Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹66.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER FOR THE WORK | |
| 2 | L2₹76.3 L+₹7.8 L (11.3%)Rejected-AOC 20 SC BOSE COLONY GALL NO 2 DEFENCE LAB ROAD RATNADA JODHPUR 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-AOC OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹76.4 L+₹7.9 L (11.5%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN THE LOWEST BIDDER | |
| 4 | Rejected-Technical TRINNATH LAXMIPUR KHAYERPUR AGARTALA WEST TRIPURA PIN 799008 | WEST TRIPURA | TRIPURA | 799008 | - | Rejected-Technical CONDITIONS NOT COMPLIED WITH | |
| 5 | Rejected-Technical PREET BANQUET PALACE BYE PASS ROAD CHANNI RAMMA JAMMU JAMMU KASHMIR 180012 | JAMMU | JAMMU AND KASHMIR | 180012 | - | Rejected-Technical CONDITIONS NOT COMPLIED WITH |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
18 Nov 2020, 6:00 pmClosed
Commander Works Engineer Bhopal
Headquarters Commander Works Engineer Bhopal Military Engineer Services SI Lines Bhopal-462 001
PROVN OF 100 KW SOLAR POWER PLANT AT DSCC AYODHYA NAGAR BHOPAL UNDER GE DRONACHAL
2020_MES_373354_1
83536/E8
Open Tender
Power/Energy Projects/Products
Item Rate
910 days
Bhopal
As per tender documents
9 documents required · 9 mandatory
₹1,000
GE Dronachal
₹1.5 L
Yes
Commander Works Engineer Bhopal
20 Feb 2021
3 Oct 2020
20 Nov 2020
3 Oct 2020
18 Nov 2020
6 Nov 2020
3 Oct 2020 - 11 Nov 2020
10 Oct 2020
Amount
Taking down cement plaster of any description on brick wall surfaces etc including raking out joints hacking for key , scrubbing down down with water etc complete all as specified. Note:- The demolished material should be disposed off out side the MOD land. The contractor shall quote his rates considering the above fect.
Demolition of brick work or stone boulder masonry built in cement mortar complete all as spd and as directed. Note:- The demolished material should be disposed off out side the MOD land. The contractor shall quote his rates considering the above fect.
Dismantling of RCC other than ground floors and similar suspended works complete all as specified. Note:- Note:- The demolished material should be disposed off out side the MOD land. The contractor shall quote his rates considering the above fect.
Demolition of cement concrete (un- reinforced) above ground floor and paving not exc 15 cm thick complete all as specified. Note:- The demolished material should be disposed off out side the MOD land. The contractor shall quote his rates considering the above fect.
M&L brick work with sub class 'B' bricks of class designation 7.5 all as per IS-1077-1992 (minimum compressive strength of brick 75 kg/Sqcm) old size bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6, complete all as specified.
M&L rendering 15mm thick CM 1:4 on fair face of brick over concrete surface finished even and smooth without using extra cement complete all as spd.
PCC 1:2:4 type B1 (20mm graded aggregate ) as in fillets at junctions between roof and parapet walls, copings rounded or chamfered angles, bed plates, hold fasts, plinth courses, filling in pressed steel frame and the like finished fair and even incl necessary form work complete all as specified.
Supply and fixing 1000 ltr capacity rotational moulded polythene water storage tanks white colour (cylindrical vertical with closed top ) triple layered (ISI Marked) hoisted and fixed in position incl connections etc and including dismantling of existing water tank complete all as specified.
Supply and fixing 2000 ltr capacity rotational moulded polythene water storage tanks white colour (cylindrical vertical with closed top ) triple layered (ISI Marked) hoisted and fixed in position incl connections etc. and including dismantling of existing water tank complete all as specified.
Disconnecting of existing tank for cleaning and removing all scale and dirt from PVC tank by emptying, drying, cleaning by scrubbing the dust with wire brush from tank by removing inlet and outlet pipe and refixing inlet and outlet pipe with new tank connection fitting in the same position after cleaning (capacity of tanks exc. 500 ltrs and n. exc. 1000 ltrs) complete all as specified
Disconnecting of existing tank for cleaning and removing all scale and dirt from PVC tank by emptying, drying, cleaning by scrubbing the dust with wire brush from tank by removing inlet and outlet pipe and refixing inlet and outlet pipe with new tank connection fitting in the same position after cleaning (capacity of tanks exc. 1000 ltrs and n. exc. 2000 ltrs) complete all as specified
Supply and fix Ball brass valves 50mm bore, high pressure, with p0lythene float and fly nut complete screwed for iron pipe or brass ferrule, complete all as specified.
Supply and fixing 25 mm bore tubes "medium grade" galvanized with and incl all fittings complete to walls and ceiling or laid in floors including taking up or down and removal from site complete all as specified.
Supply and fixing 40 mm bore tubes "medium grade" galvanized with and incl all fittings complete to walls and ceiling or laid in floors including taking up or down and removal from site complete all as specified.
Supply and fixing 50 mm bore tubes "medium grade" galvanized with and incl all fittings complete to walls and ceiling or laid in floors including taking up or down and removal from site complete all as specified.
Taking up or down steel tubing and connections including cleaning for refixing or removal to store for 80 mm dia pipe and Refixing old steel tubing and connections in new or old position as in walls, ceiling, floors, etc. complete all as specified.
Screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector etc for 50/80 mm bore pipe complete all as specified.
S & Fixed in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 50 mm bore complete all as specified.
S & Fixed in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 40 mm bore complete all as specified.
S & Fixed in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 25 mm bore complete all as specified.
M&L in repairs 150 mm dia PVC (SWR) rain water pipe fixed to wall/celing including necessary clamp to be provided and taking down of existing rain water pipe with fittings complete all as specified and directed.
S&F 150 mm dia PVC (SWR) bends with rubber ring joints fixed as required complete all as specified.
S&F Grating doom cast iron of size 150 mm complete all as specified.
M&L for preparation of newly plastered or unplastered surfaces with sand papering of walls incl cornices etc. incl washing, rubbing down surfaces and applying two coats of acrylic emulsion exterior weather proof paint over a primer coat (tint as approved by GE) complete all as specified. Note:- Paint and primer shall be 1st quality of Make:- Asian Paint (APEX), ICI Paints (WEATHER SHIELD), Nerolac (EXCEL), Berger Paint (EXPA).
Cutting chases, pinning in brick work and making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified.
Waterproofing of terrace with Dr. Fixit HydroShield PUD Plus OR equivalent product in Asian Paints/ Berger paints Note:- System comes with 10 years waterproofing warranty from Manufacturer or Authorized Applicator.
(A) Surface Preparation (i) All surfaces should be dry and free from contamination such as oil, grease, loose particles, decayed matter, moss, algal growth, laitance and all traces of shutter release oils and curing compounds. (ii) All loose and de-bonded concrete/ screed shall be removed and proper repairing to be carried with polymer modified mortar. Washing the roof-terrace surface and making it dust free. (iii) The careful sealing of existing cracks & joints before the application is extremely important for log lasting waterproofing results. Clean concrete cracks / hairline cracks, of dust, residue or other condemnation. Fill all prepared cracks with acrylic flexible crack filler Dr. Fixit Cracks-X Paste OR equivalent product in Asian Paints/ Berger paints. (iv) Cracks more than 5mm fill all repaired with Polymer modified cement sand mortar in the ratio of 1:3 duly admix with Dr. Fixit Pidicrete URP OR equivalent product in Asian Paints/ Berger paints @ 10% by weight of cement. (v) Pre wet the surface prior to application of primer and allow surface water to evaporate to make surface saturated dry (SSD) condition
(B) Bond Coat (i) Applying Dr Fixit Pidicrete URP OR equivalent product in Asian Paints/ Berger paints a SBR latex based bonding chemical used for repairs & waterproofing, at a ratio 1:1 one part chemical one part cement. Make sure bond coat is done properly and spreader evenly to the entire surface with brush or roller.
(C) Pre-Coat Application (i) Applying one coat of Dr. Fixit Pidicrete URP OR equivalent product in Asian Paints/ Berger paints with cement @ 1:1.5 one part chemical, one and a half part cement and lay 45 GMS fiber mesh on still wet coat of URP. Make sure fiber mesh sticks to the surface evenly.
(D) Primer Application (i) Apply one coat of acrylic based primer Dr. Fixit Primeseal Primer OR equivalent product in Asian Paints/ Berger paints (diluted with water in the ratio of 2:1) spreading at the rate of 8-10 /Sq.mt /Litre. Allow the primer to air cure for 4-6 hours.
(E) Coating Application (i) Stir well before use. Apply 1st coat of Dr. Fixit HydroShield PUD plus OR equivalent product in Asian Paints/ Berger paints without dilution spreading at the rate of 0.70/litre/Sq.mt/Coat until all surface is covered. (ii) Allow the first coat to dry for approximately 4-6 hours before applying the 2nd coat at 90° to the first coat and 3rd coat at 90° to the second coat. Ensure there are no pinholes or air bubbles on the membrane surface. (iii) Apply second coat of Dr. Fixit HydroShield PUD Plus OR equivalent product in Asian Paints/ Berger paints without dilution spreading at the rate of 0.70/litre/Sq.mt/ Coat. Ensure there are no pinholes or air bubbles on the membrane. (iv) Apply third coat of Dr. Fixit HydroShield PUD Plus OR equivalent product in Asian Paints/ Berger paints without dilution spreading at the rate of 0.70/litre/Sq.mt/ Coat to achieve total dry film thickness of 800 to 1000 microns at forced coverage @ 2- 2.1 /litre/Sq.mt in 3 coats. Ensure there are no pinholes or air bubbles on the membrane. (v) Make sure glass fibre mesh is completely embedded. Surface should be smooth after the application. Check to see no void surface is left untreated / uncoated. (vi) All the concrete / masonry pedestals present on the roof, constructed for supporting the water tanks or pipe lines or dish antenna/solar panel, etc., also should be coated with extra coat of same material incorporating reinforcing fabric. (vii) Allow the system to air cure for 7 days prior to carry out ponding test.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 120 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
S & F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25 mm X 3 mm aluminium strip complete all as specified and as directed.
S & F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 mm X 6 mm galvanised mild steel strip complete all as specified and as directed.
Supply and fixing testing , connecting, charging and commissioning of poly Crystalline silicon power module, with minimum 335 Wp, MNRE approved Indigenous and module mounted in anodised aluminium frame with twin wall profile structure all as specified and as directed by Engr-in-Charge. Note- Mounting structure along with foundation will be measured and paid separately (A) PV MODULES The PV modules must conform to the latest edition of any of the following IEC/equivalent BIS Standards for PV module design qualification and type approval: Poly Crystalline Silicon Terrestrial PV Modules:IEC61215/IS14286/ Equivalent IS (if available as on last date of receipt of tender) In addition, the modules must conform to IEC 61701 Salt mist corrosion testing, IEC 62804- Certification for PID resistance ,IEC61730Part1- requirements for construction &Part2-requirements for testing, for safety qualification or Equivalent IS(if available as on last date of receipt of tender) (B) Each PV module must use a RF identification tag(RFID),which must contain the following information:(i) Name of the manufacturer of PV Module (ii) Name of the Manufacturer of Solar cells(iii) Month and year of the manufacture(separately for solar cells and module) (iv) Country of origin (separately for solar cells and module)(v) I-V curve for the module(vi) Peak Wattage, Im, Vm and FF for the module(vii) Unique Serial No and Model No of the module(viii)Date and year of obtaining IEC PV module qualification certificate (ix) Name of the test lab issuing IEC certificate (x) Other relevant information on traceability of module as per ISO 9000 series. Note: RFID shall be mandatorily placed inside the module laminate. (C) Silicon Poly Crystalline SPV cells shall be used in the Solar Photo voltaic module. SPV cells used in the module shall essentially be indigenously manufactured (manufactured in India) of proven ability. Besides this SPV modules should also be essentially indigenously manufactured (manufactured in India). The make of SPV shall be Vikram Solar/ Tata Solar/Adani/RenewSys/NOVASYS (D) The module efficiency shall be more than 16% at standard test condition and the cell should have minimum fill factor of 0.7 with anti-reflective coating. It shall be made of high transmittivity glass & front surface shall give high encapsulation gain. Note: Anti dust coating on PV modules shall be done at site in the presence of Engineer-in Charge. (E) All materials used shall have a proven history of reliability and stable operation in external applications. It shall perform satisfactorily in relative humidity upto100% with ambient temperatures between -4°C and +60°C and shall withstand gust upto 200km/h on the surface of the panel. Each and every SPV module shall be checked for conformity with relevant standard and no negative tolerance shall be accepted. (F) Module and solar cells shall be manufactured in India irrespective of any other provisions in this tender. Module shall be made up of poly crystalline silicon cells. (G) The interconnected cells shall be laminated in vacuum to withstand adverse environmental conditions (H) The module frame will be made of corrosion resistant materials having aluminium anodized finish (I) PV modules used in solar power plants/ systems must be designed for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. PV modules shall have product warranty of 10 years after completion of work.
Supply and fixing of Non Penetrating Module Mounting Ballast roof system. Module mounting structures shall meet the following specification: (a) Hot dip galvanized (85 microns) MS mounting structures to be used for mounting the modules/ panels/arrays. (b) The mounting structure steel shall be as per latest IS 2062: 1992 and galvanization of the mounting structure shall be in compliance of latest IS 4759. (c) Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts. (d) Each structure should have angle of inclination as per the site conditions to take maximum insolation. However to accommodate more capacity the angle inclination may be reduced until the plant meets the specified performance ratio requirements. (e) The Mounting structure shall be so designed to withstand the speed for the wind zone of the location where a PV system is proposed to be installed (180 km/ hour). It may be ensured that the design has been certified by a recognized Lab/Authorized chartered Engineer/Reputed Institution in this regard and submit wind loading calculation sheet to client. Suitable fastening arrangement should be provided to secure the installation against the specific wind speed. (f) PV modules shall be secured to support structure using screw fasteners and/or metal clamps. Screw fasteners shall use existing mounting holes provided by module manufacturer. No additional holes shall be drilled on module frames. Module fasteners/clamps shall be adequately treated to resist corrosion. (g) The PV array structure design shall be appropriate with a factor of safety of min. 1. (h) Adequate spacing shall be provided between any two modules secured on PV array for improved wind resistance. (i) The fasteners used should be made up of stainless steel. The structures shall be designed to allow easy replacement of any module. The array structure shall be so designed that it will occupy minimum space without sacrificing the output from the SPV panels. (j) Regarding civil structures the bidder needs to take care of the load bearing capacity of the roof and need to arrange suitable structures based on the quality of roof.
(k) The structures should be suitably loaded with precast concrete blocks of appropriate weight made out of M20 concrete mixture. Waterproofing shall be provided in the areas where PCC blocks are placed on the terrace. (l) The total load of the structure (when installed with PV modules) on the terrace should be less than 60 kg/m2. The load shall be well distributed so that point loads are well within the limits. (m) The minimum clearance of the structure from the roof level should be sufficient to allow ventilation for cooling, also ease of cleaning and maintenance of panels as well as cleaning of the terrace. (n) The array shall be located sufficiently inside the boundary wall of the terrace (parapet wall) and should not be projecting out. PV array shall be installed in the terrace space free from any obstruction and/or shadow. PV array shall be installed utilizing optimum terrace space to minimize the effects of shadows due to adjacent PV panel rows. (o) Adequate spacing shall be provided between two-panel frames and rows of panels to facilitate personnel protection, ease of installation, replacement, cleaning of panels, and electrical maintenance. (p) Size of ballast 300x400x150mm. Weight of Concrete ballast not less than 40 Kg. (q) Warranty of MMS 10 years, Service life 25 Years, any defect arises with in 24 Months part of the structure to get replaced at venders cost. MAKE: STOLER / SRPL / ARS SOLAR STRUCTURE. Note: The fabrication and fixing of Module mounting structure shall be carried out by the manufacturer authorized agent only, as approved by the GE. For this purpose contractor shall submit the details of approved authorised persons along with supporting documents to GE well in time and the work shall be executed only, after written approval of GE. The main contractor and manufacturer shall give Warranty of Module mounting structure for 10 years and Service life of 25 Years. The manufacturer will give a certificate that the Module mounting structure will withstand the wind speed of 180 km/ hour.
Supply and laying cable in trenches or fixed on structure on wall floor ceiling etc of power control cables single core double insulated solar cable with fine copper wire multistranded, single core 4 Sqmm FLX- SOL -XL type, Tuv certified according to latest regulations -40°C to +120°C (permanent) UV, ozone and hydrolysis-resistant including all accessories and fixing arrangement complete all as specified and as directed. (in Solar Panels) Make: Siechem, Lapp, Polycab.
Supply installing, testing & commissioning DCDB box comprising of 8 incoming, 8 outgoing complete with fuses, connector, SPD, isolator in polycarbonate box IP65.
STRING TYPE INVERTER: Supply, Installation, Testing & commissioning Grid connected solar inverter of 50KW AC capacity microprocessor based having following specifications: - (i)Ambient temp: 4° C to 60° C (ii) Relative humidity: 0-100 % non-condensing (iii)Environmental condition: outdoor, wet location (iv)Protection degree: IP-65 (v)Pollution degree: IV (vi)Safety class: class I metal enclosure (vii)MPP Tracker 2MPP trackers (viii)No. of inputs minimum 4 Nos MC4 (ix)Frequency rated: 50 Hz (x)Total Harmonic distortion shall be less than 3% (xi)Power factor shall be more than 90% at any load (xii) Inverter Efficiency >93% (In case of 10 KW or above with inbuilt galvanic isolation) >97% (In case of 10 KW or above without inbuilt galvanic isolation) >90% (In case of less than10 KW) (xiii) External communication: RS-485 Port (xiv) Grid frequency Tolerance range +3 or more (xv) No load losses less than 1% (xvi) Protection against DG set run & grid isolation Note: - Inverter shall be capable of synchronisation with grid supply and DG Set supply. Make (DELTA, STRUDER, Schnider, ABB) INPUT (DC)- M50A Max recommended PV module- 63kWp, Max input voltage-1100 Volts, DC voltage range -200-1000 Volts, Start-up voltage >250 Volts, Start-up power -40 Watt, MPPT voltage range -200-1000 Volts, MPP voltage range full power -520-800 Volts, Nominal DC voltage -600 Volts, Max input current (total MPPT 1 /MPPT 2)- 100 Amp (50 Amp/50 Apm), Max short circuit current total (MPPT 1/MPPT 2)-120 Amp (60 Amp/60 Amp), Nos of Independent MPP tracker -2 Nos, Nos of DC input -12 , Max asymmetry -60/40%: 40/60% Input connection type - Multi connect MC4, DC connect switch -Yes (inbuilt) Output (AC) Nominal put power -50kVA, Max output power -55 kVA, Output current -80 Amp, Nominal output current -73 Amp, Max output current - 80Amp, Nominal AC voltage - 3 Phase 400 Volts, AC voltage range - 400 Volts plus minus 20% or 320 to 480 Volts, Nominal frequency -50hz, Frequency range - 50Hz plus minus 10%, Power factor at rated power - Unity, Reactive power (Adjustable) -0.8 Lagging, Total harmonic Distribution - < 3% Rated power, DC injunction <0.5% rated current, Nos of conductor - 4/5 wire (L1, L2, L3, N, PE), Output connection type - Amphenol Connector
Supplying, fixing and testing of zero export device and DG controller panel suitable for 2 Nos of 500 kVA DG sets and2 Nos of 50 kW solar invertor complete comprising of following: Type - DG & GRID EXPORT SOLUTION WITH REMOTE MONITORING FACILITY. Supply Voltage - 230 Volts AC ,50 Hz (UPS Supply), Operating temperature - 0-55 Degree Celsius, Humidity - 5% to 95 % non-condensing, Encloser protection - IP 54, Panel installation system - Base mount, Enclosure Material - mild steel , Enclosure type - Indoor, Shock - 15 G, 11 ms, Data logging - Applicable, MODBUS RTU BAUDRATE/PARITY&TCP/IP- Configurable, Nos of invertor - 02 Nos (50 KW each), Multi-function Metre, Class 1 with RS 485 Port - 03 Nos Make Schenider/secure/ L&T CT tape vound Class 1, 5 Volt Amp CT ratio as per user requirement - 09 Nos Make SEVERIOR/MDC/ AE RS 458 Surge suppressor SPD 2 wire - 01 No MAKE MERSEN,/ PHOENIX / CITEL HMI 7 inch -01 Nos - 01 No MAKE OMRON/SCHENIDER/DELTA, Data staton plus make REDLION/ MOXA/ ATOP, Single Mode Patch cord cable Make SANTELEQUP/ORING/ MOXA, LIBUX, Make: D-Link / Reputed/ ORING, RS 485 MODBUS Cable, 2 pair, SHELDED, Make - BELDEN/ POLYCABE/ PARASHIELD Single mode fiber cable, 4 core, Make - FINOLEX/ LAPP/ LEONI, Indication Light 230 VAC, Green for AC Supply, Make - L&T/Reputed/SCHINEDER, Indication Light 230 VAC, Green for DC Supply, Make - L&T/REPUTED/SCHINEDER, Power Supply 24VCD 4.5 A, Make-OMRON/DELTA/PHOENIX, DG/GRID Controller PLC, 1.80msec/Boolen, one RS232, one RS 484 serial port and with Ethernet port with power supply module, Make-GEIP/SCHENIDER/ EMERSEN/SRR, Industrial grade SCREEN 48 inches CPU with i5 processer, 7th generation CPU, 4GB RAM, 500GB hard Disc, Microsoft window 10, 64 bit, Professional addition, 1 LAN port, Make - HP/DELL/ADVANTECH/REPUTED, MCB, DP, 20A, 10 KA, Make - L&T/ABB/SCHENIDER, SMPS 21A, Make - OMROM/ PHOENIX/DELTA, Power socket 16A, Male - Anchor/ROMA/RIDER Powder coated enclosure box for controller panel IP 54, Make - SRR/Eldon/Rittal, Polycarbonate panel for Fiber Converter and LIU, Make - TRIBOX/FIBOX/GRASP
S & F Cable Connectors (MC4 male & female) 1000V (IEC/CEI),600V (UL), With safety clip that requires a tool to unlock (NEC2008 compliant) Certified for applications with modules according to IEC 61730, Safety class II, Directive 2002/95/EC on the restriction of the use of certain hazardous substances in electrical and electronic equipment -with Minimal voltage drop, High current-carrying capacity, Minimal power loss, Minimal contact resistance, High durability contacts withstand up to 1 million mating cycles, Operating temperatures up to 350°C,higher temperatures permitted for short periods complete all as specified and as directed.
Supply and fixing of Three in One WMS comprising of Radiation sensor, Cell Temperature Sensor, Ambient Temperature Sensor, RS 485 Communication complete with mounting arrangement. Make: IMT, Delta, Kipp and Jones.
S & F nominal 3.0 mm + 10% thick insulating mats made of elastomer conforming to IS-15652: 2006 and meeting the requirement of IS- 5216 (Part -1 & 2) IS 8437, IEC-479 Pub -1 along with suitable adhesive/ homebound, PV resin water proofing compound and sealing material as per recommendation of Annex 'A’, Clause- 'C’ of IS- 15652 and suitable for class - C upto 33 kV complete all as specified and as directed.
Supply and laying flexible DWC HDPE pipe ISI UV resistant in trenches under floor, wall etc 32 mm inner dia and 40mm outer dia.
M & L lightening arresters ESE type with 4 metres, mounting arrangement. Make: Protec, ASHLOK, ABB, Green Power.
M & L for Chemical earthing zinc coated safe earthing electrode (SEE) of 3 metres length with inner pipe of 40 mm dia with min 80-100 micron coating filled with black fill compound mixed with soil and high specific gravity crystallin conductive mixture (CCM) of grade 'B' filled inside the earth electrode including drilling of hole of 200mm dia bore with boring machine up to 15 metres depth in hard rock and filling the bore hole with black cotton soil up to 17 metres level i.e. below the electrode bottom level, including PCC earth pit and GI earth strip of 32x6 mm with GI tubing light grade for protection up to 7.5 metres complete all as specified and as directed. Make: ASHLOK, Protec, Green Power
Supply and installation, commissioning and testing of AC panel box 415 Volts grid panels outdoor type IP-65 for power evacuation and grid interconnection system, incoming 2 Nos 100 Amp MCCB outgoing 1 No 200Amp MCCB with copper busbar Grade to Electrolytic Grade E91 AL with current density 0.8A/mm^2, manufactured by CPRI approved manufacturer.
Supply and fixing of 10c x 1.5sqmm Copper Flexible cable
Supply and fixing of 2c x 1.5sqmm Copper Flexible cable
S& f ofsingle mode fiber optic cable (FOC) 4 core all as specified and directed. Make: FINOLEX / LAPP / LEONI
S& f of Communication RS 485 MODBUS cable size 2 x 2 x .5 Sqmm all as specified and directed. Make: SCHNIDER / EMERSEN / GEIP
Suppling only car washer portable type complete with machine hose gun, lance nozzle and water filter suitable for max. Pressure 120 bar and max flow rates 350 Litres / Hrs, 1500 Watt suitable for 230 Volt AC 50HZ power supply with cable length 50 metres and hose pipe length 30 metres all as per Bosch Car Washer CatLog NoAQT35-12 1500 Watt.
Note for all items: All items shall be executed as specified and directed by Engr-in-charge.
M K ENGINEERS CO.
Raja enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .