Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹10.0 L+₹87,425.34 (9.58%)Rejected-Finance 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L2 | Rejected-Finance Other than L1. | |
| 3 | L3₹10.0 L+₹87,599 (9.60%)Rejected-Finance | L3 | Rejected-Finance Other than L1. | |
| 4 | L4₹13.5 L+₹4.3 L (47.6%)Rejected-Finance | L4 | Rejected-Finance Other than L1. |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
14 Mar 2023, 6:00 pmClosed
GE (AF) BHISIANA
GE (AF) BHISIANA PIN-151201
AS PER BOQ/PRICE SCHEDULE
2023_MES_580973_1
GE/BHI/MW/2022-23
Open Tender
Civil Works
Item Rate
60 days
GE (AF) BHISIANA
AS PER NIT/TENDER DOCUMENT
6 documents required · 6 mandatory
₹500
GE (AF) BHISIANA
₹20,000
Yes
5 Apr 2023
15 Feb 2023
16 Mar 2023
15 Feb 2023
14 Mar 2023
1 Mar 2023
20 Feb 2023 - 24 Feb 2023
Amount
MW/04/2022-23 AT AF STN FEROZEPUR (B/R WORKS)
Excavation in post holes each not exc 0.5 cum getting out returning filling in and removing earth or broken rubble mixed with earth around in layers not exc 25 cm watering and removing surplus soil to a distance not exc 50m and making good surface as in soft /loose soil complete all as specified and directed by Engineer in Charge.
M&L Cement Concrete 1:3:6 type C-2 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ordered, complete all as specified and directed by Engineer in Charge.
S&F of Mild Steel compound girders and stachions ,lattice girders aerial masts, staging for water tanks and the like including caps bases splices etc built up from two or more beam or channel sections or angles with plates including all lattice bars, stiffners, guesset plates etc conforming to Fe.290.Gde-E-165, complete all as specified and directed by Engineer in Charge.
S&F roof trusses (framed) , trussed purlins crane gantries rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces cleats etc. conforming to Fe.290.Gde-E-165, complete all as specified and directed by Engineer in Charge.
S&F Pre-painted galvulume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws complete all as specified and directed by Engineer in Charge.
S&F Pre-painted galvulume aluminium zinc coating GI based plain steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws as specifed complete all as specified and directed by Engineer in Charge.
M&L preparing New or previously untreated Steel and Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a Red Oxide Zinc Chrome Primer, complete all as specified and directed by Engineer in Charge.
M&L Brick Work with Sub-Class ‘B’ Bricks (Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and directed by Engineer in Charge.
M&L Rendering 15mm thick in Cement Mortar 1:6 on Brick Walls or on Concrete Surfaces ,un Plastered Surfaces finished Even and fair without using Extra Cement, complete all as specified and directed by Engineer in Charge.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint on walls, pillars cornices complete all as specified and as directed.
M&L Cement Concrete 1:3:6 type C-2 (40mm graded stone aggregate) 75mm thick in Fillings, Sub-base to Floors, etc. complete all as specified and as directed.
M&L Cement Concrete 1:2:4 type B-1 (20mm graded stone aggregate), 40mm thick in Flooring ,etc finishing Cement Concrete Surfaces Even and Rough without using Extra Cement, complete all as specified and as directed.
M&L for Forming construction (Dummy) joints 100 mm deep and 10 mm wide, filled with grade 'A' sealing compound, complete all as specified and as directed.
M&L for Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out soft /loose soil, complete all as specified and as directed.
M&L for hard core of guage not exc 63mm deposited spread and level laid in layers n.exc 15cm thick, watered and rammed to a true surface of broken boulders, complete all as specified and as directed.
M&L for PCC (1:4:8) type C-2 using 40mm graded agg as in sub base of floor 100mm thick, complete all as specified and as directed.
S&F of chequered cement concrete tiles 30cm x 30cm x 25mm thick, set ,jointed and pointed in neat cement slurry in floors.(with grey cement and pigments) laid over and including 15mm th bedding layer in CM 1:4 complete all as specified.
MW/04/2022-23 AT AF STN BHISIANA (B/R & E/M WORKS)
Demolition of reinforcement Cement Concrete of Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work and removal of debries from MD land complete all as specified and directed by Engineer in Charge.
Dismantling Stone slabs and tiles of any description or thickness laid bedded & pointed in any mortar in floors/walls, aprons complete all as specified and directed by Engineer in Charge.
Demolition of brick or stone boulder masnory, built in Cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facing, dressed stonework and percast concrete articles complete all as specified and directed by Engineer in Charge.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m deep in hard/dense soil complete all as specified and directed by Engineer in Charge.
M&L for Cement Concrete 1:4:8 type D-2 (using 40 mm graded stone agg) as in foundation complete all as specified and directed by Engineer in Charge.
M&L Cement concrete M-25 desigh mix (using 20mm graded aggregate) for foundations, including rafts, footings, foundations beams, plinth beams, bases for columns etc complete all as specified and directed by Engineer-in-Charge.
M&L Cement concrete M-25 desigh mix (using 20mm graded aggregate) for columns, pillars, piers, post and strut complete all as specified and directed by Engineer-in-Charge.
M&L Cement concrete M-25 desigh mix (using 20mm graded aggregate) for beams, cantilivers, beressummers, lintels over 1.5m span complete all as specified and directed by Engineer-in-Charge.
M & L Cement concrete M-25 desigh mix (using 20mm graded aggregate) for Slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves, complete all as specified and directed by Engineer-in-Charge.
M&L for formwork to sides of concrete , foundations, footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work for rough finished surface complete all as specified and directed by Engineer-in-Charge.
M&L for formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantiliver shelves etc.for fair finished complete all as specified and directed by Engineer-in-Charge.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete raillings , opening in concrete walls, floors and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, hozontal or sloping and similar work exc 5cm but n exc 10cm etc.for fair finished surface complete all as specified and directed by Engineer-in-Charge.
M&L for Formwork to soffits of suspended slabs flat such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engineer-in-Charge.
M&L for Mild steel TMT bars 10mm dia and over , cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns,footing, plinth beam, roof beam, lintels, slabs and other similar structures etc., hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc complete all as specified and directed by Engineer-in-Charge
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for 40mm thick damp proof course in cement Mortar 1:2 to horizontal or vertical surfaces including necessary formwork complete all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick Cement plaster in CM (1:6) on fair faces of brick or concrete surfaces and finishing the surface even and fair (without using extra Cement) etc including applying two coats oil bound distemper (OBD) over a coat of primer and after preparation of plastered surfaces complete all as specified and directed by Engineer-in-Charge.
M&L rendering 15mm thick on Cement mortar 1:4 finished fair faces of brick/concrete surfaces even and fair without using extra Cement complete all as specified and directed by Engineer-in-Charge.
M&L for newly plastered surface of walls including corners and applying two coats of 100% Premium exterior acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm complete all as specified and directed by Engineer-in-Charge.
M&L for 5 mm thick Cement plaster 1:3 on fair faces of brick work or concrete surfaces in ceiling and finishing the surface even and smooth (without using extra Cement) etc including applying three coats of white wash and after preparation of plastered surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick Cement concrete type D-2, 1:4:8 (40 mm graded stone aggregate) as in sub base complete all as specified and directed by Engineer-in-Charge.
M&L for Non skid coloured ceramic tiles/Rectified tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat Cement slurry and pointed in white or coloured Cement to match including 15mm thick screed bed in CM (1:4) for laying floor finishes complete all as specified and directed by Engineer-in-Charge.
M&L for Non skid coloured ceramic tiles/Rectified tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm on vertical surfaces as in skirting set and jointed in neat Cement slurry and pointed in white or coloured Cement to match complete all as specified and directed by Engineer-in-Charge.
M&L for granite 18-20mm thick of any type ( table rubbed and polished in steps, jambs pillars, window cill, cooking platform and like in Cement mortar 1:4 incl pointing in white Cement complete all as specified and directed.
S&F for Anodised aluminium frame for doors, windows ventilators (Powder Coated) with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer-in-Charge.
M&L Anodised aluminium door shutters (powder coated), aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed by Engineer-in-Charge.
M&L Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed by Engineer-in-Charge.
M&L sheet glass ordinary quality 5.5mm thick and glazing with oil putty or fixed with bead/ glazing pins in squares n.exc 0.5 sqm each pane all corner of glass to be fixed with silicon complete all as specified and directed by Engr-in-Charge.
M&L for Non asbestos fibre Cement boards 595x595x4mm thick fixed in ceiling Aluminium frame work with screws complete all as specified and directed by Engineer-in-Charge.
S&F Anodised aluminium snap grid frame work of grid 600x600mm for false ceiling including 4mm dia wire for anchoring with frame work complete all as specified and directed by Engineer-in-Charge.
S&F framed work such as grills,gratings,portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc, with ends of bars shoulderedor riveted, or forged into spikes; framed guard bars;barred iron doors and similar work conforming to Fe 210,Gde E-165 complete all as specified and as directed by the Engineer-in-Charge.
M&L for Two coat of synthetic enamel paint over a coat of primer red oxide including preparation on new steel surfaces of any description over 10 cm width or girth complete all as specified and directed by Engineer-in-Charge.
Taking down Copper/Aluminium Point Wiring any type in PVC casing caping /PVC Conduit (Light, Fan, Socket or Power) excluding Fixture and Fittings such as Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fittings of any description and Making Good Disturbed Surfaces of Walls, Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed by Engineer in Charge.
Taking down/out unserviceable main switches and DB's including MCBs of any size / type and of any description and Making Good Disturbed Surfaces of Walls, Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed by Engineer in Charge.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn through and including Rigid Non-metallic PVC Conduit 19mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing PVC Gang Box (minimum 2.0mm thick)/Sunk Mild Steel Pressed Terminal Box (1.6mm thick) of suitable size duly painted with Red Oxide Metal Primer with 3.0mm thick Plastic Laminated Sheet Top Cover (as per Site requirement) for mounting Switches, Sockets, Fan Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/FAN POINT/ BELL POINT CONTROLLED BY ONE 1-WAY SWITCH 6 AMP, complete all as specified and as directed by Engineer in Charge.
All as per Item No 2.30 for One 3 Pin Switch socket Combination 6 amp on the independent board, complete all as specified and as directed by Engineer in Charge.
All as per Item No 2.30 for One 3 Pin swich socket Combination 6 amp on the same board with other switches, complete all as specified and as directed by Engineer in Charge.
M&L Concealed Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Cable, drawn through and including Rigid Non-metallic PVC Conduit 19mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing PVC Gang Box (minimum 2.0mm thick)/Sunk Mild Steel Pressed Terminal Box (1.6mm thick) of suitable size duly painted with Red Oxide Metal Primer with 3.0mm thick Plastic Laminated Sheet Top Cover (as per Site requirement) for mounting Switches, Sockets, Fan Regulators, etc. Earth Continuity Cable connected to Common Earth dolly for ONE MULTI PURPOSE SOCKET 16 AMP ON INDEPENDENT BOARD, complete all as specified and as directed.
S&F Switch Piano 6 Amp, Flush type, Single Pole, 1-way and , complete all as specified and as directed by Engineer in Charge.
S&F Switch Piano 16 Amp, Flush type, Single Pole, 1-way, complete all as specified and as directed by Engineer in Charge.
S&F Socket Outlet 6 Amp, Piano, Flush type, 2-in-1, multi-purpose, 5 Pin, complete all as specified and as directed by Engineer in Charge.
S&F Socket Outlet 6 Amp & 16 Amp, Piano, Flush type, 2-in-1, multi-purpose, 6 Pin, complete all as specified and as directed by Engineer in Charge.
S&F Fan Regulator in 5 Step type, Single Pole, 230 Volt, Electronic type, complete all as specified and as directed by Engineer in Charge.
S&F Ceiling Rose, 3 Terminals, PVC Polycarbonate, Isolated body and complete all as specified and as directed by Engineer in Charge.
S&F MCB DB SPN 2 Way Factory Made IP 43 Protection metal double door with 200 Amp rating Bus Bar 240V for fixing of MCBs/Isolators/RCCBs etc , complete all as specified and as directed by Engineer in Charge.
S&F MCB Single Pole Neutral 40 to 63 Amp, 240 /415 Volt, AC, 'C' Series for fixing on MCB DB’s, 10 kA, 50 Hz , 35mm2 Terminal Capacity insulated sliding shutter including Connecting up and Fixing in DB of any make/ type, complete all as specified and as directed by Engineer in Charge.
S&F 1X18 watt incl taking down wall mounted, new generation LED T-8 Retro fit for multipurpose application with LED Rod, made from exturded aluminium housing, polycarbonate diffuser including all fixing accessories & connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge.
MW/05/2022-23 AT AF STN BHISIANA (B/R & E/M WORKS)
Cutting holes in brick walls in mud mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required Depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall Exc. One brick but not Exc. two Brick, complete all as specified and directed by Engineer in Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed by Engineer in Charge.
M&L for PCC type B-2, 1:2:4 (using 40mm graded stone aggregate) for foundation filling, mass concrete and etc complete all as specified and as directed.Cement concrete in foundations, filling and mass concrete, complete all as specified and directed by Engineer in Charge.
S&F Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.45mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer in Charge.
S&F for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated Fe 410-W(Gde-E- 250) quality complete all as specified and directed by Engineer in Charge.
S&F for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) i indicated Fe 410-W(Gde-E- 250) quality complete all as specified and directed by Engineer in Charge.
M&L for cement conctere 100mm thick type B-2, 1:4:8 (40mm graded aggregate), finishing cement concrete complete all as specified and directed by Engineer in Charge.
M&L for Cement concrete chequred tiles with grey cement & pigment 300 x300x25 mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, over cement screed bed of mortar 15mm thick in CM 1:6 complete all as specified and directed by Engineer in Charge.
M&L for two coat of synthetic enamel paint over a coat of primer including preparation on new steel surfaces of any description over 10 cm width or girth complete all as specified and directed by Engineer in Charge.
S&F Mild steel screw bolts 5 to 10 mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed by Engineer in Charge.
MW/06/2022-23 AT AF STN BHISIANA (E/M WORKS)
M/s Luxmi Constructions
STELLAR PROJECTS
GUPTA AND ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .