Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.8 LAccepted-AOC | L1 | Accepted-AOC work order has been awarded | |
| 2 | L2₹36.7 L+₹91,282.80 (2.55%)Rejected-Finance A 111 JHILMIL COLONY EAST DELHI 110095 | SHAHDARA | DELHI | 110095 | L2 | Rejected-Finance Not L1 |
Tender Value
₹41.9 L
EMD Value
₹84,000
Closing Date
5 Nov 2022, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE (EandM)/EDMC
Office of the Executive Engineer-(EandM)SSandSN Disaster Management Centre, Ghazipur, Delhi-96
Provision of lighting arrangement at SLF Ghazipur
2022_EDMC_133324_1
EE-EandM/EDMC//2022-23/13.1
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
90 days
work
Please refer to tender documents
4 documents required · 4 mandatory
₹1,000
₹84,000
29 Nov 2023
25 Oct 2022
7 Nov 2022
25 Oct 2022
5 Nov 2022
25 Oct 2022
Amount
Fabrication, supply of following size 11 mtr RCC/PSC pole with carbon steel based fabricaton of minimum tensile strenth of 200 kg. with botton width of minimum 415 mm and top width of minimum 225 mm, including all accessaries hook etc as required for laying of min 300 sq mm cable.
Supply and fixing of galvanized steel stay wire of size - 12 mm dia used for sustaining mechanical load of cable of minimum 3.5x300 sq mm cable size etc as required.
Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (100 mm X 110 mm),G. I. bolts, nuts and washers, coach screws etc. as required.
Erection of RCC/ PCC pole of following length in brick ballast and ramming thefoundation, finishing with 150mm thick cement concrete (1:3:6) layer on top withincluding excavation and refilling etc as required. Above 8.0 metre and upto 11.0 metre
Fabrication , Supplying,Installation,testing,Commissioning of 12 mts.high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick (Single dip ) inside and out sides and suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circumfrential weld. It should also included accessories For High Mast head frame ,2 point suspension system with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. flood light luminaries symmitrically And its control gears boxes and lighting finial ,the mast shall have integral manual type mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC(1:2:4) shallow foundation of size 1m(L)x1m wide and 2 mtr deep I/C excavation of earth , providing cutting,bending and placing in position ,reinforcement of cold twisted bars of 12 mm dia -2100 mm long(approx)-16 nos and reinforcement of cold twisted bar of 8mm dia -3700 mm(approx) -13 nos (with 150mm spacing) as reqd with positioning of foundation bolts and providing DWC HDPE pipe for cable entry or exit as required for the high mast considering the safe soil bearing capaciy at site as 10T/sqm at 2 mts .Depth with all material i/c 4 Nos S.P MCB ,63 A Dp Isolator etc as reqd Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS
Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh and grounding the protection system in suitable quality of CC etc as reqd.
supply of XLPE Insulated PVC Sheathed Al. Conductor Armoured Cable for working voltage upto 1.1kV confirming to IS-7098 of following sizes: (a) 2x10 sqmm
(b) 4 x 25 sq.mm
"SITC of 150w LED Flood Light luminiare fitted with lens, madeof pressure die cast aluminum housing & toughened glass cover complete with the following specification as reqd. (a) Total system wattage = 150 watt+/-5% (b) Total Lumens output>=15000 lumens (d) Luminaire Efficacy>=100 Lm/w (e) power factor>=.95 (f) Protection Class-IP-66
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sqmm FRLS PVCinsulated single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C
Supply of 250 mm (10") sweep 1250 RPM erxhaust fan, fresh air type complete with shutter blades etc as required.
SITC of surface mounting LED luminaire suitable for 1X20 watt LED rating box type complete with extruded aluminium batten prewired with high efficient LEDs with the following: a) Total System Wattage 20 ±5% Watt b) Luminaries effucacy ≥ 100 lumens/watt c) Power factor ≥ 0.95
"SITC of 350 W LED Flood Light luminiares having with high efficient LEDs and secondary Optics (PC lenses ), housing made of PDC with IP 66, 130 lumens per watt LED chip efficiency. PF > 0.95 , CCT 5700 K-6000K, Internal SPD > 5kV and external SPD = 10kV, Operating voltage rate - 100 v to 300 V , 50 Hz AC. TOTAL SYSTEM WATTAE 350+/-5%
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
S I T C of Hot Press moulded SMC panel/Canopy Box of size(OD) 920 mmx460 mmx260 mm & (ID) 900 mmx450 mmx250 mm , anti- corrosive, dust proof , rust proof, shock proof , Self-extinguishing property , resistant to heat, Vermin proof, Ultra Violet stabilized , Pilfer resistant, Suitable for mounting 1 no 3 phase Energy meter , socket for outgoing connection with pilferage proof SMC door duly welded with S/S handle having danger logo on its outer surface and with 1 no Hot Dip galvanized iron stand for base of size 40 mm x 40 mm x 5 mm and height of the stand is 600 mm including 300 mm height below the ground with side strip of size 25 x 5 mm
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 100 A, 16 KA,TPMCCB
125 A, 16 KA,TPMCCB
Supplying and fixing following rating, four pole, (three phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) 63 Amp.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way double door
8 way, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 2000x160x98mm (NS) complete with suitable arrangment for fixing of 1nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. ( Without MCB)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the exisiting surface/recessed steel/PVC conduit as required (a) 3x2.5 sq mm
(b) 3x4 sq mm
© 3x6 sq mm
Laying and fixing of one number PVC Insulated and PVC sheathed/XLPE cable of 1.1 KV grade of following size in the existing masonary open duct as required upto 35sqmm
M/S. A.K. Electricals
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .