| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.4 CrAdmitted-Finance | -0.01% | ₹3.4 Cr | L1 | Admitted-Finance |
Tender Value
₹3.4 Cr
EMD Value
₹6.7 L
Closing Date
16 Feb 2026, 6:00 pmClosed
ADDITIONAL CHIEF ENGINEER
GANDHI NAGAR JAIPUR
Reorganisation Of RWSS Of Village Nayan And 25 Dhani Habitation In Gram Panchyat Nayan For Providing FHTC Under JJM
2026_PHCJA_528956_2
NIT NO-19 To 20/2025-26/ACE PHED REGION-II/JAIPUR
Open Tender
Civil Works - Water Works
Percentage
270 days
JAIPUR
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
EE PHED DIV SHAHPURA/MD RISL
₹6.7 L
Yes
ACE PHED REGION II JAIPUR
7 May 2026
17 Jan 2026
17 Feb 2026
17 Jan 2026
16 Feb 2026
30 Jan 2026
27 Jan 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Construction of Tubewell | - | - | - | - |
| - | Construction of tube well from ground level & up to 100 mtr depth to accommodate housing and assembly pipe of following sizes in all type of alluvium strata unconsolidated formation such as pebbles, boulders etc. by percussion/rotary drilling method as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications, with gravel as per IS:4097-1967 and it's packing as per IS: 2800 (Part I & II) 1979 as amended up to date (the work includes the cost of gravel & it's primary packing and packing during development, lowering of housing & strainer assembly pipes with supply and wrapping of coir-rope, wherever necessary for arresting fine sand particles and development work, but excluding the cost of housing and strainer pipe assembly). The work would be completed after obtaining sand free water.
Nominal bore 200 mm dia. | 400 | Rmt. | 1,523 | ₹6,09,200 |
| - | Construction of tube well after completion of drilling by rotary /percussion method & up to 100 mtr. depth in all type of rocks by DTH system as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work shall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe.
Nominal bore 200 mm dia. | 850 | Rmt. | 1,263 | ₹10,73,550 |
| - | Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) | 405 | Rmt. | 2,734 | ₹11,07,270 |
| - | Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985.
200 mm dia nominal bore of 5.4mm thickness | 90 | RM | 317 | ₹28,530 |
| - | Supply & Fixing M S clamp set of 50x6 mm flat from
iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. | 5 | Each | 696 | ₹3,480 |
| - | Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug.
200 mm dia | 5 | Nos. | 986 | ₹4,930 |
| - | Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.
9.3KW (12.5 HP) & head above 120 mtr. | 46.5 | KW | 7,552 | ₹3,51,168 |
| - | Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes
80 mm dia | 5 | Nos. | 2,830 | ₹14,150 |
| - | Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge.
Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
a) 80 mm | 5 | Nos. | 6,301 | ₹31,505 |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.93 MB
BOQ_943486.xls
BOQ • 0.53 MB
TD-20.pdf
Tender Documents • 13.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .