GE I R and D Kanpur
GE I R and D Kanpur DMSRDE Complex, GT Road Kanpur 208013
REPAIR, REPLACEMENT OF VARIES PARTS OF CEILING FANS, OVERHAULING, PAINTING, EXHAUST FANS, AIR CIRCULATORS, COOLING APPLIANCES, GEYSERS, AC CONNECTIONS, DBS FOR ACS, GEYSERS AND CERTAIN MISC WORKS UNDER GE (I) R AND D KANPUR
2020_MES_327948_1
8180/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Tech Area DMSRDE Kanpur
As per NIT
8 documents required · 8 mandatory
₹500
GE I R and D Kanpur
₹20,000
30 Dec 2020
25 Feb 2020
25 Mar 2020
25 Feb 2020
23 Mar 2020
10 Mar 2020
Amount
Ceiling & Exhaust Fan
Taking down and refixing after recify the defects carefully of ceiling fan any size and any sweep including dismantling of blades, down rods fan for recognize defects at site complete all as directed by Engineer-in-Charge.
Taking down and refixing after recify the defects carefully of exhaust fan any size and any sweep including dismantling of blades, for recognize defects at site complete all as directed by Engineer-in-Charge.
M&L for overhauling of ceiling fan any Make and sweep including dismantling, cleaning internally and externally, oiling, greasing, checking of electric connections, replacement of worn out check nuts, split pins, nuts, bolts and washers, sockets rebber real, clamps and minor repairing works and replacement of flexible wire and items etc. reassembling and testing on completion all as directed. Note :- Winding works will be taken seperatly
All as per serial item No 4.00 above but for exhaust fan/wall fan/fresh air fan etc of any Make and any size.
M&L for painting of ceiling fan of any size sweep including blades and canopies with white enameled approved spray paints one coat after cleaning dust etc and Marking of MES No ceiling fan such as MES No, and height of letter 2.5 cm in figures including sign writing with black enameled paints all as directed
M&L for painting of Exhaust fan of any size sweep including blades and canopies with white enameled approved spray paints one coat after cleaning dust etc and Marking of MES No Exhaust fan such as MES No, and height of letter 2.5 cm in figures including sign writing with black enameled paints all as directed
Removing the burnt copper winding of ceiling fan ,cleaning to cores and rewinding of ceiling fans with copper enameled wire of suitable size including film paper, sleaving and varnishing , 56” (1400mm) with replacement of flexible PVC copper wire 23/76 complete any make any type as directed by Engr-in- Charge .
All as per serial item No 8.00 above but 48”(1200 mm) sweep any make and any size
All as per serial item No 8.00 above but exhaust fan 18” sweep 450mm complete any make all as directed by Engr-in- Charge
All as per serial item No 8.00 above but exhaust fan 12” sweep(300 mm) dia complete
All as per serial item No 8.00 above but exhaust fan/ fresh air fan 9" (250mm) dia complete.
All as per serial item No 8.00 above but Wall fan 12'' /15" (300 mm/350 mm) dia complete
Renewal of ball bearing 6201ZZ size where required and as directed Make SKF/NBC.
Renewal of ball bearing 6202ZZ size where required and as directed Make SKF/NBC.
Renewal of ball bearing 6203ZZ size where required and as directed Make SKF/NBC.
Replacement of condensor 2.5 MFD where required and directed for ceiling fan
Replacement of condensor 4.00 MFD for exhaust fan where reqd and directed
Renewal of Gun metal bush where required as directed for ceiling fan or exhaust fan all as directed.
Renewal of shaft suitable for any make of ceiling fans and exhaust fans all as directed.
Replacement of existing ceiling fan down rod with medium grade galvanized iron/ stove enameled pipe 20mm / 15 mm dia including threading both side or MS conduit heavy duty including both end hole with clamp with rubber real and split pin cable entry hole and check nuts including 3 core copper conductor 23/76, PVC insulated wire complete all as specified and directed
S&F medium step type fan regulator 80 Watt, 240 Volt AC, Gold series "Gold medium step" ISI marked complete in replacement of old unserviceable resistance type regulator all as specified and directed. Make:- Code No.3111 of make Cona or equivalent in Anchor/SSK/Crabtree as approved by GE.
S&F wall mounted fans having 400 sweep with 240 Volts with all fixing arrangements and connection complete all as specified and directed. Make: Crompton Cat part: WMHIFLO WAVE or equivalent in Havells / Bajaj / Philips as approved by GE.
Water Heater (Geysers 25 Ltrs)
Taking down carefully and re fixnig after rectifying the defects of storage type water heater (Geysers) of 25/50 ltrs capacity and mechanically from all existing line, opening for inspection back plate of any make/ type and from any height and re-fixing after necessary repair/ replacement of unserviceable parts complete all as directed by Engr-in-Charge.
Supply and fixed heating element 1500 watt push/screw/ triangular type suitable for 25 ltrs capacity geysers ISI marked complete all as directed by Engr-in-Charge.
Supply and fixed thermostat switch suitable for 25 Ltrs capacity geyser of any make/ type with temperature range adjustable from 25 to 90 degree centigrade superior quality 20 Amp rating 220 volt AC supply complete.
Supply and fixed PVC flexible connection with two brass adopter as per existing samples/ suitable of carrying hot water fixed one end at geyser inlet / outlet water supply point complete .
Supply and fixing indicator lamp suitable for 220 volts AC supply circular/ rectangular (green/ red) as per sample with neon lamp of superior quality complete .
M&L for painting of Geyser of any size with existing colour enameled approved spray paints one coat after cleaning dust etc all as directed
S&F Geyser of 25 litres capacity having 5 star rating, 240 V, fixing with the help of washer grouting nuts etc as specified and directed. Make:- Havells Cat part No.ASESWH025 or equivalent in Crompton/ Bajaj / Philips as approved by GE.
Air Conditioner
Disconnection of suction and discharge line connection of sealed unit and taking out the defective sealed unit compressor from window type AC/split AC of any make replacing the defective compressor with any repaired one from any of the authorised workshop/manufacturer, refixing the compressor in the original position of window/split type AC making all existing connection complete all as directed for 1.5 ton Air conditioners complete all as specified and directed. Make : KIRLOSKAR / TECUMSCH /CARRIER / BLUE STAR.
Supply and fixing in replacement of compressor hermetically sealed type equipped with suitable rated capacity electric motor and over load protection and shall confirm to IS 10617, making all existing connection complete all as directed for 1.5 ton Window type/split type Air conditioners complete all as specified and directed. Make : KIRLOSKAR / TECUMSCH / CARRIER / LG/ SAMSUNG
Supply and fixing in replacement of compressor hermetically sealed type equipped with suitable rated capacity electric motor and over load protection and shall confirm to IS 10617, making all existing connection complete all as directed for 2.0 ton Window type/split type Air conditioners complete all as specified and directed. Make : KIRLOSKAR / TECUMSCH / CARRIER
M&L for Gas refrigerant M 22/ R-22a in the sealed system of of Window type Air conditioners 1.5 /2Ton capacity after checking leakage /pressure vacumising flushing the sealed unit including replacement of filter drier and capillary tube complete all as specified and directed.
All as per serial item No 36.00 above but Split type Air conditioner 1.5/2.0 ton capacity.
Taking down of window AC 1.5 ton/2. Ton capacity and cleaning /serviceing of AC, overhauling of blower motor replacement of worn out parts, prepration of body for painting one coat of black paint inner site and one coat synthatic enameled paint on the outer cover of AC and marking of SM/MES No. and testing of full load of summer season and reinstallation at site complete all as specified and directed. Note : Worn out parts shall be measured & paid seperately.
Taking out following defective items from window type AC 1.5 ton/split AC any make and supply and fixing following item directed by Engineer-in-Charge.
(a) Blower motor 1/6 HP with base/ rubber bush complete Make AUE/GE
(b) Condensor fan motor 1/5 HP make AUE/GE as per sample.
(c) Condensor fan blade.
(d) Drum type blower fan PVC type
(e) Running capacitor 36 mfd make EPCOS.
(f) Running capacitor 45 mfd make EPCOS.
(g) Starting capacitor 100 to 120 mf Make : "TESLA"
(j) Thermostate make Indfoss.
(k) Starting relay make Ranutrol.
(l) Cooling coil assembly.
(m) Condensor coil assembly.
(n) Wiring kit.
(o) Capacitor 6 mfd
(p) Blower motor 1/30 HP for in door unit split type AC.
(q) Running capacitor 45 mfd Make : "EPCOS"
Cleaning of cooling condenser system of split type AC 1.5 / 2 Ton capacity and checking the pressure/ leakage of suction / discharge line & charging of gas refrigent M-22 up to required pressure and in separet unit replacement of unserviceable air filte complete all as specified and directed.
WATER COOLERS
Disconnection of the compressor from suction and discharge line and taking out the sealed unit compressor from water cooler of any make ,replacing the defective compressor with repaired compressor from any of the authorised repair workshop /manufacturer, refixing the repaired compressor in the original position of the water cooler making all existing connection for 40/80 ltr capacity complete all as specified and directed.
Supply and fix in replacement of new compressor hermetically sealed type with suitable rated capacity electric motor and shall be equipped with over load protection, 230 volt, 50 HZ, single phase and confirming to IS-10617, suitable for water cooler 40/60 ltr capacity complete all as specified and directed. Make : KIRLOSKAR/TECHUMSH/carrier/Blue Star/LG
M&L for gas refrigent HCFC-22/R-134a in the sealed system of water cooler any make and capacity after checking the leakage / pressure vacuminising flushing the sealed system including replacement of capilary Tube, Gas filter complete all as specified and directed.
Dismantling the blower moter of water cooler 1/32 HP, 23 W, 1250 RPM capacity, 230 volts single phase and taking out burnt out copper winding wire from moter and M&L for rewinding the electric motor with super enameled copper winding wire of same size and gauge including insulation material, varnish and reassemble and refixing the motor complete including replacement of unserviceable spares all as directed. (Ball bearings,bushes,and moter shafts shall be measured and paid under seperate items)
Supply and fixing in replacement of thermostat switch for water cooler.
Supply and fixing in replacement of starting relay for water cooler.
Supply and fixing in replacement of starting capacitor 40-60 mfd ,230 volt ,50Hz, confirming to IS 2993 for water cooler.
All as per serial item No 48.00 above but for capacity 60-80 MFD.
All as per serial item No 48.00 above but Running capacitor 15 Mfd , 415volt,50Hz .
All as per serial item No 48.00 above but capacitor 10 Mfd , 415volt,50Hz .
All as per serial item No 48.00 above but capacitor 6 Mfd , 415volt,50Hz .
All as per serial item No 48.00 above but capacitor 36 Mfd , 415volt,50Hz .
Supply and fixing in replacement of PVC pipe low density 25 mm dia flexible pipe with two clamp complete & all as specified.
Supply and fixing in replacement PVC connection pipe with brass union of 15 mm bore in both end suitable for water cooler connection of length not less than 450 mm long.
Supply and fixing PVC pipe flexible type 40 mm dia for drain system complete all as specified and directed.
Supply and fixing in replacement of over load protector (OLP) for water cooler of any capacity complete all as specified and directed.
Supply and fixing in replacement of self closing Push cock 15mm bore chromium plated brass heavy duty longthread ( As per sample) complete all as specified and directed.
S&F in replacement of alluminium blade for blower motor of water cooler 40/60/120 Ltrs complete all as specified and directed.
Supply and fixing in replacement blower motor 1/32 HP 230 volt suitable for water cooler complete with base frame/and rubber bush complete all as specified and directed. Make AUE/GE.
Supply and fix water tank gasket for water cooler 40/80 ltr cap.
S&F wiring kit complete for water cooler.
VOLATAGE STABLIZER
Dismantling of voltage stabilizer 5/4 KVA capacity for repairs and re-fixing back to its original position after repair, cleaning, testing, complete all as directed ( Parts to be replaced will be measured and paid separately under relevant items ).
Supply only the following parts for voltage stabilizer 4/5 KVA capacity complete all as specified and directed :-
(a) Main printed circuit board
(b) Auxilary printed board
(c ) Main transformer
(d) Auxilary transformer
(e) High/low cut off relay
(f) Time delay relay
(g) Volt meter 0-300 volt range AC round/square shape,
(h) push button/switch for volt meter.
(j) Indicator lamp.
DESERT COOLER :-
Supply and fixing in replacement of PVC flexible pipe15 mm dia suitable for water distribution system of desert cooler of any size/capacity including elbow and water distributer 3 way as required .
Supply and fixing of submersible pumps 230 volts, single phase for lifting of water as required head and as directed at site in replacement of old worn out unserviceable vertical pump /submerseable pump. Make: Vansal/Usha /crompton
Supply and fixing Kit fan 450 mm sweep, 1400 RPM , 230 Volt AC in replacement of old unserviceable ,worn out Kit fan complete and fixing in desert cooler complete all as specified and directed. Make :- CG/ Bajaj/ Havells/Usha
Supply and fixing in replacement of old unserviceable of Fresh air fan 9" ,900 RPM 230 volt AC, with louver MS nett/Flap type including make hole of required size and making good the disturbed surface complete all as specified and directed. Make : Havells/Bajaj/ Crompton.
Supply and fixing in replacement Exhaust fan 450 mm sweep, 1400 RPM , 230 Volt AC including make hole of required size and making good the disturbed surface complete all as specified and directed. Make : Havells/Bajaj/ Crompton.
Supply and fixing in replacement of front grill plastic of the desert cooler with necessary nut, bolts, and washer etc, all as directed at site.
Supply and fixing in replacement of loose wood wool padding of desert cooler side shutters in wire net complete all as specified and directed.
Supply and fixing in replacement side shutter for desert cooler of 22 gauge PGI sheets grill type complete all as specified and directed.
Supply and fixing the voltage corrector of 4 KVA with over load and time delay relay with correction from 170 to 250 with out put voltage 230 volts all as rquired and directed suitable for fixing on wall complete all as specified and directed. Make: V-Guard / blue bird as approved by GE.
M&L for making water tank and body (Except side shutters)for desert cooler with 22 gauge PGI sheet of suitable size as per sample and directed including dismantling of old unserviceable water tank and body fitted with old desert cooler complete all as specified and directed.
Supply & fixing in replacement of AC/Geyser box by sheet steel enclosure in single pole (SP) and neutral fitted with two pin and earth plug and socket complete with MCB, SP , 240 volts, 20 Amps , 'C' series of suitable rating complete all as specified and directed . Make:- Legrand or equivalent model in Schneider Electric/ L&T as approved by GE.
M&L in repacement of sub main wiring with two run of FR PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 6.0 Sqmm, 1100 Volts grade and one run of 4.00 Sqmm FR PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and drawing in PVC rigid conduit , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed. Note :- 1. Taking down old wiring, two run of single core cable with one run of contineous earth wire of copper conductor wire Flexible (Multistrand) of FR PVC insulated shall be measured and paid as one unit length. 2. PVC conduit pipe with fitting shall be measured and paid separately .
S&F in replacement PVC conduit by Non Metallic Rigid PVC conduit, ISI Marked, conforming to IS 9537, medium grade of size 25 mm dia including all fittings like bends, elbow reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including Cutting & Chasing required on brick wall not exceeding 10 CM girth for concealed conduit wiring and making good to disturbed surface with cement mortar 1:3 and distemper / colour wash etc to match with existing surfaces including facing / finishing complete all as specified and directed.
M/s A S Electrical
VEE KAY ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .