GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR/REPLACEMENT OF LT CABLES, LT OVERHEAD LINES, EARTHING, MCCBs, DG SETS, AMF PANEL AND OTHER CONNECTED WORKS AT DRDE GWALIOR UNDER GE I RnD DELHI
2022_MES_565836_1
GE/RND-87/GWL/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Gwalior
Class-D, Cat-b(i), b(ii)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹98,500
Yes
24 Jan 2023
28 Nov 2022
31 Dec 2022
28 Nov 2022
29 Dec 2022
17 Dec 2022
Amount
Restringing of existing ACSR’s conductors and earth wires including cradles, of any description, size & shape and in any position, as in LT/HT overhead lines, on existing poles, including opening of connections and binding wires, removing sag, binding to insulators with new aluminum wire, making and connecting jumper connections etc. including testing complete all as specified and directed. The quoted rates shall be deemed to include the following provisions also :- (i) Setting/adjusting the position of cradles. (ii) Old serviceable spacers of ACSR conductor shall be reused and fixed as directed
Dismantling & taking down of existing worn out / unserviceable aluminium conductor, steel reinforced (ACSR) of any description /size & in any position from existing LT/HT Poles/Lines complete all as specified and directed.
S&F of aluminium conductor, steel reinforced (ACSR) of any size/description on LT poles/lines including stringing, tightening, binding to insulators with aluminium wire making and connecting jumpers, connections etc including connecting, commissioning and testing complete all as specified and directed.
Re-fixing and stringing of old ACSR conductors and earth wires including cradles, of any description, size & shape and in any position, as in LT/HT overhead lines, on existing poles, including opening of connections and binding wires, restringing and tightening of conductors/earth wire in position, removing sag, binding to insulators with new aluminum wire, making and connecting jumper connections etc including testing complete all as specified and directed. The quoted rates shall be deemed to include the following provisions also :- (i) Setting/adjusting etc in position of cradles. (ii) Old serviceable spacers of ACSR conductor shall be reused obtained from item Ser No 2.00.
Dismantling & taking down of old existing mild steel articles items from poles such as cross arms of channels/sections, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts & bolts, washers of any description and in any position from LT over head line poles/ street light poles complete all as specified and directed.
Fixing only mild steel such as cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts & bolts, washers and including painting with one coat of synthetic enamel paint complete all as specified and directed. Note :- Old mild steel articles obtained from item Ser No 5.00 shall be reused.
Supply, fabrication and fixing for mild steel such as cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts & bolts, washers welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and including one primer coat, one under coat and one finishing coat of paint of any description of LT over head line poles/ street light poles complete all as specified and directed.
Dismantling & taking out of old existing unserviceable insulators of any description and in any position from LT/HT poles complete all as specified and directed.
S&F single disc assembly for disc type insulator porcelain vitreous 145mm high and 255mm dia ball and socket type, white , brown or green for HT 11 KV overhead line grade complete all as specified and directed.
S&F pin type porcelain, vitreous, white, brown or green insulators, including one galvanized mild steel spindle two galvanised iron washers and one galvanised iron nut, 150mm height and 150mm dia suitable for working pressure upto and including for 11000 volts HT line fixed on poles complete all as specified and directed.
All as per item Ser No 10.00 above but of size 100mm height and 65mm dia suitable for 1100 volts LT lines fixed on poles.
S&F Shackle type 75mm height and 90mm dia insulator, porcelain, vitreous, white, brown or green including galvanised mild steel strap 31mm x 3mm, insulator bolts 12mm dia with suitable washers and nut, suitable for working pressure upto & including for 1100 volts LT line fixed on LT poles complete all as specified and directed.
Disconnecting, dismantling and taking down existing unserviceable spacers of any description and in any position from the LT electric overhead lines of any height and supplying and fixing new best quality, waterproof & shockproof PVC insulated spacers, 12mm dia flexible type suitable for making / turning to any shape and size (straight or spiral) and suitable for 2 or 3 conductor runs complete all as specified and directed.
All as per item Ser No 13.00 above but spacers suitable for five conductors run.
All as per item Ser No 13.00 above but PVC insulated straight strip type spacers of width 25 mm suitable for five conductor run overhead lines.
Disconnecting, dismantling & taking out existing unserviceable gang operated switch & Supply, fixing, commissioning and testing of outdoor, gang operated switch, tilting type, 11KV of current rating upto 200 Amps, triple pole, each pole consisting of galvanized steel base, HT insulators as per IS, non ferrous knife and spray, loaded contacts, arcing horns of adequate section to break magnetizing current of the transformers, horizontal GI pipe of adequate length for phase separation, adequate length of GI pipes for operation from ground level and operating handle with locking arrangement complete in both OFF & ON positions. All ferrous parts hot dripped galvanized and non ferrous heavily tinned to with stand weather and suitable for vertical mounting complete all as specified and directed.
Dismantling 11 KV air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for insulators and operating mechanism and repair/replacement of broken/worn out components and insulators etc complete all as specified and directed. Note :- New spare parts replaced for GOD shall be measured and paid for separately under respective items of Sch 'A' BoQ as “supply only” but fixing element of same shall be deemed to be included under this item.
Supply only the following new parts suitable for GOD of 11KV repaired Note: - (i) The new parts shall be suitable to match with the existing GOD. (ii) Fixing element of these items is deemed to be included under the rates quoted by the contractor for respective Schedule `A' BoQ item No 17 above.
Supply only 11KV post type insulator
Supply only Male contact/moving contact blade.
Supply only Female contact/fix contact Jaw
Supply only MS Jumper carrier
Supply only Tinned copper flexible jumper
Supply only Back connector plate
Dismantling and taking down existing unserviceable lightening arrestor of any capacity and any description.
Supply, fixing commissioning & testing of lightning arresters HIGH TENSION 11000 Volt expulsion type complete with all fittings, transmission class discharge capacity 65 kilo Amp confirming to EC-99 -41/1990 including brackets, clamps, bolts, nuts and washers complete all as specified and directed.
Dismantling and taking down existing unserviceable Stay assembly set of any description complete all as specified and directed.
M&L for stay assembly comprising of 16mm dia, 1.80 metre long galvanized stay rod, having 7/3.15mm GI stay wire stranded and 230mm x 230mm x 6mm thick stay plate, complete all as shown on electrical plate No 1 of SSR, Part-I with and including all necessary fittings/ accessories like loop type insulator, stay clamps, necessary excavation and earth work in any type of soil and PCC works in 1:3:6 type C-2 (using 40mm graded stone aggregate) complete all as specified and directed.
All as per item Ser No 22.00 above but stay assembly having stay rod of 20mm dia and 2.15 metre long with 300mm x 500mm x 6mm thick MS plate complete all as specified and directed.
M&L for preparation of old painted surfaces of steel tubular strut pole of 9/11 mtr (LT/HT) including protection pipe, cross arms, clamps, GI pipe bracket of street/ security light , anti climbing devices etc. including scraping out old rusted paint and applying one coat of red oxide primer and two coat of aluminium paint on all the metallic surfaces complete all as specified and directed. Note: Numbering of the poles and repainting blue bands shall be done with synthetic enamel paint, letter/ band's shape & size shall be printed as directed.
Trimming/cutting of all trees branches and cleaning of bushes upto 2 metre distance both side from nearest conductor/earth wire at LT/HT overhead line including cleaning of site and depositing of material upto 50 metre distance complete all as specified and directed.
Surface excavation,grass cutting over the areas around the poles/feeder piller boxes/ sub stations not exceeding 15 cm depth including cleaning the bushes and vegetation/root of small trees and leveling including removal of surplus soil in soft/hard dense soil and depositing complete all as specified and directed.
Dismantling and taking down existing unserviceable/worn out danger notice plate of any description & any position and supply & fixing for danger notice plate 20x15 cm size and 1.6 mm thick mild steel vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) including demolition of existing as in coping including necessary form work or in any situation complete all as specified and directed.
Supplying and laying synthetic rubber insulated mats of sizes 2.0mX1.0m, 2 mm thick for voltage upto 3.3 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety complete all as specified and directed.
All as per item Ser No 29.00 above but 2.5 mm thick for voltage upto 11 KV (size 2x1m).
S&F in repairs MCCB 3 pole , 125 Amps, 415 Volts, 16 KA breaking capacity including connected accessories, spreader terminals and connection on existing DPX box complete all as specified and directed.
S&F in repairs MCCB, 3 Pole ,415 V , 160 Amp Adjustable type, with breaking capacity 36 KA including connected accessories, spreader terminals Model DPX 160 complete all as specified and directed.
S&F in repairs MCCB, 3 Pole ,415 V , Adjustable type,, 250 Amp with breaking capacity 36 KA including connected accessories, spreader terminals Model DPX 250 complete all as specified and directed.
S&F in repairs MCCB, 3 Pole ,415 V ,Adjustable type, 400 Amp with breaking capacity 36 KA including connected accessories, spreader terminals Model DPX 400 complete all as specified and directed.
S&F in repairs MCCB, 3 Pole ,415 V ,Adjustable type, 630 Amp with breaking capacity 50 KA including connected accessories, spreader terminals complete all as specified and directed.
S&F in repairs ON load change over switch with phase Barriers & Handle with door interlock kit and electrical interlocking , with SS enclosure 400 Amps, 4 Pole, 415 V, AC, 50 Hz complete all as specified and directed.
Material and labour for preparation of old painted surfaces of floor mounted indoor/outdoor type transformer for the following capacity by cleaning/rubbing with course cloth wire brushes to remove dust deposits, oil grease and painting with two coats of synthetic enamel paint complete including writing the SM No/MES No on transformers with white paint in the existing style/pattern complete all as specified and directed.
100 to 200 KVA
250 to 315 KVA
400 to 500 KVA
Dismantling and taking down the unserviceable breather assembly with silica gel complete for 100 KVA to 1000 KVA transformer and supply and fix cast iron breather assembly complete with breather unit and silica gel including connecting with proper rubberized gasket complete all as specified and directed.
Disconnecting defective indoor/outdoor type transformer of various capacities 100KVA to 160KVA from HT/LT sides taking out transformer oil completely storing the oil in suitable container (to be provided by the contractor) lifting the top cover and core assembly carefully and checking the condition, refilling the transformer oil completely after necessary repair, and fixing the top cover complete all as specified and directed. Note:- (a) Rewinding of the transformer shall be measured and paid separately. (b) In case of major repairs/replacement in transformer which cannot be undertaken at site the transformer shall be shifted to civil workshop and the quoted rate shall be inclusive of this aspect. (c) Dismantling of core and repairs shall be measured and paid separately.
All as per item Ser No 39.00 above but for transformer of capacity exceeding 200 KVA but not exceeding 315 KVA.
All as per item Ser No 39.00 above but for transformer of capacity exceeding 400 KVA but not exceeding 500 KVA.
All as per item Ser No 39.00 above but for transformer of capacity 1000 KVA .
Dismantling and taking out the existing unserviceable circuit tap changer assembly and supply and fix off circuit tap changer assembly suitable for any make of 100KVA to 500 KVA transformer with 7 tapping position including opening top cover breaker etc, complete all as specified and directed. Note: - Contractor is solely responsible for making good of any damage to transformer during tap changing operations.
Supply, filling and for topping up the transformer/OCB’s with new transformer oil duly filtered with filtration plant. Note:- (a) The transformer oil shall be type EHV confirming to IS 3357 of 1983 (b) Mineral oil grade 'B' shall be used. (c) The transformer oil should have a high dielectric strength not less than 40KV.
M&L for isolating the HT/LV supply from power transformer 2.00 to 3.15 MVA capacity by disconnecting HT 33 KV line & 11 KV line and opening clamps, bus bar extension and isolating disconnecting HT 33KV and 11KV connecting to transformer by opening clamps, bus bar extension and isolating the transformer from bus bar out door type, shifting the transformer to civil workshop. Decanning transformer oil complete taking out cores and windings from body and put in oven for heating the coils for improvement of insulation resistance till proper insulation results achived, cleaning transformer body inside and out side complete, painting with two coats of super enamelled paint inside and out side the body complete after scratching and removing old paint layers, refixing cores and coils in transformer body. Refilling oil, dehydration and filteration of oil to improve the dielectric strength /insulation value of transformer oil upto 60 KV and carryout test results such as megger test, Ratio Test, magnetic balance test, short circuit test, full load test, including replacement of wornout nuts bolts, all gaskets, packing sheets, sleeves, temp gauge etc complete reshifting the transformer at MRS install on platform and connecting HT 33 KV /11 KV connection incl replacement of clamps nuts bolts & washer complete connecting and making control wiring system in serviceable condition and testing of transformer on full load complete all as specified and directed. Note :- Test report of transformar shall be submitted to Engr-in-Charge signed.
Filtration/dehydration of transformer oil through filtration plant to improve the dielectric strength/insulation value of the transformer oil upto 60KV. Note : - (a) The contractor will take shut down orders in working before commencement of the work from Engineer-in-charge. (b) The contractor shall ensure no wastage in transformer oil (c) The contractor solely responsible for any damage to the transformer during filtration operations. He is responsible for making good any damage to the transformer at his own cost without any extra cost to the department (d) The contractor shall ensure that the conservator tanks are full to its level before starting the dehydration.
S&F in repair temperature gauge of existing specification/ Model for transformer of capacity 500 to 1000 KVA complete all as specified and directed.
M&L silica gel complete all as specified and directed.
Supply only insulation material PCB electrical grade such as barriers coil to coil insulation block and rings insulation cylinders, ebonite sleeves complete all as specified and directed.
Removing and refixing of new HT & LT coils/strips, disconnecting the 100 KVA to 160 KVA 11KV/433Volts indoor/outdoor transformer HT/LT side, taking out transformer oil completely, storing the oil in suitable container/barrels properly cleaned ones (to be provided by the contractor) lifting the transformer from the Sub station, shifting of transformer to civil workshop lifting the top cover and core assembly carefully and taking down 11KV/ 433 volts copper LT coils and 11KV HT coils from the transformer and S&F new HT & LT copper coil made out of proper size suitable for DPC copper wire of high quality suitable rating sleeve insulating materials like varnish etc, complete after necessary arrangement with new coils, necessary insulation spacing blocks, runners and proper refixing of core complete all as specified and directed.
Note:- (i) HT & LT copper coil/strips and insulation material PCB electrical grade such as barriers coil to coil insulation block and rings insulation cylinders, ebonite sleeves shall be measured and paid separately under relevant item of schedules/BOQ. (ii) The rate quoted is deemed to be included for cutting / chipping of RCC and for the minor grill work such as PCC, plastering foundation work. (iii) Proper drying shall be done in drying chamber after drying, taking the core coil assembly, filling the filtered transformer oil having good dielectric strength, replacement of suitable size rubberized cork gasket, bolts and nuts etc complete by fixing top cover, conservator etc, through cleaning and painting to the transformer with good quality paint complete and testing complete at civil workshop. (iv) Transformer oil shall be measured and paid separately under relevant item of schedule. (v) Installation of transformer, testing and connecting the both HT & LT cables, commissioning of transformer after checking voltage and all loading the transformer to the full load all as specified and directed. (vi) The cost of coil will be inclusive of varnish sleeving and insulating material.
All as per item Ser No 50.00 above but for transformer of capacity exceeding 160 KVA but not exceeding 315 KVA.
All as per item Ser No 50.00 above but for transformer of capacity exceeding 315KVA but not exceeding 500 KVA.
Supply only new LT copper strips made out of proper size of DPC copper strips super enameled of high quality matching with the existing impedances and insulation for 100 to 1000 KVA transformer complete all as specified and directed.
Supply only new HT copper coil made out of proper size DPC copper wire super enameled of higher quality matching with the existing impedance and insulation for 100 to 1000 KVA transformer complete all as specified and directed.
S&F with replacement HT bushing assembly including brass stud nuts washers insulators etc. suitable for indoor/outdoor transformer of capacity 100 to 1000 KVA complete all as specified and directed.
S&F with replacement 12mm dia LT bushing assembly including brass stud nuts, check nuts washers oil seal insulators etc complete all as specified and directed.
All as per item Ser No 56.00 above but of size 16mm dia
All as per item Ser No. 56.00 above but of size 20mm dia
Labour only for Inspecting/Checking for operation of the servo voltage stabiliser 400 KVA to 1000 KVA, servicing /maintenance up to satisfactory level, so that the constant output voltage (For single phase 230-240 Volt & for 3 phase 415 volt with +- 2.5% volt correction factor ) can be supply to labs,in respective incoming voltage 360 Volts to 470 Volts with any variation in phase to phase complete all as specified and directed. Note: Spare parts requied for replacement shall be measured and paid separately as supply only.
Supply only Servo digital panel
Supply only Servo motor
Supply only Voltmeter 96mm up to 500 Volt
Supply only Ampmeter 96 mm
Supply only RC
Supply only Carbon (bush)
Opening the 1000 KVA transformer cover along with the conservator by removing the nut bolts then after removing the internal HT & LT connections by taking them out by removing studs, bushings taking out the core winding assembly out of the tank of the transformer, cleaning of core assembly by spraying forced TR oil, having ratio 11/0.433KV, draining & decanting of burnt transformer oil and clearing of sludge deposited in the tank with CTC for the transformer. Reconditioning of LT coil, Heating of core winding assembly in hot chamber for 48 hours and remove all the moisture present in it, removal of leakage of tank if any by carefully welding, refilling transformer oil to tank with filteration upto suitable die electric strength to tank, after putting the core-winding assembly into the tank, reassembling making the internal HT & LT connections by fixing the studs, bushing & fitting top cover by replacing cork sheet gasket along with conservator, testing the transformer in the workshop duly filled with oil, including transportation of transformer from site to workshop and vice a versa complete all as specified and directed, for various capacities as under:- Note:- (i) Unserviceable items required for repairs shall be measured and paid under relevant item of this schedule. (ii) Transformer oil with di electric strength not less than 40 KV either new or filtered shall be filled and shall be measured and paid separately under respective item.
Dismantling & taking out of old existing PT 11 KV and supply, fixing & testing protection PT for 11 KV VCB/OCB complete all as specified and directed.
M&L for jointing and testing outdoor type heat shrinkable end termination joint suitable for 11 KV, XLPE insulated cable of 95 Sqmm 3 core including taking out old unserviceable, cutting the faulty outdoor end termination joint of any description and in any position complete all as specified and directed. Note :- (i) All Necesary T & P Blow lamp, HT Megar shall be arrange by the Contractor. (ii) The contractor has to rectifiy the joints within 4 Hrs after detecting of the faults. In case of failure, penalty of Rs 1000 per hours shall be recovered from contractor dues.
All as per item Ser No 62.00 above but for cable of size 120 sqmm to 185 sqmm 3 core.
Disconnecting, taking out and removing old existing unserviceable underground, LT cable of any description and in any position complete including taking down protection pipe, PCC Cover/Bricks etc complete all as specified and directed for the following sizes:-
35 Sqmm to 70 Sqmm any core
95 Sqmm to 150 Sqmm any core
185 Sqmm to 300 Sqmm any core
Relaying old serviceble LT cable of following, jointing and testing any description and any size laid in trenches/ducts, floors, fixed to walls etc complete all as specified and directed.
35 Sqmm to 70 Sqmm any core
95 Sqmm to 150 Sqmm any core
Supply, laying, jointing and testing XLPE insulated, armoured, heavy duty, aluminium conductor cable 1100 volts grade of any description laid in trenches/ ducts, floors, fixed to walls etc complete all as specified and directed of the following sizes :-
35 Sqmm 3.5 core
50 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
150 sqmm 3.5 core
185 Sqmm 3.5 core
300 Sqmm 3.5 core
Excavation in trenches in soft/loose soil not exceeding 1.5 metre deep and not exceeding 1.5 metre width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc including removing cable protection, PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m complete all as specified and directed. Note : Excavation shall be made carefully in order to avoid damage of existing cables and protection covers.
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed
Removal of surplus excavated soil exc. 50 Mtr but n. exc. 250 Mtr distance and depositing where directed at a level not exceeding 1.5 metre above the starting point etc complete all as specified and directed.
M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed . Note : - Punned thickness shall be measured and paid.
Supplying & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed.
Laying only old serviceable Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed.
Material and Labour for earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 25x4 mm by means of Copper nuts, bolts and washers. Strip shall be laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20 mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly be tightened on GI watering pipe and embeded in PCC earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar @75mm centre to centre with 2 Nos MS handles of 12mm dia mild steel TMT bars suitable for carrying of pit cover.
S&F in repair earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 25x4mm galvanised iron strip complete all as specified and directed.
Disconnecting & Taking out old unserviceable joints and Supplying, Fixing, jointing and testing for straight through joints, epoxy type with epoxy jointing materials, suitable for XLPE, LT Cable, 1100 Volts grade, for the following sizes of cables complete all as specified and directed.
25 Sqmm to 35 Sqmm 3.50 core.
50 Sqmm to 70 Sqmm 3.50 core.
95 Sqmm to 120 sqmm 3.50 core.
S&F in replacement LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
S&F in repairs Automatic Transfer Switch, 3 phase , 4 pole , AC, 415 Volts 160 Amps rating within enclosure with controller and complete protection for Automatic or manual operation complete all as specified and directed.
Supply & fix in repair busbar chamber 6 way with aluminium busbars for MCCB's upto rating 400 amps for three phase four wire system having separate earth link complete all as specified and directed.
M&L for repairing / servicing the existing unserviceable Air Circuit Breaker of 800 Amp capacity for proper functioning on overload and earthfault by replacing the wornout parts, all cable ends incuding replacing the unserviceable lugs etc, cleaning the dust by blower complete all as specified and directed. Note:- (i) Wornout/unserviceable parts of ACB will be paid & measured separately under respective item of schedule.
Supply only Lockable trip push button (LTPB) kit of 800 Amps Air circuit breaker .
Supply only contact spring.
Supply only moving contact.
Supply only Door interlock
Material and Labour for earthing complete with copper earth plate electrode 600mmx600mmx3.15mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. Copper plate connected with copper strip of 20x3 mm by means of copper nuts, bolts and washers. Strip shall be laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) Copper strip of size 20mm x 3mm. (b) Watering pipe GI light grade 25mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly be tightened on GI watering pipe and embeded in PCC earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar @75mm centre to centre with 2 Nos MS handles of 12mm dia mild steel TMT bars suitable for carrying of pit cover.
Supply, installation, Commissioning and testing LT panel board of size 1540mmX1200mmX500mm (approximate) as approved for 3 phase, 4 wire, 415 Volts ,AC , 50 Hz supply,CPRI approved, Outdoor cubical type Double door, dust and vermin proof, pedestal mounting type suitable for Outdoor applications, made out of 3.15 mm thick MS sheet with using 40mm x 40mm x 5mm angle iron frame and supports, duly finished with powder coated using two coats of synthetic enamel paint of approved colour over a coat of red oxide primer all over steel surfaces complete with separate compartment of suitable shape and size with shutter and locking arrangement for each switchgear and including PCC work for fixing panel legs. Bus bar of aluminium conductor suitable shape and size for 3 phase rating of 800 amps and for neutral 600 Amps rating including taking out end connectinons of the existing cables and fixing the cable with the panel using new lugs and glands of suitable size, separate cable alley for outgoing cables comprising of following accessories and taking out unserviceable LT Panel from existing site complete all as specified and directed
M&L for servicing /preventive maintenance of DG set of capacity 160KVA to 320 KVA at site comprising of the following check & re adjust valve tapped clearence in cold, drain out used engine oil by opening the oil chamber ,cleaning the chamber throughly, pouring the new engine oil refixing the chamber cover with new gasket , replacement of diesel filter, oil filter, air filter, cleaning the diesel tank, clean radiator fins & air to air after coller & AVM pads, check rubber seal and hose pipes replace if found defective, check coupling disc on injection pump, check speed of governer for proper functioning and lubricating in linkages, check clean air filter element, check functioning of engine protection unit repair to instruments panel, check and repair of any leakage etc.and replacement of small minor items such as nut, bolts, washers, etc are included in quoted rates of sch A' complete all as specified and directed. Note: Engine oil and filters shall be measured & paid separately under respective items.
Supply only Fuel Filter 160 KVA to 320 KVA complete all as specified and directed.
Supply only Pre fuel filter for 160 KVA to 320 KVA complete all as specified and directed.
Supply only Air clean element primary for 160 to 320 KVA complete all as specified and directed.
Supply only Air clean element secondary for 160 to 320 KVA complete all as specified and directed.
Supply only Oil Filter Assembly 160 to 320 KVA complete all as specified and directed.
Supply only Set of rubber ‘O’ ring 160 KVA to 320 KVA complete all as specified and directed.
Supply only Pipe air cleaner to turbocharger 160 KVA to 320 KVA complete all as specified and directed.
Supply only Hose pipe & Flexible pipe for DG set 160 KVA to 250 KVA complete all as specified and directed.
Supply only Fan belt for water pump for DG set 160 KVA to 320 KVA complete all as specified and directed.
Supply only Fan belt for alternator dynamo for DG set 160 KVA to 320 KVA complete all as specified and directed.
Supply and filling in replacement of engine oil 20 W 40 and as type required at site complete all as specified and directed.
Supply and filling of coolant for radiator DAFC 30 % complete all as specified and directed.
Supply and fix in replacement of FIP assembly for DG set of cap 160 to 320 KVA complete all as specified and directed.
Dismantling and calliberation of fuel pump of DG Set of any capacity including replacement of seal and kit including refixing and testing complete all as specified and directed.
S&F in replacement of water pump assembly complete all as specified and directed.
Dismantling and taking down alternator assembly from existing engine and carry out servicing / maintenance of alternator of capacity 160/250/320 KVA DG set as per the phase work :- (a) Opening of Alternator and cleaning / removing dust from armature and field coil. (b) Cleaning of used / old lubricated substances drive/non drive end bearings. (c) Cleaning end checking of AVR unit (d) Checking and tightening of coupling bolts and replacement of rubber gasket. (e) M&L for carrying out heat varnishing for field and armature coil and kept in heating chamber for 48 hours for drying properly. (f) Replacement of Bearings as per existing size. (g) Reassembling complete unit and carrying out testing at workshop and transportation to installation and coupling with DG Set including necessary alignment, cable connections complete all as specified and directed.
Supply only carbon brushes for capacity 160 to 320 KVA DG set complete all as specified and directed.
Supply only petrolium jelly complete all as specified and directed.
Cleaning and scraping of old painted surface of 160/250/320 KVA DG set including removing of oily substances for painting of complete DG Set (such as Engine, alternator, base frame, inlet/out let pipes, fuel tank cylindrical/square type with stand, LT control panel board, concrete platform) by using first quality automotive paint as per MES colour codes including canopy and letter writting of SM/MES No and out going feeder names on LT panel complete all as specified and directed.
S&F sensing/control card for digital control panel for capacity 160 to 320 KVA complete all as specified and directed.
S&F in repair governor suitable for 320 KVA DG set complete all as specified and directed.
S&F in replacement of self starter 24 volts type SM-130-24 volts7.5 KW complete all as specified and directed.
S&F in replacement of self starter 12 volts Suitable for DG set 160/250/320 KVA complete all as specified and directed.
S&F in replacement of maintenance free battery 12 volts,180 AH complete all as specified and directed.
S&F in replacement of battery charger auto type 24 volts x 10 amps complete all as specified and directed.
S&F in replacement of battery charger auto type 12 volts x 8amps complete with all accessories complete all as specified and directed.
Dismantling and opening of turbo charger assembly of 160 to 320 KVA DG Set and repair/overhauling and replacement of turbo charger kit including refixing, testing complete all as specified and directed.
Supply only distilled water packed in containers complete all as specified and directed.
Supply only acid Mixture gravity 1200-1220 (Electrolite) packed in 1 ltr bottle packing complete all as specified and directed.
M&L for buttery lead heavy duty multi strands copper of size 25 sq mm 4 feet long in red and black colour complete all as specified and directed.
M&L for replacement of heavy duty brass terminals suitable for 24 volts /12 volts batteries complete all as specified and directed.
S&F of flywheel ring for 160 KVA to 320 KVA capacity DG Set complete all as specified and directed.
M&L for repair to 24 volts self starter assembly by taking out from DG Set of any make and size including transporting the same to work shop in market for repair and replacement of new items like armature, field coil with enameled copper conductor of existing gauge including insulating material and heat varnish ,DE bearing bush, CE bush armature, carbon brush including petrol wash. Refixing the same after repair and testing on full load complete all as specified and directed.
All as per item Ser No 115.00 above but for 12 volts self starter assembly.
M&L for Repair/servicing of radiator assembly of 160/250/320 KVA DG Set after dismantling and removing cooling fans, guard plates and lowering the same from engine after draining out water from radiator and scrapping / removing sludge / scale inside tank with acid including replacement MS tank (bottom portion) at rusted portion by cutting/ welding / brazing with 2mm thick copper plate including painting remounting the same at its original position and replacement of pre-mixed coolent and testing complete all as specified and directed. Note:- Pre mixed coolent shall be measured and paid separately under relevant item of schedule.
S&F in replacement of HRC fuse DIN type breaking cap 100 to 200 Amp with fuse base for DIN type HRC fuse links complete all as specified and directed.
S&F in replacement of HRC fuse DIN type breaking cap 220 to 380 Amp with fuse base for DIN type HRC fuse links complete all as specified and directed.
S&F in replacement of HRC fuse DIN type breaking cap 400 to 600 Amp with fuse base for DIN type HRC fuse links complete all as specified and directed.
S&F in replacement of automatic digital control unit with display of DG set parameters complete all as specified and directed.
S&F in replacement of MCCB ,four pole 100 Amp current rating and ultimate breaking capacity LCS=100 % Icu 16 KA with thermal magenetic realese and adjustable overload setting having type DPX3 confirming to IS 13947 & IEC- 60947 complete all as specified and directed.
S&F in replacement of MCCB ,four pole 160 Amp current rating and ultimate breaking capacity LCS=100 % Icu 25 KA with thermal magenetic realese and adjustable overload setting having type DPX3 confirming to IS 13947 & IEC- 60947 complete all as specified and directed.
S&F in replacement of MCCB ,four pole 250 Amp current rating and ultimate breaking capacity LCS=100 % Icu 36KA with thermal magenetic realese and adjustable overload setting having type DPX3 confirming to IS 13947 & IEC- 60947 complete all as specified and directed.
S&F in replacement of off load change over switch 4 pole 415 volts 200 Amp rating advance neutral, open execution handle assembly having door interlock and padlocking arrangement complete all as specified and directed.
S&F in replacement of off load change over switch 4 pole 415 volts 400 Amp rating advance neutral, open execution handle assembly having door interlock and padlocking arrangement complete all as specified and directed.
S&F in replacement of digital voltmeter (0.5) 3 phase 0 to 500 volts mains opetated having 2.5 digit LED/LCD/FND display mounting type for measuring phase volts complete all as specified and directed.
S&F digital ammeter (0.5) 3 phase digital meter range 0-300 Amp along with suitable size CTs having 3.5 digit LED/LCD/FND display mounting type for measuring phase volts complete all as specified and directed.
S&F in replacement of digital frequency meter (0.2) having LED/LCD/FND display mounting type for 50-60 hz complete all as specified and directed.
S&F in replacement of self sequentional starting relay unit 24 volts DC with dual interlocking timer for self on ,(3 sec-15 sec) adiacent independently with another timer for set fails to starety alarm complete all as specified and directed.
S&F in replacement of LED illuminating flush push buttons 22.5 mm dia in three coloures as red ,yellow & blue without contact block and carrier complete all as specified and directed.
S&F in replacement of LED pilot lamp head 22.5 mm dia in three colours as red, yellow. And blue without contact block and carriers complete all as specified and directed.
S&F in replacement of plug in relay universal type 11 pin contact rating 10 amps 24 volts DC and mechenical indicator with manual testing /latching lever complete all as specified and directed.
S&F in replacement of plug in relay universal type 11 pin contact rating 10 amps 230 volts DC and mechenical indicator with manual testing /latching lever complete all as specified and directed.
S&F in replacement of 3 pole AC control power contactor,415 volts, . Phase 50 Hz rated operational current 70 TO 100 amp. & AC 3 rating confirming to IEC-60947 in AMF Panel complete all as specified and directed.
S&F in replacement of 3 pole AC control power contactor,415 volts, . Phase 50 Hz rated operational current 200 amp. & AC 3 rating confirming to IEC-60947 in AMF Panel complete all as specified and directed.
S&F in replacement of 3 pole AC control power contactor,415 volts, . Phase 50 Hz rated operational current 260 AMP TO300 amp. & AC 3 rating confirming to IEC-60947 in AMF Panel complete all as specified and directed.
S&F in replacement of 3 pole AC control power contactor,415 volts, . Phase 50 Hz rated operational current 400 amp. & AC 3 rating confirming to IEC-60947 in AMF Panel complete all as specified and directed.
S&F in replacement of 3 pole AC control power contactor,415 volts, . Phase 50 Hz rated operational current 630 amp. & AC 3 rating confirming to IEC-60947 in AMF Panel complete all as specified and directed.
S&F in replacement of contactor coil MNX-140 complete all as specified and directed.
S&F in replacement of AVR suitable for 160 KVA capacity DG set complete all as specified and directed.
S&F AVR suitable for 250/320 KVA capacity DG set complete all as specified and directed.
S&F in replacement of existing voltage relay 415 volt 3 phase complete all as specified and directed.
S&F in replacement of multi control relay as per existing sample complete all as specified and directed.
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 25x5 mm by means of Copper nuts, bolts and washers. Strip shall be laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) GI strip of size 25mm x 5mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly be tightened on GI watering pipe and embeded in PCC earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm dia mild steel TMT bars suitable for carrying of pit cover.
M&L in repair earth continuity conductor providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia GI pipe light grade from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc complete all as specified and directed.
S&F in replacement, retro reflective installation board made out of acrylic sheet, size 1.2 x 1.0 Mtr. Writing with computer graphic marking, size of letter not more than 50 mm in length with approved white letter writing on blue back and border of 10mm all around including necessary grouting the installation board with PCC 1:2:4 with 20mm graded stone aggregate upto the depth of not exc. 50mm from ground level and to the ground with angle iron of size 40x40x6mm complete with necessary frame work, welding, bending etc complete all as specified and directed.
GUPTA ENGINEERING WORKS
anand enterprises
M/s Mahesh Engineering Works
M/S ISLAM AND BROTHERS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .