Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.4 LAccepted-AOC E 73 FF GALI NO 17B SADH NAGAR PALAM COLONY NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹30.4 L+₹97,282 (3.31%)Rejected-AOC 0001 000 KACHARI ROAD RAMAIPATTI MIRZAPUR UTTAR PRADESH 231001 | MIRZAPUR | UTTAR PRADESH | 231001 | L2 | Rejected-AOC Not L1 Bidder | |
| 3 | L3₹33.2 L+₹3.8 L (12.8%)Rejected-AOC | L3 | Rejected-AOC Not L1 Bidder | |
| 4 | L4₹38.9 L+₹9.5 L (32.3%)Rejected-AOC | L4 | Rejected-AOC Not L1 Bidder | |
| 5 | L5₹39.7 L+₹10.3 L (35.0%)Rejected-AOC RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L5 | Rejected-AOC Not L1 Bidder |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
20 Apr 2024, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
REPAIR MAINTENANCE OF MONOBLOCK SUBMERSIBLE AND CENTRIFUGAL PUMP SETS INCLUDING DEVELOPMENT OF BOREWELLS AND CONNECTED ITEMS OF WATER SUPPLY INSTALLATIONS OF CVD AREA PIRU VIHAR SIGNAL GROUP DAD NSB III AND ADJOINING AREAS OF AGE U WATER SUPPLY NO I
2024_MES_647720_1
GE/WS/IFA-175/Token-81 OF 2023-24
Open Tender
Civil Works
Item Rate
330 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹88,000
Yes
3 Sept 2024
23 Mar 2024
22 Apr 2024
23 Mar 2024
20 Apr 2024
6 Apr 2024
Amount
Disconnecting electric connections from LT control panel and starter of submersible pump set of size 2 to 15 HP and removing the pipe line connections from discharge side and taking down/out submersible pump set along with column pipe from bore well with the help of chain pully block including transportation to workshop for repairs and back and lowering of same pump in bore well after repairs after replacement of rusted nuts, bolts, washers, rubber gasket etc including testing & commissioning complete all as specified and directed (Note : Serviceability of pumpset after repair shall be got tested by EIC before re-installation and lowering. Each pump maintenance/functionality/serviceability will be covered for one year after satisfactory repair and if pump motor winding brunt out in the contract period or within defect liability period of one year, the same will carried out by contractor Free of cost at own arrangement. A BOO will be ordered for serviceability & functionality of pump after repair from work shop and the same will be kept on record dully concered by Accepting Officer. These aspect will be considered during quoting rate of unit (Each Job)
Disconnecting electrical connections from panel board including disconnecting the cable leads from the motor terminal box and taking down/out electric motor of any capacity and makes from base plate of pump set after opening the nuts, bolts etc and Dismantling of the induction/Submersible motor and seperate the stator and rotor and removing the Unserviceable DE & NDE side bearing, burnt winding wire from stator and rewinding the same as per existing supper enamelled copper wire gauge 'F' class insulation used including varnishing and heating for drying of winding, transporting the motor to workshop for repair and back, re-installed after repair including testing complete all as specified and directed (Note : (i) Bidder will quote all in all rate according to weight of copper rewinding retrieved after dismentling and mode of measurement of the item is in "KG" only for all the repair/overhandling. Please quote rate accordingly, no any extra cost will be paid by Govt. (ii) A BOO conveyed for working out old unserviceable copper winding quantity details of each pump and the same replaced with new super enamel copper wire of suitable gauze as per old pumps make and submit serviceability / functionality of pumps.
(iii) Old unserviceable/brunt copper winding wire in 'KG' shall be taken in salvage/demolition ledger and the same will be mentioned in demolition certificate with page number & ledger number.
Disconnecting electric connection and De-coupling the Centrifugal pump and removing from foundation for repair after opening /cutting the rusted nuts, bolts etc and dismantling complete pump and repairing the same with replacing the following unserviceable spare parts i.e. CI Casing wear ring, interstage ring, stuffing box bush, lentern ring, eye bolt with nut, shaft sleeve, impeller key, coupling key, water liquid reflector, bearing cartridge, bearing plate, shaft bush, MS stud with nut, mechanical seal, gasket packing including grinding work of lathe machine if any and re-assembling the same including the transporting the pump from side to workshop for repair and back, re-installed at existing position after repair and providing new MS nuts, bolts, packing flange etc including testing complete all as specified and directed of following capacity:-
5 to 10 HP Capacity centrifugal pump
20 HP Capacity Centrifugal pump
30 HP Capacity Centrifugal pump
40 & 50 HP Capacity Centrifugal pump
(Note:- (i) Proper inventory for repair and over hauling parts replaced during the repair in work shop shall be prepared and kept in record dully verified and signed by EIC. (ii) Old unserviceable parts repaired & replaced shall be taken on charge under demolition/salvage register with page number in demolition statement.)
Disconnecting the electric connection of monoblock pump of capacity 10 HP and removing the same from foundationfor repair after opening /cutting the rusted nuts, bolts etc and dismantling complete pump and repairing the same with replacing the following unserviceable spare parts i.e CI Impeller, GM shaft sleeve, Mechanical seal, water seal, water liquid reflector, MS stud with nut, gasket packing including grinding work of lathe machine and re-assembling the same including the transporting the pump from side to workshop for repair and back, re-installed at existing position after repair and providing new MS nuts, bolts,packing flange etc including testing complete all as specified and directed. (Note:- (i) Proper inventory for repair and over hauling parts replaced during the repair in work shop shall be prepared and kept in record dully verified and signed by EIC. (ii) Old unserviceable parts repaired & replaced shall be taken on charge under demolition/salvage register with page number in demolition statement.)
Dismantling complete submersible pump and repairing the same with replacing the following unserviceable spare parts i.e GM bush, rotor sleeve, water seal,cable seal, thrust bearing, sealing ring, upper & lower housing flange upper & lower with stud and nut, wire mesh, drain plug, SS distance sleeve, impeller key, inter ring GM neck ring, Guide bush, GM impeller/EPV Impeller, CI section chamber,SS coupling, CI stage bowl, T bolt with nut including grinding work of lathe machine and re-assembling the same testing, complete all as specified and directed of following capacity:- (Note:- (i) Proper inventory for repair and over hauling parts replaced during the repair in work shop shall be prepared and kept in record dully verified and signed by EIC. (ii) Old unserviceable parts repaired & replaced shall be taken on charge under demolition/salvage register with page number in demolition statement.
5 to 7.5 HP Submercible pump
Submersible pump of capacity 10 to 12.5 HP
Disconnecting the all electric connection and lifting the raw sewage pump set from sludge well/equilisatin tank and dismantling complete raw sewage submersible pump of capacity 5 to 7.5 HP and repairing the same with replacing the following unserviceable spare parts i.e GM bush, rotar sleeve, water seal, thrust bearing, sealing ring, upper & lower housing flange upper & lower with stud and nut, wire mesh, drain plug, SS distance sleeve, impeller key, inter ring GM neck ring, Guide bush, GM impeller, CI section chamber,SS coupling, EPV impeller, CI stage bowl, T bolt with nut including grinding work of lathe machine and re-assembling the same testing complete all as specified and directed. (Note:- (i) Proper inventory for repair and over hauling parts replaced during the repair in work shop shall be prepared and kept in record dully verified and signed by EIC. (ii) Old unserviceable parts repaired & replaced shall be taken on charge under demolition/salvage register with page number in demolition statement.)
Supplying and Fixing in replacement of Terminal Connection Plate of following capacity:- (Note:- Old U/s material Terminal connection plate obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV Iron Scrap in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply and fixing spare tyre for coupling type TC/P/011 after taking down/out as existing at site complete all as specified and directed
Supply and fixing spare tyre for coupling type TC/P/013 after taking down/out as existing at site complete all as specified and directed
Supply and fixing spare tyre for coupling type TC/P/014 after taking down/out as existing at site complete all as specified and directed
Supply and fixing spare tyre for coupling type TC/P/015 after taking down/out as existing at site complete all as specified and directed. (Note for ser item No 8 to 11:- Old unserviceable material spare tyre shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
Supply and Fixing in replacement of Ball Bearing 6205 as per existing complete all as specified and directed.
Supply and Fixing in replacement of Ball Bearing 6305 as per existing complete all as specified and directed.
Supply and Fixing in replacement of Ball Bearing 6306 as per existing complete all as specified and directed.
Supply and Fixing in replacement of Ball Bearing 6307 as per existing complete all as specified and directed.
Supply and Fixing in replacement of Ball Bearing 6308 as per existing complete all as specified and directed.
Supply and Fixing in replacement of Ball Bearing 6309 as per existing complete all as specified and directed.
Supply and Fixing in replacement of Ball Bearing 6310 as per existing complete all as specified and directed.
Supply and Fixing in replacement of Ball Bearing 6311 as per existing complete all as specified and directed.
Supply and Fixing in replacement of Ball Bearing 6312 as per existing complete all as specified and directed. (Note for ser item No 11 to 20:- Old unserviceable material ball bearing shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
M&L applying two coat of synthetic enamel paint as per existing pattern or scheme, on centrifugal pump & motor of any capacity rating 5-120 HP and suction/ delivery pipeline including NRV and sluice valve, MS Base channel after removing of existing paint including preparation of surfaces by scratching and removing the rust complete all as specified and as directed.
M&L for pump shaft stainless steel suitable for centrifugal pump set up to 15 HP including turning, grinding and balancing work in work shop complete all as specified and directed by EIC.
M&L for pump shaft stainless steel suitable for centrifugal pump set up to 20-30 HP including turning, grinding and balancing work in work shop complete all as specified and directed by EIC.
M&L for pump shaft stainless steel suitable for centrifugal pump set up to 40-50 HP including turning, grinding and balancing work in work shop complete all as specified and directed by EIC. (Note for ser item No 22 to 24:- Old U/s material shaft obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV Iron Scrap in weight (KG) shall be taken into account and attach with RAR/F Bill)
M&L for CI Impeller suitable for centrifugal pump set up to 15 HP including turning, grinding and balancing work in work shop complete all as specified and directed by EIC.
M&L for CI Impeller suitable for centrifugal pump set up to 20-30 HP including turning, grinding and balancing work in work shop complete all as specified and directed by EIC.
M&L for CI Impeller suitable for centrifugal pump set up to 40-50 HP including turning, grinding and balancing work in work shop complete all as specified and directed by EIC. (Note for ser Item No 25 to 27:- Old U/s material CI Impeller obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV Iron Scrap in weight (KG) shall be taken into account and attach with RAR/F Bill)
M&L for taking up the suction pipe of size 80/100/150 mm dia after opening of Nuts and Bolts and open the bottom plate of Swing type CI Valve and replace the unserviceable leather Gasket of swing disc as per existing size but of minimum thickness not less than 6 mm complete all as specified and directed.
Supply and fixing in replacement GI Nipple with flange welded, heavy duty 40 x 300 mm size complete all as specified and as directed.
All as per serial item No 29.00 here-in-before but of size 50 x 300 mm
All as per serial item No 29.00 here-in-before but of size 80 x 300 mm (Note for ser Item No 29 to 31:- Old U/s material GI Nipple obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV Iron Scrap in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply and lowing in replacement of GI column pipe, heavy grade, class 'C', 50 mm bore of 3 metre length, heavy duty, flange welded on both ends complete all as specified and directed.
Supply and lowing in replacement of GI column pipe, heavy grade, class 'C', 80 mm bore of 3 metre length, heavy duty, flange welded on both ends complete all as specified and as directed. (Note for item No 32 & 33: Old U/s material GI Column pipe obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in length (RM) shall be taken into account and attach with RAR/F Bill)
S&F in replacement of submersible copper cable of size 2.5 Sqmm 3 Core. 1100 Volt complete all as specified and directed
All as per serial item No 34.00 here-in-before but cable of size 4 Sq mm 3 core, 1100 Volts .
All as per serial item No 34.00 here-in-before but cable of size 6 Sq mm 3 core, 1100 Volts . (Note for Ser Item no 34 to 36 :- Old U/s cable obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in length (RM) shall be taken into account and attach with RAR/F Bill)
M&L for Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 1100 volts LT cables of different sizes from both ends , removal of fault , reconnection and testing of cables after removal of fault complete all as specified and directed. NOTE:- (a) 1100 volt cables and joints shall be measured and paid for seperately under respective items of schedule (b) Retrieved old serviceable cable cover/ bricks will be laid in trenches for cable protection. If extra PCC cover / bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Exacavation and earth work will be measured and paid for separately under respective items of schedule.
Supply and fixing, testing & commissioning in replacement heat shrinkable jointkit suitable for XLPE cable insulated screened PVC bedded armoured electric power cable heave duty 1100 volts grade, with straded aluminium conductor, cross sectional area 25 to 35 Sqmm, 3.5 core after taking down/out faulty portion as exists compete all as specified and directed. (Note:- Old unserviceable Joint material shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
M & L for preparation of surfaces for painting of existing submersible pump sets of capacity 2 to 15 HP and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
Supply and fixing in replacement of Mild steel clamps in Mild steel flat of size 50mm x 6 mm with including two Nos Mild steel nut and bolts suitable for 50mm bore column pipe complete all as specified and directed.
Supply and fixing in replacement of Mild steel clamps in Mild steel flat of size 80 mm x 6 mm with including two Nos Mild steel nut and bolts suitable for 80mm bore column pipe complete all as specified and directed. (Note for ser Item No 40 to 41:- Old U/s material clamps obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV Iron Scrap in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply and fixing in replacement PVC insulated multistranded Aluminium wire 1100 volt, twin core of size 10.0 Sq mm complete all as specified and as directed.
Supply and fixing in replacement PVC insulated multistranded copper conductor wire 1100 volt, single core of following sizes complete all as specified and directed:-
(Note for Ser Item no 42 to 43.03 :- Old U/s aluminium & copper wire obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in length (RM) shall be taken into account and attach with RAR/F Bill)
Supply,Laying, jointing, Testing and commisioning of MS Pipe in replacement of following size, as per IS:1239 with and including MS flange, 16 mm thick welded for drilling of 16 mm dia bolts, nuts, washers, rubber gaskets etc laid in trenches complete all as specified and directed:-
(Note :- Old U/s MS Pipe obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in length (RM) shall be taken into account and attach with RAR/F Bill)
Supply & Fixing in replacement MS Flange of following sizes, 16 mm thick, duly welded on ends of MS pipe including necessary cutting to existing MS pipe or in new MS pipe with flange joint including nuts, bolts, washers and rubber gaskets complete all as specified and as directed:- (Note:- Old unserviceable MS Flange shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
Supply and Fixing in replacement of Vibration Pad with nuts, bolts and washers, for existing capacity of 40-75 HPcomplete all as specified and as directed. (Note:- Old U/s material Nut & bolts obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supplying and laying, testing & commissioning of LT XLPE insulated, armoured heavu duty electric cable with aluminium conductor 1100 Volts grade cross sectional area 25 Sqmm 4 Core laid in trenches/floor/wall incl taking out old unserviceable cable and connection to panel for incoming and outgoing using suitable aluminium lugs complete all as specified.
Supplying and laying, testing & commissioning of LT XLPE insulated, armoured heavu duty electric cable with aluminium conductor 1100 Volts grade cross sectional area 35 Sqmm 4 Core laid in trenches/floor/wall incl taking out old unserviceable cable and connection to panel for incoming and outgoing using suitable aluminium lugs complete all as specified. (Note For Ser Item No 47 & 48:- (i) Excavation & earth work will be measured and paid seperately under respective items. (ii) Old U/s LT XLPE aluminium cable shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in length (RM) shall be taken into account and attach with RAR/F Bill). (iii) Layout of LT XLPE cable shall be approved by ACcepting Officer before commencement & laying of cable. (iv) Route marked indicator will be provided by contractor and quoted rate deemed included such aspects. (v) Old unservieable brick/bricks bats shall be taken in charge
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft/ loose soil complete all as specified ans directed.
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all complete all as specified and directed.
Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified and directed.
Supply, fillings & spreading of fine 'Yamuna River' sand in trenches by providing 15cm below cable punned to 10cm after hand roller and 8cm above cable for cable protection complete all as specified ans as directed. NOTE: Punned down thickness of sand shall only be taken for measurement & payment.
M&L for laying kiln burnt brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm width of brick equal to length of trench across the cable complete all as specified and as directed
M&L for taking out old and broken PCC pole of any size/height from the existing size by breaking the foundation and dismantlimg the cable connections complete all as specified and directed by Engr-in-Charge.
Excavating in post holes each not exceeding 0.5 cum in soft / loose soil, getting out, returning filling in and ramming earth or broken rubble mixed with around earth in layers not exceeding 25 cm thick, watering and removing surplus soil to a distance not exceeding 50 metre and making good surface
M&L preparation of old surfaces of LT steel tubular poles of any size and type with bracket clamps etc and painting with two coats of Aluminium paint upto 9 mtr long (410 SP-31) and exposed surface of Pole yellow and black paint in strips alternative 30 cm wide ipto 1.5 mtr from ground level including marking of pole No's with paint complete all as specified and directed. (Note:- Excavation & earth work & PCC shall be measured and paid seperately under repsective item only).
M&L Providing for PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundations filling mass concrete bed of pipe etc complete.
M&L Providing for PCC (1:2:4) type B-1 using 20mm grded crushed stone aggregate as in coping bed plate including weathering slightly rounded or chamfered angles and throating etc complete all as specified and directed.
Supply and fixing poly carbonate junction box, in replacement weather and vermin proof of suitable size including provn of 2 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators , including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, earthing bolt, double washer and galvanised flat iron clamps of suitable size for taking connections and fixing on LT steel tubular poles complete with locking arrangement complete including cable gland of suitable size at entry and exit point of cable. Note: (i) Box shall be provided at 1 metre above the pedastal of pole. (ii) Quoted rate shall be deemed to include bus bars, MCB and clamps. (iii) Old U/s material box obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV Iron Scrap in weight (KG) shall be taken into account and attach with RAR/F Bill)
Openning of gland packing coupling and removing the unserviceable gland rope from centrifugal/Monoblock pump set of capacity 15 to 50 HP and fixing the new gland rope all as per existing size gland rope complete all as specified and directed.
Openning of gland packing coupling and removing the unserviceable gland rope from Sluice valve of size 100 to 300 mm dia and fixing the new gland rope all as per existing size gland rope complete all as specified and directed. (Note:- Old U/s gland plate obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
S&F including testing & commissioning of Decorative ultra slim round profile LED lightning fixture 20W,6000K, with extruded polycarbonate environmental friendly energy efficient incl taking down old unsv light fitting complete all as specified and as directed. (Note:- Old unserviceablelight fittings shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
Supply and fixing including testing & comiisioning in replacement 45 watt LED street light New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 including making connections with GI pipe 0.6mtr angle braket fixing on wall and connectng to ceiling rose with apropriate wire complete all as specified and directed. (Note:- Old unserviceable light shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
Supply and fixing in replacement exhaust Fan metal body, heavy Duty 450 mm sweep, 1400 RPM Single pole 230V , 50Hz complete all as specified and directed.
Supply and fixing in replacement ceilling fan 1200 mm sweep Single pole 230V , 50Hz 'Five Star' complete with five step electronic fan regulator and down rod connection complete all as specified and directed. (Note for Ser Item No 64 & 65:- Old unserviceable fan exhaust cealing fan shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
S&F in replacement of GI Pipe 80 mm dia medium grade along with all fittings laid in trenches/floor all as per exisiting and complete all as specified and directed by Engr-in-Charge.
S&F in replacement of GI Pipe 20 mm dia medium grade along with all fittings laid in trenches/floor all as per exisiting and complete all as specified and directed by Engr-in-Charge. (Note for Ser Item No 66 & 67:- Old U/s GI pipe obtained from demolition shall be taken on charge in demolition/ salvage register and enter page number in demolition statement. Necessary RV in length (RM) shall be taken into account and attach with RAR/F Bill)
S&F in replacement of Gun Metal Gate Valve 20 mm dia with iron wheel head screwed both ends for iron pipe as per IS-778 complete ISI marked complete all as specified and directed by Engr-in-Charge. (Note:- Old unserviceable gate valve shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
Supply and Fixing in replacement MS base channel of size as exists including cutting, welding and making hole, applying two coats of synthetic enamel paint over a coat of red oxide primer including dismounting existing Centrifugal pump motor set and taking out old unservicable existing MS Base chennel complete all as specified and as directed. (Note:- Old U/s material MS frame obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply and Fixing in replacement of MS foundation bolts with nuts and washers, size 20mm dia, 450 mm long complete all as specified and as directed.(including breaking of hard standing foundation) (Note:- Old unserviceable bolts shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
Supply and fixing rotational moulded polyethylene water storage tank , cylindrical vertical with closed top, 500 ltrs capacity, triple layered hoisted and fixed in position after taking down as existing at site (of any capacity) complete all as specified an as directed. Note: For Pump Priming purpose in pump house.
Supply and fixing rotational moulded polyethylene water storage tank , cylindrical vertical with closed top, 1000 ltrs capacity, triple layered hoisted and fixed in position after taking down as existing at site (of any capacity) complete all as specified an as directed. (Note: (i) For Pump Priming purpose in pump house. (ii) Old unserviceable PVC tank shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
M&L for development of bore well of any capacity and size at the pressure 10 kg/sqcm to 15 kg/sqcm by diesel engine driven air compressor of capacity 620 cfm includiing air pipe and connected items to improve the yield of tube well complete all as specified and directed by Engineer in charge.
M&L for development of bore well of any capacity and size at the pressure 22 kg/sqcm to 25 kg/sqcm by DTH Machine of capacity 1200 CFM including air pipe and connected items to improve the yield of tubewell complete all as specified and directed by Engineer in charge. (Note : The rate deemed to include the cost of Transportation of machine and minimum 1 Hrs of running.)
Taking down cement plaster or cement lime plaster on PCC/Stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed .
M&L rendering 15 mm thick in CM (1:4) on fair faces of brickwork or concrete surfaces finished even & smooth complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoin jambs pillars etc complete all as specified and directed. (Note:- Old U/s material brick/brick bats obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (CUM) shall be taken into account and attach with RAR/F Bill)
M&L Brick work with sub class 'B' old size kiln burnt bricks straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for coloured Glazed ceramic tiles premium 1st quality in vertical surfaces of size 300mm x 200mm, 7 to 8mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick scred bed or backing layer in cm (1:4) & demolition of existing broken tiles of wall complete all as specified and directed.
Demolition and dismantling concrete in ground floors and pavings n exc 15 cm thickness below or above ground level complete all as specified and directed.
M & L for PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation for including fair finish even and fair to exposed surfaces without using extra cement complete all as specified and as directed.
Hacking out old broken glass any thickness, size, quality or description from wooden frames or stone, concrete or brick surrounds glazed with putty or fixed with beads including S&F 3 mm thick plain sheet glass ordinary quality in square not exceeding 0.5
Supply and fixing & installation in replacement of perforated MS cable tray of size 350x50x2mm including horizontal and vertical bends, prepared hanging system and other accessories including painting of cable tray of complete all as specified and directed. (Note:- Old U/s MS Cable obtained from demolition shall be taken on charge in demolition/ salvage register and enter page number in demolition statement. Necessary RV in length (RM) shall be taken into account and attach with RAR/F Bill)
M&L for fabrication running (welding work ) of MS Header/ any size upto 300mm MS pipe at various pump house site for connection of pipe, arresting leakges on header complete all as specified and directed.
Excavation in trenches by cutting of road crossing, PCC hard standing for taking out/laying of cables including M& L for PCC (1:2:4) type B-I (with 20 mm graded aggregate) as in coping, grouting, finished even and smooth without using extra cement as on brick work/flooring complete making good the existing surface complete all as specified and as directed.
S&F in replacement of analog type time switch FM 1/ Quartz daily 240 VAC, flush mounting, 50 Hz Code No. J648F1 complete all as specified and as directed.
M&L for replacement to Off load Change over Switch of rating 200 Amp, 4-Pole 415V as per IS / IEC: 60947 - 1&3 with dual mounting facility fixed at exisiting/new location incl the connections complete all as specified and directed by Engr-in-Charge.
M&L for replacement to Off load Change over Switch of rating 400 Amp, 4-Pole 415V as per IS / IEC: 60947 - 1&3 with dual mounting facility fixed at exisiting/new location incl the connections complete all as specified and directed by Engr-in-Charge. (Note for ser item No 87 to 89:- Old U/s change over switch & time switch obtained from demolition shall be taken on charge in demolition/ salvage register and enter page number in demolition statement. Necessary RV in length (EACH) shall be taken into account and attach with RAR/F Bill)
M&L for replacement to copper Bus Bar Chambers of rating 200 Amp, 4-Pole 415V 6 Way as per IS: 2675/1966 with mounting facility fixed at exisiting/new location incl the connections complete all as specified and directed
M&L for replacement to Bus Bar Chambers of rating 400 Amp, 4-Pole 415V, 6 Way as per IS: 2675/1966 with mounting facility fixed at exisiting/new location incl the connections complete all as specified and directed. (Note for ser item No 90 to 91:- Old U/s copper bus bar obtained from demolition shall be taken on charge in demolition/ salvage register and enter page number in demolition statement. Necessary RV in length (KG) shall be taken into account and attach with RAR/F Bill)
Supply & fixing , install testing and commissioning of feeder pillar box ,outdoor type cubical shape,three phase, 4 wire, copper bus bar for phases and neutral made out of CRCA sheet 3.15 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery busbar, switch gear & danger Notice plate of size 300x200mmx3mm thick marked skull & bones with highlightend flourescent glow paint etc all as specified and comprising of following including necessary cable connections to the MCCBs, voltmeter, Ammeter and cable lugs etc & dismantling of old unserviceable LT panel with all accessories in any conidtion from foundation for shifting to MES store yard:-
(i) Copper bus bar with PVC sleeve rating 200 Amps for Phase & 200 Amp for Neutral - 01Set.
(iv) Phase indicating lamps LED type ( RYB) 01 Set (Set of Three)
(v) Incoming MCCB 125 Amp 3 pole 18 KA with adjustable thermal and fixed magnetic release -01 No
(vi) Outgoing MCCB 63 Amp 3-Pole 18 KA with adjustable thermal and fixed magnetic release - 01 No
(vii) FASD Stater ML-1.5 or MN-16 FASD-01 No
(viii) Analog time switch -01 No
(ix) Single phase preventer-01 No
(Note :- (i) Panel drawing shall be approved by Accepting Officer. (ii) Old unserviceable LT panel alongwith all accessories in any condition shall shifted to MES store yard and it will be taken on charge under demolition/salvage register. (iii) Make of accessories will be as per CA scpefication list of make & manufacturer's. (iv) The rate quoted deemed included all wiring & connection and testing installation & comissioning work.
Supplying, fixing, testing and commissioning of feeder pillar box, indoor type cubical shape, 3 Phase, 4 Wire, Aluminium bus bar of 200 Amps with PVC sleeve suitable for phases and neutral, made out of CRCA sheet 2.0 mm thick ,factory fabricated ,CPRI approved , powder coated ,dust and vermin proof , with provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery busbar, switch gear & danger Notice plate of size 300x200mmx3mm thick marked skull & bones with highlightend flourescent glow paint etc all as specified and comprising of following including necessary cable connections to the MCCBs, voltmeter, Ammeter and cable lugs etc & dismantling of old unserviceable LT panel with all accessories in any conidtion from foundation for shifting to MES store yard:-
Incoming: MCCB TPN 125 Amps, 36 kA rupturing capacity - 01 Nos
Outgoing: MCCB TP 63 Amps, 35 kA rupturing capacity - 03 Nos
MCB SPN 32 Amps, 10 kA rupturing capacity - 02 Nos
FASD Starter, MN 32 FASD - 03 Nos
On-load Changeover Switch 200 Amps 4 pole 415 volts - 01 No
Indicating Lamps (set of three) - .1 No
(Note :- (i) Panel drawing shall be approved by Accepting Officer. (ii) Old unserviceable LT panel alongwith all accessories in any condition shall shifted to MES store yard and it will be taken on charge under demolition/salvage register. (iii) Make of accessories will be as per CA scpefication list of make & manufacturer's. (iv) The rate quoted deemed included all wiring & connection and testing installation & comissioning work.
Supplying, fixing, testing and commissioning of feeder pillar box, indoor type cubical shape, 3 Phase, 4 Wire, Aluminium bus bar of 200 Amps with PVC sleeve suitable for phases and neutral, made out of CRCA sheet 2.0 mm thick ,factory fabricated ,CPRI approved , powder coated ,dust and vermin proof , with provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery busbar, switch gear & danger Notice plate of size 300x200mmx3mm thick marked skull & bones with highlightend flourescent glow paint etc all as specified and comprising of following including necessary cable connections to the MCCBs, voltmeter, Ammeter and cable lugs etc & dismantling of old unserviceable LT panel with all accessories in any conidtion from foundation for shifting to MES store yard:-
Incoming: MCCB TPN 125 Amps, 36 kA rupturing capacity - 01 No
Outgoing: MCCB TP 32 Amps, 25 KA rupturing capacity - 03 Nos
MCB SPN 32 Amps, 10 KA rupturing capacity - 02 Nos
FASD Starter, MN 25 FASD - 02 Nos
On-load Changeover Switch 100 Amps 4 Pole, 415 Volts - 01 No
Indicating Lamps (set of three) - .1 No
(Note :- (i) Panel drawing shall be approved by Accepting Officer. (ii) Old unserviceable LT panel alongwith all accessories in any condition shall shifted to MES store yard and it will be taken on charge under demolition/salvage register. (iii) Make of accessories will be as per CA scpefication list of make & manufacturer's. (iv) The rate quoted deemed included all wiring & connection and testing installation & comissioning work.
Supply, installing, testing and commissioning factory made and tested (prototype having been CPRI type test certified), LT feeder pillar box (KIOSK), Indoor type and double door with buckled type bush hinges platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bars 600 Amps rating installed on procelain insulators. The panel shall be dust and vermin proof with suitable IP protection and made of 2.0 mm CRCA MS sheet for outer sheet, 5mm thick bottom sheet & 1.2mm thick for inner sheet for individual compartment of MCCB's, bus bar, apron etc. Back side compartment with enclosure duly for space out going cables with extended bus bar/strips for out going MCCB's etc and 40 x 40 x 6mm thick angle iron frame work, externally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) lock 7 levers with 2 keys, & danger Notice plate of size 300x200mmx3mm thick marked skull & bones with highlightend flourescent glow paint etc intenal wiring with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 Sqmm & dismantling of old unserviceable LT panel with all accessories in any conidtion from foundation for shifting to MES store yard:-
(i) Incoming MCCB 400 Amp 3 pole 35 KA with adjustable thermal and fixed magnetic release -01 No
(ii) Outgoing MCCB 250 Amp 4-Pole 35 kA with adjustable thermal and fixed magnetic release - 01 No
(iii) Outgoing MCCB 160 Amp 4-Pole 35 kA with adjustable thermal and fixed magnetic release - 02 Nos
(iv) Outgoing MCCB 125 Amp 3-Pole 18 kA with adjustable thermal and fixed magnetic release - 02 Nos
(vii) Phase indicating lamps LED type ( RYB) 01 Set (Set of three)
(Note :- (i) Panel drawing shall be approved by Accepting Officer. (ii) Old unserviceable LT panel alongwith all accessories in any condition shall shifted to MES store yard and it will be taken on charge under demolition/salvage register. (iii) Make of accessories will be as per CA scpefication list of make & manufacturer's. (iv) The rate quoted deemed included all wiring & connection and testing installation & comissioning work.
Supply and installation of flanged ends Water Meter woltman type, including testing and making good connection with flanged ends, with gasket rubber sheet and nut & bolts etc ISI Marked fixing in horizontal/incline/ vertical position, including taking out unserviceable of following sizes complete all as specified and as directed at site by the Engineer-in-Charge:-
100 mm bore
(Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/ salvage register and enter page number in demolition statement. Necessary RV in length (EACH) shall be taken into account and attach with RAR/F Bill)
Supply and Fixing in replacement of CI Foot valve of following size , Flanged ends, Swing type opration with rubber sheet as per IS-4038 including taking out unserviceable of following sizes all as specified and directed by Engineer-in-Charge. (Note :- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this items.)
80 mm bore
100 mm bore
150 mm bore
(Note:- Old U/s material CI Foot Valve obtained from demolition shall be taken on charge in demolition/ salvage register and enter page number in demolition statement. Necessary RV in length (EACH) shall be taken into account and attach with RAR/F Bill)
Supply and installation of flanged ends strainer/dirt box, PN-10 with stainless steel mesh suitable for water meter for potable water supplies on up stream of water meter to avoid foreign material entering into meter including taking out unserviceable of following sizes complete all as specified and as directed at site by the Engineer-in-Charge. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/ salvage register and enter page number in demolition statement. Necessary RV in length (EACH) shall be taken into account and attach with RAR/F Bill)
100 mm bore
Supply & Installating including jointing and testing of cast iron sluice valves class PN-1.0, conforming to IS:14846 flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and rubber gaskets including taking out unserviceable sluice valve and removal from site for the follwing sizes complete all as specified. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/ salvage register and enter page number in demolition statement. Necessary RV in length (EACH) shall be taken into account and attach with RAR/F Bill)
80 mm bore
100 mm bore
150 mm bore
Supply and fixing jointing and testing of cast iron Non return valve without by pass arrangment swing type confirming to IS 5312 flanged ends pressure rating PN 1.0 complete including taking out unserviceable NRV all as specified and as directed by Engineer-in-Charge. (Note - (i) Flanged joints complete with rubber jointing materail shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/ salvage register and enter page number in demolition statement. Necessary RV in length (EACH) shall be taken into account and attach with RAR/F Bill)
80 mm bore
100 mm bore
150 mm bore
KUSHAL ENTERPRISES
B.R. Enterprises
Sukhram & Sons
P S TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .