Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹56.6 LAccepted-AOC 18TH FLOOR FL NO 1801 PANCHASHEEL HEIGHT MAHAVEER NAGAR KANDIVALI WEST MUMBAI 400067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L1 | Accepted-AOC L1 | |
| 2 | L2₹58.3 L+₹1.3 L (2.35%)Rejected-Finance B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L2 | Rejected-Finance REJECTED BEING NOT L1 | |
| 3 | L3₹59.9 L+₹2.9 L (5.11%)Rejected-Finance 64 A JASRAJ MANSION 1ST FLOOR OLD HANUMAN LANE KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L3 | Rejected-Finance REJECTED BEING NOT L1 |
Tender Value
₹74.6 L
EMD Value
₹1.4 L
Closing Date
17 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL S P SINGH
CWE AF LOHEGAON, PUNE - 411032
STRUCTURAL REHABILITATION, PLASTERING, REPAIRS OF JOINERY AND VARIOUS OTHER MISC WORKS IN CERTAIN OTM BUILDINGS AT AF STN MADH ISLANDUNDER GE (AF) THANE
2024_MES_674654_1
82672/E8
Open Tender
Civil Works
Item Rate
270 days
GE AF LOHEGAON
As per NIT
6 documents required · 6 mandatory
₹1,000
Yes
GE AF LOHEGAON
₹1.4 L
Yes
27 Jan 2025
14 Sept 2024
24 Oct 2024
14 Sept 2024
17 Oct 2024
5 Oct 2024
Amount
Taking down cement plaster on brick/stone or concrete surface including racking out joints, hacking for key, scrubbing down with water to receive plaster, including removing debris/rubbish materials off the site complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work built in cement mortar including all quoins, arches, pilllars etc. and precast articles including disposal of demolished material complete all as specified and directed.
M &L Brickwork with sub-class `B' brick straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for precast cement concrete block masonry with solid blocks, exc 10 cm in width and and setting in cement mortar (1:6), Type C1 (1:3:6) complete all as specified and directed by Engr - in - Charge.
M&Lfor rendering 15mm thick in cm 1:6 finished with neeru finish as specified on fair faces of brick work /stone or concrete surfaces complete all as specified and directed by Engineer-in-Charge.
M & L for rendering 20 mm thick in cement mortar 1:4 (15 mm thick backing coat and 5mm thick finishing coat) on fair faces of brick work or concrete surfaces including finished even and smooth without using extra cement with using water proofing compound (water proofing compound shall be measured and paid seperately) complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 5 mm thick in cm 1:3 on fair faces of concrete as in soffit/ ceilling or slab, chajjas finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Supply only liquid water proofing compound
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces all as specified and directed by Engineer-in-Charge.
M&L preparing newly plastered surfaces ,and applying 2 coats of Oil Bound Distemper over a coat of alkali resistent primer Over 3 mm thick wall care putty on wallscomplete all as specified and directed by Engineer-in-Charge.
M&L for Preparation of newly plastered surfaces of ceiling and applying two coats of distempering complete all as specified and directed by Engineer-in-Charge.
M&L preparing Old plastered surfaces ,and applying 2 coats of Oil Bound Distemper over 1 mm thick plaster of paris putty on walls complete all as specified and directed by Engineer-in-Charge.
M&L preparing Old plastered surfaces of ceiling and applying 2 coats of Oil Bound Distemper complete all as specified and directed by Engineer-in-Charge.
Removal of existing concrete including loose/weak concrete from the concrete structure i.e. beams/columns/deckslab etc upto beyond corroded steel reinforcements to a depth of minimum 10mm minimum behind the reinforcement by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer, pneumatic chippers including high pressure water jetting and removal of debris. Concrete around the corroded reinforcement shall be removed properly. The edges of the repair locations of concrete should be saw cut to depth of at least 10mm to avoid featheredging and to provide a square edge complete all as specified and directed by Engr-in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
Preparation of surface and removal of rust in the loosely bonded concrete of the RCC deckslab, beam / girder and piles shall be chipped out using the mechanical cutter exposing the bars and applying Rust Remover using small brush and allow to react it for 16- 24 hrs. Before applying protective coating,the surface should be wire brushed and thoroughly cleaned for dust with dry cloth complete all as per manufacturer instructions and directed by Engr- in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for applying two coats of Anti-Corrosive Primer two component (epoxy anticorrosive zinc rich coating) on reinforcement steel surfaces uniformely. Coating shall be applied by the brush to the exposed and cleaned rebars with an interval of 45 minutes to 1 hour @ 40microns DFT / coat and allowed to completely dry for 24 hours complete all as per manufacturer instructions and directed by Engr- in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L preparation of concrete surfaces by removing loose concrete, dust, dirt etc, cleaning the surface properly and applying one liberal coat of epoxy bonding agent ( two component agent) by brush application complete all as per manufacturer instruction and directed by Engr-in- Charge Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L 50mm thick ( average thickness) modified single component, alkaline resistant fibre reinforced, thixotropic, cementitious patch repair mortar on conrete structure. Applying the mortar arround the reinforcement and finishing to bring it in line with existing concrete surface complete all as per manufacturer instructions and directed by the Engr-in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for holes of dia 16mm and depth 100 mm drilled @ a spacing of 1mtr c/c both ways on the existing structure .The loose cementitious particles are removed using a air blower to clean the holes.Shear Keys of dia 10mm cut from HYSD rebars are anchored into these holes of depth 75mm and bent out to an equal length of 75mm using Resin Anchor Grout complete all as per manufacturer instructions and directed by the Engr-in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
Providing & executing injection/pressure grouting in the cracks in the parent concrete by fixing PVC/Aluminium nipples at 150mm to 200mm distance or specified distances as per design and detailed specifications. Pressure grouting using low viscous epoxy grout. Moisture insensitive epoxy resin injection material supplied in 1.5 Litre pack which can grout gaps ranging from 0.25mm to 9mm, having mix density 1060 Kg/m3, compressive strength 60 N/mm2, Tensile Strength 20 N/mm2, Flutural strength 45 N/mm2. Pressure grouting shall be carried out after surface preperations includes fixing nipples and filling cracks with epoxy mortar one day before grouting, injecting low viscous grout mechanically about pressure 3.5-7.0 Kg/Cm2, removing nipple after grouting and sealing with epoxy mortar etc complete as directed by Engr - in - Charge. Payment shall be made on actual grout consumed. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
Providing and applying avg 25mm thick sand faced plaster on external walls of building wherever required which include cleaning the surface, preparing plaster mix in cement mortar in ratio 1:4 (cement : sand) admixed with integral water proofing admixture based on lignosulphates having chloride content as per IS 2645 - 2003 mixed as per manufacurers instructions per bag of cement, levelling and finishing to match existing plaster etc as per directions of Engr - in - Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for micro concrete to existing concrete structure including proper tight leak proof shuttering SPL polimer modified cementitious ,low permeable'free flow 'non shrink 'self compacting micro concrete shall be grade M70 as per recommended w/c ratio and pouring as per the required thickness complete all as per manufacturer instructions and directed by Engr- in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Dismantling floor hearth or wall tiling including cement morter bedding (but not backing) and rubbish off the premises.
Excavating over areas, n exc 1.5 m deep and getting out in Hard/dense soil
M & L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering
M & L Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
M & L Cement concrete in foundations, filling and mass concrete Type D2 1:4:8 (40 mm graded aggregate)
M&L Vitrified tiles 600x600x10mm thick polished, in floors etc set and jointed in neat cement slurry and pointed in white or coloured to match over & including 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engineer-in-Charge..
M&L Vitrified tiles 600x10x10mm thick polished, in floors etc set and jointed in neat cement slurry and pointed in white or coloured to match over & including 10mm thick backing coat in CM 1:4 complete all as specified and directed by Engineer-in-Charge..
M&L Coloured Glazed Ceramic tiles 200x300 or 250 x 350 or 300 x 450 and 6-7mm thick on vertical surfaces such as skirting, dados and risers to steps etc including 10mm thick backing coat in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L non skid ceramic tiles(Coloured) 7 to 8mm thick (square/rectangular) area of each tile exc 0.06sqm but n.exc 0.11 sqm, in in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including screed bed 15mm thick in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M & L for Taking up or down steel tubing and connections 20mm bore, including cleaning for re fixing or removal to store
M & L for Taking up or down steel tubing and connections 15mm bore, including cleaning for re fixing or removal to store
M & L for Refixing old steel tubing and connections 20 mm bore in new or old position (Walls, ceiling, floors, etc.
M & L for Refixing old steel tubing and connections 15 mm bore in new or old position (Walls, ceiling, floors, etc.
S&F GI tubing medium grade including all fittings fixed in floor /walls/ ceilling etc 20mm dia bore. Note : The rates includes necessary cutting through walls, floors, ceiling etc for concealing as reqd and as directed by Engr-in Charge.
S&F GI tubing medium grade including all fittings fixed in floor /walls / ceilling etc,15mm dia bore. Note : The rates includes necessary cutting through walls, floors, ceiling etc for concealing as reqd and as directed by Engr-in Charge.
S&F in repair Stop valves, cast copper alloy,screwed down, high pressure, but fancy type, chromium plated with long shank and cup (concealed type) screwed both ends for iron pipe or for unions and fixed all as specified and as directed
S&F in repair bib taps fancy type cast copper alloy chromium plated with butterfly handle, screwed down, screwed for iron pipe or for brass ferrule 15mm bore all as specified.
S & F Soap dish, any type, fixed to plugs with chromium plated brass screws
S&F in repair PVC connection with brass socket on both side 60cm for 15mm dia pipe.
S&F PVC, low level flushing cistern with complete fitting incl float valve flush pipe bracket for flush etc 10.0 ltrs capacity in repairs.
S&F in repairs gratings square 150 mm size of PTMT (min wt 100 gm)
S&F in repairs aluminium powder coated decorative draphery rod 20 to 25mm dia
S&F in repairs aluminium powder coated brackets suitable for decarative draphery rods 20 to 25mm dia
S&F in Repair victerous China squatting pan ' orrissa pattern ' size 580 x 440mm white with intergal foot rest etc complete all as specified and directed by Engg-in-Charge.
S & F in repairs Vitreous China wash basin, angle back, size 600x480mm white, excluding taps, waste, chain and plug and porcelain stopper but including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe
S&F wash down water closet (pedestal pattern/white fixed in repairs Excluding flushing cistern & flushing pipe) complete with & including connecting to drain pipe etc complete all as specified and as directed by Engineer-in-Charge
S & F Fancy type Pillar taps 15 mm bore, cast copper alloy, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed all as specified and as directed
S&F in repairs ball brass valve, high pressure, with ploythene float and flynut complete, screwed for iron pipe or brass ferrule 20 mm bore.
S&F in repairs Rotational moulded polyethylene water storage tanks (cylindrical verticalwith closed top) with 1000 litre capacity hoisted and fixed in position all as specified in SSR Part I
S & F in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of 20mm bore
S & F in repairs health faucet PTMT including long pvc connection all as specified and directed suitable for 15mm bore pipes and fittings.
S&F in repairs Angle stop valve 15 mm dia of PTMT any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms).
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed by Engineer-in-Charge.
S& F mild steel confirming to FE-290(Gde-E-165),(Flat sections) as in wind ties and similar work including cutting to required length nothing ,drilling,fitting , connecting with nuts bolts and fixed in true position complete all as specified and as directed by the Engineer in charge.
S & F Plates( Plain or chequered ) of Fe-410-W (Gde-E-250) Quality -B channels,square cut or notched (ordinary and counter sunk) forming holes, without any attachment.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roofcoverings
S&F Pre-painted galvalume aluminium zinc coating (PPGL) based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in roof covering fixed with self tappping screws as specified.
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed
M&L for preparation of new surfaces of steel of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc Chrome primer.
S&F aluminum powder coated( of approved colour) any track sliding windows with aluminum sections mentioned in catalogue of approved manufacturer including suitable Nylon beading, channel gasket, nylon rollers, star lock with handle with complete fittings including water tightening using silicon compound all around etc complete all as specified and as directed.
Taking down the unserviceable Aluminium glass door shutter of any size and description and refixing the same after resecuring the shutter by using aluminium 'L' section at the joints and refixing the glass in the shutter complete all as specified and directed (Note : All accessories required for repairs shall be measured seperately under other respective items)
Taking down aluminium sliding windows of any description and any size and replacing the wornout, broken wiremesh, aluminium sections, glass grill, rubber beading, rollers, locks etc as required and refixing back into the same opening for easy movement of shutters including necessary fittings and fixtures (Note : Items such as i) Wiremesh, ii) Glass, iii) Grill, iv) Rubber beeding, v) Rollers, vi) Locks, vii) Aluminium sections etc will be paid seperately under respective items as supply only)
Supply only ordinary sheet glass 4.8mm thick in square exc 0.5sqm in each panes.
Supply only Galvanised steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm for aluminium windows and ventilators
Supply only PVC Star lock for Aluminium windows.
Supply only Nylon / PVC Rollers for Aluminium Windows.
Supply only Rubber beeding suitable for aluminium door/window shutters.
S&F double action floor spring hydraulically operated made up of miniumum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass other parts made of mild steel heavy duty.
S&F aluminium anodised lourvered (fully louvered type), aluminium section mentioned in catalogue 100mm wide heavy duty aluminium blades with 5mm thick frosted glass, lever handle, lock including water tighting using silicon compound etc. complete all as specified/directed
M&L for machine cut cuddappa stone slab 20 to 25 mm thick as in cills/jambs of window & door openings, set jointed and pointed in neat cement slurry with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing complete including 15mm thick backing coat in cement mortar 1:4
M & L Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite.
S&F aluminum anodised frame powder coated( of approved colour) for doors, windows, ventilators with one or more rebates including joining cleat (min powder coating 50 micron) any track sliding windows/ Doors/Partition frames with aluminum sections mentioned in catalogue of approved manufacturer including water tightening using silicon compound all around etc complete all as specified and as directed by Engr - in- Charge. (Note : Glass, wire cloth shall be measured under respective items)
S&F powder coated of approved colour aluminium grill of 4mm x 6mm bars size of opening 10 cms size mesh RG 103 (as per Royal grill drg attached) with aluminium channel 'F' angle 20mmx15mm aluminium frame work all as directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets all as specified and as directed
M & L 12mm thick Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish (Frame work for ceiling shall be measured and paid separately)
S & F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre.
S & F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long 12.5mm dia. 40mm long complete all as specified
Taking down Shutters exc 1 sq. m and n exc 2 sq. m each all as specified and directed by Engr-in-Charge
S&F 150mm long Aluminium handles, cast type, anodised all as specified and directed byEngr-in-Charge.
S&F 100mm long Aluminium handles, cast type, anodised all as specified and directed byEngr-in-Charge.
S& F 100mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 all as specified and directed by Engr-in-Charge.
S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed all as specified and directed by Engr-in-Charge.
S&F 150mm long Aluminium anodised, barrel tower bolts of ex- truded section and fixed all as specified and directed by Engr-in-Charge.
S&F 100mm long Aluminium anodised, barrel tower bolts of ex- truded section and fixed all as specified and directed by Engr-in-Charge.
S&F in repairs Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples all as specified and directed by Engr-in-Charge.
Taking down chowkhats or frames n.exc 1.5 Sqm each with shutters (without taking off shutters from the frames)
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing
S&F 30mm thick 2nd class hard wood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats
S& F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed by Engr-in-Charge.
M&L for 32mm, Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed
S & F Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union
S&F in repair Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms)
S&F repair Shower arm 15 mm size, 195mm long with bend of 45degree with flange of PTMT any colour.(Minimum weight 40gms
S&F repair Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms)
S&F in repair Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms)
S&F in repair 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors
S&F in repair Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof
S&F in repair PVC (SWR) bends 75 mm bore
S&F in repair PVC (SWR) bends 110 mm bore
S&F in repair PVC (SWR) 'S' trap 110mm bore
S&F in repair 110mm PVC (SWR) WC connector bent type
S&F in repair Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4)
S&F in repair Cast iron nahani trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4)
S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement
Taking down chowkhats or frames exc 1.5 Sqm but n.exc 4.00 Sqm each with shutters (without taking off shutters from the frames)
S&F powder coating (powder coating thickness 50 micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
S&F Powder coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified.
S&F for ordinary sheet glass 4.8mm thick and glazing with oil putty/beddings in square exc 0.5 sq, in each panes
S&F in repairs 12mm thick Prelaminated particle board, interior grade, prelaminated both sides with decorative choice lamination , fixed with screws to timber frame work
S& F in repairs Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed
M & L for preparation of old treated steel surfaces of any description over 10 cm width & girth not otherwise described and applying two coat of epoxy paint over a coat of primer complete all as specified and directed.
Taking down carefully point wiring and removing from site such as (Light,fan socket or power) Complete including fitting and fixtures,fan regulators switch boards,switches,ceiling rose's lamp holder from existing batten PVC conduit/steel conduit wiring complete excluding light fittings and fans all as specified and making good to the disturbed surfaces to match with existing ,complete all as specified and as directed
M & L for concealed conduit point wiring complete for light/ fan on independent /combine board with cable 1.5 sqmm (Nominal area) FRLS PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC Concealed conduit pipe medium grade 20 mm dia, pipe hooks , elbows, juction covers and junction boxes , after cutting in wall chasing for conduits and sinking's for sunken cast iron/ pressed steel terminal boxes suitable length and thickness for mounting, switches, sockets,fan regulator with 3 mm thick plastic laminated sheet cover fixed with cadmium plated machine screws and cup washers, duly grouting and painted with red oxide metal primer and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor along with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switch and connected to common earth dolly, complete all as specified and direced
Ditto all as per Srl item No -119.00 above but for one socket outlet 5/6 amp on independent board complete all as specified and directed
Ditto all as per Srl item No -119.00 above but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed
Ditto all as per Srl item No -119.00 above but for one switch socket combinationt 6 pin 6/ 16 Amps on independent board with copper conductor 2.5 Sqmm complete all as specified and directed
Ditto all as per Srl item No -119.00 above but for call bell point complete all as specified and directed
S&F Switch piano, flush type single pole, one way 5 Amp complete all as specified complete all as specified and directed
S&F Switch piano, flush type single pole, one way 16 Amp complete all as specified and directed
S&F Socket outlet 2 in 1, 5 pin, 5A complete all as specified and directed
S&F Socket outlet 2 in 1, 6 pin, 6/16A flush type complete all as specified and directed
Supply and fix in replacement industrial socket metal clad plug and socket with MCBs single pole 20 Amp complte all as specified and directed
S&F bell push flush type 5 Amp complete all as specified and directed
S & F stepped type,single socket fan regulator for ceiling fan 1200/1400mm sweep complete all as specified and directed
S&F Electronic bell AC 230 Volt single pole ding dong type complete all as specified and directed
S & F ceiling rose surface bakelite three terminals complete all as specified and directed
Taking down carefully existing serviceable LED Tubelight/ bulkhead/ security light/ recess mount fitting of any size and refixing the same to respective location after carrying out cleaning all the components of fittings, including replacement of nuts, bolts and connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed
S & F in replacement LED Tubelight fitting with polycarbonate housing and integrated electronic driver, 20 watt having input voltage AC90-300V, 50 Hz , 6500K, surge protection min 4 KVA and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed
Supply and fixing LED building security light fitting 35 Watt 230 V, surge protection 10 KVA, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.& Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 1 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed
S & F in replacement LED Water tight bulk head fitting 10 W,comprision of connector galvanised cast iron back plate,weather proof enamelled gallery ,glass well,and including 10 watt LED all as specified and directed
S & F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. all as specified.
S & F in replacement angle holder insulated body with back plate for conduit fittings complete all as specified and directed
S&F LED lamp 9W for angle holder complete all as specified and directed
S & F in replacement for Sub Main wiring with two single core 6 Sqmm PVC insulated FRLSH multistranded flexible copper conductor cable 660/1100 volts grade drawn in through flexible non metallic PVC casing caping conduit with and including PVC insulated 6 Sqmm multi strand copper conductor as continuous earth wire in green colour connected to common earth dolly ,complete all as specified and as directed (Note : PVC cable and PVC casing caping shall be ISI marked) Note :- Two length of 6 Sqmm cable and one length of 6 Sqmm earth cable along with PVC casing caping will be measured as one running length
S & F in replacement for Sub Main wiring with two single core 4 Sqmm PVC insulated FRLSH multistranded flexible copper conductor cable 660/1100 volts grade drawn in through flexible non metallic PVC casing caping conduit with and including PVC insulated 4 Sqmm multi strand copper conductor as continuous earth wire in green colour connected to common earth dolly ,complete all as specified and as directed (Note : PVC cable and PVC casing caping shall be ISI marked) Note :- Two length of 4 Sqmm cable and one length of 4 Sqmm earth cable along with PVC casing caping will be measured as one running length
S & F in replacement sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted Vertical TPN 4 ways, 415 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof , IP42 and above suitable for incorporation MCBs and isolators etc including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed
S & F in replacement sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 4 ways, 240 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof, IP 42 suitable for incorporation MCBs and isolators etc including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed
S & F in replacement sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 8 ways, 240 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof, IP 42 suitable for incorporation MCBs and isolators etc including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed
S&F in replacement MCCB TP&N 63 Amps with breaking capcity 16kA ,Fixed TM and 415 volts AC Supply ISI marked complete all as specified and directed
S & F in replacement MCB ‘B’ series type suitable for 240 volts, AC supply 6 to 32 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed
S & F in replacement MCB ‘B’ series type suitable for 240 volts,10 KA, AC supply 6 to 32 Amps , single pole (SP) with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed
Disconnecting electric connection and taking down carefully serviceable ceiling fans and exhaust fan and keep in safe custudy. After the building repair work or as directed refixing /hanging the ceiling fan and exhaust fan including electric connection with and including new flexible sheathed copper wire 3 core from ceiling rose/connector to fan connector, including in replacement new nut bolts, rubber reel, capacitor 2.5mfd, machine screws and split pins etc including painting the ceiling fan and exhaust fan complete body with blades, canopies, down rod etc. with synthetic enamel paint by spray gun after scraping down old paint in colour as directed complete all as specified
S&F ceiling fans AC single phase 230/240 V of size 1200 mm sweep without regulator having Min air delivery 210 CFM with service value 6.00 BEE 5 star rated with brushless direct current motor (BLDC) complete with electrical connection providing three core round flexible copper conducter cable of suitable size complete all as specified and directed MAKE: Orient electric 1200mm hector 500. Havells effeciencia neo 1200mm, Cromption Energin HS.
S&F Heavy duty metal body exahust fan of 300mm sweep ,240 volt,copper winding, complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to distubed wall in cement mortar (1 :4) white washing matching with existing colour etc.
S&F exhaust fan made of sturdy engineering plastic of 250mm sweep ,240 volt, complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to distubed wall in cement mortar (1 :4) white washing matching with existing colour complete all as specified and directed
Material and labour for lowering of LED light fiitings mounting ring 20 Mtr to 30 Mtrs height carefully with help of highly skilled electrician and labours to mannually/electrically, Servicing Repair and replacement of spares of forward/reverse operation induction motor 3 phase 415 volts 2 HP capacity including greasing and oiling. Servicing of forward/reverse operation Gear box including greasing and oiling, dismantling and taking chain of motor to gear box, taking down unserviceable LED Light fittings and replacement of Suitable drivers of existing capacity/ Make its serviceable,supply and replace wire rope for lift side for suitable gauges/size,replacement of timer with power contactor three phese 415 volts AC 32 Amps capacity, After repairing of LED light fittings tesiting and make serviceable of all fittings and lifting of mounting rings to existing places, After repairing of LED light fittings tesiting and make serviceable of all fittings and lifting of mounting rings to existing places complete all as specified and directed
Supply & Fix LED flood light fitting 200 Watts Pressure die cast aluminium housing, heat resistant toughened glass with frame, IP66 protection better optics for uniform distribution, complete all as specified and as directed
Supply and fixing in repairs/Replacement of LED driver for 1x200 watt LED flood light complete all as specified and directed
Dismantling and Taking down L.T. under ground armored PVC/XLPE insulated and PVC/XLPE sheeted heavy duty 1100 Volts grade under ground cable of any size complete all as specified and directed.
Taking out serviceable unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm during excation of trenches and relaying after cable laying in trenches all as specified and directed
M & L for excavation in trenches not exceeding 1.5 m wide and not exe 1.5 M in depth and getting out in hard/dense soil complete all as specified and directed .
M & L for Returning filling in including spreading leveling, watering and well ramming in layers not exe 25 cm each layer complete all as specified and directed.
M & L for Removing excavated material to a distance not exe 50 M and depositing where directed not exceeding 1.50 M above the starting point complete all as specified and directed.
Supply and spreading in trenches clear dry sand for cable protection and punning down gently 10 cm below the cable and 15 cm above the cable all as specified. Note :- Punning thickness only measured.
Supply and laying unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 ISI marked flat size 250x150x40 mm laid in trenches as specified and as directed.
M&L for cutting existing road/hard standing not exc 50x60 cm in wide & depth getting out excavated material for laying GI tube , for passing through LT cable, returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:1.5:3; including removal of surplus soil complete all as specified and directed
Supply and lay jointing and testing and commissioning in replacement of 16 Sqmmx4 core XLPE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed
M & L for Earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of plate not less than 1.5 Mtr below ground level , connecting to GI earth lead 4 mm dia GI earth wire ,by means of bolts,nuts and washers of GI and protection by provision of GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20 mm grade stone aggregate with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 gs /Sqmm ) and frame of angle iron 25mmX25mmX6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape ,GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed ontop edge of earth plate common salt and charcoal filling test point made out of 40 mmX 8 mm FI with fixing arrangement ,funnel, wire mesh and earth work inhard dense soil ,returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electric plate no.3 of SSR part 1 and connecting to earth test point including taking out unserviceable earthing with all acessories all as specified or indicated including testing on completion all as specified and directed
Supply and lay GI pipe 40 mm light grade for cable protection in walls trenches or any situation including clamp nut bolt etc complete all as specified and directed
Supply & fixing LED land scape light/bollard light 10W/9 W with 900mm height extruded aluminium cylindrical section housing IP-65 rated complete with base & log bolt grafite grey epoxy cationic powder coated all accessories including PCC foundation for fixing arrangement on ground complete all as specified. and directed .
M&L for steel water tubing medium grade of size 25 mm bore with all fittings laid in trenches or fixed to wall or floor.complete all as specified and directed
M&L for steel water tubing medium grade of size 40 mm bore with all fittings laid in trenches or fixed to wall or floor.complete all as specified and directed
M& L Cutting existing steel tubing for alterations or additions 40m or 50 mm size , Add if necessarily done in position without taking down.
S & F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe 25 mm and fixed complete all as specified and directed
S & F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe 40 mm and fixed complete all as specified and directed
Vishal Builders (BID ID -3135351)
M/s Mukesh Engineers (BID ID -3135423)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .