Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.8 LAccepted-AOC KRAL PORA BAGH I MEHTAB NEAR MANCHOWA PETROL PUMP DISTRICT BUDGAM 190019 J K | BUDGAM | BUDGAM | J K | 190019 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹29.7 L+₹1.0 L (3.59%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹34.2 L+₹5.5 L (19.1%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹37.4 L+₹8.7 L (30.5%)Rejected-Finance 254 GOVT HOUSING COLONY CHANNAPORA SRINAGAR 190015 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190015 | L4 | Rejected-Finance L4 | |
| 5 | L5₹42.6 L+₹14.0 L (48.7%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
23 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE 134 Wks Engrs
HQ 134 Wks Engrs PIN-914134 c/o 56 APO
REPAIR/MAINT OF HT DISTRIBUTION SYSTEM AND ALLIED WORKS AT KHUNMOH, KHREUH AND SHER-E-SHALI UNDER GE 861 EWS.
2022_MES_540272_1
134 WE-30(T)/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Srinagar
9 documents required · 9 mandatory
₹500
GE 861 EWS
₹90,000
Yes
13 Dec 2022
22 Jul 2022
25 Aug 2022
22 Jul 2022
23 Aug 2022
9 Aug 2022
23 Jul 2022 - 29 Jul 2022
Amount
Excavation in trenches in soft/ loose soil, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables, pipes, erection of pole etc, complete all as specified and directed.
Excavation in trenches not exc 1.5m wide and exc 1.5m but not exc 3m in depth and getting out in soft /loose soil for laying of cables, pipes, erection of pole etc, complete all as specified and directed.
Removing excavated soil to a distance not exc 50 mtr and deposting where directed at a level not exc 1.5m above the starting point, complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick, complete all as specified and directed.
M&L for dry river sand, laid in trenches for cable protection, as 15cm thick below the cable and 8cm thick after laying the cable, and laying in duct of any thickness of sand, complete all as specified and directed. Note :- Punned thickness of sand provided for cable protection shall be measured & paid.
Supplying and Laying reinforced precast concrete cable cover, class HV, type-2, flat, of size 450x180x40mm, complete all as specified and directed.
M&L for PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregates) as in foundation, filling in and mass concrete etc, complete all as specified and directed.
M&L for PCC 1:3:6, type C-2 (using 40mm graded crushed stone aggregates) as in foundation, filling in and mass concrete etc, complete all as specified and directed.
M&L for PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregates) as in stay filling, coping etc, including necessary form work, complete all specified and directed.
M&L for repair/ replacement cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm, complete all as specified and directed.
M&L for repair/ replacement cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm, complete all as specified and directed.
M&L for repair/ replacement cable jointing kit for 11KV/6.6 KV grade cable for indoor termination, heat shrink type joint, complete with jointing material and accessories, suitable for size 3 core XLPE armoured aluminium conductor cable of size 70 to 95 sqmm, complete all as specified and directed.
All as per Ser item No 12.00 here-in-above, but outdoor termination.
All as per Ser item No 12.00 here-in-above, but outdoor termination, suitable for 120 to 185 sqmm size cable.
Supply and laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 11000 volts grade, cross sectional area 120 Sqmm 3 Core and including taking up/ down existing unsv cable, complete all as specified and directed.
All as per Ser item No 15.00 here-in-above, but cross sectional area 95 Sqmm 3 Core.
All as per Ser item No 15.00 here-in-above, but cross sectional area 70 Sqmm 3 Core.
Dismantling and taking out PCC HT pole fixed in any positiion and removal from site and taken in credit, complete all as specified and directed.
Supply installation and erection in vertical position steel tubular swaged poles, type 410, SP-55 (11 meters long) with 300mmx300mmx6mm mild steel base plate continuously welded to pole, MS plate 3mm thick finial taper plug bolt, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally throughout and externally for embedded portion and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surfaces and making alternate black and white strips 30cm high with super enameled paint over a coat of red oxide primer up to 1.5 mtrs height from ground level/coping after erecting, complete all as specified and directed. Note : Excavation, PCC for foundation and earth work shall be measured and paid separately.
Supplying, fixing and testing gang operated air breaker switch, triple pole, mechanically operated mounted on insulators and steel frame with operating mechanism worked from ground level using heavy duty GI pipe for current rating 200 Amps, out door type (confirming to IS specifications) HT 11 KV, tripple pole with fixed contacts of phosphorous and bronze and a set of drop out HT fuse assembly, fuse carrier fitting, 12 insulator type mounted on MS channel operating rod with pad lock arrangement including dismantling old UNSV GOD, complete all as specified and directed.
S&F in repairs mild steel cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive two coat of synthetic enamel paint over one coat of red oxide zinc chrome primer after prepration the surface, complete all as specified and directed.
S&F in repairs anti climbing device, comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.0mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 meter clamped and properly secured or as ordered, complete all as specified and directed. Note : Clamps measured and paid separately under relevant item.
Dismantling of existing old unserviceable ACSR conductor of any size and any description and S&F new ACSR conductor all as specified and directed incl stringing through existing RCC/ steel poles, fixing in insulators, jumpers with polythene pipe, aluminium binding wire etc complete of different sizes, complete all as specified and directed.
S&F in replacement lightning arrestor, expulsion type complete with all fittings, transmission class, discharge capacity of 65 Kilo Amps, suitable for 11 KV, complete all as specified and directed.
S&F in repairs danger notice plate, made out of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT, of size 25x20cm, complete all as specified and directed.
S&F expulsion type drop out fuse with all accessories and contact insulator etc fixed on HT pole rating above 10 and up to 25 Amps, suitable for 11/6.6 KV 3 pole with two Nos insulators per pole including dismantling old unserviceable one, complete all as specified and directed.
S&F Pin type insulator, porcelain, vitreous, white, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 150mm dia and 150mm height, suitable for 11 KV grade including taking down old unserviceable insulators, complete all as specified and directed.
S&F Disc type porcelain insulators 145mm height and 255mm dia ball and socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors working pressure 11 KV grade including taking down old unserviceable insulators, complete all as specified and directed.
S&F loop type porcelain vitreous white, brown or green insulator with over all dimension 90mm x 140mm clearance of hole 25.5mm including taking down old unserviceable insulators, complete all specified and directed.
M&L for replacement stay assembly complete with 20mm dia stay rod with accessories shown in electric plate No 01 incl stay clamps, complete all as specified and directed. Note :- Loop insulator, stay wire, excavation and concrete work shall be measured and paid seperately under respective items of BOQ.
M&L for preparation of old painted surface, cleaning of dust/ oils/ lubricants etc and applying one coat of aluminium paint on HT 4 Pole structure including cross arms, bracing etc, complete all as specified and directed.
All as per Ser item No 31.00 here-in-above, but on HT 2 Pole Structure.
Supply, fixing & testing in replacement numerical type relay for VCB/ OCB tripping system (3 OC + 01 earth fault and high set instantaneous protection in single unit) suitable for operation on 24 V DC all as per per existing, complete all as specified and directed. Note : If any modification in the wiring and panel sheet enclosure is deemed to be included in quoted rates.
Supply, fixing & testing in replacement master relay for VCB tripping system with parelly (3 OC + 01 earth fault and high set instantaneous protection in single unit) suitable for operation on 24 V DC all as per per existing, complete all as specified and directed. Note : If any modification in the wiring and panel sheet enclosure is deemed to be included in quoted rates.
Taking down and reinstall transformer step down 11/6.6KVA 415 Volts complete, outdoor/ indoor type of capacity up to 300 KVA incl transportation to the workshop and back to site, complete all as specified and directed.
M&L for strip opening of transformer and removing the top cover for inspection, draining the transformer oil and taking out the core along with HT/ LT coil (windings) assembling the core after replacement of HT/ LT coils heating varnishing, testing and housing accessories in transformer body and connection up, filling in dehydrated new transformer oil and connection with existing electrical system HT/ LT and commissioning, complete on load of capacity not exceeding 160 KVA, complete all as specified and directed. Note : Transformer oil shall be measured and paid separately under relevant item.
All as per Ser item No 36.00 here-in-above but on load of capacity above 160 KVA and up to 300 KVA.
M&L for filtration of transformer/ OCB/ VCB/ stablizers oil of transformers step down 11/6.6 KV/ 0-433 Volt, indoor/ outdoor type of capacity up to 500 KVA, installed at different sub stations/ locations using filtration and heating equipment at site by re-circulating transformer oil heating, dehydration and improving di-electric strength of the oil to withstand 40 KV for one minute including testing of oil, complete all as specified and directed. Note : Oil test kit shall be provided by the contractor at site for testing of oil without any extra cost.
M&L for filling in with new transformer/ OCB/ VCB/ stablizers oil, low viscosity of approved make as per IS-335 of 1992 and di-electric strength 50 KV when tested at 2mm gap, complete all as specified and directed.
M&L for winding of HT/ LT coil of different type, capacity and make of transformer with approved quality supper enameled copper wire/ strips, of suitable gauge and number of turns along with allied materials such as cork sheet, fiber glass insulations, paper insulations, cotton/ Empire tap and tube wooden blocks bolts, nuts and washer (Brass) soldering and other packing material etc, complete all as specified and directed.
S&F HT bushes porcelain, vitreous with brass spindle, threaded with washer, nuts, lock and rubber seal, suitable for transformer of capacity up to 160 KVA, complete all as specified and directed.
All as per Ser item No 41.00 here-in-above but of capacity 160-300 KVA.
S&F LT bushes porcelain, vitreous with brass spindle, threaded with washer, nuts, lock and rubber seal, suitable for transformer of capacity up to 160 KVA, complete all as specified and directed.
All as per Ser item No 43.00 here-in-above but of capacity 160-300 KVA.
M&L for breather assembly CI body of standard size, filled with silica gel of transformer of capacity up to 300 KVA complete with nuts, bolts and washers, complete all as specified and directed.
Supply, jointing and connecting galvanised steel wire 3.15mm dia with cradles hexagonal/ rectangular, complete all as specified and directed.
M&L in repairs for GI tubing light grade 80mm bore with all fittings, laid in trenches or fixed to walls/ alongwith pole with suitable MS clamps, complete for protection of electric cable, complete all as specified and directed.
M&L for cutting, making hole to road/ path/ hard standing for provision of GI pipe 80mm to 100mm bore for passing cable including making good the disturbed surfaces with matching existing surface, complete all as specified and directed.
Supply and laying coarse aggregates of 20mm graded at different places, around HT pole structure/ feeder panel/ 33KV yard, complete all as specified and directed.
Cutting of tree branches from any height and type of trees in route of HT over head line or near to the HT over head line as per the direction of Engr-in-charge and cleaning of site. Notes : (a) The tree branches shall be 2 Mtr away from the outer conductor of OH lines after cutting. (b) Any damage cause due to contractor's labour will be rectified by the contractor without any extra cost to Govt. (c) T&P such as ladder, rope, cutter, Axes and other required tools shall be provided by the contractor.
Supplying and laying in replacement synthetic Rubber insulated mat 2.5 mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock, of sizes 2m x 1m, complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 600x600x6mm thick, burried directly in ground, earth pit not less than 2.25 Mtr deep below normal ground level with top edge of earth plate not less than 1.5mtr below normal ground level, connected to the Galvanised iron strip of size 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron, protected by GI tube light grade 40mm bore including provision of concrete pit in PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) with 40mm thick RCC 1:2:4 cover, reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia round bar handle, excavation and earth work in any type of soil, charcoal dust and salt and 20mm bore GI watering pipe light grade with funnel and wire mesh including dismantling old UNSV earthing and removal thereof, complete all as specified and directed by Engr-in-Charge. Notes :- (i) Main earthing strip from earth plate electrode to test point up to length of 7.5 meters length shall deem to be included in quoted rates. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department .
M&L for earthing complete with galvanised steel earth plate electrode of size 600x600x6mm thick, burried directly in ground, earth pit not less than 2.25 Mtr deep below normal ground level with top edge of earth plate not less than 1.5mtr below normal ground level, connected to the Galvanised iron wire of 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron, protected by GI tube light grade 15mm bore including provision of concrete pit in PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) with 40mm thick RCC 1:2:4 cover, reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia round bar handle, excavation and earth work in any type of soil, charcoal dust and salt and 20mm bore GI watering pipe light grade with funnel and wire mesh including dismantling old UNSV earthing and removal thereof, complete all as specified and directed by Engr-in-Charge. Notes :- (i) Main earthing strip from earth plate electrode to test point up to length of 7.5 meters length shall deem to be included in quoted rates. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department .
M&L for maint free safe earthing system (set of four electrod to be used as grid for equipment earthing) each pit complete with 01 Number UL 467 approved/ CPRI tested copper bonded (copper cladded earth rod with 250 microns of copper cladding) earth rod with 17.2mm dia 3000mm long electrode buried in ground to bore holes 120 mm dia vertically to a depth not less than 3.50 mtr deep below normal ground level or 'L' shape in case of Rocky condition (2 ft deep and 8 ft horizontol) with top edge of earth electrode at a depth not less than 500mm below normal ground level, provision of copper bus bar of size 200mmx25mmx6mm for inter connection with copper earth lead strip of size 25mm x 3mm and further connected to test point terminal block, complete all as directed. Each earth pit shall be include minimum 50kg (two bags of 25kg each) NABL lab Certified back fill compound and 6 kg (two container of 3kg Each) NABL Lab Certified conductive gel compound for filling bore holes with mother soil mixed in 1:3 ratio (one part of back fill compound and three part of mother soil), so as to achieve earth resistance below 1.0 Ohm including exacavation of polypit chamber with polyplastic pit cover (cost of poly pit chamber with polyplastic pit cover shall be deemed to be included in the quoted rates) including dismantling old UNSV earthing and removal thereof, complete all as specified and as directed by Engineer-in-charge. Make : Dhruva Technology Pvt Ltd/ Pragati/ Ashgel Electrode or equivalent. Notes : (a) Copper strip beyond test point shall be measured and paid separately (b) Contractor shall give guarantee of minimum 5 yrs for the earting carried out by him. (c) The quoted rates shall be included test point made of phosphorous bronze of size 75x75x25mm, drilled and screwed including 3 Nos 8mm dia 25mm long brass nuts and bolts. (d) Any other fittings /fixtures if technically required for archieving desired results (if not included above) shall be provided by contractor without any extra cost to Govt. (e) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to Govt.
M&L for preparation of old painted surfaces, removing dust and other deposited materials on HT tubular pole of 11 Mtr long by scraping and applying one coat of synthetic enamel paint up to 1 Mtr from bottom and painting the rest of the pole including cross arms, clamps etc, complete all as specified and directed. Note : Colour and pattern of the paint shall be decided by Engr-in-Charge.
M&L in replacement for HT cable route indicator, made out of GI plate 3mm thick and 6 inches dia duly marked with working voltage and route indicator, fixed with angle iron of size 25mm x 25mm x 3mm thick, 50cm long, embedded in PCC 1:2:4 type B-1, of size 20cm x 20cm x 20cm in ground, complete all as specified and directed.
Material & labour including Engineer/ Technician, to calibrate/ servicing the VCB in sub Stn of make Cromption Greevs as exists to trips immediately in case of fault (overload crunt earth falut) and replace minor parts i.e HRC fues 2 Amps, indictor lamp control wiring if required at site & make them 100% serviceable through out the year including servicing of VCB, oiling, greasing, cleaning with blower from inner and outer side, decarburizing of the links with CRC spray and checking serviceability of all mechanical parts, complete all as specified and directed. Notes :- (i) The above job will be carried out at perodicity of six month i.e 1st time within three month from the commencement of work and 2nd time within nine months. (ii) The rates for changing of minor parts is deemed to be included in quoated rates.
S&F in replacement TNC switch as per existing make & specifications, suitable for VCB 400 Amps,11 KV including necesarry connection & testing, complete all as specified and directed.
S&F in replacement closing coil assembly as per existing make & specifications, suitable for VCB 400 Amps, 11 KV including necesarry connection & testing, complete all as specified and directed.
S&F in replacement triping coil assembly as per existing make & specifications, suitable for VCB 400 Amps, 11 KV including necesarry connection & testing, complete all as specified and directed.
S&F in replacement indicator bulb 20 watt 1100 volt as per existing make, suitable for VCB/ OCB 400 Amps, 11 KV including necessary connection & testing, complete all as specified and directed.
S&F in replacement isolating contact assembly (set of 6 Nos) suitable for VCB 11000 volts, 400 Amps rating, 13.1 KA including necessary connection & testing as per existing make and specification, complete all as specified and directed.
S&F in replacement breaker phase barrier suitable for VCB/ RMU 11000 volts, 400 Amps rating 13.1 KA including necesary connection and testing as per existing make and specification, complete all as specified and directed.
S&F in replacement earthing contact assembly suitable for VCB/ RMU 11000 volts, 400 Amps rating 13.1 KA including necessary connection and testing as per existing make and specification, complete all as specified and directed.
S&F in replacement drive link assembly with adjuster (set of Three) suitable for VCB/ RMU 11000 volts, 400 Amps rating 13.1 KA including necessary connection and testing as per existing make and specification, complete all as specified and directed.
S&F in replacement motor with gear assembly single phase 230 volts suitable for VCB/ RMU 11000 volts, 400 Amps rating 13.1 KA including necessary connection and testing as per existing make and specification, complete all as specified and directed.
S&F in replacement motor charged mechanisam assembly with close/ trip coils & charging handle suitable for VCB/RMU 11000 volts, 400 Amps rating 13.1 KA including necessary connection and testing as per existing make and specification, complete all as specified and directed.
S&F in replacement base assembly of existing VCB including neccesary connection and testing as per existing make and specification, complete all as specified and directed.
S&F in replacement contact system for VD4 400 A (12 finger) suitable for VCB/ RMU 11000 volts, 400 Amps rating 13.1 KA including necessary connection and testing as per existing make and specification, complete all as specified and directed.
S&F in replacement potential transformer of fixed type, 3 phase, 3 limbs with HRC fuses mounted, suitable for VCB 11000 volts, 400 Amps, complete all as specified & directed. Make: ABB/GE/SIEMENS/CG.
S&F in replacement digital ammeter with shunt suitable for VCB 11000 volts, 400 Amps, complete all as specified and directed.
S&F in replacement digital Frequency with shunt suitable for VCB 11000 volts, 400 Amps, complete all as specified and directed.
S&F in replacement epoxy resin cast CT dual core of ratio as per existing accuracy class 0.55, burden 200/ 100/ 05 VA for 11 KV, complete all as specified and directed. Make : Vishal/Crompton/Concord.
Supply and replacement of epoxy resin cast CT dual core of ratio as per existing accuracy class 0.55, burden 100/ 50/ 05 VA for 11 KV, complete all as specified and directed. Make : Vishal/Crompton/Concord.
S&F maintenance free batteries 12 volt 180 AH including taking down old unserviceable bettery. Make : Amron/Exide SAP code FXPD-MHD Exide new express.
S&F maintenance free batteries 12 volt 100 AH including taking down old unserviceable bettery. Make : Amron/Exide SAP code FXPD-MHD Exide new express.
S&F in replacement battery charger of 24 V with boost charging and trickle facility and Amp and Volt meter, complete all as specified and directed.
S&F in replacement Drop out fuse 10 to 50 Amp in existing GOD at different locations, complete all as specified and directed.
S&F in replacement epoxy resin cast CT for HT metering, dual core of ratio as per existing accuracy class 0.50, burden 15/5A/7.5 VA for 11 KV, complete all as specified and directed. Make : Vishal/Crompton/Concord.
S&F in replacement epoxy resin cast PT for HT metering, dual core of ratio as per existing accuracy class 0.50, ration 11KV/ 110 V Burden 50 VA for 11 KV, complete all as specified and directed. Make : Vishal/Crompton/Concord.
S&F in replacement of GI strip of size 32 X 6mm, buried in ground upto 50cm or fixed to wall with insulators etc, for loop earthing including welding for joints, complete all as specifed and directed.
Taking down HT switch gear OCB of capacity 400 Amps, 11KV 250MVA comprising of the following repairs, overhauling servicing and refixing the same after repairs/ overhauling : (a) Dismantling of oil circuit breaker, oil tank and draining of oil, keeping it in safe custody for reuse. Checking contact finger assembly and main moving contact. (b) Dismantling the tank including replacing the gasket etc, by new gasket. (c) Dismantling and checking of cross bar assembly, fixed contact and current carrying parts of the breakers, trolly, insulated assembly and checking lamination with clamp, epoxy, spout, isolator assembly etc. (d) Setting reassembling, cleaning, adjustment of fixed contacts, main contracting contacts and chamber baffle pot assembly, moving contact for proper setting of auxiliary contacts operating mechanism. (e) Monting of oil tank after cleaning refilling the oil and tightening of the bolts after checking the breaker operation. (f) Checking setting and adjustment of lowering and raising operation of the brakers trolly. (g) Lubrication and greasing of alll moving parts of the trolly, stopper bolt for proper operating and closing of shutter gear, isolation resistance of trolley of with oil tank. Notes : (i) The quoted rate shall be deemed to include for necessary T & P, nuts, bolts, washers, gasket, HT insulation tape, compound etc to put in to the OCB and panels in serviceable condition, testing commissioning. (ii) Oil and required major spares parts will be measured and paid separately under relevant items of Sch 'A'. However the quoted rates shall be deemed to included for any other minor spares required at site.
Supply only the following spare parts, suitable for existing OCB 400 Amps, 250 MVA for repair works under Sch 'A' :-
Terminal bushing (Hinged end).
Tulip contact.
Moving contact (porker).
Contact finger assy (Without tip & lamination/ with tip & lamination).
Backing spring for finger contact.
Bus spout 3 phase/ circuit spout.
Busbar supporting 11KV insulators.
Arc pot contact assembly.
Shunt trip coil 110V DC/220 V DC.
CTs epoxy cast wound promary CTs with minimum primary current 60 to 400A, single.
Breaker control switch.
Fixed contact assembly.
AYOOB CONSTRUCTION COMPANY
Concept Engineering & Constructions
M/S Sky Engineers
M/S Noor Mohammad Shalla
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .