Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 LAdmitted-Finance 508 C WING SRA BUILDING NO 6C OPP DURGA MANDIR MALAD EAST MUMBAI 400 097 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | ₹9.3 L | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | V S Engineering L1 |
|---|---|---|---|---|
| 1.00Supply, installation, testing and commissioning of Ceiling suspended Air-cooled Ductable unit each comprising an air cooled condenser with Superhydrophobic coating, Hermetically sealed compressor, condenser fan, Cooling thermostat with wiring etc. with outer casing and indoor unit consisting of DIDW forward curve Blower, fan motor DX cooling coil 3 row deep or as per manufacturer std with Copper tubes shall of minimum 0.25 mm thickness, nominal dia minimum 7 mm and Aluminium fins 13-18 fin/finch, thickness minimum 0.105 mm with Superhydrophobic coating, outer casing, filter, control and power panel with remote, Silicon Based Fire retardant canvass connection etc. Necessary Power Cabling and earthing from incomer to AC units, first fill of refrigerant and oil, supports, canvas connection etc. The indoor and outdoor units shall be with structural steel supports, angles, rods etc. The unit capacities shall be after taking deration into account due to copper piping lengths. Fins and copper tubes of Air Cooled Condenser along with copper tubing/ piping with all joints and U-Bends exposed to atmosphere/ aggressive ambient, shall be painted with special Corrosion prevention coating either in factory or at site. R-410a refrigerant shall be provided. DX Coil- 3 row deep or as per manufacturer std intertwined DX condensing coils with Copper tubes shall of minimum 0.25 mm thickness, nominal dia minimum 7 mm and Aluminium fins 16- 18 fin./inch, thickness minimum 0.105mm, Coil size shall be selected for air velocity of 350 ft/minute & velocity across filters at 350 ft/minute. The quoted price shall also include supports, clamps, fittings, connections, sleeves, supports, MCB, power cabling etc from main panel to the unit. Housekeeping and Disposing all type of generated debris and scrap out of TMH is deemed to be included in this item cost. Make: Trane, Mitsubishi, Daikin | ||||
| 1.01 | 4Tr Aircooled ductable Air Conditioner (CT scan server roon near Service building) | 2 | Nos | 1,35,000 ₹2.7 L |
| 2.00Supply, installation, testing and commissioning including vaccumization and Nitrogen testing of following nominal size 18G copper refrigerant piping for package/ Ductable AC system, complete with fittings with suitable supports, jointing/ brazing including accessories. | ||||
| 2.01 | Suction line- 5/8 & Liquid line- 1/2 or as per OEM recommended refrigerent copper piping with nitrile rubber insulation sleeve. | 15 | Rmt | 2,000 ₹30,000 |
| 3.00Supply, installation, balancing and commissioning of factory fabricated GSS sheet ducting with Companion flange joints girth angle and MS angle of 50 mm x 3 mm. Metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, G.I. hangers, G.I. Angle supports etc. as per approved drawings and as per specifications of following sheet thickness complete as required. Make- Jindal / Sail / Tata | ||||
| 3.01 | 22Gauge GI ducting | 20 | SQM | 1,500 ₹30,000 |
| 4.00 | SITC of 25 mm thick thermal Insulation with Closed Cell Elastomeric Nitrile Rubber with Density 40 to 55KG & Thermal conductivity shall not exceed 0.035 W/(m. K) at mean temperature of 0C as per EN 12667.Covering material shall be of multiple layered laminate of polymeric material reinforced with scrim with a special UV protection with Black colour. Mat FINISH, 380 ± 20 GSM as per ASTM D 646. &ASTM E 252 and have good UV resistance as per ISO 4892-2 Method A tested for 1000 Hrs, the tensile strength of >5 MPa in MD & CD as per ASTM D 638 – All INSULATION SHALL BE WETTED WITH MANUFACTURER. Exposed Joints to be seal with recommended sealant. Make - Armaflex/Vidoflex/Fireflex/ALP | 20 | Sqm. | 1,500 ₹30,000 |
| 5.00 | Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc as per specifications. Make- Dynacraft, Cosmos, System Air, Trox | 3 | SQM | 10,000 ₹30,000 |
| 6.00 | Supply, fixing, testing and commissioning of supply air diffuser of powder coated AL with AL volume control damper with anti smudge ring & removable core.
Make- Dynacraft, Cosmos, Systemair, Trox | 2 | SQM | 13,000 ₹26,000 |
| 7.00 | Supply, fixing, testing and commissioning of Return air diffuser of powder coated AL without AL volume control damper with anti smudge ring & removable core.
Make- Dynacraft, Cosmos, Systemair, Trox | 2 | SQM | 11,500 ₹23,000 |
Updated dates
Tender Value
₹12.1 L
EMD Value
₹24,220
Closing Date
1 Apr 2026, 6:55 pmClosed
OIC, Engineering, TMC on behalf of Director, TMC
Engineering Department, 6th Floor, Service Block, TMH, Parel
Proposed site preparation work for CT Scanner Machine at Basement Main Building - HVAC (Mechanical) Works
2026_TMC_902024_1
TMC/ENG/CTScan/HVAC/25-26/57
Open Tender
Machineries/ Mechanical Engg Items
60 days
TMH, Parel
As per tender document
6 documents required · 6 mandatory
₹0
₹24,220
TMH, Parel
7 May 2026
12 Mar 2026
3 Apr 2026
12 Mar 2026
1 Apr 2026
20 Mar 2026
12 Mar 2026 - 16 Mar 2026
17 Mar 2026
Contact person
Average last 3 consecutive years
M/s. Company Name WO No. / LOI No / Agreement No. dated Subject Amount Rs. (Location of site)
M/s. Company Name WO No. / LOI No / Agreement No. dated Subject Amount Rs. (Location of site)
M/s. Company Name WO No. / LOI No / Agreement No. dated Subject Amount Rs. (Location of site)
Item Rate BoQ
BoQ_Ver3.0
NIT No. TMC/ENG/CT/Scanner/HVAC/2025-26/e-NIT/57 dated 12/03/2026
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.84 MB
scopeofwork.pdf
Tender Documents • 0.16 MB
techdocumentchecklist.xls
Tender Documents • 0.03 MB
BOQ_948122.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid