| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹43.4 L+₹7.6 L (21.2%)Rejected-Finance C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L2 | Rejected-Finance Highest bid quoted other then L1 |
Tender Value
Refer Docs
EMD Value
₹73,900
Closing Date
14 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Sri Ganganagar
Garrison Engineer Sri Ganganagar, Military Engineer services , Sri GanganagarCantt Rajasthan-335001
PROVN OF CERTAIN MW AND RW AT MIL STN SRI GANGANAGAR
2023_MES_624214_2
GE SGNR/TOK-54 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
Sri Ganganagar(Raj)
D Class a(i) and b(i) and for un-enlisted, refer NIT para 8.
7 documents required · 7 mandatory
₹500
GE Sri Ganganagar
₹73,900
Yes
25 Jan 2024
23 Nov 2023
16 Dec 2023
23 Nov 2023
14 Dec 2023
30 Nov 2023
Amount
Demolition of RCC of any descrition such as Kitchen chimney, chajja, shelves, OHT Tanks. or in similar work etc and in any position not other wise specially provided for complete all as specified and directed by Engineer in Charge (reinforcement cut as required to facilitate demolition) complete all as specified and directed by Engineer-in-charge
M&L for reinforced cement concrete type B1 1:2:4 (20 mm graded aggregate) as in slab supported on walls, beam and column in floors, roofs ,landings, balconies, deck slab, parapet walls and in shelves and etc and setting in mortar complete with joints to match complete all as specified and directed by Engineer-in-charge
Formwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed by Engineer-in-charge
M & L mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia complete all as specified and directed by Engineer-in-charge
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches , pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed by Engineer-in-charge
M&L brick work with sub class B bricks straight or curved on plan exceeding 6 mtr mean radius in cm 1:6 etc complete all as specified and directed by Engineer-in-charge
Dismantling of brick tiles or terracing tiles single layer on roof including also taking down existing APP membrane & disposal of retrieved material upto a distance n.exc 100m where complete all as specified and directed by Engineer-in-charge
Demolition of mud in roof, any thickness including plastering and leaping (where full thickness removed or only a part there of disposal off rubbish upto a distance n.exc 100m, complete all as specified and directed by Engineer-in-charge
M&L for Roof treatment to RCC roof as follows :- (a) Cleaning the roof surfaces thoroughly using wire brushes to remove sharp projections,cleaning joints,washing,drying and removing all dirt/dust to receive concrete padding/ plaster etc complete all as specified and directed by Engineer - in - Charge. (b) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:4) with WPC , finished even and smooth without using extra cement. (c) Providing one coat of approved bituminous primer @ 100 gms per sqm, over dried plastered surface. (d) Laying 3 mm thick APP based polymeric membrane,minimum weighing 3 Kg/Sqm reinforced with non woven polyster fabric (weight not less than 150 gms/Sqm) by torch application. The overlapping while torching shall be 75 mm on longitudinal direction and 100 mm on the transverse direction complete all as specified and directed by Engineer-in-Charge. Makes:-STP, Dr Fixit, Sika Notes: (i) All joints and change in directions should be covered with cement mortar (1:3) mixed with SBR latex @ 200 ml/bag of cement/ as per site requirement and cured well before laying membrane by torching. (ii) All angles and abuttments should be sealed well with extra care to ensure full bondage. (iii) Water proofing treatment shall be got carried out by approved authorised applicator of manufacturer only.The name of firm shall be got approved from GE before carrying out the work. (iv) The independent testing of membrane for technical parameters given in particular specifications shall be carried out from Govt approved labs having fascilities for testing of membrane. (v) The guarantee of treatment shall be for minimum 10 years reckoned from date of completion of whole work
S&F heat resistance tiles of size 300x300x10mm thick on roof slab of any colour approved over and laid including 15mm thick in CM 1:4.Techinical specification of roof tiles shall be as prer IS 4457:2007 complete all as specified and directed by Engineer - in - Charge.
M&L PCC 1:2:4, type B1 using 20 mm graded stone aggregate as in roof kerbs / benching / coved fillets etc rounded or chamfered on edges, complete all as specified and directed by Engineer-in-charge
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed by Engineer-in-charge.
M&L, 15mm thick rendering/plastering 15 mm thick on any face of brick wall or concrete surface consisting in two layers i.e. First laye 10 mm thick in cement mortar (1:4) and second (top layer) layer 5 mm thick in cment mortar (1:4) including mixing of liquid WPC in mortar @ as per manufacturer instruciton per bag of cment of 50 Kg, finisied even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge. (Note WPC shall be measured & paid separately as supply only)
M&L, 5mm thick rendering in CM 1:3 on fair faces of concrete surfaces as on ceilings finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L, 15mm thick rendering in CM 1:6 on fair faces of brick or concrete wall surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
Supply only integral water proofing compound, ISI Marked complete all as specified and directed by Engineer-in-charge.
M & L Preparation of new plastered surfaces of wall and applying two coats of cement base paint over upto 2-3 mm thick wall putty over one coat of alkali resistant primer complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surface of wall any description and applying two coats of oil emulsion distemper over upto 2-3 mm thick wall putty over a coat of chalk whiting layer on plastered surfaces preparatory to distempering complete all as specified and directed by Engineer-in-charge.
M & L for three coats of white washing on new plastered surfaces of on ceiling surface including preparation of surface complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old surface including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and removing all dirt and dust by watering making surface even and smooth and then applying two coats of cement base paint over over upto 2-3 mm thick wall putty well prepared old decorated plastered surface etc complete all as specified and directed by Engineer-in-charge.
M & L for preparation of old decorated wall surfaces by brooming down or steel wire brushing,scrapping down smoke soot,moulds,moss and efflorescent salts and trading oil and greasy spots and then applying two coat of oil bound distemper over 3 mm thick wall putty complete all as specified and directed by Engineer-in-charge.
M & L for old decorated ceiling surfaces by brooming down or steel wire brushing,scrapping down smoke soot,moulds,moss and efflorescent salts and trading oil and greasy spots and then applying two coats of white wash complete all as specified and directed by Engineer-in-charge.
Taking up or down GI tubing 15 mm bore pipe including cleaning for re-fixing or removal to store complete all as specified and directed by Engineer-in-charge.
Ditto- but refixing 15 mm dia ,old steel tubing and connections in new or old possition (wall,ceiling and floors etc) complete all as specified and directed by Engineer-in-charge.
S&F GI tubing 15 mm bore medium grade galvanise with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 15 mm complete all as specified and directed by Engineer-in-charge.
Taking up or down GI tubing 20 mm bore pipe including cleaning for re-fixing or removal to store complete all as specified and directed by Engineer-in-charge.
Ditto- but refixing 20 mm dia ,old steel tubing and connections in new or old possition (wall,ceiling and floors etc) complete all as specified and directed by Engineer-in-charge.
S&F GI tubing 20 mm bore medium grade galvanise with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 20 mm complete all as specified and directed by Engineer-in-charge.
Dismantling PVC water tanks and removing for capacity exceedin 250 litres & not exceeding 500 litres etc., complete all as specified and directed by Engineer-in-charge.
S&F 1000 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical, vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete all as specified and directed by Engineer-in-charge.
S&F 20 mm ball valve high pressure of PTMT with apoxy coated aluminium rod and high density plastic ball screwed for iron pipe, complete all as specified and directed by Engineer-in-charge.
S&F gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20 mm bore, complete all as specified and directed by Engineer-in-charge.
Demolition and breaking up or taking down PVC/AC/CI/SSW 100mm bore pipe drain pipes, set in cement mortar including PCC haunching and bedding, complete all as specified and directed by Engineer-in-charge
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including PVC holding clamps, complete all as specified and directed by Engineer-in-charge
S&F 110mm bore PVC (SWR) bend, any radius with access door complete all as specified and directed by Engineer-in-charge
S&F 110mm bore PVC (SWR) vent cowl complete all as specified and directed by Engineer-in-charge.
S & F Stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays for 100mm bore of pipe, including bolts and nuts and securing ends of stays to wall or roof etc complete all as specified and directed by Engineer - in - Charge.
Material and labour for mild steel ISMB, joist, channel, angle or tee section , fixed adjacent to ceiling and embedding in floor and brick work inlcuding cutting welding, without connecting platges etc (cut to ordinary lengths i.e. Within 20 mm of the length indicated) FE-410 W (Gde E-250) quality 'A' complete all as specified and directed by Engineer-in-charge.
Material and labour for GI wire netting 0.90 mm dia and 12 mm mesh lathing by means of fasterners of required length and spacing between fasterners is 300 mm centre to centre both ways to concrete surface etc in walls, ceilings, stanchions, beams etc including all laps, cutting and waste complete all as specified and directed by Engineer-in-charge.
Taking down steel window / ventilators complete all as specified and directed by Engineer-in-charge.
Taking down chowkats or frames (without taking off shutters from the frame) not exceeding 1.5 sqm each complete all as specified and directed by Engineer-in-charge.
S& F powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer-in-charge.
S&F powder coated Anodised aluminium window and ventilator shutters, side hung type without sash bars,aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws and sliding aluminium channel, wheels and locking arragements , anodised aluminium fittings such as peg stays 150mm long, hinges type B-21 100mm long, suitable handle and tower bolt as per requirement complete all as specified and directed by Engineer-in-charge.
S&F Anodised aluminum grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15 ) of approved design /pattern, with approved standard section and fixed to the window /door with C.P brass/SS screw @ 200mm centre to centre , including cutting the grill to proper opening size for fixing and operation of handles including flyproof wire mesh. Note:- Design shall be approved by Engineer - in - Charge. Note :- Minimum thickness of powder coating shall not be less than 50 micron.
S&F powder coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, including sliding channel with complete arragement, hinges,powder coated aluminum snap beading screws etc. ccomplete all as specified and directed by Engineer-in-charge.
Providing, cement concrete type B 1 (1:2:4) ( 20 mm aggregate) in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by Engineer-in-charge.
M&L75 mm thick cement concrete type D2, 1:4:8 (Using 40mm graded stone aggregate) filling sub base as in floors, paving, sub floor etc finished even and smooth complete all as specified and directed by Engineer - in - Charge.
M&L 25mm thick cement concrete flooring type B0, 1:2:4 using 12.5 mm graded aggregate finished even and fair complete all as specified and directed by Engineer - in - Charge.
M&L for sand filling (25mm thick) under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer - in - Charge.
M&L Machine pressed precast rubber moulded concrete coloured interlocking paver block any shape and size confirming to IS 15468-2006 of 60 mm thickness with grey cement and pigment M-35 Grade 20mm graded stone aggregate) complete all as specified and directed by Engineer - in - Charge.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.50 Mtr in depth for foundation, etc., not exceeding 10 Sqm on plan in soft /loose soil; & getting out complete all as specified and directed by Engineer - in - Charge.
M&L for PCC as in foundation type D-2 1:4:8 (40mm graded stone aggregate) complete all as specified and directed by Engineer-in-charge.
M&L for Reinforced Cement concrete (design mix) M-25 using 20mm graded aggregate in foundations, footings, plinth beams etc complete all as specified and directed by Engineer-in-charge.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams;and similar work; vertical or to better for flat rough finished surface of concrete etc.complete all as specified and directed by Engineer-in-charge.
M&L for Reinforced Cement concrete (design mix) M-25 in columns, pillars, piers, posts and struts complete all as specified and directed by Engineer-in-charge.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions for square, rectangular or polygonal rough finished surface complete all as specified and directed by Engineer-in-charge.
M&L Reinforced Cement concrete (nominal mix) 20mm graded stone aggregate in slabs supported on walls, beams and columns , in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-charge.
Formwork to soffits of suspended slabs such as roof slabs,floor slabs thickness n. exc. 200mm in fair finish complete all as specified and directed by Engineer-in-charge.
Formwork to edges of concrete flats and similar works thickness n. exc. 200 mm in rough finish complete all as specified and directed by Engineer-in-charge.
M/L for TMT bar 8 mm dia cut in shape length incl cranking bending etc and binding with and incl MS wire not less than 0.9 mm complete all as specified and directed by Engineer-in-charge.
Damp Proof course, 40mm thick in PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate to horizontal or vertical surfaces including mixed with water proofing compound as per manufacture instructions including necessary form work complete all as specified and directed by Engineer-in-charge. NOTE : Supply only WPC to be measured and paid separately.
M&L brick work with Fly Ash old size bricks straight or curved on plan exceeding 6.0m mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer-in-charge.
M&L brick work with Fly Ash old size bricks straight or curved on plan exceeding 6.0m mean radius in half brick thick walls built in cement mortar 1:6 complete all as specified and directed by Engineer-in-charge.
M&L 15mm thick rendering in CM 1:4 to brick / concrete wall surfaces finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L hardcore of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-charge..(Broken bricks)
M&L 75 mm thick PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in sub base flooring. complete all as specified and directed by Engineer-in-charge.
M&L for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed in CM 1:6 complete all as specified and directed by Engineer-in-charge.
M&L 450x300 x7/600x300x7 mm thick glazed ceramic coloured tiles as in vertical sufaces such as skirting or dado set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles and incliding 10mm thick backing coat in CM 1:4. complete all as specified and directed by Engineer-in-charge.
M&L providing 75 mm thick cement concrete type 1:3:6 (20 mm graded) C-2 as in Plinth protection complete all as specified and directed by Engineer-in-charge.
S&F fiber glass reinforced plastic (FRP) Door frames of three legged of cross section 90mmx45mm having single rebate of 32mmx15mm to receive shutter of 30mm thickness. The laminate door frame molded with fire retardant grade unsaturated polyster resin and chopped mat. door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be covered with fiberglass from all sides. M S stay shall be provided at the bottom to steady the frame complete all as specified and directed by Engineer-in-charge.
S&F 30mm thick fiber glass reinforced plastic (FRP paneled Door Shitter of required colour and approved brand and manufacture made with fire-retardant grade unsaturated polyster resin. Moulded to 3mm thick FRP laminate for forming places for fixing of fittings cast monolithically with 5mm thick FRP laminate for panels and conforming to IS 14856-2000 including 03 x 100mm long butt hinges, heavy weight, cold rolled mild steel, 150 mm long aluminium handle cast type anodised, 01 x aluminium anodised barrel tower bolts of extruded section 150mm long complete all as specified and directed by Engineer-in-charge.
M&L anodised aluminium frames for doors, windows with one or moe rebates including jointing cleats for fixing etc.including power coating minimum thickness of power coating shall be 50 micron as per the specification) ccomplete all as specified and directed by Engineer-in-charge.
S&F powder coated aluminium windows and ventilator shutters, side hung type, without sash bars aluminium saction weighing 0.55 kg/RM including necessary jointing cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fitting such as peg stay 150mm long (1 no) hinges type B21 100 mm long (2 No) suitable handle (1No) including aluminium grill and wire mesh complete all as specified and directed by Engineer-in-charge.
S&F in repair Aluminum alloy wire cloth , 0.45 mm nominal dia of wire and average width of aperture and fixed with aluminium wire staples complete all as specified and directed by Engineer-in- charge.
S&F 1000 ltrs capacity Rotational moulded polyethylene in white coloured three layered conforming to IS water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engineer-in-Charge.
Supply and fixing ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed for bore dia of pipe 20mm complete all as specified and directed by Engineer-in-charge.
S&F, CP 15mm bib taps cast copper alloy with crutch or butterfly handles, screwed down complete all as specified and directed by Engineer-in-charge.
Supply and fix CP stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends Bore of pipe in 20mm,complete all as specified and directed by Engineer-in-charge.
Supply and fix, CP stop valves, cast copper alloy 15 mm bore screwed down high pressure with crutch or butter fly handle for iron pipe or for union and complete all as specified and directed by Engineer-in-charge.
Supply and fix in repairs CP Angle stop valves of any type concealed/exposed, cast copper alloy 15 mm bore screwed down high pressure with crutch or butter fly handle for iron pipe or for union and complete all as specified and directed by Engineer-in-charge.
Supply and fix Counter top/counter sunk vitreous china wash hand basin white flat back of size 550mm X 400mm, fixed on coloured granite and fixed to wall, inlcuding of 15mm size pillar tap, cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without letter "Hot or cold'' with long scrwed shanks and fly nuts, 32mm dia brass chromium plated waste fittings 450mm long, stainless steel bottle trap and 40mm dia waste pipe complete all as specified and directed by Engineer-in-charge.
S&F PVC Connection 15mm size with PTMT nuts of length 450 mm complete all as specified and directed by Engineer-in-charge.
S&F in repair, vitreous china squatting pan "ORISSA" pattern white, of size 580x440mm with integral foot rest, CI 'P' trap etc complete all as specified and directed by Engineer-in-charge.
S&F PVC valveless syphonic action type flushing cistern low level white with inlet ball valve float and handle including brackts all as specified and directed (10 ltr capacity) complete all as specified and directed by Engineer-in-charge.
M & L granite (of any type) work 16 to 20 mm thick (table rubbed and polished) in cooking platforms and like in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 15mm of screed bed in CM 1:6.complete all as specified and directed by Engineer-in-charge.
S&F Tubular towel rail, 20 mm dia. D type, 60 cm long between flanges Brass Chromium plated complete all as specified and directed by Engineer-in-charge.
S&F Towel Ring of aluminium fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and directed by Engineer-in-charge.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed by Engineer-in-charge.
S&F Urinal partitions slabs of 15 mm thick toughned glass terminating about 40cm above floor line, fixed in repairs complete all as specified and directed by Engineer-in-charge.
S&F Glass shelf assembly fixed in repair complete all as specified and directed by Engineer-in-charge.
S&F, 100 mm dia cast iron soil waste pipe and vent pipes in any length with or without ears with cement joints laid in trenches or in floors all as specified and directed by Engr-in-charge.
M&L for 75mm dia cast iron sand cast waste and vent pipes in any length with or without ears with cement jointed fixed to wall complete all as specified and directed by Engineer-in-charge.
M&L for 100mm dia cast iron Bends complete all as specified and directed by Engineer-in-charge.
M&L for 75mm dia cast iron Bends complete all as specified and directed by Engineer-in-charge.
S&F Vitreous China Urinals, bowl type ( back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 , securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. ( Exclusive of fixing supply pipe to flushing cistern , trap and waste pipe) including CP Urinal spreader for fixing with 15mm dia pipe.(Minimum weight 60gms) complete all as specified and directed by Engineer-in-charge.
M&L for concrete bed to drain pipes for 100mm boreincluding packing under, and haunching against the sides of pipes after they are laid and complete all as specified and directed by Engineer-in-charge.
M&L for concrete bed to drain pipes for 150mm boreincluding packing under, and haunching against the sides of pipes after they are laid and complete all as specified and directed by Engineer-in-charge.
100mm bore (internal dia) salt glazed stone ware drain pipe, grade ‘A’, laid on concrete bed to required slope, jointed and tested complete all as specified and directed by Engineer-in-charge.(concrete bed shall be measured and paid for separately).
150mm bore (internal dia) salt glazed stone ware drain pipe, grade ‘A’, laid on concrete bed to required slope, jointed and tested complete all as specified and directed by Engineer-in-charge. (concrete bed shall be measured and paid for separately).
M&L pre-cast cover slab for 65mm thickness type B1 (1:2:4) using 20mm graded aggregate complete all as specified and directed by Engineer-in-charge.
M&L Cutting for 150 mm pipe into existing manhole for connecting new drain making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required complete all as specified and directed by Engineer-in-charge.
S & F PVC (SWR) floor trap 75mm size, plain with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-charge.
S&F 100 mm cast iron Traps ‘P’ or ‘S’ complete all as specified and directed by Engineer-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in soft/loose soil in layer not exceeding 25 cm thick complete all as specified and directed by Engineer-in-charge.
Removal of excavated material to a distance not exceeding 50m and deposited where directed at level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-charge.
S&F, 100 mm dia cast iron soil waste pipe and vent pipes in any length with or without ears with cement joints laid in trenches or in floors complete all as specified and directed by Engineer-in-charge.
S&F 100 mm bore dia CI bends (any radius) diminishing pieces or tapers complete all as specified and directed by Engineer-in-charge.
S&F 100mm CI branch pieces, doube (equal or unequal) ordinary or inverted (spigot or socket type) complete all as specified and directed by Engineer-in-charge.
S&F 100 mm Traps 'P' and 'S' complete all as specified and directed by Engineer-in-charge.
M&L Plain cement concrete bed 1:4:8 type D-2 (using 40mm graded crushed stone aggregates)to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150 mm bore pipe, complete all as specified and directed by Engineer-in-charge.
Supply and fix in repairs vitreous china wash hand basin counter shank with green/black granite slab to be cut and polished at site as per requirement and approved by Engineer-in-charge, fincluding brackets, 32mm bore brass chromium plated waste coupling & 32mm bore low density polythelene (LDPE) flush pipe of pressure 6Kgf/Sqcm (1.00M long,) including 15mm bore 450/600mm length PVC connection with PTMT nuts complete all as specified and directed by Engineer-in-charge. (Note : Granite shall be measured and paid seperately)
S&F in repair vitreous China wash down water closet pan (pedestal pattern), white complete, including white seat cover with hinging arrangement, (excluding fixing bolts, flushing cistern and flush pipe complete all as specified and directed by Engineer-in-charge.
S&F 10 mm thick sheet glass Urinal partitions slabs terminating about 40cm above floor line, fixed in repairs complete all as specified and directed by Engineer-in-charge.
M&L providing precast cement concrete in PCC (1:2:4) type B-1 with 20 mm graded aggregate for kerb stone and similar works with plain fair finishes including chamfers, weatherings, throat- ing etc. and setting in mortar (1:4) complete with joints to match complete all as specified and directed by Engineer-in-charge.
Dismantling Wall and ceiling boards (fibre, pulp, ACinsulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets & snap grid and complete all as specified and directed by Engineer-in-charge.
S&F for Anodised aluminium snap grid frame work for false ceiling including hangers complete all as specified and directed by Engineer-in-charge.
S&F Gypsum board false ceiling of size 600 x600 x12 cm thick for false ceiling panel or tiles for insulation and accoustic purposes, 60 cm x 60 cm in size laid/inserted to timber/GI/ Aluminium framework with screws complete all as specified and directed by Engineer-in-charge.
S&F solid PVC wall Lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC as per specification and drawing complete all as specified and directed by Engineer-in-charge.
5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed by Engineer-in-charge.
M&L pressed steel frame for doors size 125 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed by Engineer-in-charge.
M&L providing cement concrete (1:3:6) type C1 for filling in pressed steel frames and other similar items etc complete all as specified and directed by Engineer-in-charge.
S & F 35mm thick factory made shutter, plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers including 125 mm SS hinges (03 Nos),200 mm long Aluminium tower bolt (02 Nos) and 300mm long Aluminium sliding bolt (01/02 Nos) & Aluminium handles (02 Nos) each: supplied and fitted to chowkats complete all as specified and directed by Engineer-in-charge.
S & F Second class hard wood glazed and skeleton window/door shutters 35mm thick, open rebated and prepared to receive glass, gauze, etc divided into squares with plain, chamfered or rounded mitred and rebated sash bars any number & fitted with cut and mitred beads for securing glass, etc sizes of members of shutters including 125 mm SS hinges (03 Nos),200 mm long Aluminium tower bolt (02 Nos) and 300mm long Aluminium sliding bolt (01/02 Nos) & Aluminium handles (02 Nos) each: supplied and fitted to chowkats as specified in SSR Part-I, section 8 clause 8.24(a) complete all as specified and directed by Engineer-in-charge.
S&F street light timer switch i.e. nature switch which works on the basis of measurement of lux level of infra red rays along with enclosure box having dust and termite proof, outdoor type mounted on electric panel or on pole three phase with contactor, MCB rating 20 Amps with load bearing capacity of 5 KW complete all as specified and directed by Engineer-in-Charge. Make - Indo Asian Cat No TL032ASO/ Havells Cat No. IHXTSS01060A /Swadeep 02EC5KW3P
Supplying, laying, jointing and testing and commissioning of 95 sq mm, 3.5 core XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duty multi stranded aluminum conductor & PVC sheathed LT cable 1100 volts grade conforming to IS-7098 laid in trenches/ ducts/ fixed on poles/wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. Note: Excavation, earth work, sand cushioning and brick protection required for item shall be measured and paid separately complete all as specified and directed by Engineer-in-charge.
Supplying, laying, jointing and testing and commissioning of 10 sq mm, 4 core XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duty multi stranded aluminum conductor grade conforming to IS-7098 laid in trenches/ ducts/ fixed on poles/wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. Note: Excavation, earth work, sand cushioning and brick protection required for item shall be measured and paid separately.
M & L in replacement PVC insulated, PVC sheathed copper conductor electric PVC cable 1.5 Sq mm 3 Core 1100 volts grade for pole box to street light fitting complete all as specified and directed by Engineer-in-charge.
Supply and fix GI pipe 50 mm bore light grade for protection of cable including provision of clamps, nut, bolts etc required for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenches complete all as specified and directed by Engineer-in-charge.
M&L for boring of holes 50 mm under road/pavement/hard standing or any other situation by manual mean and making good both the ends complete all as specified and directed by Engineer-in-Charge. . Note : Pipe and cable will be measured and paid separately
M & L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation for poles, stays & mass concrete complete all as specified and directed by Engineer-in-charge.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in pedestal coping of poles etc including weathering, slightly rounded or chamfered angle and necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-charge.
M & L for sand cushioning with dry coarse sand to under ground cable 23 cm thick, 8 cm thick below the cable and 15 cm thick after laying the cable complete all as specified and directed by Engineer-in-charge. Note : Thickness after punning shall be considered for payment.
M & L for brick protection with old size sub class 'B' bricks laid flat , length of bricks across the route of underground cable complete all as specified and directed by Engineer-in-Charge.
S&F on pole/wall/in panel/with fabrication of stand, sheet metal enclosure, Bus bar chamber consisting 4 pole 200 Amp,including 63 Amp 4 pole MCCB, 415 volts aluminium busbar with suitable for connecting cable as a junction including connecting of cables with suitable size aluminium thimbles, cable glands including earth work and PCC complete all as specified and directed by Engineer-in-charge.
M & L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level, connecting to the Galvanised iron earth lead 32 x 6 mm size by means of bolts, nuts check nuts and washers of galvanised iron and 32 x 6 mm GI earth lead protection by provision of GI medium grade pipe 40 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with XPM (wieght not less than 4gs/Sqm) and frame of angle iron 25mm x 25mm x 6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm x 8 mm FI with fixing arrangements, funnel, wire mesh and earth work in hard dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 Mtrs all as per electrical Plate No.3 of SSR Part I and connecting to earth test point all as specified or indicated including testing on completion complete all as specified and directed by Engineer-in-charge.
S&F Rubber mat of 1 meter x 2 meter x 19 mm complete all as specified and directed by Engineer-in-charge.
Supply and fixing new generation energy saving and environmental friendly long life versatile pressure die-cast aluminum IP-66 road way luminaries 45 watt LED with high power LEDs as light source and electronic driver & incl internal surge protection device 4 KV including 25/32 mm light grade GI pipe bend (not less than 1.2 mtr long) and suitable size of MS clamp and nut and bolts etc testing complete all as specified and directed by Engineer-in-charge.
Supply and fix shock ,rust proof fire retarddant class FV-0 as per IS-11731 Part II or V-0 as per UL -94 ,high heat distortion temperature FRP juction box of size 155x210x92 mm with locking arrangement made out of 3 mm thick PVC sheet including provision of 4 nos aluminium busbar of size20 mmx3 mm/terminal box mounted on insulator 01 nos MCB 1 A SP 10 KA 240 volt , drilling holes for outgoing and incomming cable ( 2 way) connection with suitable lugs and glands including provision of clamp made out of 40 x5 mm thick mild steel flat iron complete all as specified and directed by Engineer-in-charge.
M&L for galvanized steel water tubing medium grade of 25 mm bore with & including all fittings complete, laid in trenches/wall or floor , and connections of 25 mm bore, complete all as specified and directed by Engineer-in-charge.
M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings complete, laid in trenches/wall or floor ,and connections of 20mm bore, complete all as specified and directed by Engineer-in-charge.
Supply & fixing mild steel clamps made of flat iron 40x6mm in two halves for tapping through 40 to 100mm bore GI/DI water pipe line including drilling and welding of 15-25mm GI socket and necessary rubber insertion, nut, bolts & washers complete all as specified and directed by Engineer-in-charge.
M&L for Cutting existing steel tubing for alterations or additions for 40mm to 50 mm size Screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector) complete all as specified and directed by Engineer-in-charge.
S&F 25mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, including dismantling & taking out old unserviceable gate valve of 20mm bore, complete, complete all as specified and directed by Engineer-in-charge.
M & L for concealed conduit point wiring complete for light/ fan on independent /combine board with cable 1.5 sqmm (Nominal area) FRLSH PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC Concealed conduit pipe medium grade 20 mm dia, pipe hooks , elbows, juction covers and junction boxes , after cutting in wall chasing for conduits and sinking's for modular metal flush boxes suitable length and thickness for mounting, switches, sockets,fan regulator with modular cover plate with frame and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor along with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switch and connected to common earth dolly, complete all as specified and directed by Engineer-in-charge.
All as per Srl item No -148 here in before but for one switch socket combination 5/6 amp on independent board complete all as specified and directed by Engineer-in-charge.
All as per Srl item No -148 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed by Engineer-in-charge.
All as per Srl item No. -148 here in before but for one switch socket combinationt 6 pin 5/ 15 Amps on independent board with copper conductor 2.5 Sqmm complete all as specified and directed by Engineer - in - Charge.
S & F switch piano flush type 5/6 Amps single pole one way complete all as specified and directed by Engineer - in - Charge.
S & F switch socket combination 5 pin, type 5/6 Amps flush type complete all as specified and directed by Engineer - in - Charge.
S & F switch socket combination 6 Pin, 15/16 Amps flush type complete all as specified and directed by Engineer - in - Charge.
S & F Socket outlet 5 pin 5 Amps flush type complete all as specified and directed by Engineer - in - Charge.
S & F ceiling rose surface bakelite three terminals complete all as specified and directed by Engineer - in - Charge.
S & F of T/L Fitting LED batten with aliminium housing and integrated electronic driver, 20 watt having input voltage AC90-300V, 50 Hz , 6500K, and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed by Engineer - in - Charge.
S&F security light fitting LED TYPE 25 watt with all necessary acessories, Clear transparent acrylic cover, prewire suitable to operated on 230 volt 50 HZ AC & Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 2 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer - in - Charge .
S & F Water tight bulk head fitting,comprision of connector galvanised cast iron back plate,weather proof enamelled gallery ,with LED driver and LED strip light 10 W all as specified and directed by Engineer - in - Charge .
S & F angle holder insulated body with back plate for conduit fittings complete all as specified and directed by Engineer - in - Charge.
S&F LED lamp 9W for angle holder complete all as specified and directed by Engineer - in - Charge.Make : Havells / Crompton / Bajaj
S & F in repair compact energy efficient LED mirror light fitting with antiglare diffuser and decorative end caps suitable for 1X10 watt fitting 2 ft version including LED lamp 10 watt complete all as specified.
S & F sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 4 ways, 240 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
S & F MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps , single pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
S & F MCB ‘C’ series type suitable for 240 volts, AC supply 5 to 40 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
M & L for Earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of plate not less than 1.5 Mtr below ground level , connecting to GI earth lead 4 mm dia GI earth wire ,by means of bolts,nuts and washers of GI and protection by provision of GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20 mm grade stone aggregate with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 gs /Sqmm ) and frame of angle iron 25mmX25mmX6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape ,GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed ontop edge of earth plate common salt and charcoal filling test point made out of 40 mmX 8 mm FI with fixing arrangement ,funnel, wire mesh and earth work inhard dense soil ,returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electric plate no.3 of SSR part 1 and connecting to earth test point all as specified and directed by Engr -In - Charge
S&F metal body exhaust fan of 300mm sweep, 900 RPM, 240 volt, 5 Star complete with louvers and shutter and mouted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated PVC sheasthed copper counductor flexible cable 24/0.2mm from ceiling rose to fan complete including braking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to distrubed wall in CM (1:4) white washing maching with existing door
Supply and lay jointing and testing and commissioning in replacement of 10 Sqmmx2 core XLPE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by engineer in charge.
Supply and lay standard size bricks subclass B type complete all as specified and directrd by Engineer in charge.
Supply and fix electric water heater, storage type metal body and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece fixed along walls with all fixing material required at site and electric connections with copper cable 3 core and plug top 15A includinguding making good to disturbed surface complete all as specified and directrd by Engineer in charge.
Supply and fix electric water heater, storage type metal body and heating element upto 2 KW capacity 50 litre, BEE 4 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece fixed along walls with all fixing material required at site and electric connections with copper cable 3 core and plug top 15A includinguding making good to disturbed surface complete all as specified and directrd by Engineer in charge.
S & F gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for GI pipes of size 15 mm bore complete all as specified and directrd by Engineer in charge.
M&L for concealed point wiring complete on independent /combined board with cable 2.5 Sqmm (nominal area) FRLSH, PVC insulated multi stranded unsheathed copper conductor including conduit fittings after chasing in wall and making good the disturbed surfaces include sunken iron box, 3 mm thick bakelite sheet cover , pipe hooks elbows, brass screws washers with provision of earth continuity conductor of 2.5 sqmm copper single core PVC FRLSH insulated cable controlledbyone switch andconnected to common earth dolly for one socket outlet 3 pin 15 amps complete all as specified and directed by Engineer-in-charge.
S & F of sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLSH stranded copper conductor drawn in concealed PVC conduict dia 25mm “medium quality” conduit including 6.00 Sq mm (Nominal Area) copper cable as earth continuity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and covers including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer - in - Charge. (Note : PVC cable and PVC conduit shall be ISI marked)
S & F RCCB cap 25 Amps with sensivity 30 mA, double pole in accordance with IS 12640-1 & IEC 61008-1) 240/415, 50Hz with 10kA short circuit, AC type, withstand capacity including enclosure and other accessories complete all as specified and directed by Engineer - in - Charge. Note : - RCCB should be fixed in DB with connection of geyser circuit
S&F adjustable Brass chromium plated shower rose size upto 125mm or as per reqmt of existing site with shower arm all as specified and directed by Engr -in-Charge.
S&F Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed as specified and directed by Engr-in-Charge.
S&F Supply electing true vertical position 9 meter long, type 410 SP-31 tubular swan necked pole complete with cast iron base plate, finial taper, plug, bolts nuts and screws including painting with two coat of synthetic enamel paint black and white in alternate strips 30cm each upto 1.5 meter height from top of PCC coping and remaing protion of pole shall be painted with two coats of aluminium paint including writing pole No, with black synthetic enamel paint over 15cm dia, yellow round base prepared with synthetic enamel paint complete all as specified and directed by Engr-in-Charge. Note : Excavation, earth work and concrete work for embedding poles shall be measured and paid seprately.
S&F Supply and install air cooled split unitair conditioner indoor and outdoor complete with cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor quality with 5 Star rating, electric driven, 230 volts AC, 50 Hz Dual inverter, copper condenser with complete accessories of capcity 1.5 TR complete all as specified and directed by Engr-in-Charge.
M&L for sub main wiring with 2 runs of 4 sqmm single core, PVC insulated & unsheathed cable 1100 Volts grade with multi stranded, copper conductor drawn through concealed conduit including PVC rigid conduit medium grade as per ISS and onr run of 4 sqmm size PVC insulated copper conductor including cutting chasies as required & taking down old submain and making good surface complete all as specified and directed by Engr-in-Charge. (Note : Two run of cable and earth conductor shall be measured as one length)
Supply and fixing industrial wall mounted plug socket with 20 Amp MCB complete all as specified and directed by Engr-in-Charge.
Suppy and fixing LED bldg security light fitting 1x30 Watt flame proof, CMRI certified recommended for gas/vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with dia cast aluminium housing with heat resistannt toughened glass, with LED light fixtures driver, holders, connector etc. Complete with all accessories prewired and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35mm bore "light grade" brackets 2 mtr length bent to shape to obtained required shape including clamps, nuts/ bolts / washers etc complete all as specified and directed by Engr-in-Charge.
S & F in repair sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 8 ways, 240 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
S & F in repairs MCB 'C' series type suitable for 240 volts, AC supply 32 Amps SP & N with over load and short circuit protection and rupturing capacity not less than 10 KA complete all as specified and directed by Engineer - in - Charge.
S & F in repairs MCB 'C' series type suitable for 240 volts, AC supply 5 to 32 Amps single pole with over load and short circuit protection and rupturing capacity not less than 10 KA complete all as specified and directed by Engineer - in - Charge.
Note :(i) Amount of credit for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline.
PAREEK AND COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .