existing granular/bituminous surface upto a depth of 100 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.
(a) Construction of subgrade and earthen shoulders with approved material (Granular material having CBR not less than 7) obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Clause 303.1.For Item No.3.12(a) & (b
Granular Sub-base with Well Graded Material (CBR 20 or more) (Table 400.1) using motor grader and vibratory roller. (a) Construction of granular sub-base by providing well graded material having CBR 20 or more, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory rollers of 80 to 100KN static weight to achieve the desired density, complete as per Technical Specification Clause 401. For Gradingmentioned in table 400.1 (Grading III)
Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406.
Construction of subgrade and earthen shoulders with approved material (Granular material having CBR not less than 10) obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Clause 303.1.
Cement Concrete Pavement (ii) Construction of un-reinforced, jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 Cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including leveling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying, primer, sealant, Using curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501.
Prime coat1 with low porosity:--Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70- 1.0 kg/sqm using mechanical means as per Technical Specification Clause 502..
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.
Bituminous Macadam Providing and laying bituminous macadam with hot mix plant using crushed aggregates of grading as per Table 500.4 premixed with bituminous binder, transported to site laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled to achieve the desired compaction as per Technical Specification Clause 504.
20mm thick Open-Graded Premix Carpet using Bituminous (VG/modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of aggregate 13.2mm size (passing 22.4mm size sieve & retained on 11.2mm sieve and 11.2mm size (passing 13.2mm sieve and retained on 5.6mm sieve) either using penetration grade/ VG bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508., Viscocity grade (VG) Bitumen specification as per IS 73:2006
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510, Viscocity grade (VG) Bitumen specification as per IS 73:2006
Mix Seal Surfacing Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509, Viscocity grade (VG) Bitumen specification as per IS 73:2006
Construction of Panel concrete, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade) coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed a in a concrete mixer of not less than 0.2 Cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including leveling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibratos and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, admixture as approved, curing of concrete slabs for 14 days. Curing compound (where specified) and water finishing to lines and grade as per drawing and technical specification Clause 1501. PCC Grade M-30 Each Panel (0.50 x 0.50) thickness 100 mm.
Earthwork in excavation for structuresas per drawing and technical specifications Clause 305.1 including seting out, construction of shoring and bracing, removal of stumps and othar deletercus material and dis posal upto a lead of 50m dressing of sides
(II) Ordinary rock (not requiring blasting) i. Upto 3 m depth
Providing and laying reinforced cement concrete pipe NP3 for Culverts/ Burried conduits on first class bedding of granular material including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets as per Clause 1106. 600mm dia
Bedding for Causeway / pipes Type B (First Class) Bedding Laying (First Class) bedding on well compacted sand, moorum or approved granular material as per Clause 1105
Laying Reinforced Cement Concrete Pipe NP3 as per drawing and technical specification Clause 1402.6 Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.(B)1000 mm dia
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 For height upto 5 m (I)P.C.C grade M 15 (Nominal mix (1:2.5:5)
Providing weepholes in brick masonry/stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 Granular material
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5, (II) R.C.C M 25 (Design mix)
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans, covered with sealant complete as per drawing and technical specifications
Providing and fillling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight.
Cautionary, mandatory, informatory direction and place identification sign boards. Semi-Reflective Traffic signs upto 0.90 sqm Direction and place indentification
Providing and fixing LOGO BOARD as per MORD specification
Semi-Reflective Traffic signs more than 0.90 sqm sign board Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colo
Providing typical PMGSY informatory & Logo Board as per approved drawing& Specification ,painted with enamel paint on both side of board , lettering , figuring , printing arrows , borderr etc with ready mix synthetic enamel paint of superior quality in required shed & colours . (ii) PCC / RCC
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703
Reinforced cement concrete M15 grade Guard Stone of size 200 mm x 200mm x 800 mm fixing in position including painting and printing etc. as per drawing, Technical Specification and as per direction of Engineer in Charge.
Speed Braker (For 9.0 Mt Formation Width (5.50 carriage way width) Providing and laying rounded hump type of Speed Breaker confirming to IRC – 99 and as per guidelines and drawings of NRRDA circular no. DO No. P-17019/6/2006/PII Dated 16 Sept 2009, including providing, laying and compaction of GSB, G II, G III, OGPC, Seal Coat Type B, as per specifications and appended drawing on both the sides of carriage way up to formation width maintaining rounded hump type shape with bituminous mix material i/c providing and painting of black and white strips, providing and fixing of two no. 600mm equilateral semi reflecting sign boards, i/c cost of all materials, labour T & P & Machinery etc complete and as directed by engineer in charge as per relevant clauses of MORD specifications.
9.18 Road marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC: 35. The finished surface to be level, uniform and free from streaks and holes.) sqm 904.00
Total Cost
Executive Engineer
PIU -01 CGRRDA Raigarh
Dist Raigarh (C.G.)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.10 MB
5423138219147850775_153496_1278507194557121433_80616_Guidelines to Bidders.pdf
NIT • 0.13 MB
2567830620679678560_197785_NIT 1176 Tender Document MMGSVY Renewal Maintenance.pdf
NIT • 1.55 MB
1859371283756963533_197785_BOQ-RGH-M-08.xlsx
BOQ • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].