Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC | ₹18.2 L | L1 | Accepted-AOC L1 |
| 2 | L2₹19.1 LRejected-Finance | ₹19.1 L | L2 | Rejected-Finance L2 |
| 3 | L3₹19.2 LRejected-Finance | ₹19.2 L | L3 | Rejected-Finance L3 |
| 4 | L4₹19.3 LRejected-Finance | ₹19.3 L | L4 | Rejected-Finance L4 |
Updated dates
Tender Value
₹25.1 L
EMD Value
₹50,100
Closing Date
1 Dec 2025, 5:00 pmClosed
OSD(M)
YAMUNA EXPRESSWAY INDUSTRIAL DEVELOPMENT AUTHORITY
Operation and maintenance of Street Light for One year in pocket-I,Pocket-J and 24mtr wide Road in Sector-18 (Year 2025-26) YEA (WC-E,M-03)
2025_YEIDA_1090302_10
YEA/OSD(M)/2025/334 DT-06/11/2025
Open Tender
Electrical Works
365 days
YAMUNA EXPRESSWAY INDUSTRIAL DEVELOPMENT AUTHORITY
Please refer Tender documents.
5 documents required · 5 mandatory
₹841
₹50,100
4 Feb 2026
14 Nov 2025
3 Dec 2025
14 Nov 2025
1 Dec 2025
14 Nov 2025
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 140 to 150 Watt. Confirming to IP 66 Protection complete in all respects. P.S. 1425. Cat-AAA
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and above Protection complete in all respect. PS-1423 Cat-AAA
LED Driver suitabe for 135W-150W LED Street Light Driver Make Philips, Crompton, Bajaj, Complete in all respects as per direction of the Engineer-in-charge. Analysis rate
Supply & Fixing of 70-72W LED Street Light Driver Make Philips, Crompton, Bajaj,Complete in all respects as per direction of the Engineer-in-charge. Analysis rate
Supply & fixing Surge Protection Devices (SPD) 10kV/5kA Make Philips, Crompton, Bajaj,Complete in all respects as per direction of the Engineer-in-charge. Analysis rate
Supply & laying of Aluminium conductor, XLPE insulated, armoured served, sheathed cable 1100 V grade at a depth of 750mm below ground level over a cushion of 75mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the E/I, complete in all respect. old Cable Amount (scrap value 10% ) deducted in PS-501. (A) 4C x 16 Sqmm
Supply & laying of Aluminium conductor, XLPE insulated, armoured served, sheathed cable 1100 V grade at a depth of 750mm below ground level over a cushion of 75mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the E/I, complete in all respect. old Cable Amount (scrap value 10% ) deducted in PS-501. (A) 3.5C x 35 Sqmm
Supply & laying of Aluminium conductor, XLPE insulated, armoured served, sheathed cable 1100 V grade at a depth of 750mm below ground level over a cushion of 75mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the E/I, complete in all respect. old Cable Amount (scrap value 10% ) deducted in PS-501. (A) 3.5C x 50 Sqmm
Supply & laying of Aluminium conductor, XLPE insulated, armoured served, sheathed cable 1100 V grade at a depth of 750mm below ground level over a cushion of 75mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the E/I, complete in all respect. old Cable Amount (scrap value 10% ) deducted in PS-501 (B) 3.5C x 70 Sqmm
Supply & Fixing of XLPE insulated, Copper un-armoured Control cable 1100V grade etc. Complete in all respects as per direction of the Engineer-in-charge. make- CCI, Gloster, Asian, Universal, Nicco, ICL, Diamond, Havells & KEI YEIDA SOR-1 (a) 3C x 2.5 Sqmm
Supply & fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads, making connections etc. complete in all respects as per direction of the Engineer-in-charge. (PS-504). 16 Sqmm.
Supply, Delivery, Installation, Testing & Commissioning of Straight through cable jointing kit for L.T. PVC armoured cable jointing. Complete in all respects as per direction of the Engineer-in-charge.. (make Raychem, CCI, Forntec). (a) 4CX16 Sq.mm.
Supply, Delivery, Installation, Testing & Commissioning of Straight through cable jointing kit for L.T. PVC armoured cable jointing. Complete in all respects as per direction of the Engineer-in-charge.. (make Raychem, CCI, Forntec). (b) 3.5CX25/35/50 Sq.mm.
Supply, Delivery, Installation, Testing & Commissioning of Straight through cable jointing kit for L.T. PVC armoured cable jointing. Complete in all respects as per direction of the Engineer-in-charge.. (make Raychem, CCI, Forntec). (b) 3.5CX70 Sq.mm.
Supply & Fixing of PVC Insulation Tape 19/20mm 8Mtr Long.(Steel grip) complete in all respect, as directed by Engineer in charge. YEIDA SOR-44
Digging of Cable & relaid in same trench Complete in all respects as per direction of the Engineer-in-charge. Analysis of Rate
S/L of 90mm dia DWC pipe for drawing of power cable across the road by drilling of 120mm dia at 1 mtr. below the road level thereby doing the work of providing DWC pipe by Manual trenchless method. Complete in all respect per direction of Engineer-in-charge YEIDA SOR-12
Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. PWD-2018-807(F) 40 A TPN
S&F of 100 Amp, 4Pole Isolator. UPPWD-2018 P.S.-1007(C) Cat-A
S&F of 125 Amp 4 pole MCCB (16 KA) Thermal Magnetic release UPPWD-2018 P.S.-1021(A) Cat-A
S/F of 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 Mtr. below ground level complete with 20 mm dia G.I. pipe & funnel for watering & one earthing lead of one no. 8 to SWG GI wire in 15mm dia G.I. pipe upto switch board (from apron to switch board the cost of GI pipe and GI wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of char-coal/coke & salt atleast 150 mm thick all-around etc. as per direction of Engineer-in-charge complete in all respects. (PS-702)
Hire & running charge of Hydraulic ladder with Driver including cost of service charge of operating staff & Diesel/Petrol Complete in all respects as per direction of the Engineer-in-charge. Analysis of Rate
Electrician for operation & maintenance :- Electrician/ Operator with Kit -1, YEIDA- 50
Electrician for operation & maintenance :- Electrician/ Operator with Kit -2, YEIDA- 50
Repair of Transformer Incl. Changing of HV & LV Coil, Bushing, Gasket & Fresh Transformer oil without returnning of old & unsearciable material. as directed by Engineer in charge. (A) 63/100KVA Transformer
Dis./Re-errection of 63/100 KVA Al./copper wound outdoor type Transformer as per I.S. including fess as directed by Engineer in charge
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.27 MB
10.pdf
Tender Documents • 1.50 MB
BOQ_2002652.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid