Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.2 LAccepted-AOC | ₹49.2 L Quoted ₹49.4 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹53.9 LRejected-Finance | ₹53.9 L | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹54.0 LRejected-Finance | ₹54.0 L | L3 | Rejected-Finance Not being lowest |
| Sl No | Description | Qty | Unit | Mighty Steel Sales Crop L1 | Auto Traders L2 | Vinayak Trading House L3 |
|---|---|---|---|---|---|---|
| 1.00 | M&L Modular Brick work with Fly Ash bricks straight or curved on plan exc 6m mean radius built in CM 1:6 incl demolition of old brick work or stone/ boulder masonary built in cement mortar including all quions, arches, pillars, etc complete all as specified and directed. Note :- For further details wrt to specifications & terms and conditions for this item pl refer MES SSR Pt-I (2009) & SSR Pt-II (2020) & contractors quoted rate shall be deemed to be inclusive of the same. | 0.5 | Cum | 7,500 ₹3,750 | 4,900 ₹2,450 | 5,950 ₹2,975 |
| 2.00 | Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water and rendering 5 mm thick in cement mortar 1:3 on concrete surfaces of ceiling and finishing the surfaces even and smooth complete all as specified and as directed. Note :- For further details wrt to specifications & terms and conditions for this item pl refer MES SSR Pt-I (2009) & SSR Pt-II (2020) & contractors quoted rate shall be deemed to be inclusive of the same. | 115 | Sqm | 280 ₹32,200 | 185 ₹21,275 | 150 ₹17,250 |
| 3.00 | M&L Rendering on fair faces of brick work or concrete surfaces of wall 15 mm thick in CM 1:6 and to be finished even and smooth without using extra cement complete all as specified and directed. Note :- For further details wrt to specifications & terms and conditions for this item pl refer MES SSR Pt-I (2009) & SSR Pt-II (2020) & contractors quoted rate shall be deemed to be inclusive of the same. | 5 | Sqm | 300 ₹1,500 | 230 ₹1,150 | 310 ₹1,550 |
| 4.00 | M&L for 10 mm thick Light shade vitrified ceramic tiles in floors, not exceeding 0.36 sqm, set & jointed in neat cement slurry and pointed in coloured cement to matching with adjacent tiles with screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 for laying of floor tiles including dismantling of old floor tiles including bedding (but not backing), and rubbish off permises complete all as specified and directed. (Note : The rates include for all straight cutting and waste.) | 43 | Sqm | 1,500 ₹64,500 | 900 ₹38,700 | 1,250 ₹53,750 |
| 5.00 | M&L for 10mm thick Light shade vitrified ceramic tiles in skirtings/ vertical surfaces, not exceeding 0.36 sqm, set & jointed in neat cement slurry and pointed in coloured cement to match with rendering 10 mm thick in cement mortar 1 : 4 for fixing of wall tiles including dismantling of old wall/dado tiles including bedding (but not backing), and rubbish off permises complete all as specified and directed. (Note : The rates include for all straight cutting and waste.) | 4.06 | Sqm | 2,000 ₹8,120 | 920 ₹3,735.20 | 1,500 ₹6,090 |
| 6.00 | M&L for 16 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl dismantling and rubbish off premises or removed to store complete all as specified and directed. | 1 | Sqm | 6,000 ₹6,000 | 2,800 ₹2,800 | 4,500 ₹4,500 |
| 7.00 | Providing & fixing False ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling with semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles of size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225 : 1987, Noncombustible as per BS tiles 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15 x 32 mm of length 3000mm, cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws incl dismantling of old False Ceiling. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. Note : The rates include for:
(a) Use of all scaffoldings and cradles including hoisting and lowering. (b) Shifting of movable cupboards and furniture as required and replacing in position. | 462 | Sqm | 1,250 ₹5.8 L | 1,325 ₹6.1 L | 1,500 ₹6.9 L |
| 8.00 | M&L for Providing and fixing perforated Gypsum Board 12 mm thick on walls fixed with screw as per manufacturers instructions incl dismantling of old False Ceiling complete all as specified and directed. Note : The rates include for:
(a) Use of all scaffoldings and cradles including hoisting and lowering. (b) Shifting of movable cupboards and furniture as required and replacing in position. | 20 | Sqm | 600 ₹12,000 | 1,300 ₹26,000 | 610 ₹12,200 |
| 9.00 | S&F in repairs for Anodised aluminium frame for doors, windows, ventilators with one or more rebates, channels, flanges, tees etc including joining cleat for fixing etc complete all as specified and directed. | 10 | Kg | 700 ₹7,000 | 500 ₹5,000 | 710 ₹7,100 |
| 10.00 | S&F Mild steel framed works such as grills,gratings,etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; framed balusters; walk ways; railings; framework of water tanks and similar work for portions framed and hung as gates, including pintle hinges, stops, hand made sliding bolts, etc conforming to Fe 290 Gde -E-165 incl dismantling wrought iron or mild steel work of any description complete all as specified and directed. (Note :-The rates include for riveting and/or welding as directed and fixing with screws, bolts, etc. complete) | 20.1 | Kg | 150 ₹3,015 | 130 ₹2,613 | 135 ₹2,713.50 |
Updated dates
Tender Value
₹48.1 L
EMD Value
₹96,200
Closing Date
28 Apr 2026, 6:00 pmClosed
GE (AWC) Mhow
GE (AWC) Mhow
SPL REPAIRS OF REPLACEMENT OF AC SYSTEM OF HUB WITH VRF AC AGAINST BER AC AWC UNDER GE (AWC) MHOW
2026_MES_755829_1
8928/(AWC)/MHOW/ OF 2025-26
Open Tender
Electrical and Maintenance Works
180 days
GE (AWC) Mhow
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AWC) Mhow
₹96,200
15 Jun 2026
11 Mar 2026
30 Apr 2026
11 Mar 2026
28 Apr 2026
9 Apr 2026
M&L for 10 mm thick Light shade vitrified ceramic tiles in floors, not exceeding 0.36 sqm, set & jointed in neat cement slurry and pointed in coloured cement to matching with adjacent tiles with screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 for laying of floor tiles including dismantling of old floor tiles including bedding (but not backing), and rubbish off permises complete all as specified and directed. (Note : The rates include for all straight cutting and waste.)
M&L for 10mm thick Light shade vitrified ceramic tiles in skirtings/ vertical surfaces, not exceeding 0.36 sqm, set & jointed in neat cement slurry and pointed in coloured cement to match with rendering 10 mm thick in cement mortar 1 : 4 for fixing of wall tiles including dismantling of old wall/dado tiles including bedding (but not backing), and rubbish off permises complete all as specified and directed. (Note : The rates include for all straight cutting and waste.)
M&L for 16 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl dismantling and rubbish off premises or removed to store complete all as specified and directed.
Providing & fixing False ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling with semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles of size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225 : 1987, Noncombustible as per BS tiles 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15 x 32 mm of length 3000mm, cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws incl dismantling of old False Ceiling. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. Note : The rates include for: (a) Use of all scaffoldings and cradles including hoisting and lowering. (b) Shifting of movable cupboards and furniture as required and replacing in position.
M&L for Providing and fixing perforated Gypsum Board 12 mm thick on walls fixed with screw as per manufacturers instructions incl dismantling of old False Ceiling complete all as specified and directed. Note : The rates include for: (a) Use of all scaffoldings and cradles including hoisting and lowering. (b) Shifting of movable cupboards and furniture as required and replacing in position.
S&F in repairs for Anodised aluminium frame for doors, windows, ventilators with one or more rebates, channels, flanges, tees etc including joining cleat for fixing etc complete all as specified and directed.
S&F Mild steel framed works such as grills,gratings,etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; framed balusters; walk ways; railings; framework of water tanks and similar work for portions framed and hung as gates, including pintle hinges, stops, hand made sliding bolts, etc conforming to Fe 290 Gde -E-165 incl dismantling wrought iron or mild steel work of any description complete all as specified and directed. (Note :-The rates include for riveting and/or welding as directed and fixing with screws, bolts, etc. complete)
M & L for preparation of new steel surfaces any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed.
M&L for applying Two coats of oil bound distemper on wall or concrete over a coat of primer over 1 mm thick Wall Care Putty including preparation on newly plastered surfaces complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceilings and apply three coat of white wash complete all as specified and directed.
M&L preparation of old painted surfaces and applying one coat of white wash on ceiling complete all as specified and as directed.
The rates (from Sch Item- 1 to Item - 14) include for: (a) Use of all scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures including hoisting and lowering. (b) Taking down, cleaning as directed and refixing blinds and fittings, picture rods, cornice poles and small items of builder’s hardware such as door knobs, finger plates, escutcheons, hooks etc. which are not required to be painted. (c) Use of dust sheets and other coverings for the protection of fixtures, fittings, furniture, etc. (d) Shifting of movable cupboards and furniture as required and replacing in position, Removing and replacing chicks, blinds, etc. (e) Work in patches (over one square metre each) including matching with existing work and marrying in at the edges. (f) Removing all splashes, drops, dirt, etc. and leaving premises in a clean state. (g) Removing of nails, making good holes, cracks, etc. (h) Work in patches, and in narrow \widths. bands, cornices, pilasters, etc. and cutting in edges to line, where necessary. (i) Spreading and removing coverings to doors, windows, floors, fittings, etc., to protect them from splashes. (f) Washing floors, cleaning glass, joinery, electric fittings, wiring, etc. of drops and splashes and leaving premise, clean and tidy.
M&L for taking down/dismantling of existing cassette type AC capacity 4 TR i.e; outdoor and indoor units by disconnecting all necessary electric/ charging pipe line connections & deposit the same to MES store yard of AGE E/M-II complete all as specified and directed.
M&L for taking down carefully copper/aluminium Sub main wiring of any size from surface / concealed / existing conduit of any height and removing materials at site and making good disturbed surfaces of walls , floors roofs etc complete all as specified and directed.
M&L for taking down carefully copper/aluminium point wiring of lights, fan, bell, sockets and power point complete with all fittings and fixtures such as switches, sockets, ceiling rose, flush boxes etc all as specified and as directed.
Taking down carefully AC box or SP/TPN DB of any size from surface / concealed of any height and removing materials at site and making good disturbed surfaces of walls ,floors roofs etc complete all as specified and directed.
Outdoor Unit: Supply, Installation, testing and commissioning of air cooled 100% inverter single / multiple compressor based Outdoor Unit of 18 HP capacity , non CFC refrigerant based variable refrigerant flow (VRF) modular type air conditioning system, suitable to operate at 400 V ±10%, 50 Hz electric supply , suitable for multi indoor units with external condensing units, copper refrigerant pipe, drain pipe, Outdoor Unit MS stand, transmission cum control wiring cordless remote controls, provision of winter heating arrangement (Heat recovery Ventilation System), suitable to operate at 50 degree C without tripping, equipped with Micro-processor control panel, sub cooler, accumulator, low noise condenser fan with DC motor, auto check function for connection error, auto address setting, vibration isolator and all the necessary accessories for proper functioning of the units for maintaining inside temperature (22±2) Degree Celsius considering weather condition of Mhow.
Indoor Unit: Supplying, installing, testing and commissioning of Indoor Unit Cassette type of 4 TR capacity with wireless remote controller air cooled 100% inverter compressor based , non CFC refrigerant based variable refrigerant flow (VRF) modular type air conditioning system, suitable to operate at 400 V ±10%, 50 Hz electric supply, full charge of refrigerant with additional top up if required, drain pipe, MS slotted angle irons, provision of winter heating arrangement (Heat recovery Ventilation System) etc , suitable to operate at 50 degree C without tripping including all accessories complete all as specified & directed.
Supply, fixing and testing of copper refrigerant piping with insulation for interconnection between each set of indoor units and outdoor units as per tentative scheme attached by OEM along with Y joint set fittings and any other item to make system complete duly insulated with closed cell elastomeric nitrile rubber tubular insulation complete all as per approved OEM instructions, as specified and directed ”. The work shall be carried out by BLUE STAR (or) CARRIER (or) HITACHI (or) Voltas or equivalent as per the drawings submitted by contractor and duly approved by Garrison Engineer..
Supply, installation, testing & commissioning of 32 mm Rigid PVC Drain Piping of 6 Kg./CM2 rating with insulated with 9mm thick nitrile foam rubber trenched on walls, ceiling suspended, hanged with all necessary clamps, saddles & supports. Complete all as specified and directed.
S&F flexible PVC drain piping 20/25 mm for indoor units complete with necessary fittings viz elbow, tees reducers etc complete all as specified and directed.
M&L for additional refrigerant topup for Refrigerant to compensate the additional piping done at site complete all as specified.
M & L sub main wiring with 4 runs of 10 sqmm single core multistranded FRLSH PVC copper wire as main wire with color coding along with 2 run of 06 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC concealed / surface conduit (medium grade) as required for power supply to outdoor units with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the disturbed surface by plastering and 02 coats of wall putty incl distempering to match with the existing surface complete all as specified and directed. NOTE:- Four runs of main copper conductor, two run of earth wire and one run of PVC conduit shall be measured as one unit length.
M & L sub main wiring with 2 runs of 06 sqmm single core multistranded FRLSH PVC copper wire as main wire along with 1 run of 06 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC concealed / surface conduit (medium grade) as required for power supply to indoor units with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the disturbed surface by plastering and 02 coats of wall putty incl distempering to match with the existing surface complete all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
S & F for VTPN DB 8 way having weather proof enclosure with 160 Amp MCCB as Incomer, 200 Amps rated bus bar415 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
Supply and fixing 415V 10KA 'C' curve TPN miniature circuit breaker (MCB) of 63 Amp current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixed in replacement, sheet metal Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB capacity 32 Amps 440 Volts complete all as specified & directed.
Supply, laying, connecting and termination XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sq. mm 3.5 core with saddles/ clamps supports and other accessories as required. The cable shall be laid in air, in existing pipe/on existing cable tray with clamp or in trenches as required as per specifications with inscriptions there on with suitable size of gland & lugs incl connecting to existing LT panel board and VTPN DBs all as directed at site.
M&L for Tubes,'light grade,galvanised,with all fitting of size 63/50 mm ;laid in trenches or fixed in wll with saddles for cable protection/ mounting security lights incl bending and cutting to required length all as specified and directed
Excavation in trenches not exceeding 1.5 metre wide & not exceeding 1.5 meter in depth for foundation ,laying of cable or pipe ( where provide for protection of cable or fixing poles and stay and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed .
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm complete all as specified and as directed.
Supply and laying fine sand for cable protection in layers incl punning complete all as specified and as directed. Note :- Punned thickness shall be measured for the payment.
S&F mild steel slotted cable tray of size 300 mm x 50 mm x 1.6 mm for refrigerant piping, transmission wiring.
S&F mild steel slotted cable tray of size 200 mm x 50 mm x 1.6 mm for refrigerant piping, transmission wiring.
M&L for replacement of Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level connect to galvanised earth lead wire of 4.0 sqmm size by means of bolts, nuts, check nuts and washers of galvanized iron or steel up to 7.5 meter length including connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC cover 1:2:4 mix with 6mm dia nominal reinforcement @ 150 mm c/c both ways etc complete all as shown in electrical plate No 3, connected to earthing test point complete including testing on completion all as specified.
M&L for replacement of Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level connect to GI strip 32x6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron or steel up to 7.5 meter length including connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC cover 1:2:4 mix with 6mm dia nominal reinforcement @ 150 mm c/c both ways etc complete all as shown in electrical plate No 3, connected to earthing test point complete including testing on completion all as specified.
Taking down ceiling fan / wall fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and refixing in repairs in serviciable condition with electrical connections & fittings received from taking down complete all as specified and as directed.
Taking down recessed type ceiling light of size 600*600 mm after disconnecting all necessary electrical connections and refixing in repairs after cutting false ceiling to the extent required for accomodation of ceiling light in serviceable condition with electrical connections complete all as specified and as directed.
Taking down accent/ focus or equivalent light after disconnecting all necessary electrical connections and refixing in repairs as existing in serviciable condition with electrical connections complete all as specified and as directed.
Taking down LAN Audio set of any size from ceiling or wall after disconnecting all necessary electrical connections refixing in repairs in serviciable condition with electrical connections & fittings received from taking down complete all as specified and as directed.
Taking down Wall Mounted Portrait of any size after disconnecting all necessary screw & nuts & refixing in repairs in serviciable condition with fittings received from taking down complete all as specified and as directed.
Taking down Projector set with LCD screen after disconnecting all necessary screw & nuts & refixing in repairs in serviciable condition with fittings received from taking down complete all as specified and as directed.
Taking down LED/LCD TV with NET/LAN cabling & refixing in repairs in serviciable condition with fittings & NET/LAN cabling received from taking down complete all as specified and as directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
Point wiring with 1.5 Sqmm (nominal cross sectional area ), single core, PVC insulated with multistranded PVC unsheathed FR LSH copper conductor cable in and including rigid non- metallic PVC concealed conduit of suitable size medium grade ISI marked complete , including one continuity earth wire of PVC insulated, unsheathed 1.5 Sqmm (nominal cross sectional area ) FR LSH copper conductor connected to all fittings, common earth and connected to earth dolly including modular metal flush box , cover plate and cover frame of suitable size complete all as specified and directed for the following:-
One light / fan controlled by one, one way switch 5/6 Amps
One 3 pin, 5/6 amps socket outlet point on independent board controlled by one, one way 5/6 amps switch
One 3 pin, 5/6 amps socket outlet point on same board controlled by one, one way 5/6 amps switch
Point wiring with 2.5 Sqmm (nominal cross sectional area ), single core, PVC insulated with multistranded PVC unsheathed FR LSH copper conductor cable in and including rigid non- metallic PVC concealed conduit of suitable size medium grade ISI marked complete including one continuity earth wire of PVC insulated, unsheathed 1.5 Sqmm (nominal cross sectional area ) FR LSH copper conductor connected to all fittings, common earth and connected to earth dolly for one three pin 15/16 amps socket out-let point on an independent board including modular metal flush box , cover plate and cover frame of suitable size complete all as specified and directed
S&F in replacement of Ceiling rose three terminals surface bakelite type, AC, 50 HZ, 230V
S & F modular switch 1 way 6 A , 1 module complete all as specified and directed.
S & F modular socket 6 Amps 2/3 pin combined 2 module complete all as specified and directed.
S & Fswitch modular type 16 A, 1 module complete all as specified and directed.
S & F socket modular type multipurposes 6/16 A, 2 module complete all as specified and directed.
S & F fan regulator stepped electronic capacitive type, modular type 02 module , 100 watts all as specifed and directed.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
BOQ_846601.xls
BOQ • 2.11 MB
Tdocus.pdf
Tender Documents • 0.82 MB
Makelist.pdf
Tender Documents • 0.48 MB
Download all tender documents and submit your bid