Loading…
Loading…
Tender Value
₹1.1 Cr
EMD Value
₹2.1 L
Closing Date
20 Mar 2026, 3:30 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TELECOM
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. Client certificate from other than Govt Organization should be duly supported by Form 16A/26AS generated through TRACES of Income Tax Department of India.
The tenderer must have successfully completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- 1. Work of Supply, Installation, Testing and Commissioning of PDH/SDH, ADM/PD Mux and its associated equipments. OR 2. AMC of PDH/SDH, ADMs, PD Mux/Faulty Card of Mux Repair work and associated equipment. OR 3. Work of Excavation of Trench and Underground cable laying, Jointing of copper cable or OFC cable. OR 4. Trenching, Laying, Splicing and Testing of OFC Cables and Part Supply, Testing and Commissioning of SDH equipment. OR 5. Trenching, Laying, Jointing and Testing of 6 Quad/PIJF Cables including, Erection & testing of Emergency socket and part Supply, testing and commissioning of Repeater Equipments. OR 6. Trenching, Laying, Splicing/Jointing and Testing of OFC/6 Quad Cables, Erection & testing of Emergency socket and part Supply, Testing and Commissioning of SDH/Repeater E q u i p m e n t . NOTE A1: For the following equipment's a.SDH/STM/PDMUX/IPMPLS/VOIP b. Control equipment c. ISDN/IP based exchange d. CCTV/Video surveillance system e. Integrated security system f. Networking equipment g. Train information display board/Coach guidance system/IPIS/GPS CLOCKS h. secured communication system at level crossing gates i. VSAT J. MTRC 1. The equipment shall be procured from: a) If there is any RDSO approved source, then the equipment to be procured from the RDSO approved source or its authorized dealer/distributor b) If there is no RDSO approved source but there is TEC approved source, then the equipment to be procured from the TEC approved source or its authorized dealer/ distributor c) If there is no RDSO or TEC approved source then the equipment to be procured from the OEM or its authorized dealer/ distributor. 2. Make, Model Specification of the offered equipment along with OEM authorization if the tenderer is other than OEM shall be submitted along with the tender. 3. MOU with RDSO approved Source or TEC approved source or the OEM, covering Supply, installation, testing, commissioning of system including after sales support required during warranty period shall be submitted along with the tender.
26 conditions · 15 needing a document upload
Firm has to submit authorization letter for uploading documents on IREPS in case he/she is not an authorized person.
PAN card Copy should be enclosed.
Please submit the copy of the registration certificate as applicable, GSTIN certificate should be enclosed.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderer should go through Annexure 1 & 2 of Tender Notice (attached in Tender Document)for list of documents required to be uploaded along with the offer.
Contractors are allowed to make payments against this tender towards tender document cost and earnest money only through only payment modes available ON IREPS portal LIKE net banking, debit card, credit card etc.Manual payments through Demand draft, Banker cheque, Deposit receipts, FDR etc. are not allowed.
Copy of PAN number and GSTIN number should be submitted.
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenders shall be treated as NULL & Void.
(i)Tenderers will examine various provisions of the Central Goods and Service Tax Act, 2017(CGST)/Integrated Goods and Service Tax Act,2017(IGST)/Union Territory Goods and Service Tax Act,2017(UTGST)/respective states State Goods and Service Tax Act(SGST) also, as notified by Central/States Govt. and as amended from time to time and applicable taxes before bidding. Tenderers will ensure that full benefit of Input Tax Credit(ITC) likely to be availed by them is duly considered while quoting rates. (ii) The successful tenderer who is liable to be registered under CGST/IGST/UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/UTGST/SGST Act to railway immediately after the award of contract, without which no payment shall be released to the contractor. The contractor shall be responsible for deposition of applicable GST to the concerned authority. (iii) In case the successful tenderer is not liable to be registered under CGST/IGST/UTGST/SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism(RCM) and deposit the same to the concerned authority.
Provision of OFC connectivity for SCADA control of new 2x25 KV Switching posts (TSS/SP/SSP) in Kanpur-Lucknow section being erected in connection with raising of speed of section to 160 Kmph, Northern Railway
106-Tele_Tender_28_25-26
106-Tele_Tender_28_25-26
Open
Works - General
240 Days
Lucknow, Uttar Pradesh
₹0
₹2.1 L
20 Mar 2026
27 Feb 2026
6 Mar 2026
87 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,14,25,581.5 | ||
| — | 5440.00 | — | — | ||
| Laying of signaling /telecom / power cable of different cores as per Drg No (NR /S&T / Con /1.1/97C) and as per cable route plan approved by Railway through trenches, RCC pipe, DWC pipe, GI pipe etc. Meggering of cable should be done before and after laying. Cable will be made available at the store of concerned SSE/Tele or any other store N. Railway. Contractor has to transport it to work site at his own expenses. | — | — | — | 35,033.6 | |
| — | 5440.00 | — | — | ||
| Excavating and refilling of trench in Normal Soil to the level of ground with rammed earth as per drg. No. NR/S&T/Con./1.1/97A or latest so as not to form a drain 0.3 mtrs. Wide & 1 mtr. Deep on both side of the station alongside the track. It shall conform to the safe distance as per signalling and cable plan in all type of soil. It also includes clearance of roots of trees & bushes. (15cm wide 30cm depth) | — | — | — | 2,85,273.6 | |
| — | 21760.00 | — | — | ||
| "Supply and Laying of 2nd Class bricks in the trench and laying as per DRG no. (NR/S&T/Con./1.1/97A) and as per instruction of the site Engineer INSPECTION: CONSIGNEE FOR SUPPLY PORTION" | — | — | — | 1,50,796.8 | |
| — | 43.00 | — | — | ||
| "Supply of Thermo shrink Jointing kit (spec no. IRS:TC-77-2012 Rev. 1) with amendment no 2 for Quad/derivation cable straight through and derivation joint for LC gate etc where VF transformer not required. INSPECTION: RDSO" | — | — | — | 1,05,528.02 | |
| — | 43.00 | — | — | ||
| Jointing/Installation of Thermoshrink Jointing kit (spec no.IRS:TC -77-2012 Rev. 1)with amendment no 2 for Quad /derivation cable straight through and derivation joint for LC gate etc . Execution ofwork as per site engineer | — | — | — | 56,286.14 | |
| — | 11.00 | — | — | ||
| "Supply of apparatus case steel halfwith 'E' type locks and key ward No.42 as per drawing No. RDSO/S-11507 or latest. Handle should be atthe rate of one each per 4 Nosapparatus case. INSPECTION: CONSIGNEE" | — | — | — | 1,87,880.33 | |
| — | 11.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of app. Case half as per Drg, No (NR/S&T/Con/2.8/97). A layer of 3mm of Bitumin compound has to be provided between foundation and location box to prevent ingress of water in the base of location box. All material such as cement, sand, aggregate & anchor bolts shall be supplied by the contractor. Contractor is required to execute all type of repair work of foundation if required during inserting the cable for termination. | — | — | — | 57,531.65 | |
| — | 136.00 | — | — | ||
| Fabrication, supply and fixing of concrete cable marker as per RDSO drg. No. SDO/Cable Laying/020, dt.31.10.11. The marker shall be fixed at various places of cable route as per instruction of Eng. at site. | — | — | — | 1,71,372.24 | |
| — | 6.00 | — | — | ||
| "Supply of Emergency socket box made of FRP material as per Spec. No. RDSO/SPN/TC/44/2002 INSPECTION: CONSIGNEE" | — | — | — | 28,002.9 | |
| — | 6.00 | — | — | ||
| "Supply of 6 pin Emergency socket SPECIFICATION NO: IRS:TC:42/87 with latest amendment INSPECTION: CONSIGNEE" | — | — | — | 1,642.32 | |
| — | 6.00 | — | — | ||
| Fixing of Emergency socket box made of FRP material as per Spec. No. RDSO/SPN/TC/44/2002 Ver.2 (With latest amendment) at locations to be indicated by the engineer . Emergency Socket & Emergency socket box will be procured through separate schedule of this contract and issued to the contractor for execution). All other items shall be supplied/arranged by the contractor. | — | — | — | 5,245.8 | |
| — | 6.00 | — | — | ||
| "Supply of thermo shrink jointing kit as per IRS TC 77/2012 Rev.3 with Amdt 1 & 2 latest amendments & provision of derivation isolation joint in quad cable & PIJF cable at LC gate, pump, houses, station cabins etc using thermo shrink jointing kit as per specifications, drawings and stipulations of tender documents. This includes all material required for making joints. INSPECTION: RDSO FOR SUPPLY PORTION" | — | — | — | 57,340.8 | |
| — | 50.00 | — | — | ||
| Supply of VF Transformers (2T/3T), 1120/470Ohms as per RDSO Spec. No. IRS: TC-76- 2000with Amnd. 1 or latest for emergency joints in 6-Quad Cable. INSPECTION:CONSIGNEE | — | — | — | 45,801 | |
| — | 500.00 | — | — | ||
| "Supply of 20 Pair PIJF cable 0.63MM armoured cable Make: Usha Martin or Similar. INSPECTION: CONSIGNEE" | — | — | — | 83,405 | |
| — | 20.00 | — | — | ||
| "Supply and installation of20 Pair CT Box with 24 nos.WAGO terminals andtermination of cable as perIRS/TC/18/75 with latestamendment. Execution ofwork as per site engineer Asper technical specificationattached as Annexure - A"" INSPECTION: CONSIGNEE FOR SUPPLY PORTION" | — | — | — | 25,000 | |
| — | 5440.00 | — | — | ||
| Pulling and Blowing/drawing of OFC cables inthe HDPE duct along with all theprotective work as per instructionsof engineer incharge at site. | — | — | — | 68,272 | |
| — | 5440.00 | — | — | ||
| "Supply of Pre-lubricated HDPE duct, 40 mm OD, 33 ID as per RDSO specification No. RDSO/SPN/TC/45/2013 Rev. 2.0 or latest. The item also includes supply of all the accessories of HDPE duct like end caps, collars, bends, couplers etc. INSPECTION: CONSIGNEE" | — | — | — | 3,23,027.2 | |
| — | 5440.00 | — | — | ||
| Laying of PLB HDPE pipe in trench/open space, fixing and clamping of HDPE pipe on wall or structure and sealing of the duct after laying with proper fixing material. All the accessories like couplers, end caps/plugs to be provided by the contractor within the same cost and its protective work as per direction of site engineer. | — | — | — | 54,508.8 | |
| — | 1100.00 | — | — | ||
| Horizontal direction drilling(HDD)/Trenchlessdigging/machine drilling withoutdamage to surface road /trackfor laying/insertion ofHDPE/GI/DWC pipe. The boreshall be done at the depth ofminimum 1400 mm from theground level. The ground levelshall be considered ignoring thebank height of the bank of the road. Note:- DWC/HDPE/GI PipeSupply is not covered under thisitem. Contactor shall provide allmaterial required for work andadequate nos. of labours forproper laying of cables into thebore. Cable shall be laidcautiously so that it should notget damage due to roughhandling & pressure on cable.Payment of boring shall bemade only aft er DWC/HDPE/GIpipe is laid in the bore." | — | — | — | 5,39,891 | |
| — | 20.00 | — | — | ||
| "Supply, Installation and commissioning of Fibre Distribution Management system (FDMS)/LIU for 24 Fiber complete with all accessories with patch cord & pigtail as per TEC Spec. GR/FDM/01/02April'2007 or latest. This include supply of installation accessories as per technical specification. INSPECTION: CONSIGNEE FOR SUPPLY PORTION" | — | — | — | 1,28,410 | |
| — | 10.00 | — | — | ||
| "Supply of 12 port loaded LIU rack mountable, LIU shouldbe provided for terminating the optical fiber cables. It shall provide minimum bending radius and splice trays shall function as a splice cover for Pigtail Splicing. Cable glands shall be provided for secure anchoring of incoming cables. Rubber grommets shall be provided at the cable entry point for tight sealing. The splice tray should be made of ABS materials. LIU should be of reputed make. Make: D-Link/3M/ Digilink/Molex/ DAX or similar. INSPECTION: CONSIGNEE" | — | — | — | 37,000.8 | |
| — | 10.00 | — | — | ||
| Installation, Testing & Commissioning of rack mountable 12 port Loaded LIU. All the accessories and fixing materials required for this installation are to be supplied by contractor within the same cost. | — | — | — | 6,834.1 | |
| — | 1080.00 | — | — | ||
| Splicing/Dropping /Termination of each fibre/pigtail in the LIU/I0 Box/Terminal Joints through fusion splicing of termination of OFC cables. The fibres terminated shall be tested and the test report (Hard copy and soft copy) shall be submitted to the site Engineer for records . Each fibre shall be properly marked with necessary ferrules/tags. | — | — | — | 1,37,160 | |
| — | 10.00 | — | — | ||
| "Supply and installation of 9U, 19 inch rack for pole mount/ wall mount with Fan 230VAC 90CFM-02 Nos., AC distribution box (5 socket of 5A, Power On LED indicator, MCB)- 01 No., Shelf Cantilever 1U: 01 No. Cable Manager 1U:01 No. INSPECTION: CONSIGNEE FOR SUPPLY PORTION" | — | — | — | 1,20,943.1 | |
| — | 5.00 | — | — | ||
| "Supply & Installation of 19"" Rack 17U withpower strip and all fitting accesssories forhousing of network equipment. Both side door INSPECTION: CONSIGNEE FOR SUPPLY PORTION" | — | — | — | 96,156.1 | |
| — | 500.00 | — | — | ||
| "Supply of 3 Core x 2.5 Sq mm multi strand copper conductor, PVC insulated, armoured power cable confirming to IS:1554 partI as per RDSO specification No. RDSO/SPN/TC/65/2021 rev 6.0 or latest). Finolex/polycab/orbit/ havell or any other reputed make. INSPECTION: CONSIGNEE " | — | — | — | 54,865 | |
| — | 5.00 | — | — | ||
| "Supply, Installation & commissioning of Maintenance free earth using basic earthing kit as per RDSO specification RDSO/SPN/197/2008 or latest and Drg No. SDO/RDSO/E&B /001 & 002 dated 19.9.2008 or latest. Earthing kit consist of 1. Earthing electrode of 17mm dia and 3 meter long-01 no. 2. MEEB (300mm X 25mm X 6MM) -01 no. 3. SEEB (150mm X 25mm X 6 mm) - 01 no. 4. Earth enhancing compound - 30 Kg (minimum). This include provision of earth connection from MEEB to S&T equipment i.e. cable sheath, apparatus case, IPS, data logger, signal etc. with PVC earth wire of size 16/25 Sq.mm through copper lugs of suitable size. PVC wire shall be supplied by Railways. Note: At certain locations it may not be possible to achieve earth resistance of less than 1.0 ohm with one earth electrode/pit due to soil resistivity. In such case provision of loop earth consisting of more than one earth pit shall be done. For interconnection of two earth pits copper tape of size 25X2 sq. mm shall be provided by contractor. The number of pits required shall be decided based upon the resistance achieved for the earth pit already installed. The procedure mentioned above for one earth pit shall be repeated for other earth pits. The other earth so installed for the purpose of loop earthing arrangement shall be counted as separate earth. Material to be procured through RDSO approved firm. Contractor have to submit check list duly signed by OEM after installation. INSPECTION: RDSO FOR SUPPLY PORTION" | — | — | — | 1,19,713.85 | |
| — | 115.00 | — | — | ||
| "Supply of OFC patch cord cable (10m long with APC/FC/LC-LC/FC/APC connector Patchcord). INSPECTION: CONSIGNEE" | — | — | — | 73,230.85 | |
| — | 100.00 | — | — | ||
| "Supply of LC/PC-LC/PC patch cord (5 meter) (3M, TE connectivity, R&M make or superior) INSPECTION: CONSIGNEE " | — | — | — | 12,420 | |
| — | 100.00 | — | — | ||
| "Supply of Single Mode Patch Cord length 3 meters (LC-SC/SC-SC/LC-LC/FC-LC) as per site requirement. INSPECTION: CONSIGNEE" | — | — | — | 18,692 | |
| — | 250.00 | — | — | ||
| "Supply of STP/UTP RJ 45 Connectors Make D-Link, AMP, DAX, Legrand, Molex or Digilink. INSPECTION: CONSIGNEE" | — | — | — | 2,785 | |
| — | 20.00 | — | — | ||
| Supply and installation of 4 wire DTMF based waystation equipment complete as per RDSOs pecification No. IRS:TC@45<47@2007 and IRS-TC@45&47@97 and 4 wire control telephone with audio visual indication and reset button fitted on telephone conforming to specification No. IRS:TC@45<47@2007 and IRS-TC@45&47a46@ This work also includes supply and wiring of power supply arrangements for way station equipment conforming to specification IRS.TC.72/97. [All the materials required for the work shall be supplied by the Contractor]. INSPECTION: CONSIGNEE FOR SUPPLY PORTION" | — | — | — | 2,25,501.8 | |
| — | 14.00 | — | — | ||
| "Supply of 48V Managed media converter(Ethernet/E1 to Optical) as per RDSO specNo.RDSO/SPN/TC/103, Rev 2.0 or latest andas per details given below for SCADAworking. Its supply includes three tributaryslots & one optical module supportingdistance of 20 Kms with (1+1) protection onoptical interface (one dual core & one singlecore) , 2E1 ports and four 100Mbps ETHinterface through Optical interface and builtin DSL modem to work on quad or copper(2W) up to five kms with auto change overfeature between DSL line (2W) & Opticalinterfaces and three tributary slots loadedwith one four port E&M interface supporting2W/4W configurable for TPC / EC provision ;one tributary slot loaded with ETH module supporting RSTP feature for connecting RTUand one tributary module support four porttwo wire voice for connecting hotline & Autophone ( 2 port each (FXO & FXS ). Unit to bestandard telecom rack mountable andsupplied with rack mounting kit / Unit to haveE1 tributary module supporting two E1 asoption for converting E1 to ETH for RTUpurpose at SSP/SP/TSS locations. Type ofMedia convertor-option 3, Media convertor -without POE, patch card cable-not required,SFP-should support 20KMS distance.. INSPECTION: RITES" | — | — | — | 35,30,502.78 | |
| — | 14.00 | — | — | ||
| "Supply of 110V Managed media converter(Ethernet/E1 to Optical) as per RDSO specNo.RDSO/SPN/TC/103, Rev 2.0 or latest andas per details given below for SCADAworking. Its supply includes three tributaryslots & one optical module supportingdistance of 20 Kms with (1+1) protection onoptical interface (one dual core & one singlecore) , 2E1 ports and four 100Mbps ETHinterface through Optical interface and builtin DSL modem to work on quad or copper(2W) up to five kms with auto change overfeature between DSL line (2W) & Opticalinterfaces and three tributary slots loadedwith one four port E&M interface supporting2W/4W configurable for TPC / EC provision ;one tributary slot loaded with ETH modulesupporting RSTP feature for connecting RTUand one tributary module support four porttwo wire voice for connecting hotline & Autophone ( 2 port each (FXO & FXS ). Unit to bestandard telecom rack mountable andsupplied with rack mounting kit / Unit to haveE1 tributary module supporting two E1 asoption for converting E1 to ETH for RTUpurpose at SSP/SP/TSS locations. Type ofMedia convertor-option 3, Media convertor -without POE, patch card cable-not required,SFP-should support 20KMS distance. INSPECTION: RITES" | — | — | — | 34,04,358.58 | |
| — | 1525.00 | — | — | ||
| "Supply of CAT-6 UTP Cable (23 AWG). It Shall comply to TEC GR No. TEC/GR/SLC - 01/02.AUG 05 (TEC Standard Number: TEC 52010:2005) with latest amendments,Version reputed make Siemen/Systemax/D-Link/Tyco/Krone/AMP or similar INSPECTION: CONSIGNEE " | — | — | — | 39,070.5 | |
| — | 1525.00 | — | — | ||
| Laying of OFC/Power cable/CAT-6 cable PA Cable/Data cable and all the other types of telecom cable and all the other types of telecom cable through HDPE pipe/casing capping/fall ceiling with laying/fixing of HDPE pipe/casing capping/uPVC pipe for connecting/interfacing variouys cpmponents and system integration. All materials for jointing and termnaition of power cable/CAT-6 cable as per site requirement are to be supplied by contractor. This item also includes supply of RJ- 45 connector with cap for terminating CAT-6 cable and supply and installation of power board with 4 points (3 nos 5 amp sockets and 1 nos 15 Amps socket) as per site requirement. | — | — | — | 40,138 | |
| — | 1000.00 | — | — | ||
| "Supply and fixing of G.I. pipe 75mm dia, 3mm thick as per spec no IS-1239, perforated at a distance of 20 CM or less of required length at culverts/ bridges/along the cuttings, suitably concreted at both ends as per approved drg. No.Drg. No.NR/S&T/CON/1-4/97.or at ASM office/other buildings suitably fixing it to the wall and at both ends. G.I. clamps of M.S. flats bolts and nut, to be supplied by the contractor. Inspection by- Consignee for supply portion. this inclues trasnporting GI Pipe from any store of LKO Div, to site INSPECTION: RITES FOR SUPPLY PORTION" | — | — | — | 9,83,900 | |
| — | 20.00 | — | — | ||
| """Supply of DP Box 20Pair with Krone Modules . INSPECTION: CONSIGNEE" | — | — | — | 13,909.6 | |
| — | 20.00 | — | — | ||
| Installation of DP Box 20Pair. The work is toexecuted as per theinstruction of RailwayEngineer. | — | — | — | 695.8 | |
| — | 20.00 | — | — | ||
| "Supply of krone Module10 Pair Make :Krone orSimilar. INSPECTION: CONSIGNEE" | — | — | — | 1,509.8 | |
| — | 20.00 | — | — | ||
| Installation of kroneModule. The work is toexecuted as per theinstruction of RailwayEngineer. | — | — | — | 75.4 | |
| — | 10.00 | — | — | ||
| "Supply of Power Board (3 No's 5 amp & 1 no 15 Amp socket total-4 points). Make: Anchor, Havells or similar. INSPECTION: CONSIGNEE" | — | — | — | 5,468.7 | |
| — | 1.00 | — | — | ||
| "Supply of workstation suitable for fault analysis or other application. Note:- Workstation configuration are as follows: Intel Core i5 10500 or higher, 16 GB RAM, HDD 1000 GB, SSD 512 GB Windows 10/11, 2K display 21.5 Inch or better. It also includes supply of Laser duplex Printer (Make HP/Brother or better). INSPECTION: CONSIGNEE" | — | — | — | 90,400.54 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TD_1.pdf
ATTACHMENT
ACSGCC22-231to6.pdf
ATTACHMENT
GCC Correction slip 7 to 10
ATTACHMENT
GCC_April-2022_1.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipno7-10.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .