AGM (E-E)-II
Airports Authority of India, Imphal International Airport.
Provision of energy efficient split type Airconditioners and water cooler for various locations in place of old ACs at Imphal International Airport
2019_AAI_37485_1
AAI/IMP/AGMEE/eNIT-CW-13/19-20
Open Tender
Electrical Works
Item Rate
120 days
Imphal
As per NIT
3 documents required · 3 mandatory
₹1,120
Airports Authority of India
₹35,144
3 Feb 2020
5 Dec 2019
7 Jan 2020
6 Dec 2019
1 Jan 2020
6 Dec 2019
6 Dec 2019 - 27 Dec 2019
Amount
Supply of 2 TR, highwall split A/Cs, 5 star rating, Inverter Split Units with R410a Gas. (Both indoor and outdoor units), complete with filters, cooling coils connected to condensing units, including remote control operation for temparature adjustment, indoor unit blower speed, swing adjustment, auto restart, sleep mode turbo mode, with LED display for temparature i/c standard length of copper refrigerant pipe, copper electrical cable & drain pipe etc., complete as required.
Supply of 1.5 TR, highwall split A/Cs, 5 star rating, Inverter Split Units with R410a Gas. (Both indoor and outdoor units), complete with filters, cooling coils connected to condensing units, including remote control operation for temparature adjustment, indoor unit blower speed, swing adjustment, auto restart, sleep mode turbo mode, with LED display for temparature i/c standard length of copper refrigerant pipe, copper electrical cable & drain pipe etc., complete as required.
Installation testing and Commissioning of 2.0 TR high wall Split Acs ( Invertor Type) Unit etc and making of necessary hole on concrete wall and making good the damages i/c providing suitable size PVC pipe for drawing the /drain pipe and wire etc through the concrete/brick wall as required.
Installation testing and Commissioning of 1.5 TR high wall Split Acs (Invertor Type) Unit etc and making of necessary hole on concrete wall and making good the damages i/c providing suitable size PVC pipe for drawing the /drain pipe and wire etc through the concrete/brick wall as required.
Supply, installation, testing and commissioning of extra refrigent copper pipe suitable for 2 TR and 1.5 TR inverter type AC including leakage testing and provining fixing of insulation, soldering, necessary clamping arrangement etc. Of follwing size as required. 3/4"
Supply, installation, testing and commissioning of extra refrigent copper pipe suitable for 2 TR and 1.5 TR inverter type AC including leakage testing and provining fixing of insulation, soldering, necessary clamping arrangement etc. Of follwing size as required. 3/8" Dia.
Supply, installation, testing and commissioning of stranded copper cable size 4 core x 1.5 sq.mm between indoor and outdoor units.
Supply, installation, testing and commissioning of extra UPVC pipes size 32 mm dia. complete with fittings and 'U' traps for Condensate Drain Piping with supports and thermal insulation as per specifications.
Supply, installation, testing and commissioning of MS frame stand (if required) for fixing outdoor units of 2 TR & 1.5 TR split AC complete as required.
Wiring for light / power plug with 2 x 4 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit alongwith 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as requried.
Supply, installation, testing and commissioning of 20 ampere Modular Socket Box with inbuilt 20 ampere SP, C Curve Mini MCB, Plastic enclosure & unbreakable Heavy duty with ISI marke plug top and necessary connection i/c dismantling of existing power plug if necessary complete as required.
Dismantling of existing 2 TR Ac and transportation of dismantled items upto dismantle store complete as required.
Dismantling of existing 3 TR Ac and transportation of dismantled items upto dismantle store complete as required.
Dismantling of existing 60/80 Ltr water cooler and transportation of dismantled items upto dismantle store complete as required.
Supply, installation, testing and commissioning of heavy duty storage water cooler cum purifier with seven stage filter. Storage capacity (Upto float valve level) - 80 ltr, for operation on single phase AC supply and cooling capacity of 40LPH complete etc. as per technical specification. (Make: Bluestar, Voltas, Eureka Forbes)
Supply, fixing, testing and commisioning of wall mounting type automatic electricnic volatge stablizer suitable for 1.5 TR split Air conditioners having capacity 4 KVA single phase an auto volatge range of 180- 270 V with high/low voltage cut off on delay etc complete as required. (Make: V-Guard, Microtek, APC)
Supply, fixing, testing and commisioning of wall mounting type automatic electricnic volatge stablizer suitable for 2.0 TR split Air conditioners having capacity 5 KVA single phase an auto volatge range of 180- 270 V with high/low voltage cut off on delay etc complete as required. (Make: V-Guard, Microtek, APC)
RS COOLING APPLIANCES
star refrigeration sales and service
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .