Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹44.1 L+₹83,783 (1.94%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹44.6 L+₹1.4 L (3.19%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹46.7 L+₹3.5 L (8.03%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹50.4 L+₹7.1 L (16.4%)Rejected-Finance PLOT NO 14 SHIV COLONY KATI GHATI RAJGARH ROAD ALWER RAJ | ALWAR | ALWAR | RAJASTHAN | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹60 L
EMD Value
₹1.1 L
Closing Date
3 Nov 2023, 6:00 pmClosed
CWE (A) Jaisalmer
HQ CWE (A) Jaisalmer-345001
REPAIR AND MAINTENANCE OF POWER / DISTRIBUTION TRANSFORMER, VCBs, VOLTAGE STABILIZER AND ALLIED WORKS IN CERTAIN AREA OF MIL STN JAISALMER UNDER GE (A) JAISALMER
2023_MES_620838_1
84113
Open Tender
Electrical and Maintenance Works
Works
180 days
GE (A) Jaisalmer
As per NIT
8 documents required · 8 mandatory
₹1,000
AO GE (A) Jaisalmer
₹1.1 L
Yes
27 Jan 2024
27 Sept 2023
6 Nov 2023
27 Sept 2023
3 Nov 2023
20 Oct 2023
27 Sept 2023 - 3 Oct 2023
Amount
Taking down and dismounting defective transformer 11/0.433 KV of capacity 25 KVA to 75 KVA from foundation/ pole by using crane and transporting to workshop or factory (authrorised for such repair) fo repair after disconnecting HV side HT cable or HT aluminium conductor and LV side LT cable , dismantling the same for repair & renewal of unserviceable parts and reassembling complete ,spray painting with two coats of synthetic enamelled grey paint after preparation of old surface writing MES No with white paint of suitable size letter and transporting to back from workshop to site, installation on plate form/pole, testing & commissioning to entire satisfaction of Engineer-in-Charge.
Taking down and dismounting defective transformer 11/0.433 KV of capacity 100 KVA to 250 KVA from foundation/ pole by using crane and transporting to workshop or factory (authrorised for such repair) for repair after disconnecting HV side HT cable or HT aluminium conductor and LV side LT cable , dismantling the same for repair & renewal of unserviceable parts and reassembling complete, spray painting with two coats of synthetic enamelled grey paint after preparation of old surface writing MES No with white paint of suitable size letter and transporting to back from workshop to site, installation on plate form/pole, testing & commissioning to entire satisfaction of Engineer-in-Charge.
Taking down and dismounting defective transformer 11/0.433 KV of capacity 315 KVA to 630 KVA from foundation/ pole by using crane and transporting to workshop or factory (authrorised for such repair) for repair after disconnecting HV side HT cable or HT aluminium conductor, LV side, LT cable dismantling the same for repair & renewal of unserviceable parts and reassembling complete, spray painting with two coats of synthetic enamelled grey paint after preparation of old surface writing MES NO with white paint of suitable size letter and transporting to back from workshop to site, installation on plate form/pole, testing & commissioning to entire satisfaction of Engineer-In-Charge. Note for ser item No 1 to 3 :- Spare parts i.e transformer oil, copper winding wire for rewinding shall be measured and paid separately.
S&F in repair of synthetic rubberised gaskets 4mm thick for top cover and other joints for transformer capacity 25 KVA to 75 KVA ,11/0.433 KV
S&F in repair of synthetic rubberised gaskets 4mm thick for top cover and other joints for transformer capacity 160 KVA to 630 KVA ,11/0.433 KV
M&L for taking out unserviceable core and limb and HV/LV winding of transformer and taking out burnt copper winding wire cleaning carefully an rewinding the same with new superior quality 99.99% pure copper enamelled wire as per existing gauge including insulating material for transformer 25 KVA to 630 KVA complete all as specified & directed by Engineer-in - Charge.
Dehydration of transformer oil (mounted on poles/platform etc) with the help of filtering and drying plant by mechanical machines of suitable capacity to achieve dielectric strength of 50 KV complete all as specified and directed by Engineer-in-Charge. (Note : For any capacity of Transformer)
Supply only transformer oil for topping up of transformers any capacity all as conforming to IS - 335 at different transformers & different locations. Note:- (i) The dielectric strength of the transformer oil must be 45 KV r.m.s (min). (ii) Test certificate in respect of the same to be submitted by the contractor duly signed by the Engr-In-Charge.
M&L in repair of unserviceable HT brass stem with nuts, washers of transformer 63 KVA to 630 KVA complete all as specified & directed by Engineer-in - Charge.
M&L in repair of unserviceable LT brass Stem with nuts, washers of transformer 11/0.433 KV of capacity 25 KVA to 63 KVA complete all as specified & directed by Engineer-in - Charge.
M&L in repair of unserviceable LT brass Stem with nuts, washers of transformer 11/0.433 KV of capacity 100KVA to 250 KVA complete all as specified & directed by Engineer-in - Charge.
M&L in repair of unserviceable LT brass Stem with nuts, washers of transformer 11/0.433 KV of capacity 315KVA to 630 KVA complete all as specified & directed by Engineer-in - Charge.
M&Lin repair of unserviceable breather assembly with new silica gel of transformer 11/0.433 KV of capacity 25 KVA to 100 KVA complete all as specified & directed by Engineer-in - Charge.
M&L in repair of unserviceable breather assembly with silica gel of transformer 11/0.433 KV of capacity 160 KVA to 630 KVA complete all as specified & directed by Engineer-in - Charge.
S&F in repair of winding tempreture indication gauge anlog type complete suitable for transformer 11/.433 KV, 100 KVA up to 630 KVA complete all as specified & directed by Engineer-in - Charge.
S&F in repair of porcelain transformer bushing 11 KV suitable for transformer 63 KVA to 100 KVA complete all as specified & directed by Engineer-in - Charge.
S&F in repair of porcelain transformer bushing 11 KV suitable for transformer 160 to 630 KVA complete all as specified & directed by Engineer-in - Charge.
S&F in repair of porcelain transformer bushing 433 volts suitable for transformer up to 100 KVA complete all as specified & directed by Engineer-in - Charge.
S&F in repair of porcelain transformer bushing 433 volts suitable for transformer 160 KVA upto 630KVA complete all as specified & directed by Engineer-in - Charge.
S&F in repair tap changer suitable for 11/440 KV transformer of capacity 63 to 630 KVA complete all as specified & directed by Engineer-in - Charge.
S&F in repair dimmer suitable for voltage stablizer 75 KVA (3x25) complete all as specified and directed by Engineer-in-Charge.
S&F in repair dimmer suitable for voltage stablizer 50 KVA complete all as specified and directed by Engineer-in-Charge.
S&F in repair servo motor 3 Kg / Sqcm suitable for voltage stablizer 50/75 KVA (3x25) complete all as specified and directed by Engineer-in-Charge.
S&F in repair PCB, including carben bush, limit swith, push button etc suitable for voltage stablizer 50/75 KVA (3x25) complte all as spcified and directed by Engineer-in-Charge.
Supply, Jointing and testing indoor type cable termination heat shrinkable joint kit 11 KV unearthed grade suitable for size 50 Sqmm to 95 Sqmm 3 core 11 KV under ground XLPE cable complete all as directed by Engineer-in-Charge.
Supply, Jointing and testing indoor type cable termination heat shrinkable joint kit 11 KV unearthed grade suitable for size 120 Sqmm to 185 Sqmm 3 core 11 KV under ground XLPE cable complete all as directed by Engineer-in-Charge.
Supply, Jointing and testing outdoor type cable termination heat shrinkable joint kit 11 KV Unearthed grade suitable for size 50 Sqmm to 95 Sqmm 3 core 11 KV under ground XLPE cable complete all as directed by Engineer-in-Charge.
Supply, Jointing and testing outdoor type cable termination heat shrinkable joint kit 11 KV Unearthed grade suitable for size 120 Sqmm to 185 Sqmm 3 core 11 KV under ground XLPE cable complete all as directed by Engineer-in-Charge.
Supply jointing and testing straight through heat shrinkable joint kit 11 KV unearthed grade suitable for size 50 Sqmm to 95 Sqmm 3 core 11 KV under ground XLPE cable complete all as directed by Engineer-in-Charge.
Supply jointing and testing straight through heat shrinkable joint kit 11 KV unearthed grade suitable for size 120 Sqmm to 185 Sqmm 3 core 11 KV under ground XLPE cable complete all as directed by Engineer-in-Charge.
Opening the binding wire from pin / disc insulator on PCC pole 11 meter long for re-stretching the ACSR conductor upto permissible limits, after re-stretching without kinks & bends, binding the pin / disc insulator with appropriate size of aluminium binding wire complete all as specified & directed by Engineer-in- Charge. NOTE: (i) The above work includes dismenteling & opening Jumpers & cross arms nut and bolts and reassembling after restreching, clearing/ prooning of tree branches falling around the conductors. (ii) Cost of binding wire deemed to be included in the quoted rate. No extra amount shall be paid to this acccount.
Opening the binding wire from "J" hook or opening nut, bolts of cross arms on PCC pole 11 meter long for re-stretching the galvanised iron earth wire any size, after re-stretching without kinks & bend , binding the "J" hook with appropriate size of aluminium binding wire or fixing with appropriate size of nut, bolts, washers complete all as specified & directed by Engineer-in- Charge. NOTE: (i) Cost of binding wire / nut bolts and washers deemed to be included in the quoted rate. No extra amount shall be paid to this acccount.
M&L for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (12 Insulators Vertical type operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 200 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified. (Note:- Stack for fixing with poles shall be measure and paid separately).
Material and labour for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (09 Insulators Vertical type operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 200 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified. (Note:- Stack for fixing with poles shall be measure and paid separately).
Material and labour for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (09 Insulators Horizental type operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 200 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified. (Note:- Stack for fixing with poles shall be measure and paid separately).
S&F in repair, pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified & directed by Engineer-in-charge.
S&F in repair, disc type insulator, porcelain, vitreous with hardware, 145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly for 11000 volts grade complete all as specified & directed by Engineer-in-charge.
S&F in repair insulator, disc type,porcelain series in three with hardware, vitreous,white, brown or green of suitable size socket type, single disc assembly for tension clamp for conductor working pressure 33000 Volt complete all as specified and directed.
S&F in repair insulator, pin type,porcelain, vitreous,white, brown or green of suitable size with clamp for conductor working pressure 33000 Volt complete all as specified and directed.
Supply, laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, of size 120 sqmm, 3 core incl taking down unsv one complete.Make-Havells/Polycab/ CCI
Supply, lay, test and commissioning of LT, under ground XLPE insulated, heavy duty, 1100V grade of size 185 Sqmm 3.5 core electric cable with aluminum conductor, served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipe, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by Engineer-in-Charge of following sizes:- Note : Earthwork excavation sand cushioning, Jodhpur Stone patti, GI protection pipe shall be measured and paid separately in their respective items.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc not exceeding 10 sqm on plan and getting out in Soft/disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.00m depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming excavated Soft/Disintegrated rock in layers all as specified & directed at site.
Removing excavated Soft/Disintegrated rock to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed by Engineer-in-Charge.
M&L for sand cushioning to underground PVC/XLPE cable with tibba sand and punning to provide required cover complete all as directed by Engineer-in-charge. (Note :- For the purpose of payment only punned thickness shall be measured).
Supplying and laying Jodhpur stone quarry faced stone slab cover 25 to 30 cm in width, 50 to 60 cm long and 40 to 50 mm thick, laid dry and abutting each other with gap between adjacent slab not exceeding 10 mm over under ground cables for protection complete all as specified & directed by Engineer-in-Charge.
M&L for cutting the existing bituminous road / hard standing to size not exceeding 45cm wide and depth not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surface filled with excavated material and top 200mm depth with plain cement concrete 1:3:6, type C1 using 20mm graded aggregate complete all as specified and directed by Engineer-in-Charge.
S&F in repair GI pipe light grade of dia 80 mm laying in road and along with poles for cable protection complete all as directed by Engr-in-Charge.
Supply ,Transportation, fixng and errection of prestressed cement concerte pole 11 mtr long, miximum cross section 152mmx152mm at top and 152mm x 260 mm at bottom class-9 conforming to IS 01678 and including making alternate white and black strips 30cm height (total No-05 Nos), primer two cots of synthetic enamle paint oer a coat of primer complte all as speficied and directed by Engineer-in-Charge.
M&L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate & salt up to ground level connected to galvanized iron strip 32 x 6mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including all necessary earth work, excavation, earth chamber with PCC 1:3:6, type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified and directed by Engr-in-charge.
Dismantling and Taking down old climbing device and fixing of new anti climbing device, comprising 2.24 mm dia galvanised steel-2 strand barbed wire with 2.00 mm dia barbs wrapped spirally round poles to a length of 0.5 to 1.0 mtr clamped and properly secured or as orded (clamps measured seperatly all as specified).
S&F in repair Expulsion Fuses with fues barel, single pole for HT 11 KV station class type above 25 & upto 50 Amp complete all as specified and directed by Engr-in-Charge.
M&L for cement concrete (1:3:6) type C-2 using 40mm grade stone aggregate for foundation of stay assembly struts or pole etc complete all as directed.
M&L for cement concrete (1:2:4) type B-1 using 20mm grade stone aggregate for coping around poles including necessary form work finishing even and smoth with out using extra cement complete all as directed.
M&L for cement concrete (1:4:8) type D-2 using 40mm grade stone aggregate in foundation of PCC pole/struts as specified including necessary form work finishing even and smoth with out using extra cement complete all as directed.
M&L for painting tranformer complete by removing existing oil paint by scrapping and applying two coats of approved colour synthetic enamel paint (1st grade quality) over a coat of primer after preparation of surfaces including writing SM / MES numbers and date of oil tested etc. all as directed by Engr-In-Charge and applying one coat of cement base paint on transformer plinth complete all as specified and as directed for the following capacity:-
Transformer of capacity 25 KVA to 75 KVA, 11 KV/0.433 KV.
Transformer of capacity 100 KVA to 200 KVA, 11 KV/0.433 KV.
Transformer of capacity 250 to 630 KVA, 11 KV/0.433 KV.
Servicing the 11 KV GOD by cleaning the contact, disc/ pin insulator with CTC and applying the petroleum jelly at the contact point/ down rod links for smooth operation including replacing the rusted/ corroded bolts & nuts and defective insulator of GOD as required complete all as directed by Engineer - in - Charge. Note :- Insulator shall be measured and paid under relevant items of this schedule.
S&F Male/ Moving contact (set of 3 Nos).
S&F Female/ Fixed contact (set of 3 Nos).
Dismantling, taking down and removing the old existing unsv non-functional/broken hinges of any description and in any postiion of existing feeder piller boxes/panel boards/feeder pillar boxes etc and supplying and fixing new cold rolled 100mm long medium weight mild steel but hines in position with necessary spot welding etc including making necessary adjustment for free and smooth movement of panel and locking arrangments complete all as specified and directed by Engineer-in-Charge. (Note : All Hinges fixed in one panel shall be considred under one job only).
Taking down or removing of rusted body part/panel door existing LT Panel feeder pillar box of any size and shap, supply, fixing and febrication in existing, shap and size with and including 2 mm thick CRCA sheet and all jointing material such as nuts, bolts or washer and welding etc. NOTE : (i) The panel board repaired shall be made totally enclosed, weather proof/wemin proof for installing incoming/outgoing MCCB/Switch fuses/cable etc complete all as directed. (ii) The rates quoted by the contractor are deemed to be with and including necessary cutting, welding, levelling and jointing etc. as directed to match & accommodate with the existing feeder pillar box/panel board. (iii) The replaced porting shall be painted with two coat of synthetic enamled paint over a coat of red oxide primer. (iv) The rates quoted by the contrqactor deemed to be with and including dismantling/taking out/removing carefully, any damaed part/portion of the feeder pillar box/panel board as directed.
Preparation of the old decorated existing external and internal steel surfaces fo feeder pillar boxes/panels/boards of any description and in any position including removal of disintegrated & deteriorated paint either by hand scrpping or by blow stopping as required and applying tow coats of synthetic enameled paint (grey in colour) with using spray machine on old prepared surfaces complete all as specified and directed by Engineer-in-Charge.
Dismantling & taking down ACSR conductor, of any size, after taking necessary shut down, for 11 KV HT OH line, by loosening the binding wires, jumpers etc. for replacement of insulator / cross arms etc. complete all as specified and as directed
Dismantling cross arms of MS channels or angle sections etc complete all as directed.
Supply fabricate, fixing structural mild steel RS joist, channel angle iron, flate iron and brackets etc for fabrication of cross arms, bracing supports clamps including D clapms, eye hook and back plate etc fabricated from structural steel section inclduing nuts, bolts,washers, welding (Cold and Hot) drilling holes for bolts, bend to any shape or size as indicated and directed, inclusive of one primer coat and two coats of aluminium paint after preparation of surfaces complete including taking down old materials all as specified and directed by Engineer-in-Charge.
Re-fixing of cross arms/clamps/nuts/bolts/washers etc. (as dismantled under item No. 67.00 hereinbefore) on the refixed/new PCC/RCC poles of any length complete all as specified and as directed
S&F ACSR conductor of size, as required at site, duly binded with insulators, jumpers etc (fixed on poles) complete all as specified and as directed.
Re-stringing and re-connection of ACSR (as dismantled under item Sl No-68) duly binded with insulators, jumpers etc (fixed on poles) complete all as specified and as directed.
S&F in repair of Galvanized stray strand, 7/3.15mm duly cut into required length, fixing with clamps/ loop insulators/stay buckle etc. all as specified and as directed.
S&F in repair Stay assembly, complete with accessories as shown in electrical plate No. 1 complete with stay rod 20mm dia and all other accessories all as specified and as directed. Note :- Loop insulator, stay clamps, stay wire, excavation and concrete to be measured separately under respective items.
S&F Loop type insulator,vitreous porcelain, white/brown/green, Large size with overall dimension 90x90x140 mm having clearence of hole 16mm
M & L repair of GI wire (guard wire) of dia 4 mm minimum complete fixing below the HT /LT over head line counductor including fixing on height of 6 to 9 mtr above ground level in shape and size complete all as specified & directed by Engineer-in-Charge.
Cuttting / trimming of tree branches in close proximity to over head lines to maintain a clearance of 1.5 meters from the over head line to nearby trees complete all as specified. Note :- Only effected area of over head conductor shall be measured as per running meter.
SHOBHIT BUILDERS
SANJOLI CONSTRUCTION COMPANY
star electricals
M/s Yash Electrical and Maintenance
M/s Rohit Construction Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .