JGM(Proj)
TCIL Bhawan
Selection of Implementation Partner for balance work at IOCL terminal/Depot/BP namely Haldwani and Shahjahanpur for the project Design, Supply, Installation, Testing, Commissioning and CAMC of IP Based CCTV Surveillance System along with associated w
2026_TCIL_278806_1
TCIL/ITDT/2026/UPSO
Open Tender
Information Technology
84 days
Uttar Pardesh
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹5 L
Yes
26 May 2026
26 May 2026
16 Jun 2026
26 May 2026
15 Jun 2026
26 May 2026
Supply of hot dip GI earth strip ( 50 X 6) within earth station. Hot dip galvanizing (800 gm/m2 as per IS 4759) shall be done after all fabrication.
Supply of 50 mm HDPE pipe of minimum 2.5 mm thick along with accessories as per tender specifications and instructions of Engineer in charge.
Cable tray cover -RMG
Description
Installation, erection & foundation of Heavy Duty self supported Hot Dip Galvanized Poles for mounting of CCTV cameras along with civil foundation along with GI foundation bolt, mounting brackets, ladder arrangement (taking into account of safety during climbing) on the pole for installation and maintenance of cameras, SS nut & bolts for fixing camera and other accessories required for complete installation and commissioning of the pole, submission of structural stability certificate based on existing soil bearing capacity and wind speed from Govt. Engineering colleges etc complete as per specifications and Tender Document of below mentioned height of the pole. (Foundation drawing and other details to be submitted prior to installation as per tender document) Note: In case pole do not have ladder arrangement for maintenance purpose, then vendor to arrange for ladder for installation & maintenance purpose throughout the contract period including CAMC period at no additional cost to IOCL.
Installation, configuration, integration, testing and commissioning of Network Attached Storage ( NAS
Installation, configuration, integration, testing and commissioning of CCTV client work station along with client software & licenses, key board, mouse, hardware & connector for repeat/ Dual display on wall mounted LED screen, OS, Antivirus, etc complete as per specifications and Tender Document. ( Location : Control Room - 2 nos.(1No for Pipeline,1 No for Marketing), Security room- 1 no. ,Mkt. TM room - 1 no.,Pipeline TM Room - 1 no.)
Cabling, JB, Earthing, Surge protection
Installation, testing and commissioning of external surge & Lightening protect devices of suitable connector and type along with accessories complete as per specification and tender document at following places.
Earth Pit
Installation, testing and commissioning of Maintenance Free CPRI approved Earth pit with 80 mm dia of minimum 3mtr length safe earthing electrode with Pipe-in-pipe technology consisting of two mild steel pipes one inside the other, hot dip galvanized (80-100 microns), filled with high conductive & corrosion resistance crystalline mixture and backfilling compound around electrode, brick masonry earth pit including plastering in CM 1:4, 600x600 mm C.I. Manhole chamber including providing
Laying, glanding, ferruling, termination of FRLS Armoured Copper Power cable as per tender specifications.
Laying, glanding, ferruling, termination of 6 core single mode armoured optical fibre cable as per tender specifications and instructions of Engineer in charge.
Laying, glanding, ferruling, termination of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.
Laying, ferruling, termination of Pre fab CAT 6 Ethernet un-armoured cable as per tender specifications and instructions of Engineer in charge.
Laying, glanding, ferruling, termination of 1C x 6 Sq. mm Flexible copper insulated green wire for earthing instruments, cable tray at regular interval and junction boxes etc complete as per specification and tender document
Laying of anodized Aluminium perforated cable trays , tray covers along with structural steel for mounting of the cable tray. Complete as per specifications / tender documents.
Installation of Exd/FLP -Junction Box/Power distribution box with IP 65 as per specification suitable for hazardous area of zone 1, group IIA/IIB, T3 or better having CCOE/CMRI approval. It shall be complete in all respect. Accessories like certified double compression cable glands with PVC shrouds & plugs for excess entries, SS 316 engraved tag plate, mounting clamp & SS 316 fasteners. Complete as per specification / tender documents.
Fabrication , cutting , laying & connection of hot dip GI earth strip ( 50 X 6) within earth station. Hot dip galvanizing (800 gm/m2 as per IS 4759) shall be done after all fabrication.
Laying of 50 mm HDPE pipe of minimum 2.5 mm thick along with accessories as per tender specifications and instructions of Engineer in charge.
Design, fabrication, painting & erection of Structural steel (MS) for erection of cable bridge (if required) for laying of above ground cables at road crossing or any other place within the Terminal including painting, Civil foundations, nuts, bolts, washers, cleats, stiffeners, gussets, base plate etc
Installation, testing and commissioning of MCT block for entire CCTV system to Control Room, Admin Building, & Security Room with minimum 50% spare MCT blocks for future cable entry along with frame and mounting accessories complete as per specification and tender document.
Other Services
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600
Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
Centering and shuttering including strutting, propping etc. and removal of form work for:
Providing and laying in position specified grade of reinforced cement concrete excluding the cost
Supply of Steel reinforcement for R.C.C. including straightening, cutting bending, placing in position and
Thermo Mechanically Treated Bars Fe 500D
Demolishing cement concrete manually/ by mechanical means including disposal of material outside premises at an unobjectionable place as per direction
Re-laying corporation supplied cable
1.5 sq.mm to 2.5 sq.mm XLPE
4 sq.mm to 10 sq.mm XLPE / AYFY
Description
Supply of managed 8 port L2 switch
Installation of managed 8 port L2 switch
Description
CAMC for 1st year @1.5%
Description
Supply of hot dip GI earth strip ( 50 X 6) within earth station. Hot dip galvanizing (800 gm/m2 as per IS 4759) shall be done after all fabrication.
Supply of 50 mm HDPE pipe of minimum 2.5 mm thick along with accessoriesas per tender specifications and instructions of Engineer in charge.
Description
Installation, configuration, integration, testing and commissioning of Integral Explosion Proof HD IP PTZ cameras (2MP) including power supply unit / POE, surge protection unit and mounting accessories as per the tender specifications and instructions of Engineer in charge.
Installation, configuration, integration, testing and commissioning of 4 port Industrial grade layer 2 Managed POE based Ethernet Switch for connecting Cameras with 4 Nos. RJ copper port and 2 Nos. optical fibre ports with inbuilt/external surge protector (Type 1+2) at the input power supply as per specifications and Tender Document.
Installation, erection & foundation of Heavy Duty self supported Hot Dip Galvanized Poles for mounting of CCTV cameras along with civil foundation along with GI foundation bolt, mounting brackets, ladder arrangement (taking into account of safety during climbing) on the pole for installation and maintenance of cameras, SS nut & bolts for fixing camera and other accessories required for complete installation and commissioning of the pole, submission of structural stability certificate based on existing soil bearing capacity and wind speed from Govt. Engineering colleges etc complete as per specifications and Tender Document of below mentioned height of the pole. (Foundation drawing and other details to be submitted prior to installation as per tender document) Note: In case pole do not have ladder arrangement for maintenance purpose, then vendor to arrange for ladder for installation & maintenance purpose throughout the contract period including CAMC period at no additional cost to IOCL.
Installation, configuration, integration, testing and commissioning of Network Attached Storage ( NAS
Installation, configuration, integration, testing and commissioning of CCTV client work station along with client software & licenses, key board, mouse, hardware & connector for repeat/ Dual display on wall mounted LED screen, OS, Antivirus, etc complete as per specifications and Tender Document. ( Location : Control Room - 2 nos.(1No for Pipeline,1 No for Marketing), Security room- 1 no. ,Mkt. TM room - 1 no.,Pipeline TM Room - 1 no.)
Cabling, JB, Earthing, Surge protection
Installation, testing and commissioning of external surge & Lightening protect devices of suitable connector and type along with accessories complete as per specification and tender document at following places.
Earth Pit
Installation, testing and commissioning of Maintenance Free CPRI approved Earth pit with 80 mm dia of minimum 3mtr length safe earthing electrode with Pipe-in-pipe technology consisting of two mild steel pipes one inside the other, hot dip galvanized (80-100 microns), filled with high conductive & corrosion resistance crystalline mixture and backfilling compound around electrode, brick masonry earth pit including plastering in CM 1:4, 600x600 mm C.I. Manhole chamber including providing
Laying, glanding, ferruling, termination of FRLS Armoured Copper Power cable as per tender specifications.
Laying, glanding, ferruling, termination of 6 core single mode armoured optical fibre cable as per tender specifications and instructions of Engineer in charge.
Laying, glanding, ferruling, termination of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge.
Laying, ferruling, termination of Pre fab CAT 6 Ethernet un-armoured cable as per tender specifications and instructions of Engineer in charge.
Laying, glanding, ferruling, termination of 1C x 6 Sq. mm Flexible copper insulated green wire for earthing instruments, cable tray at regular interval and junction boxes etc complete as per specification and tender document
Laying of anodized Aluminium perforated cable trays , tray covers along with structural steel for mounting of the cable tray. Complete as per specifications / tender documents.
Installation of Exd/FLP -Junction Box/Power distribution box with IP 65 as per specification suitable for hazardous area of zone 1, group IIA/IIB, T3 or better having CCOE/CMRI approval. It shall be complete in all respect. Accessories like certified double compression cable glands with PVC shrouds & plugs for excess entries, SS 316 engraved tag plate, mounting clamp & SS 316 fasteners. Complete as per specification / tender documents.
12 ways JB
8 ways JB
6 ways JB
Fabrication , cutting , laying & connection of hot dip GI earth strip ( 50 X 6) within earth station. Hot dip galvanizing (800 gm/m2 as per IS 4759) shall be done after all fabrication.
Laying of 50 mm HDPE pipe of minimum 2.5 mm thick along with accessories as per tender specifications and instructions of Engineer in charge.
Design, fabrication, painting & erection of Structural steel (MS) for erection of cable bridge (if required) for laying of above ground cables at road crossing or any other place within the Terminal including painting, Civil foundations, nuts, bolts, washers, cleats, stiffeners, gussets, base plate etc
Installation, testing and commissioning of MCT block for entire CCTV system to Control Room, Admin Building, & Security Room with minimum 50% spare MCT blocks for future cable entry along with frame and mounting accessories complete as per specification and tender document.
Other Services
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600
Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
Centering and shuttering including strutting, propping etc. and removal of form work for:
Providing and laying in position specified grade of reinforced cement concrete excluding the cost
Supply of Steel reinforcement for R.C.C. including straightening, cutting bending, placing in position and
Thermo Mechanically Treated Bars Fe 500D
Demolishing cement concrete manually/ by mechanical means including disposal of material outside premises at an unobjectionable place as per direction
Re-laying corporation supplied cable
1.5 sq.mm to 2.5 sq.mm XLPE
4 sq.mm to 10 sq.mm XLPE / AYFY
Description
Installation of managed 8 port L2 switch
Description
CAMC for 1st year @1.5%
Formula applied
LIST (A+B+C+D)
LIST (E+F+G+H)
LIST (A+B+C+D+ E+F+G+H)
Qouted Price(With GST)
Qouted Price(With GST)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.78 MB
UPSONIT.pdf
Tender Documents • 0.76 MB
PriceBid.xls
Other Document • 0.30 MB
Download all tender documents and submit your bid