Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹39.3 L+₹1.9 L (5.13%)Rejected-Finance 13 P N DOGRA MARKET GOLE MARKET UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance Being other than lowest bid | |
| 3 | L3₹39.4 L+₹2.1 L (5.52%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest bid | |
| 4 | L4₹40.2 L+₹2.8 L (7.56%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest bid | |
| 5 | L5₹41.1 L+₹3.7 L (9.97%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest bid |
Tender Value
₹49.9 L
EMD Value
₹99,820
Closing Date
24 Oct 2024, 6:00 pmClosed
GE North Udhampur
GE North Udhampur C/o 56 APO
PROVN OF ADDN / ALTN TO MT GARAGE NO. NP-12 OF 57 WEU, STONE MASONRY RETAINING WALL NEAR BLDG NO. P-06A, INTERLOCKING TILES IN FRONT OF IPC AND ADM OFFICE AT HQ DDG SI (NZ) AND 04 X MINOR WORKS UNDER AGE B/R-I OF GE (NORTH) UDHAMPUR
2024_MES_676826_1
GE/U(N)-58/2024-25
Open Tender
Civil Works
Item Rate
180 days
AOR of GE North Udhampur
Refer tender documents
7 documents required · 7 mandatory
₹500
GE North Udhampur
₹99,820
Yes
9 Dec 2024
26 Sept 2024
26 Oct 2024
26 Sept 2024
24 Oct 2024
10 Oct 2024
Amount
Dismantling asbestos cement (corrugated or semi corrugated etc.) sheetS as in roof covering including ridges, complete all as specified and directed.
S&F prepainted corrugated coloured profiled galvalume/ zinalume sheet with min 0.50mm TCT with BTM of 0.45mm thick conforming to IS-513 (AZ-150 GSM, AI zinc alloy metallic coating 550 Mpa as per AS-1397) with colour/ exterior top coat of silicon modified polyster/ BHPX RW paint system 20 micron top coat applied over 5 micron primer, as in roof coverings/ cladding to walls etc, fixed with galvanised self drilling, self tapping fastners of size 12-14mm x 55mm with EPDM seats, complete all as specified and directed.
S&F prepainted plain coloured profiled galvalume/ zinalume sheet with min 0.50mm TCT with BTM of 0.45mm thick conforming to IS-513 (AZ-150 GSM, AI zinc alloy metallic coating 550 Mpa as per AS-1397) with colour/ exterior top coat of silicon modified polyster/ BHPX RW paint system 20 micron top coat applied over 5 micron primer, as in roof coverings/ cladding to walls, valley gutters etc, fixed with galvanised self drilling, self tapping fastners of size 12-14mm x 55mm with EPDM seats, complete all as specified and directed.
Demolition of brick work or stone boulder masonry, built in cement mortor including all quoins, arches, pillars etc., complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
M&L for brick work with using sub class 'B' bricks, old size, straight or curved on plan exc 6 mtr mean radius, built in CM 1.6, complete all as specified and directed.
M&L for brick work with fly ash bricks, old size, straight or curved on plan exc 6 mtr mean radius, built in CM 1.6, complete all as specified and directed.
Taking down cement plaster on brick walls, stone masonry/ walls, concrete surfaces etc. including raking out joints, hacking for key, scrubbing down with water etc., complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces or stone masonry wall in CM 1:4 with using water proofing compound, finished the surface even and smooth without using extra cement, complete all as specified and directed. Note :- WPC shall be measured and paid separately under respective item of this BOQ.
M&L for 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6, finished the surface even and smooth without using extra cement, complete all as specified and directed.
Supply only integral water proofing compound.
M&L for preparation of new surfaces of walls and applying two coats of cement base paint over and including a coat of alkali resistant primer, complete all as specified and directed.
M&L for preparation of new surfaces of walls and applying two coats of oil bound distemper over and including a coat of primer and over and including 2-3mm thick wall care white putty, complete all as specified and directed.
Dismantling wall and ceiling boards, fibre, pulp, insulation etc.) or insulation boards/ slabs/ blankets of any thickness including cover fillets or MS/ aluminium grid/ frame, complete all as specified and directed.
S&F false ceiling with non asbestos fibre cement board of 4mm thickness of size 600mm x 600mm panel, designed ceiling conforming to IS:12862 to IS:14862 type 'B' in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanised @ 120 gms, both side inclusive) consisting of main 'T' runner with suitable spaced joints to get required length and 15x32mm made of 0.30mm sheet and cross at 600mm c/c to form a grid including required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detector etc. Main 'T' runners to be suspended from ceiling using GI soffit cleats fixed to existing rafter, purlins etc. with galvanised butterfly level clips, spaced at 1200mm c/c along main 'T', bottom exposed width of 15mm of all 'T' section shall be centra black prepainted with polyester paint and having a load bearing capacity of 12 Kg/Sqm and re-fixed all existing electric wiring and fixtures at any height, complete all as specified and directed.
S&F vitreous china wash hand basin of size 550mm x 400mm with full pedestal, white in colour, flat back including MS brackets or brass fastners of suitable size, 32mm dia CP brass coupling and waste pipe, cutting for and pinning in ends of brackets or erecting stand, complete all as specified and directed.
S&F chromium plated tubular towel rail, 20mm dia, 'D' type, 60cm long between flanges, fixed with CP screws, complete all as specified and directed.
S&F PVC connection of size 15mm with PTMT nuts of length 600mm, suitable for hot & cold water, complete all as specified and directed.
S&F 500 ltrs capacity rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), white colour, three layered, ISI Marked, hoisted and fixed in position with and including necessary GI fittings, complete all as specified and directed.
S&F ball brass valves, high pressure, with polythene float and flynut complete, screwed for 20mm bore iron pipe or brass ferrule, complete all as specified and directed.
M&L for 15mm bore GI water tubing, medium grade with all fitting and fixtures, fixed to walls or ceilngs or laid in floors, complete all as specified and directed.
M&L for 20mm bore GI water tubing, medium grade with all fitting and fixtures, fixed to walls or ceilngs or laid in floors, complete all as specified and directed.
S&F gun metal globe or gate valve with iron wheel head, screwed both ends for 20mm bore iron pipe, complete all as specified and directed.
S&F pillar tap, cast copper alloy with capstan head, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shank and fly-nuts, screwed for 15mm bore iron pipe, complete all as specified and directed.
Demolition of cement concrete (un-reinforced) as in ground floor, paving etc., not exc 15cm in thickness (below or above ground level), complete all as specified and directed.
M&L for 50mm thick PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregates) as in plinth protection including making joints 10mm wide and 30mm deep at spacing not more than 2.5 mtr and at corners as mandatory and filled with sealing compound grade 'A', finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for hardcore of broken stone or boulders of gauge not exc 63mm, deposited, spread and leveled in layers not exc. 15cm thick, watered and well rammed to a true surface, complete all as specified and directed.
M&L for hardcore of broken stone or boulders of gauge exc 63mmm but not exc 100mm, deposited, spread and leveled in layers not exc. 10cm thick, watered and well rammed to a true surface, complete all as specified and directed.
M&L for 75mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base, complete all as specified and directed.
M&L for 100mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base, complete all as specified and directed.
M&L for 60mm thick machine pressed cement concrete interlocking paver block, glossy finish, any shape and size, confirming to IS:15658-2006, M-35 grade, laid with grey cement and pigment, complete all as specified and directed.
M&L for precast cement concrete rubber moulded chequered coloured tiles of size 30cm x 30cm x 25mm thick, set in grey cement slurry, jointed and pointed in grey cement with pigment as in floors, fixed over and including 20mm thick screed bed or bedding layer in CM 1:4, complete all as specified and directed.
M&L for sand cushioning under paver blocks including spreading, leveling, watering if required or underground cable provided with a layer of sand of 8cm thick before laying the cable and 15cm thick after laying cable and stretching the cable, complete all as specified and directed.
M&L for precast cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in kerb stones and in similar works, bedded and jointed in CM 1:4 with matching joints, complete all as specified and directed.
M&L for factory made precast cement concrete 1:2:4 type B-0 kerb stones of size 300mm in width, 100mm thick & 350mm in depth, bedded and jointed in CM 1:4 with matching joints, complete all as specified and directed.
M&L for 150mm thick plain cement concrete 1:2:4 type B-2 (using 40mm graded crushed stone aggregates) as in floors or sub base, complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description and in any position, complete all as specified and directed.
Taking down roof trusses, coupled rafters or trussed beams, clear span 8-12 mtr, complete all as specified and directed.
M&L for mild steel work as in stair case, roof trusses (framed), trusses, purlins, crane ganttries, rails and fastering and heavy brackets framing (beam, tee, angle, channel or flat sections) and including distance piecess, cleats etc, conforming Fe-410W (Gde-E-250, Quality - A), complete all as specified and directed.
M&L for mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS:1161-1979 grade St-240, complete all as specified and directed.
M&L for mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, conforming Fe-410W (Gde-E-250, Quality - A), complete all as specified and directed.
S&F stop valve/ angle valve, chromium plated, cast copper alloy, screwed down, high pressure with crutch butterfly handle, screwed both ends for 15mm bore iron pipe or for unions, complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc, complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in surface channels and drains etc, complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings and the like including weathering, slightly rounded or chamfered angles, throating and including necessary formwork, complete all as specified and directed.
M&L for reinforced cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed.
M&L for reinforced cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in beams, cantilevers, bressummers, lintels, over 1.5 mtr clear span, complete all as specified and directed.
M&L for reinforced cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in columns, pillars, piers, posts and struts, complete all as specified and directed.
M&L for reinforced cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in chajjas and the like, complete all as specified and directed.
Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in any type soil, complete all as specified and directed.
Add to or deduct from serial item No. 50.00 here-in-above, for every 3cm or part thereof above or below 15cm average depth, complete all as specified and directed.
Excavating in post holes (or similar holes) each, not exceeding 0.50 Cum and getting out in any type of soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm thick and removing surplus soil to a distance upto 50 mtr from site, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, shaft, wells, cesspits, manholes, laying of pipe/ cables etc. and getting out in any type of soil, complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25cm thick, complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.50 mtr above the starting point, complete all as specified and directed.
Removing excavated material (soil) to a distance exc 250 mtr but not exceeding 500 mtr and deposited where directed, complete all as specified and directed.
M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in foundation, filling in and mass concrete etc., complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in foundation, filling in and mass concrete etc., complete all as specified and directed.
M&L for preparation of new steel or iron surfaces of any description, exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed.
M&L for preparation of old steel or iron surfaces of any description, exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed.
M&L for preparation of new concrete or plastered surfaces of any description, exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer, complete all as specified and directed.
Rough excavation not exceeding 1.5 mtr deep and getting out in any type of soil, complete all as specified and directed.
Excavating over areas, not exc 1.5 mtr deep and getting out in any type of soil, complete all as specified and directed.
M&L for walling of random rubble stone masonry, uncoursed, well bounded, bedded and solidly hearted, built in CM 1:6 as in retaining wall, drains etc., complete all as specified and directed. Notes :- (a) If work executed in retaining wall, PCC bond stone shall be measured and paid separately under respective item of this BOQ. (b) Weep holes in retaining shall be provided.
M&L for preacst cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregates) as in bond stones, set in CM 1:6, complete all as specified and directed.
Extra over stone walling for hammer dressing (dressing with maximum depression on face from straight edge held against the dressed surface not exc 40mm granite or trap stone) to face stones and dressing of face beds and joints of random rubble stone walling, uncoursed or brought upto courses, complete all as specified and directed.
M&L for hand packing with broken stone or boulders (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level, complete all as specified and directed.
S&F 110mm bore PVC pipe of low density of pressure rating 10 KG/Sqcm, in short length, fixed in weep holes of retaining wall, complete all as specified and directed.
M&L for raised pointing to RR masonry in CM 1:3, complete all as specified and directed.
Forming embankments including raising (or lowering) earth, spreading in layers not exc 30cm thick, watering, ramming/ rolling and finishing to required size, shape etc., not exc 1.5 mtr high from base, complete all as specified and directed.
All as per serial item No. 70.00 here-in-above but height exc 1.50 mtr and not exc 3.0 mtr.
All as per serial item No. 70.00 here-in-above but height exc 3.0 mtr and not exc 4.5 mtr.
S&F 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap, fixed with coach screw and washer in roof, wall etc, complete all as specified and directed.
S&F TMT mild steel bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
S&F TMT Mild steel bars 6-8mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends or as in stirrups and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Formwork to rough finished edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide, complete all as specified and directed.
Formwork to rough finished concrete surfaces and soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping), complete all as specified and directed.
Formwork to rough finished concrete surfaces of chullah hoods, chajjas, troughs and similar work including edges, complete all as specified and directed.
Formwork to rough finished concrete surfaces to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc. also splays between floors and beams etc, complete all as specified and directed.
Formwork to rough finished concrete surfaces of spiral staircase with sloping or stepped soffits, including risers and stringers, complete all as specified and directed.
M&L for repair wooden flooring, size of panel 1215mm x 195mm with thickness 8.3mm, direct pressure laminated according to EN-13329 for glueless installation, heavy domestic and light commercial use as EN-13329 level of 22 including under layer of 2mm thick EP and polythene layer, complete all as specified and directed.
M&L for mirror polished 18-20mm thick granite stone slabs, machine cut, bedded and jointed with grey cement slurry and pointing in white cement with admixture of pigment to match with shade of granite, fixed as in steps, jambs, pillars, window cills, cooking plateforms and the like including rounding and edging, fixed/laid over and including 15mm thick screed bed/ plaster in CM 1:4, complete all as specified and directed.
Taking down carefully existing copper / aluminium point wiring of any size and type by disconnecting from the either terminals complete with switches, sockets, ceiling roses, regulators, bell, fan regulators etc. by unscrewing and removing materials to store for keeping in safe custody for re-use or for taking credit and making good disturbed surface of walls, floors to match with existing surfaces, complete all as specified and directed.
M&L for point wiring with PVC insulated unsheathed, FRLS 1100 volts grade, stranded copper conductor cable, single core 1.5 Sqmm for one light / fan point, controlled by one way switch and wire to be drawn in and including rigid PVC concealed conduit of dia not less than 20mm of 2mm wall thickness complete with all accessories including GI annealed metal box 1.2mm thick sheet of suitable size, fixed as flush wall with and including 3mm thick ebonite sheet cover and necessary screws, cap washers etc. or to be fixed on wall respectively as directed and providing earth continuity wire using PVC insulated unsheathed single core stranded copper conductor FRLS cable of size 1.5 Sqmm, complete all as specified and directed.
All as per serial item No. 84.00 here-in-above but for 3/5 pin 5 Amps socket outlet on same board with other switches.
All as per serial item No. 84.00 here-in-above but for one 3/5 pin 5 Amps socket outlet on independent board.
All as per serial item No. 84.00 here-in-above but for 3 pin 15 Amps socket outlet with wire and continuity wire of size 2.5 Sqmm FRLS PVC insulated unsheathed, 1100 volts grade, stranded copper conductor, complete all as specified and directed.
S&F switch piano, flush type, one way, single pole, 5 Amps, complete all as specified and directed.
S&F socket outlet, 2 in 1, 3 pin, 5 Amps, flush type, complete all as specified and directed.
S&F switch socket combination, 2 in 1, 3 pin, 5/15 Amps, flush type, complete all as specified and directed.
S&F electronic fan regulator, stepped type, 230/240 Volts, suitable for 1200/1400mm sweep ceiling fan, complete all as specified and directed.
S&F ceiling rose, 3 terminal, PVC / polycarbonate isolated body, complete all as specified and directed.
S&F slim linear LED lighting fixture 20 Watt LED batten with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver complete making all connection using 1.5 Sqmm copper conductor multistandard PVC insulated 2 Core flexible cable with flexible PVC pipe from ceiling rose to fittings including taking down old one, complete all as specified and directed.
S&F E-Lite LED Curve lighting fixture 10/12 Watt LED batten with full base of extruded polycarbonate body environmental friendly, energy efficient ready to use pack with isolated driver complete making all connection using 1.5 Sqmm copper conductor multistandard PVC insulated 2 Core flexible cable with flexible PVC pipe from ceiling rose to fittings including taking down old one, complete all as specified and directed.
S&F in replacement LED street light fitting 35 Watt, 230 Volts, AC, outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-65/66 protection, complete all as specified and directed.
S&F in replacement submain wiring with copper conductor cable (2 runs of cable) multistranded of size 6.0 Sqmm PVC FRLS with all insulated unsheathed in and including PVC concealed conduit of 25mm dia, medium grade and including fittings and 1 Run X 6.0 Sqmm copper conductor cable PVC insulated unsheathed multithreaded using as continues earth wire, connected to common earth and earth dolly, complete all as specified and directed. Note :- Two run of 6.0 Sqmm and one run 6.0 Sqmm cable with one run of PVC conduit shall be measured as one unit.
S&F in replacement single pole and neutral steel sheet powder coated distribution board for MCBs fitted with bus bar, neutral link, earth bar and din rail, suitable for use on 240 Volts, 50 Hz supply, double door, SPN DB system, 8 Ways, complete all as specified and directed.
S&F in replacement MCB 40 to 63 Amp, SPN, 'C' series, 240 Volts, 50 Hz, 10 KA and other domestic loads including all terminals, fittings etc, complete all as specified and directed.
S&F in replacement MCB, SP, 6-32 Amps, 'C' series, 240 Volts, 50 Hz, 10 KA, complete all as specified and directed.
S&F in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps, 240 Volts, complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to earth lead by means of bolts nuts and washers of GI and including earthing pit charcoal, common salt, GI 4mm dia lead wire with 20mm GI medium grade watering pipe and 15mm bore light grade protection pipe upto 5 mtr length with wire mesh and funnel, PCC pit in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates), angle iron frame and RCC cover and earth work, complete all as shown in electrical plate No. 3 of SSR-2009 (Part-1) and directed.
Supply, laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 2 Core, laid in trenches/ floor/ pole/ GI pipe complete including cutting/ chasing to any surface and making good to the disturbed surface to match with existing surface, complete all as specified and directed.
Supply and laying brick, sub class ‘B’, old size, well burnt as covering as mechanical protection to UG cable, complete all as specified and directed.
M&L for 40mm bore GI tubing, light grade with all fitting (as required) and fixed to walls/ poles with suitable MS clamps or laid in floors, complete all as specified and directed.
S&F ceiling fan complete with blades, down rod, electronic regulator and accessories, 230 Volts, 1200mm sweep, minimum air delivery 210 CFM with service value 6.0 BEE, 5 Star rated with brushless direct current motor (BLDC), complete all as specified and directed.
S&F ceiling fan complete with blades, down rod, electronic regulator and accessories, 230 Volts, 1400mm sweep, minimum air delivery 245 CFM with service value 6.0 BEE, 5 Star rated with brushless direct current motor (BLDC), complete all as specified and directed.
S&F exhaust fan, steel body, heavy duty, AC, single phase with suitable capacitor, 230 Volts of size 300mm sweep with 4 Nos blades, frame, four arms and steel louvers, complete all as specified and directed.
S&F exhaust fan, steel body, heavy duty, AC, single phase with suitable capacitor, 230 Volts of size 450mm sweep (1400 RPM) with 4 Nos blades, frame, four arms and steel louvers, complete all as specified and directed.
S&F exhaust fan, PVC body, AC, single phase with suitable capacitor, 230 Volts of size 250mm sweep with frame and louvers, complete all as specified and directed.
S&F wall mounted fan, V3 Model, anti dust proof, size 450mm sweep, steel body/ frame, AC, single phase, 230 Volts, 3 blades, adjustable upward and downward tilt mechanism, oscillation type, glossy finish, complete all as specified and directed.
S&F pedestal fan, V3 Model, size 450mm sweep, steel body, AC, single phase, 230 Volts, 3 blades, glossy / metallic finish, complete all as specified and directed.
S&F electronic meter, temper proof LCD display with polycarbonate cover 230 Volts, 10-60 Amp, accuracy class-I, 50 Hz, conforming to IS-13779, IP-54 with parameters to show data, time, current reading, load, PF, voltage and KWH with and including meter box, complete all as specified and directed.
M&L for point wiring for one light point, controlled by one switch one way with 1.5 Sqmm (nominal area) PVC insulated unsheathed, multistranded, FRLS 1100 volts grade copper conductor cable in and including concealed PVC conduit 20mm dia, medium duty, ISI Marked and anealed mild steel sunken box (module as per site requirement) with modular frame and modular cover plate of required module, flush in the wall surface and including earth continuity wire using PVC insulated unsheathed single core multistranded copper conductor FRLS cable of size 1.5 Sqmm, complete all as specified and directed.
All as per serial item No. 113.00 here-in-above but for one ceiling fan, controlled by one switch on independent board.
S&F modular switch, one way, 5/6 Amps, 230 Volts, AC, complete all as specified and directed.
S&F modular electronic fan regulator, stepped type, two module, 120 Watt, 230 Volts, complete all as specified and directed.
S&F in replacement decorative ultra slim linear LED lighting fixture 10/12 Watt LED and making all connection using 1.5 Sqmm copper conductor multistandard PVC insulated 2 Core flexible cable from ceiling rose to fittings by using extra length other than provided by manufacturer, complete all as specified and directed.
S&F LED 9/10 watt post top lantern bollard bamboo light, new generation, energy saving environment friendly, long life, aesthetically designed, pressure die-cast, poweder coated housing with PC diffuser, efficient with high output LED with IP-65 protection, suitable for garden ways and heritage sites and including necessary electric connection, complete all as specified and directed.
S&F factory made MCB metallic distribution board, 6 Way, 230 Volts, concealed flush to wall for mounting MCBs, conforming to IS:13032, fabricated out of CRCA sheet, fitted with DIN channel, neutral link and appropriate rated bush bar. DB shall be semi glossy finish with epoxy polyster based powder paint, sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. DB shall be double door type with hinged door and locking arrangement and shall also be provided with lable marking indicating the incoming and outgoing circuits on all ways and have IP-43 protection, complete all as specified and directed.
Supply, laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 Sqmm 2 Core, laid in trenches/ floor/ pole/ GI pipe complete including cutting/ chasing to any surface and making good to the disturbed surface to match with existing surface, complete all as specified and directed.
VARDHMAN INTERNATIONAL (BID ID -3142501)
JOGINDER SINGH (BID ID -3141959)
takashdeep traders (BID ID -3149276)
s l sharma and sons (BID ID -3148605)
pargal builders (BID ID -3142437)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .