Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹12.7 LAdmitted-Finance 2628 KUCHA CHALAN DARYA GANJ NEW DELHI 110002 | CENTRAL | DELHI | 110002 | L1 | Admitted-Finance | ||
| 2 | L2₹15.6 L+₹2.9 L (23.0%)Admitted-Finance 121 RANI DURGAWATI WARD NO 34 H S S SCHOOL SHOBHAPUR BETUL MADHYA PRADESH 460449 | BETUL | MADHYA PRADESH | 460449 | L2 | Admitted-Finance | ||
| 3 | L3₹15.8 L+₹3.1 L (24.3%)Admitted-Finance | L3 | Admitted-Finance | ||
| 4 | L4₹18.0 L+₹5.3 L (41.8%)Admitted-Finance C 5 156 YAMUNA VIHAR EAST DELHI DELHI 110053 | NORTH EAST DELHI | DELHI | 110053 | L4 | Admitted-Finance | ||
| 5 | L5₹19.1 L+₹6.4 L (50.3%)Admitted-Finance | L5 | Admitted-Finance |
Tender Value
₹17.4 L
EMD Value
₹34,740
Closing Date
20 Aug 2026, 3:00 pmClosed
Executive Engineer (E)
EEE PWD DHC and ND/Central G.F. MSO Bldg. ND
RMO Electrical , Mechanical Services in various Residential Building at Lok Niwas Marg , LG Secretariate under M-4512 (SH- SITC of Split type AC Units).
2026_PWD_297022_1
107/EE(E)/PWDDHC,ND/C/2026-27
Open Tender
Electrical Works
Works
30 days
New Delhi
Please refer Tender documents.
15 documents required · 15 mandatory
₹0
₹34,740
1 Sept 2026
14 Aug 2026
20 Aug 2026
14 Aug 2026
20 Aug 2026
14 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing and Commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz, 1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature).
Inverter Type - Hot & Cold
(a) 2. 0 TR with minimum 3 Star BEE Rating (Make:- Mitsubishi Heavy/ Mitsubishi Electric/O-General) | 15 | Nos. | 87,970 | ₹13,19,550 |
| 1.01 | Inverter Type - Cooling only
(b) 1.5 TR with 5 Star BEE Rating | 5 | Nos. | 43,539 | ₹2,17,695 |
| 2 | Supplying and fixing of M.S. outdoor, floor/ wall mounting powder coated stand suitable for 1.5/2.0 Ton capacity split type A.C. outdoor unit complete as required. | 20 | Nos. | 713 | ₹14,260 |
| 3 | Providing &Laying of refrigerant copper piping of size 1/4" or 3/8" & 5/8" diameter from indoor unit to outdoor unit of split type Air Conditioner unit along with 4 core 2.5 sq.mm PVC insulated and PVC sheathed flexible copper conductor cable including 20 mm size of cotton thread ribbed PVC flexible pipe from drip tray of Air Conditioner unit to drain pipe along with necessary support complete etc all as per Direction of Engineer-in-charge. | 150 | Meters | 934 | ₹1,40,100 |
| 4 | Supplying & drawing of 3x4 sqmm size of PVC insulated &pvc sheathed copper conductor round multicore flexible cable for indoor to outdoor and upto nearest power point i/c providing suitable copper lugs connection etc. as required. | 80 | Meters | 496 | ₹39,680 |
| 5 | Providing & fixing of 25 mm dia (SDR-13.5) UPVC heavy duty white colour drain pipe of with necessary fitting such as nipple, reducer, clamp on surface / recess i/c cutting the wall and making good the same complete as required. | 160 | Meters | 195 | ₹31,200 |
| 6 | Less for credit of following dismantle material under buyback arrangement etc. complete as required.
(a) 1.5/2.0 TR Split/Cassette AC | 4 | Nos. | 6,000 | ₹24,000 |
| 6.01 | (b) Copper Pipe/Wire (assorted) | 3 | Kgs. | 500 | ₹1,500 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.69 MB
BOQ_395585.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .