| 2 | Not Admitted-Fee/PreQual/Technical D2 ANAND APARTMENT 72 3 NEHRU 100 FEET ROAD VADALAPANI CHENNAI 600026 | CHENNAI | CHENNAI | TAMIL NADU | 600026 | - | Not Admitted-Fee/PreQual/Technical Others-Bidder not enclosed the experience solvency and user certificate current AMC copy order test report for cleanroom validation documents not duly attested by notary/gazette officer AS PER REQUIREMENT | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Others-bidder not enclosed registration experience solvency and user certificates current AMC copy order test report for cleanroom validation as per requirements Document submitted by the tenderer is not duly attested by the Notary public/Gazetted officer |
Tender Value
₹65 L
EMD Value
₹65,000
Closing Date
11 Apr 2022, 5:00 pmClosed
DEAN, VCRI, ORATHANADU
DEAN, VETERINARY COLLEGE AND RESEARCH INSTITUTE ORATHANADU THANJAVUR (TN)
As per BOQ
2022_TNVAS_227484_1
1498_VCRI_VPT_OND_MAR_2022
Open Tender
Electrical Works
Turn-key
180 days
VCRI, ORATHANADU
REFER AS PER THE TENDER SCHEDULE
8 documents required · 8 mandatory
₹0
₹65,000
27 Jun 2022
28 Mar 2022
12 Apr 2022
28 Mar 2022
11 Apr 2022
28 Mar 2022
Amount
Air Handling Unit facilities: Air Handling Unit: Double skin, >40mm PUF panels made of pre-coated sheets (0.6mm thick) GI inner skin & precoated outer skin with aluminum sectional frames thermal break profile, 6-Row copper cooling coil, provision for HEPA filters, HEPA filter integrity Test, pre-filters, fresh air arrangement etc. to achieve Class 100000 cleanliness, Motor-Blower: High Static blower (100mm wG) with backward curved, balanced, impeller of Kruger make (Imported), with heavy duty Motor + 1 standby Motor, Belt-pulley (taper-lock) drive package, special AHU kit for Inverter ACs, Magnehelic Gauge to read HEPA filter pressure drop etc The AHU shal have 3 sections such as Coil section, Blower section, Filter section apart from mixing box and Fresh Air filter arrangement, including MS support structure, wall mount etc for AHU stand/pedestal as required Air Handling Unit 01 : 3200 CFM (Tablets Area)
Air Handling Unit 02 : 2300 CFM (Liquid Area)
Air Handling Unit 03 : 1650 CFM (Ointment Area)
Air Handling Unit 04 : 5000 CFM (Corridor Area)
Air Conditioner: Air Cooled, DX condensing Unit with scroll compressor duly commissioned with Copper Piping (10 mtrs per circuit), Expansion valve, N2 pressure testing, Vacuum holding, gas charging etc as per industry standards Make: BLUESTAR / VOLTAS/O’ General 5 Ton of Refrigeration Condensing Unit (Inverter type) (Area: Tablet)
5.5 Ton of Refrigeration Condensing Unit (Area: Tablet)
8 Ton of Refrigeration Condensing Unit (Inverter type) (Area: Liquid)
5 Ton of Refrigeration Condensing Unit (Inverter type) (Area: Ointment)
11 Ton of Refrigeration Condensing Unit (Area: Corridor)
High Efficiency Particulate Air filters (HEPA): to filter 0.3 micron and larger particles at >99.97% efficiency to be installed in each of the AHU with all provisions for HEPA filter integrity test at the Site, as part of onsite Validation to meet Drug Control & NABL requirements.Capacity of HEPA filter should match or exceed AHU capacity
Pre-filters: for particles in the range of 10 microns & 5 microns – non-woven fabric, cleanable media with aluminum support mesh; to match AHU capacity. One Set of spare filters to be supplied.
Ducting: Factory fabricated GI rectangular duct, as per IS standards complete with leak free flange joints, epdm / eq gaskets, sealant as required, GI fasteners and support from RCC roof using anchor fasteners, threaded rods & MS angles / GI sections. Pressure test of ducts as per standards.24G (0.6mm)
Insulation: Ducts insulated with closed cell, Class 0, Nitrile foam using suitable adhesive and all joints sealed with adhesive tape Supply Air ducts with 13mm thick
Return Air ducts with 9mm thick
Volume Control Dampers and Fire Dampers Volume control (GI) duct Dampers with opposed vanes and handle for manual operation with markings partial opening & control
Fire Dampers with fusible link to close in case of fire installed in Supply & Return Ducts including limit switch control to turn Off AHU in case of fire
Supply Air Diffusers made of Aluminium extruded sections with GI collar dampers at the neck
Return Air Grills made of Aluminium extruded sections with GI collar dampers
Electrical Work: Individual Control panels for each AHU system typically comprising of Contactors, OLRs, SPPs, MCBs etc for each AHU system; Cabling & earthing from our Control Panel to the AHUs & Condensing Units including control wiring, Thermostat & Electrical Strip Heaters (3kW in each AHU), Humdistat etc (incoming wiring with suitable Earthing upto Control Panels will be TANUVAS scope) Additional dedicated earthing for HVAC equipment shall be provided.
Magnehelic Gauge with fixtures, probe and tubing for all the rooms for reading pressure differentials
Installation, Commissioning including DQ-IQ-OQ documentation
Validation (AHU wise & Room wise) a. HEPA filter integrity test (PAO test) including consumables such as Nitrogen Cylinder b. Room Particle count to check the Cleanliness level as per US Federal Std. 209E c. Air Velocity measurement, Checking AHU capacity & Air Changes per Hour of systems d. Lighting in each room e. Room Positive Pressure balancing and setting pressure gradient as required f. Temperature & Relative Humidity
SYSTEM II: Clean Room Interior Work: Modular, EPS insulated Clean Room Wall Panels of 10ft Height (>60mm thick) with both sides 0.55mm thick PPGI with PVC conduits inserted, floor track, Coving provision, guard film, cutouts, flashing, supports from RCC roof using threaded rods & turn-buckle & finished with silicone sealant as required
Modular, EPS insulated Clean Room Ceiling Panels (>60mm) with both sides 0.55mm thick PPGI sheets complete with guard film, cutouts, flashing, supports from RCC roof using threaded rods & turn-buckle & finished with silicone sealant etc as required
Coving: Aluminium sections to round off 90º joints between wall ceiling-floor
Corner Coving: Die cast aluminium coving for corners
Clean Room Doors: Metallic powder coated with double glazed View panel; door closer (DORMA/Godrej), SS handle, SS ball bearing hinges etc 'D' Size: 1.2 x 2.1m
Clean Room Doors: Metallic powder coated with double glazed View panel; door closer (DORMA/Godrej), SS handle, SS ball bearing hinges etc 'D1' Size: 1.0 x 2.1m
Emergency Exit & Machine Movement Door: Double Door, Metallic powder coated (in Red) with door closer (DORMA/Godrej), SS handle, SS ball bearing hinges, latch, Panic bar & Audible/visual alarm etc 'D2' Size: 1.5 x 2.1m
Door Interlocking arrangement for Change Room Doors complete for 2 doors with EM locks, interlock electronic circuit, LED status indicator etc
Double Glazed View Panels: with aluminium frame, toughened glass (5mm) both sides with adhesive tape and finished with silicone sealant Size: 600 x 900 mm
Wall Coating - 2 finish coats of Polyurethane (PU) paint after primer and putty work on the existing walls up to of 10ft Height from floor. PU paint is washable, cleanable, antifungal & non-VOC type suitable for pharma application.
SYSTEM III: Clean Room Equipments : Dynamic Pass box: Fully SS 304 twin door, electromagnetic interlocking, UV lamp, LED Light, HEPA filtration, Centrifugal Blower, Minihelic pressure gauge, SS pipe floor support; Inner Size: 24” x 24” x 24”
Static Passbox: Fully SS304, twin door, electromagnetic interlock, UV Lamp, LED lighting Inner Size: 24 x 24 x 24”
Sampling / Dispensing Booth: GI powder coated with SS workarea & worktable complete with Blower, HEPA filters, UV Lamp, prefilters, Lighting, onsite Calibration to meet NABL & Drug Control requirements Inner Size: 3' x 2½' x 6½ ft
Garment Storage Cabinet: GI powder coated to store upto 10 sets of Clean Room garments with HEPA filtration, UV lamp, LED lamp, hanger rod and a 2 tier shoe rack at the bottom, aluminium framed glass door Inner Size (w x d x h): 3 x 1½ x 6 ft (Optional)
Bidder Name
Mark Air-Particulate control systems
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .