| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC NAGLA UDHA NEAR PRIMARY SCHOOL POST DHANOLI AGRA UP AGRA 282010 | AGRA | AGRA | UP | 282010 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹24.5 L+₹2.3 L (10.2%)Rejected-Finance | L2 | Rejected-Finance Being higher bidder | |
| 3 | Rejected-Technical 115 160 3 ASHIRWAD APARTMENT GEORGE TOWN DARBHANGA COLONY ALLAHABAD UTTAR PRADESH 211002 | PRAYAGRAJ | UTTAR PRADESH | 211002 | - | Rejected-Technical Document Not Fund ok |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
29 Apr 2023, 6:00 pmClosed
GE AF Tech Area Agra
GE AF Tech Area Agra
Annual Maintanance of fire Alarm Fire Fighting and Fire Hydrant System of New ATC P-567 P-568 P-569 Pod Complex of Tech Area under AGE EM of GE AF Tech Area Agra
2023_MES_587010_1
8200-1501/E8
Open Tender
Civil Works
Item Rate
330 days
GE AF Tech Area Agra
As per NIT
9 documents required · 9 mandatory
₹500
Yes
GE AF Tech Area Agra
₹46,000
Yes
15 Jul 2023
25 Mar 2023
1 May 2023
25 Mar 2023
29 Apr 2023
10 Apr 2023
27 Mar 2023 - 3 Apr 2023
Amount
M&L for comprehensive monthly maintenance of auto fire alarm system installed at Annex 'A', 'B' , & 'C' of 50 SQN in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing the defective parts by replacing of all the equipments of fire detection system. (ii) 100% operational of all the equipment of fire detection system shall be maintained at all time . (iii) The contractor will submit Monthly inspection report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through experienced technician. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Spare parts required for replacement will be measured and paid separately under respective items of this schedule as supply only. Note:- 1. The detail of fire detection & fire fighting system are as under:- (a) Microprocessor based fire alarm detection system 04 Zone fire alarm panel- 03 No. (b) Multi-criteria fire detector with base- 130 Nos. (c) Fire Alarm Hooters-12 Nos (d) Fire alarm response Indicators-40 Nos (e) Fire alarm Manual call Point-12 Nos. 2. Testing of the entire fire detection and alarm system shall be carried out and report shall be submit regardinding functioning of the system complete all as specified and directed by Engr-in-charge.
M&L for comprehensive monthly maintenance of auto fire alarm system installed at Annex 'D', & 'E' of 50 SQN in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing the defective parts by replacing of all the equipments of fire detection system. (ii) 100% operational of all the equipment of fire detection system shall be maintained at all time. (iii) The contractor will submit Monthly inspection report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge (iv) The maintenance shall be carried out through experienced technician. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Spare parts required for replacement will be measured and paid separately under respective items of this schedule as supply only. Note:- 1. The detail of fire detection & fire fighting system are as under:- (a) Microprocessor based fire alarm detection system 04 Zone fire alarm panel - 02 No. (b) Multi-criteria fire detector with base- 105 Nos. (c) Fire Alarm Hooters-08 Nos (d) Fire alarm response Indicators-36 Nos (e) Fire alarm Manual call Point-08 Nos. 2. Testing of the entire fire detection and alarm system shall be carried out and report shall be submit regardinding functioning of the system complete all as specified and directed by Engr-in-charge.
M&L for comprehensive monthly maintenance of auto fire alarm system installed at 251 SU in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing defective parts by repalcing of all the equipments of fire detection system. (ii) 100% operational of all the equipment of fire detection system shall be maintained at all time. (iii) The contractor will submit Monthly inspection report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through experienced technician. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Spare parts required for replacement will be measured and paid separately under respective items of this schedule as supply only. Note:- 1. The detail of fire detection & fire fighting system are as under:- (a) Microprocessor based fire alarm detection system 08 loop fire alarm panel- 01 No. (b) Multi-criteria fire detector with base- 30 Nos. (c) Fire Alarm Hooters-05 Nos (d) Fire alarm response Indicators-04 Nos (e) Fire alarm Manual call Point-05 Nos. 2. Testing of the entire fire detection and alarm system shall be carried out and report shall be submit regardinding functioning of the system complete all as specified and directed by Engr-in-charge.
M&L for comprehensive monthly maintenance of auto fire alarm system installed at New ATC in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing the defective pats by replacement of all the equipments of fire detection system. (ii) 100% operational of all the equipment of fire detection system shall be maintained at all time. (iii) The contractor will submit Monthly inspection report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through experienced technician. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Spare parts required for replacement will be measured and paid separately under respective items of this schedule as supply only. Note:- 1. The detail of fire detection & fire fighting system are as under:- (a) Microprocessor based fire alarm detection system 16 loop fire alarm panel- 01 No (b) Multi-criteria fire detector with base- 116 Nos. (c) Fire Alarm Hooters-07 Nos (d) Fire alarm response Indicators-79 Nos (e) Fire alarm Manual call Point-07 Nos. 2. Testing of the entire fire detection and alarm system shall be carried out and report shall be submit regardinding functioning of the system complete all as specified and directed by Engr-in-charge.
M&L for comprehensive monthly maintenance of auto fire alarm system installed at POD section in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing the defective parts by repalcement of all the equipments of fire detection system. (ii) 100% operational of all the equipment of fire detection system shall be maintained at all time. (iii) The contractor will submit Monthly inspection report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge (iv) The maintenance shall be carried out through experienced technician. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Spare parts required for replacement will be measured and paid separately under respective items of this schedule as supply only. Note:- 1. The detail of fire detection & fire fighting system are as under:- (a) Microprocessor based fire alarm detection system 4 zone fire alarm panel- 01 No (b) Multi-criteria fire detector with base- 30 Nos. (c) Fire Alarm Hooters-03 Nos (d) Fire alarm response Indicators-30 Nos (e) Fire alarm Manual call Point-01 Nos. 2. Testing of the entire fire detection and alarm system shall be carried out and report shall be submit regardinding functioning of the system complete all as specified and directed by Engr-in-charge.
M&L for comprehensive monthly maintenance of auto fire alarm system installed at SRE Bldg in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing the defective parts by replacement of all the equipments of fire detection system. (ii) 100% operational of all the equipment of fire detection system shall be maintained at all time. (iii) The contractor will submit Monthly inspection report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge (iv) The maintenance shall be carried out through experienced technician. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Spare parts required for replacement will be measured and paid separately under respective items of this schedule as sypply only. Note:- 1. The detail of fire detection & fire fighting system are as under:- (a) Microprocessor based fire alarm detection system 04 Zone fire alarm panel - 02 No. (b) Multi-criteria fire detector with base- 130 Nos. (c) Fire Alarm Hooters-12 Nos (d) Fire alarm response Indicators-40 Nos (e) Fire alarm Manual call Point-12 Nos. 2. Testing of the entire fire detection and alarm system shall be carried out and report shall be submit regardinding functioning of the system complete all as specified and directed by Engr-in-charge.
M&L for comprehensive monthly maintenance of auto fire alarm system installed at GCA Building in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing the defective parts by replcement of all the equipments of fire detection system. (ii) 100% operational of all the equipment of fire detection system shall be maintained at all time . (iii) The contractor will submit Monthly inspection report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through experienced technician. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Spare parts required for replacement will be measured and paid separately under respective items of this schedule as supply only . Note:- 1. The detail of fire detection & fire fighting system are as under:- (a) Microprocessor based fire alarm detection system 08 loop fire alarm panel- 01 No. (b) Multi-criteria fire detector with base- 36 Nos. (c) Fire Alarm Hooters-04 Nos (d) Fire alarm response Indicators-04 Nos (e) Fire alarm Manual call Point-04 Nos. 2. Testing of the entire fire detection and alarm system shall be carried out and report shall be submit regardinding functioning of the system complete all as specified and directed by Engr-in-charge.
M&L for comprehensive monthly maintenance of auto fire alarm system installed at Hangar No-04, POL Store, Adwitya -1 ,Adwitya -2,Adwitya -3 of 50 Sqn in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing the defective parts by replcement of all the equipments of fire detection system. (ii) 100% operational of all the equipment of fire detection system shall be maintained at all time. (iii) The contractor will submit Monthly inspection report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge (iv) The maintenance shall be carried out through experienced technician. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Spare parts required for replacement will be measured and paid separately under respective items of this schedule as supply only. Note:- 1. The detail of fire detection & fire fighting system are as under:- (a) Microprocessor based fire alarm detection system 16 loop fire alarm panel- 05 No (b) Beam fire detector - 04 Nos. (c) Fire Alarm Hooters -16 Nos (d) Flame fire detector - 04 Nos (e) Fire alarm Manual call Point-22 Nos. (f) Multi-criteria fire detector with base- 12 Nos. (g) Fire alarm response indicators - 04 Nos 2. Testing of the entire fire detection and alarm system shall be carried out and report shall be submit regardinding functioning of the system complete all as specified and directed by Engr-in-charge.
Supply only lead acid battery of 12 Volt, 7 AH complete all as specified and directed. Make: EXIDE (Chloride) / Luminous / AMRON /AMCO
Supply only low intensity hooter/siren electronic type horizontal two stage continuos normal operation for atleast 50 minutes with sound level 65db to 120 db measured at 1.5m with sound aut put variation of +5db , 500m range. for warning of fire, connected with central contol panel installed in each zone inside the rooms complete all as specified and directed. Make:Agani / NSD / Agani Alarm / System sensor
Supply only optical type smoke detector supply voltage 9 to 33 V DC ,UL/FM/LPC approved with junction box and base with self built intelligence as per ISI 11360 to be fixed inside test rig with suitable fixing arrangement complete all as specified and directed. Make:-Apollo/system senser/Siemens
Supply only remote response indicator complete all as specified and directed. Make : MOORLEY/APOLLO/Siemens /Honeywell
Supply only PVC insulated sheathed FRLS type, armoured copper conductor cable of size 1.5 Sqmm 2 core complete all as specified and directed.
Supply only 4 zone microprocessor based fully analog addressable type fire alarm repeater panel complying with BS EN 54 single loop of capacity from 99 detectors & 99 modules upto 200 detector and module complete all as specified and directed. Make: Honeywell/APOLLO/Siemens/Moorley Note :- Panel should be match with existing system
Supply only fire alarm main control panel microprocessor based addressable for 2 wire communication with 99 detectors and 99 modules and addressable response indicators together with mimic diagram made on Auto CAD and pastedon Acrylic sheet with datalogging facility and 2 x16 character LCD, confirming to IS : 2189 complete with PA based evacation system and having its own mains/standby power supply with batteries etc. The panel shall also have an Auto dialling facility and potential free NO & NC contacts and a 80 watts PA amplifier. The Panel shall have a capacity of 12 loops/Zones complete all as specified and directed. Honeywell/APOLLO/Siemens/Moorley Note :- Panel should be match with existing system
Supply only external Siren electronic type horizontal two stage continuoses normal operation for at least 50 minutes with sound level 65 db to 120 db measured at 1.5 m with sound output variation (+) 5 db 2 km range. with control panel complete all as specified and directed. Make: Kheraj / KPT / National / System senser
M&L for repairing, servicing and overhauling of Diesel Engine Driven Fire Pump suitable for automatic operation of capacity 55HP, 1500 RPM including checking of condition and making serviceable of engine compression, exhaust system, tappet mechanism, lubricating system, cooling system including, replacement of oil filter, fuel filter, air filter and any other associated filter and protecting accessories all sorts of oil leakeage by renewal of necessary gasket, replacement of engine oil, chekcing and making alignment of engine with pump ,cleaning of fuel tank and fuel line etc including disconnecting and refixing of Suction and delivery pipe, and transporting to work shop including loading/unloading for necessary repairs such as remetaling, turning of Pump shaft, bearing case of suction & delivery and replacement of impeller, stage bush, alongwith renewal of unserviceable minor parts, with new spare parts, carrying back from workshop, re-installation of the Pump set all as specified all as specified and directed. Make : Kirloskar.
M&L for repairing, servicing and overhauling of electric induction motor driven Fire Pump suitable for automatic operation of capacity 60HP, 1500 RPM 3 Phase 415 Volt, 15 HHZ discharge appx 1620 LPM at 70 Mtr head multi-stage including disconnecting and refixing of Suction and delivery pipe, and transporting to work shop including loading/unloading for necessary repairs such as remetaling, turning of Pump shaft, bearing case of suction & delivery and replacement of impeller, stage bush, alongwith replacement of unserviceable minor parts, with new spare parts, carrying back from workshop, re-installation of the Pump set complete with existing motor alongwith proper coupling and alignment, complete all as specified and directed. MAKE : Kirloskar
M&L for repairing, servicing and overhauling of Jockey pump 15 HP, centrifugal Pump and Squrrel Cage induction Motor 15 HP, 2900 RPM 3 Phase 415 Volt, 15 HHZ discharge appx 180 LPM at 70 Mtr head, multi-stage including disconnecting and refixing of Suction and delivery pipe, and transporting to work shop including loading/unloading for necessary repairs such as remetaling, turning of Pump shaft, bearing case of suction & delivery and replacement of impeller, stage bush, alongwith replacement of unserviceable minor parts, with new spare parts, carrying back from workshop, re-installation of the Pump set with existing motor alongwith proper coupling and alignment, complete all as specified and directed. MAKE : Kirloskar. .
M&L for comprehensive monthly maintenance of fire fighting and fire hydrant system installed at 50 Squadron in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:- (i) Cleaning, inspecting, checking and trial run of all the equipments of fire fighting system. (ii) 100% operational of all the equipment of fire fighting system shall be maintained at all time. (iii) The contractor will submit Monthly inspection report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through experienced technician. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Spare parts required for replacement will be measured and paid separately under respective items of this schedule as supply only.
Note:- 1. The detail of fire fire fighting and fire hydrant system are as under:- (a) Electriclal motor driven fire pump of capacity 55 HP- 01 No (b) Diesel engine driven fire pump of capacity 55 HP - 01 Nos. (c) Electrical motor driven jockey pump - 01 Nos (d) Electriclal control panel for fire fighting system - 01 Nos (e) MS Pipes 150mm dia-3200 RM (f) 63mm dia gumetal landing valve-44 Nos (g) CI sluice valve 150mm dia 15 Nos (h) Non return valve (NRV) 150mm dia- 15 Nos (j) Butterfly valve 80mm dia 33 Nos. (k) Periodical checking and servicing of 63mm dia fire hose pipe 88 Nos at every month , opening and applying the chalk powder and ensuring the no leakage at hose and keeping safely in hose container 2. Testing and trial run of the entire fire fighting and fire hydrant system and servicing the all pump sets and all rotor parts of pumps by applying the lubricants as per OEM recommandations and all equipment servicing report shall be carried out and report shall be submited regardinding functioning of the system to the Engr-in-Charge complete all as specified and directed by Engr-in-charge.
M&L for comprehensive monthly maintenance of fire fighting and fire hydrant system installed at ATC Building in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:- (i) Cleaning, inspecting, checking and trial run of all the equipments of fire fighting system. (ii) 100% operational of all the equipment of fire fighting system shall be maintained at all time. (iii) The contractor will submit Monthly inspection report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through experienced technician. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Spare parts required for replacement will be measured and paid separately under respective items of this schedule as supply only. Note:- 1. The detail of fire fire fighting and fire hydrant system are as under:- (a) Electriclal motor driven fire pump of 55 HP capacity 01 No (b) Diesel engine driven fire pump of capacity 55 HP - 01 Nos. (c) Electrical motor driven jockey pump - 01 Nos
(d) Electriclal control panel for fire fighting system - 01 Nos (e) MS Pipes 150mm dia-3200 RM (f) 63mm dia gunmetal landing valve-44 Nos (g) CI sluice valve 150mm dia 15 Nos (h) Non return valve 150mm dia- 15 Nos (j) Butterfly valve 80mm - 33 Nos. (k) Periodical checking and servicing of 63mm dia fire hose pipe 88 Nos at every month , opening and applying the chalk powder and ensuring the no leakage at hose and keeping safely in hose container 2. Testing and trial run of the entire fire fighting and fire hydrant system and servicing the all pump sets and all rotor parts of pumps by applying the lubricants as per OEM recommandations and all equipments servicing report shall be carried out and report shall be submited regardinding functioning of the system to the Engr in Chagra complete all as specified and directed by Engr-in-charge.
Taking up or down old MS pipe with all fitting from trenches in any length from site a complete all as specified and directed for the following sizes :-
(a) 150 mm dia
(b) 100 mm dia
Supply, laying, jointing, testing and commissioning of ISI marked MS ERW pips following dia heavy duly welded the joints with and including specials etc like bends, tees, reducers, flanges etc. including all supports and coating with anticorrosive paints etc., providing tapping for pressure guage and other instruments, making holes/chasing in wall/ RCC slab if required, including making good the same as original complete all as specified and directed for the following sizes:-.
(a) 150 mm dia
(b) 100 mm dia
Supply & installation, testing and commissioning in renewal ISI marked single headed 63mm dia gunmetal landing Valve, flanged inlet with 63mm dia female intantaneous outlet confirming to IS 5290 on the fire wet riser/down comer including making 80NB pipe connection with riser fixing the landing valves including MS nuts, bolts, gaskets, caps, chains etc. testing the hydrant and completing the work in all respect complete all as specified and directed. Make : Firex/Safex/Minimax/Newage/Kartar/GETECH
Supply and fix in replacement of ISI marked cast iron double flanged sluice valve of 150mm dia rising type stainless steel spindle as per IS : 13095, PN 1.6 class including MS nuts, bolts, gaskets, flanges & washers etc and testing complete all as specified and directed.Make : Kirloskar/Kartar/Venus/IVC/Zaloto/Kalpana.
Supply and fix in replacement ISI marked cast iron double flanged Non Return valve 150mm dia as per IS : 5312, part I including MS nuts, bolts gaskets, and washers etc. complete all as specified and directed. Make : Kirloskar/Kartar/Venus/IVC/Zaloto/Kalpana
Supply and fix in replacement ISI marked cast iron double flanged Non Return valve 100mm dia as per IS : 5312, part I including MS nuts, bolts gaskets, and washers etc. complete all as specified and directed. Make : Kirloskar/Kartar/Venus/IVC/Zaloto/Kalpana
Supply and fix in replacement ,testing & commissioning of 100mm dia Butterfly valve ISI marked including MS nuts, bolts gaskets, and washers etc. complete all as specified and directed. Make : Kirloskar/Kartar/Venus/IVC/Zaloto/Kalpana
Supply and fix in replacement, testing & commisioning of 20mm bore and 30 meter long hose (Rubber lined Dunlop pipe) and hose reel drum for first aid fire fighting conforming to IS :5132, with full swing drum, fixing brackets, 5mm dia shut off gun metal nozzle, 32mm dia, hand lever operated ball valve, connecting directly from the riser through 32mm dia GI pipe with GI sockets, elbows, nipple etc. including providing, operating instructions on a metal plate and fixing it near hose reel drum. The system shall be complete in all respects complete all as specified and directed. Make : Dunlop/Goodyear
S&F in renewal gun metal ISI marked 63mm dia instataneous pattern short branch pipes with 16 mm dia Nozzle suitable for interconnections to hose pipe coupling complete all as specified and directed. Make : Manimax/Firex/Safex/Newage/GETECH
S&F in renewal ISI marked RRL (IS : 636 type II) fire hose pipe 15meter long and 63mm dia with ISI marked (IS : 903) gun metal male and female coupling complete all as specified and directed. Make : Jayshree/Newage or equivalent
Supply and fix Gun metal fire brigade inlet connection for connecting to external fire hydrant ring main consisting of 4 way 63mm dia instantaneous type male coupling with built in check valves 150mm dia, flanged outlet complete with all accessories complete all as specified and directed
Supply & fix in renewal Pressure Switch universal type complete all as specified and directed.
Supply & fixing in renewal dial type Pressure gauge with isolation cock at hydrant station of 150 mm dia and calibration 0-10 Kg/Sqcm complete all as specified and directed.
Supply and fix in renewal weather proof standard fire hose cabinet of size 900mm x 900mm x 600mm outdoor type, suitable for accommodating single headed hydrant valve made of not less than 16 SWG MS sheet having central opening glassed door of size 1M X 0.3M (4mm thick clear glass) including necessary locking arrangement with two numbers MS handle of size 150mm for housing, 15 meter long fire hose pipes, branch pipe and hydrant valve as required including painting (Two coats of the fire red colour over one coat primer). The cabinet shall be mounted on brick masonry platform constructed in (brick work by using sub class 'B' bricks in CM 1:4 of size 1.2M X 1M and 0.3M height, including two coats of white wash over 10 mm thick rendering in CM 1:4) and supported with MS frame made of Angle iron (75X75X6 mm size) as dircted. The words "FIRE HOUSE" to be painted on the box with one coat of synthetic emamel paint of red colour complete all as specified and directed.
Supply and fix in renewal explosive proof addressable type Manual Call Point, break glass type compatible with main fire alarm control board, microprocessor based as per IS-2189 and including chain, hammer facility and blinking facility complete all as specified and directed. Make : Safeway/Degicon/naveen/Suraksha.
Supply and fix in repair 24 Volt DC Hooter cum speaker complete in 16 SWG MS enclousre complete all as specified and directed.
Supply and fix in replacement brass body, open head type automatic sprinkler water deluge type arrangement) heads setwith detector, including fixing arrangement to operate at specified temperature, of following types:- (i)Type- pendent type, (ii) Size: 15 mm dia, (iii) Finish: Brass, (iv) Operating temp- 57° C complete all as specified and directed. Make : Cimtronics (France), Sharp Eye, Megitt USA.
Supply and fix in renewal of 15 mm dia surface captive rosette operating temp 57° C
Supply and install in renewal testing and commissioning of optical beam smoke cum heat multi sensor detector conforming to BS : 5839 Part 5 with base with self built intelligence as per IS 11360, consisting of a transmitter/receiver or reflector, complete all as specified and directed. Make System Sensor or equivalent.
Supply & Fix in renewal of Battery-12 Volts, 120 Ah complete with initial charging, complete all as specified and directed. Make:- EXIDE/ AMARON/AMCO/CUMMINS/KIRLOSKAR
Supply & Fix in renewal rotational moulded polythene water storage tank(triple layer) of capacity 10,000 ltrs(cylindrical vertical with closed top) including hoisting all as specified and directed.
Supply & Fix in renewal starter with automatic switch on/off sensor for 2 HP,230 Volts operated motor pump all as specified and directed.
Supply & Fix in renewal Tubes, 'Medium grade' of size 40mm galvanised in any length, with all fitting and fixed complete to walls and ceilings or laid in floors of complete all as specified and directed
supply and fix in replacement digital wireless water level indicator unit with two digit -07 sigment (50 mm height) display unit to indicate water level of tank in percentage such as full level, 80,60,40,20,low level. It will also indicate flow status including audio/visual alarm for full/low/overflow condition including digital water level data transmeter with battery/solar power water level data sensor to measure water level of tank . Make :- EecobrimAqualife/ Ecoguard
Supply and fix in renewal wiring with PVC insulated armoured stranded copper conductor cable of size 1.5 sqmm x 3 core, 230 Volt grade, fixed on wall/surface with MS saddles complete all as specified and directed.
GUJRAL BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .