HQ CWE AF Chakeri Kanpur
RENOVATION OF FLOOR AREA AND INSTALLATION OF FALSE CEILING FOR MODERN MACHINERY ROOM EXTN OF ROOM AREA TO ANNEXE IN GED AT 4 BRD AT AFS KANPUR
2022_MES_519294_2
CA No.CWE(AF)/CHK/BR/T-04 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
Chakeri Kanpur
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) BR Chakeri
₹50,000
Yes
13 Jun 2022
19 May 2022
4 Jun 2022
19 May 2022
2 Jun 2022
21 May 2022
Amount
Demolition of cement concrete (unreinforced) not exc 15 cm thickness (below or above ground level ) including removal of rubbish out side MOD & cleaning the surface with contractor's own arrangment complete all as specified & directed.
Excavation in trenches not exc 1.5m wide and not exc 1.5 m in depth for foundation etc and getting out in soft/loose soil complete all as specified and as directed.
M&L for PCC 1:4:8 (using 40mm graded crushed stone aggregate) type D- 2 as in foundation filling and mass concrete complete all as specified and directed.
M & L for mild steel TMT bars 10mm dia & over cut to length bent to shape required including,cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed.
All as per item No 4 above but 6 to 8 mm dia of bar.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation, plinth beams and similar work vertical or to batter for rough finished surfaces of concrete.
M&L RCC M-25 (design mix ) (using 20mm graded crushed stone aggregate) as in foundation, raft, footings, base of coloumn, beams, plinth beams , slab etc complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as specified and as directed.
Removing excavated material not exc 50m and depositing where directed at a level not exc. 1.5m above starting point complete all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness laid bedded and pointed in any mortar complete all as specified and directed.
M&L 100 mm thick PCC 1:4:8 as in sub base (using 40mm graded crushed stone aggregate) type D- 2 complete all as specified and directed.
Demolition of brick work / stone masonry built in cement mortar complete all as specified and directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius in half brick thick wall built in CM 1:4 complete all as specified and directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and directed.
M&L for rendering 15 mm thick on brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed
M&L PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping, bed block for fixing of structural angle iron post or any other similar work including form work complete all as specified and directed.
S&F mild steel anchorage bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, 30 cm long complete all as specified and directed.
S&F rolled mild steel joist, channel, angle or tee sections, fixed independently, as in posts of truss without connecting plates etc (cut to ordinary lengths i.e within 20mm of the length indicated) conforming to grade E-250 (Fe-410W quality) of any size shape complete all as specified and directed.
S&F compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc complete all as specified and directed.
S&F rolled mild steel section as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
S&F coloured galvalume profile sheet in roofing shall be with feed material manufactured from 0.50 mm (minimum) base metal thickness (BMT), minimum 550 MPa yield strength and shall confirm to physical specifications of ASTM-792 or equivalent. colour coated galvalume sheet shall have maximum pitch of 250 mm C/C and minimum 28 mm crest depth in length as per site requirement. The steel sheet shall be coated with hot dip metallic Aluminium Zinc alloy (55% Aluminiumm, 43.5% Zinc, 1.5% silicon) coating AZ 150 as 150 gm/Sq. mt total on both sides. The contractor shall submit manufacturer test certificates for the chemical and mechanical properties, confirming genuinity of materials including base metal thickness paint thickness and AZ 150 coating thickness must be submitted for approval to GE prior to the installation / fixing. The manufacturer of sheet should submit related documents for expected product service performance of pre painted metal sheet as per relevant ASTM/ IS. Manufacturer‟s recommended installation methodology shall be adopted for installation of roofing including profiled sheet, capping, trims, flashings, gutter and all types of accessories considered for roofing. Fastener shall be used for fixing roofing system as per manufacturer‟s recommendation. The painting shall be coloured baked enamel super durable polyester with silicon coating of film thickness of minimum 25 micron (including primer) on top and minimum 10 micron (including primer) on interior face. The paint shall be of shade as approved by GE. The sheet shall have wide pans with minimum 2 small upward stiffening ribs for effective water shedding and special male/ female ends with full return legs on laps for purlin support and fixed with self-driling screws all as specified and directed.
(Note : Total thickness of sheet with BMT , AZ 150 coating and panting shall be minimum 0.575 mm thick. If 0.575 mm thickness sheet is not available in market then next higher thickness of sheet shall be applicable without any price adjustment.)
M & L for 16 mm thick of size 600mmx 600 mm mineral fibre false ceiling system of pattern classic lite RH 99 (bevelled tegular edge) of make Armstrong or equivalent make and model as approved by GE including grid system using hot dipped galvanised steel section, exposed surface with pre-powder coated capping, main runner and cross runner and to comprise main tee/runner 15 mm x 38 mm size (load carrying capacity 14 Kg/Sqm) spaced at 1200 mm long cross tee/runner to be interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm module, cut sub cross tee/runner 600 mm require independent support. Wall angle of size 19 mm x 19 mm, secured to the periphery of the wall at 450 mm maximum centre The above grid is suspended at every 1200 mm centre to centre in both direction and starting from wall at the distance 350 mm from wall by using 3.50 mm dia line wire with suitable fasteners and hook clip complete all as specified & directed.
S&F anodised aluminium frame for aluminium partition of different standard sections with one or more rebates including jointing cleat for fixing etc of approved make JINDAL or equivalent complete all as specified and as directed.
S&F 4.8 mm thick plain sheet glass, ordinary quality and glazing with rubber beading and aluminium beads to aluminium frame work in squares exceeding 0.5 Sqm in each pane complete all as specified and as directed.
M & L for aluminium anodised door with shutter, chowkat/ frame made with aluminium section of size 100 x 44 x 2mm thick, vertical styles of shutters made with sections 84 x 44 x 2mm thick, and top/ middle/ bottom rail of shutter with section 114 x 44 x 2mm thick, and including 5 mm thick tinted glass panes, inserts including necessary fixing arrangement, jointing cleats, glazing clips, rubber packing, aluminium anodised beading screws, etc., tower bolt 200mm size, mortice lock 100mm size 4 leaver, double action floor door spring, american style handles, 300mm long sliding door bolt etc., fittied to shuuters and frames fixed in opening with aluminium hold fast of 25 x 3mm flat 150mm long 6 Nos in each frame including cutting holes in brick work and embedded in PCC 1:2:4 bed block of size 150 x 150 x 150mm each and match the existing surfaces complete all as specifed and directed.
M & L aluminium anodised frame with sliding window including hold fast/ screw dirlled, punching, anchorage rod aluminium cleats, making good the disturbed area with existing finishing existing finishing so as to match with under mentioned specification complete all as specifed and directed. (a) Frame of window 63.5 x 38 x 2mm (b) Shutter top and bottom 39.40 x 17.76 x 1.5mm (c) shutter inter lock section 38.40 x 17.70 x 1.5mm (d) Top size guide 61.60 x 31.75 x 1.50mm (e) Bottom guide 61.60 x 31.75 x 1.50mm (f) 5mm thick tinted glass with aluminium glazing clips rubber beads area not exceeding 1.50mm size (g) Handle section 39.40 x 17.70 x 1.50mm (h) Angle leaf 25 x 25 x 3mm
M & L for aluminium anodised sliding door made with aluminium section No 19568 for vertical frame styles and top rail, aluminium section No 19564 for for aluminium vertical runner and middle rail, aluminium section No 19509 for aluminium meeting style , aluminium section No 20002 for lock rail , aluminium section No 19584 for bottom and including 5 mm thick tinted glass panes, inserts including necessary fixing arrangement, jointing cleats, glazing clips, rubber packing, aluminium anodised beading screws, and guide rail with sliding arrangement complete all as specified and shown on drawing No CE (AF)/NGP/TD-115/2013 sheet No 1/3 to 3/3
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces and applying two coats of synthetic enamel paint exceeding 10 cm width or girth over a coat of red oxide primer complete all as specified and directed.
M & L for concealed/surface point wiring one light, fan, call bell point controlled by one switch on wall and surface wiring on ceiling/roof/trusses with necessary fixing arrangements with stranded PVC-FRLSH insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including 16 gauge stove enameled rigid steel conduit (metallic) not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.0 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators with brass screw and cup washers including PVC-FRLSH insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of paris/ Putty or distemper / colour wash with same existing colour surfaces complete all as specified and directed.
All as per item No. 31 above but 5 Amp independent socket point controlled by one switch.
All as per item No. 31 above but for one 3 Pin socket point controlled by one switch on same board
All as per item No. 31 above but for power point wiring with 2.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
S&F switch flush type single pole one way 5 Amps, 240 volts, white finish ISI marked complete all as specified & directed.
S&F switch flush type 15 Amps, 240 Volts single pole white finish complete ISI marked complete all as specified & directed.
S&F socket outlet 5 pin, 5 Amps flush type white finish complete conforming/ ISI marked complete all as specified & directed.
S&F socket outlet 2 in 1, 3 pin, 5/15 A, flush type universal, 240 V white finish complete conforming/ ISI marked complete all as specified & directed.
S&F ceiling rose, surface backlite, 65 x 20 mm three terminalconforming/ ISI marked complete all as specified & directed.
S&F double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified & directed.
S&F double door metallic sheet metal enclosure for DB when MCBs to be used SPN 4 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified & directed.
S&F MCB SP 240 volt 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified & directed.
S&F MCB SPN 240 volt 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified & directed.
S&F MCB SPN 240 volt 40 Amp to 63 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified & directed.
S&F sheet metal enclosure , 20A single pole and neutral with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB 32 Amp fixed properly on in concealed position complete all as specified & directed.
S&F sub main wiring with two single core PVC-FRLSH insulated unsheathed multi stranded copper conductor cable of size 4 sqmm drawn in MS conduit with one run of 4 Sqmm PVC-FRLSH insulated unsheathed multi stranded copper conductor as a continuous earth wire complete excluding rigid stove enameled steel conduit ISI marked of size not less than 25 mm dia in concealed/surface wiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly complete all as specified & directed. Note : M S Conduit and cutting cheaseling and making good will be measured and paid separately
S&F rigid metallic medium 25mm dia stove enameled steel conduit ISI marked in concealed position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddlers, pipe hooks etc fixed properly on as in concealed position complete all as specified & directed.
S&F air circulator fan 230 volts single phase oscilating 450 mm sweep suitable for wall mounting with clamps nut bolts and washer etc. complete all as specified and directed.
S&F high efficiency, recessed mounted 2'x2' energy saver LED light fitting 36 watt, 230 Volts complete accessories, prewired including required fixing arrangements and electrical connection three core copper cable from ceiling rose to led light fitting complete all as specified & directed. Make : PHILIPS RC380B LED36S-6500G4L60 W60PSUOD or equivalent in Wipro/Havells.
S&F MCCB 415 Volts 32 Amps capacity , 25 KA, Ics=100% Icu, four pole with Sheet steel enclosure for suitable size of MCCB with locking arrangement consisting of necessary suitable arrangements for incoming & out going cables with cable glands and fixing arrangement on pole/wall ,PCC work including necessary flat iron clamps with nuts, bolts & washers and powder coated complete all as specified & directed.
M&L of MS angle or channel iron including flat iron clamp with bolt, nut & washers drilling for bolts in any shape or size as indicated or directed and including painting with one coat of red oxide primer and two coats of aluminium paint before fixings and one coat of aluminium paint after fixing complete all as specified & directed.
Supply & fixing or laying galvanised steel tubing light grade (ISI marked) for protection of under ground cable on poles/ walls under road crossing etc of size 40mm bore complete all as specified & directed.
Supply & fixing or laying galvanised steel tubing light grade (ISI marked) for protection of under ground cable on poles/ walls under road crossing etc of size 25mm bore complete all as specified & directed.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed .
Supply, laid in trench/ fixed with surface of wall / roof etc all in given location, jointing, thembling and glanding in suitable size , testing to LT cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armored electric power cable (heavy duty) with aluminum conductor 1100 Volts , grade cross section area 95 Sqmm x 3.5 core (earthed) complete all as specified and directed.
All as per srl item No 55 above but 16 Sqmm, 4 core.
Supply, install, testing and commissioning and testing factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) indoor type, IP-54 protection, platform mounted, suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated aluminium bus bars 300 amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, made of 2.0mm CRCA MS sheet with support of angle iron of size 50 x 50 x 5mm to cover all corner and standing legs of angle iron work, duly powder coated finish. Front & rear opening type with aprons for cable entry with double door shutter and locking arrangement. The scope of work includes provision of the following :- INCOMING (a) MCCB 250 amps, 4 pole, 25 KA (Ics = 100% Icu), with adjustable thermal & adjustable magnetic setting, 50 Hz, 415 volts grade - 01 No. (b) Bus bar (Aluminium strip) 300Amp, 4 pole, not less than 30cm long mounted on insulators for incoming supply - 01 No. (c) Digital volt meter, Amp meter with rotary switch complete. - 01 set. (d) LED type Neon indicating lamps (R, Y & B) -01 Set. OUT GOING (a) MCCB 40 amps, 4 pole, 25 KA (Ics =100% Icu), with adjustable thermal & adjustable magnetic setting, 50 Hz, 415 volts grade - 07 No.
M&L earthing complete with galvanised steet earth electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth electrode not less than 1.5 mtr below normal ground level, connected to galvanised iron wire 4mm as earth wire by means of bolt, check nuts & washer of GI or steel connected to earth test point including earth strip from earth electrode to test point, Gl pipe 20 mm dia light grade as protection pipe and 20mm dia GI pipe light grade for watering pipe of required length including charcoal dust, common, salt, excavation and earth work, earth pit with PCC 1:3:6 type C 1 using 20mm graded stone aggregate, precast RCC cover 40mm thickness reinforced with 03 Nos TMT bars, 8 mm dia, both ways, funnel with wire mesh, testing and rest as shown in electrical plate No 3 of SSR Part -I complete all as specified and directed. (Note: (i) Excavation earth work and all connected items shall be deemed included in quoted unit rate. (ii) GI earth wire and GI protection pipe 20mm dia beyond 7.5m long shall be measured and paid separately.
M&L earthing with galvanised cast iron earth plate of size 600 x 600 x 6 mm thick burred directly in ground not less than 2.25 Mtr below normal ground level, earth plate packed on all side with charcoal mixed wih salt to a thickness of 150 MM connected by GI earth strip of size 32 x 6mm thick soldered and rivetted to earth plate. GI earth strip will be protected by using 50 mm bore light grade GI pipe earth plate to steel tubular pole including flat iron clamp 25 x 3 mm including bolts nut and washers complete including watering GI pipe 20 mm dia light grade 2.5 Mtr long the earthing include PCC pit including necessary earth work and disposal of surplus soil to a distance not less than 50 Mtrs, chamber of PCC (1:4:8) type D 2 using 40 MM graded stone aggregate, coping shall be PCC(1:3:6) type C1 using 20 MM graded stone aggregate, RCC pit cover 50 MM thick (1:2:4) type B1 using 20 MM graded stone aggregate, reinforced with 8 MM MS bar at 80 MM C/C both way in lieu of CI pit cover and angle iron frame including flame funnel, wire mess, GI earth wire, 8 SWG under the earth and on the pole upto height of 1.5 Mtr shall be protected by 15 MM dia GI pipe (Light grade) GI pipe to be fixed with pole by means of 2 Nos flat iron clamp 25 x 3 MM size complete with bolts with nuts washers etc complete all as specified and shown in Electrical plate No 3 of MES SSR part -I 2009. (NOTE: 1. GI earth strip upto & including 7.5RM from the earth test point shall be deemed included in quoted unit rate. 2. GI earth strip beyond 7.5RM shall be measured and paid separately under respective items).
S&F GI strip 32 x 6 mm with proper clamp, saddles, nut bolts , washers etc properly and connected to equipment or panel complete all as specified & directed.
S&F 4mm dia galvanised iron or steel wire as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified & directed.
B R CONSTRUCTIONS
DHARM ENTERPRISES
FATEHPUR CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .