Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹81.5 LAccepted-AOC 205 IIND PHASE INDUSTRIAL AREA BARMER 344001 | BARMER | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹84.9 L+₹1.9 L (2.26%)Rejected-Finance S O KALA RAM C O LALIT AND BROTHERS UTARLAI UTTARLAI VPO UTTARLAI BARMER RAJASTHAN 344001 | BARMER | RAJASTHAN | 344001 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹88.0 L+₹5.0 L (6.02%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹88.7 L+₹5.7 L (6.87%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹90.0 L+₹7.0 L (8.48%)Rejected-Finance 224 OFFICERS ENCLAVE BEHIND PLV MEMORIAL COLLAGE SHIKARGARH ARMY AREA JODHPUR RAJ 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹94.9 L
EMD Value
₹1.7 L
Closing Date
13 Jul 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (A) Jaisalmer
HQ CWE (A) JAISALMER 345001 (Raj)
ADDN / ALTN OF SELECTED OLD MD ACCN AT JALIPA MIL STN UNDER GE(A) BARMER
2024_MES_656591_1
84183/E8
Open Tender
Civil Works
Item Rate
270 days
BARMER
AS PER NIT
8 documents required · 8 mandatory
₹1,000
GE ARMY BARMER
₹1.7 L
Yes
10 Sept 2024
29 May 2024
15 Jul 2024
29 May 2024
13 Jul 2024
29 Jun 2024
29 May 2024 - 7 Jun 2024
Amount
B&R WORK Taking down cement plaster of any description, any thickness from surfaces of walls/soffits of roof projections & chajjas /ceilings etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm thick in CM (1:6) on on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing surfaces, trowelled to even and fair finish without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for 2.0mm thick wall care putty on wall complete all as specified and directed by Engineer-in-Charge.
M&L for preparing new plastered or unplastered surfaces of walls, and applying two coats of oil emulsion distempering over a coat of interior wall primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered or unplastered surfaces of walls, and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment, plastered or unplastered old surfaces of walls, including filling of cracks/holes by crack filler, removing unnecessary nails applying two coats of oil bound distemper/emulsion over a coat of interior wall primer including and over 2mm thick wall care putty complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment, plastered or unplastered old surfaces of walls, including filling of cracks/holes by crack filler, removing unnecessary nails and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 5mm thick in CM (1:3) as on concrete/brick surfaces in ceiling finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for 2.0mm thick wall care putty on ceiling complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered or unplastered surfaces of ceiling, and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered or unplastered surfaces of ceiling, and applying three coats of white wash preparation complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment, plastered or unplastered old surfaces of ceiling, including filling of cracks by crack filler, removing unnecessary nails and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm thick in CM (1:4) with using WPC on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing surfaces, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. Note : WPC shall be measured and paid separatley under relevant item.
M&L for preparation of new plastered surfaces of walls and applying two coat of cement based paint over a coat of external primer complete all as specified and directed by Engineer-in-Charge.
M&L for Complete removal of existing treatment surfaces of walls and applying two coats cement based paint over a coat of external primer complete all as specified and directed by Engineer-in-Charge.
Supply only integral liquid water proofing compound complete all as specified and directed by Engineer-in-Charge.
S&F chicken wire mesh 22 gauge of size not less than 20X20mm complete all as specified and directed by Engineer-in-Charge. Make : Swastik or equivalent make as approved by GE.
Demolition of stone slabs and tiles laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed by Engineer-in-Charge.
M&L for Vitrified ceramic tiles dark shade 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM (1:4) complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 19.00 above but in skirting over 10mm thick backing coat in CM (1:4) complete all as specified and directed by Engineer-in-Charge.
M&L for Glazed ceramic tiles of size 350mm x 250mm x 7mm/ 450mm x 350mm x 7mm thick (coloured) of superior quality fixed on vertical surfaces such as skirting/dado etc, set and jointed in neat cement slurry over 10mm thick backing coat in CM (1:4) and pointed in coloured cement to match complete all as specified and directed by Engineer-in-Charge.
M&L for non skid ceramic tiles of size 7 to 8mm thick (coloured) (Square/rectangular) area of each tile exc 0.06 but not exc 0.11 sqm, in floors, set & jointed in neat cement slurry and pointed in coloured cement over 15mm thick screed bed in CM (1:4) complete all as specified and directed by Engineer-in-Charge.
M&L for non skid ceramic tiles of size 7 to 8mm thick (coloured) (Square/rectangular) area of each tile exc 0.18 but n exc 0.38 sqm, in floors, set & jointed in neat cement slurry and pointed in coloured cement over 15mm thick screed bed in CM (1:4) complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 23.00 above but in skirting over 10mm thick backing coat in CM (1:4) complete all as specified and directed by Engineer-in-Charge.
M&L for 30mm thick PCC 1:2:4 Type B1 using 20mm graded stone aggregate as in levelling course in floor complete all as specified and directed by Engineer-in-Charge.
M&L for Kota stone slab 20-25mm thick (in single piece as vertical support and horizointal base for granite top) in cooking platform, jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete complete all as specified and directed by Engineer-in-Charge.
M&L for Machine cut kota stone slab flooring 20-25mm thick over and including screed base 15mm thick in CM (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab inclunding rubbing and polishing complete all as specified and directed by Engineer-in-Charge.
M&L for Kota stone slab 20-25mm thick (in single piece) in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab inclunding rubbing and polishing including backing coat 10mm thick in CM (1:4) complete all as specified and directed by Engineer-in-Charge.
M&L for 20mm thick Granite (of any type in single piece) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engineer-in-Charge.
M&L for 20mm thick Granite (of any type in single piece) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engineer-in-Charge.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed by Engineer-in-Charge.
M&L for 300mmx300mmx10mm thick non skid polka dots endura floor paver tiles with grey cement and pigment, over and including 15mm thick screed in CM (1:4), set jointed & pointed in neat cement slurry in floors complete all as specified and directed by Engineer-in-Charge.
S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste pipe; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer-in-Charge.
Taking down shutters of any description exc 1 sq.m and n exc 2 sqm each complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames (without taking off shutters from the frame) n. exc 1.5 Sqm complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm complete all as specified and directed by Engineer-in-Charge.
M&L for Pressed steel frames size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed by Engineer-in-Charge.
M&L for Pressed steel frames size 165x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed by Engineer-in-Charge.
S&F for 35mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed by Engineer-in-Charge.
S&F for 2nd class HW glazed & skeleton shutter 35mm thick factory made open rebated & prepared to receive glass gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass,gauge etc size of members of shutter as specified in SSR part-I , section 8, clause 8.24 (a) complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of New or previously untreated wood and wood based surfaces of any description over 10cm in girth or width and painting with two coats of synthetic enamel paint over a coat of primer complete all as specified and directed by Engineer-in-Charge.
S&F for Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer-in-Charge.
S&F for Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.). hinges type B-21 100mm long (2 No.) suitable handle (1 No.) complete all as specified and directed by Engineer-in-Charge.
M&L for Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and complete all as specified and directed by Engineer-in-Charge.
S&F for Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed by Engineer-in-Charge.
M&L for aluminium work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions complete all as specified and directed by Engineer-in-Charge.
S&F for Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed by Engineer-in-Charge.
M&L for 4.8mm thick sheet glass, ordinary quality and fixed with glazing clips, rubber packing in square in n exc 0.5 sq.m in each pane in each pane complete all as specified and directed by Engineer-in-Charge.
S&F for stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire stapples complete all as specified and directed by Engineer-in-Charge.
S&F for PVC door frames of sizes 50 x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS Square tube in opening of suitable size complete all as specified and directed by Engineer-in-Charge.
S&F Factory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick with particle board core (stile:), with 2,4 or 6 raised panel design with 5mm thick Moulded PVC Sheet on the front Face & 2mm Plan colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed by Engineer-in-Charge.
M&L cement concrete 1:2:4 type B-1, using 20mm graded stone aggregate as in holdfast blocks/ filling in chowkats complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete (1:5:10) type E2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) as in plinth protection including making joint at every 2.5mtr interval and at corner and filled with mixture of bitumen and sand and finished even and fair and laid in alternate bays complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge.
S&F Mild steel as hold fasts Fe.290.Gde-E-165 complete all as specified and directed by Engineer-in-Charge.
S&F 100mm long butt hinges medium weight cold rolled mild steel complete all as specified and directed by Engineer-in-Charge.
S&F 75mm long butt hinges medium weight cold rolled mild steel complete all as specified and directed by Engineer-in-Charge.
S&F aluminium floor door stoppers double legged length 140mm with hard drawn steel spring fitted in floor complete all as specified and directed by Engineer-in-Charge.
S&F 150mm long Aluminium anodizes barrel tower bolts of extruded section complete all as specified and directed by Engineer-in-Charge.
S&F 150 mm size aluminium anodized handle complete all as specified and directed by Engineer-in-Charge.
S&F 100mm long Aluminium anodizes barrel tower bolts of extruded section complete all as specified and as directed.
S&F 100 mm size aluminium anodized handle complete all as specified and directed by Engineer-in-Charge.
M&L for 300mm long aluminium alloy anodized sliding door bolts with Hasp and staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed by Engineer-in-Charge.
S&F mild steel ordinary rat tail rod pattern spring 300mm size including roller & roller plate and incl welding complete all as specified and directed by Engineer-in-Charge.
S&F Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed by Engineer-in-Charge.
S&F magnet catches suitable size with striking plate for closing of cupboard shutters complete all as specified and directed by Engineer-in-Charge.
Dismantling of boarding any description fixed in any position with nails complete all as specified and directed by Engineer-in-Charge.
S&F 18mm thick MDF prelaminated board, prelaminated one side with decorative choice lamination matt finish & other side balancing white lamination fixed with screws as in cupboard shutters of bed room, kitchen and internal shelves, kitchen cabinets, partitions and drawers of any size complete all as specified and directed by Engineer-in-Charge.
M&L for Prelaminated particle board of 18/19mm thick, interior grade prelaminated one side with decorative choice lamination & other side balancing white lamination with teak wood leaping fixed with screws as in cupboard shutters of bed room, kitchen and internal shelves complete all as specified and directed by Engineer-in-Charge.
M&L for kitchen baskets with 4mm dia 100 % stainless steel, non - magnetic, multilayer chrome plated, argon welded, double sealed ball bearing mechanism capable of holding plates, cup, saucers, bowls and dongas with 470x485x200 mm of carcass including moving drawer channels complete all as specified and directed by Engineer-in-Charge. Make : Prod code No. 5904 of Godrej or equivalent make and model in Hettich/Lifetime ISI marked as approved by GE.
M&L kitchen baskets with 4mm dia 100 % stainless steel, non - magnetic, multilayer chrome plated, argon welded, double sealed ball bearing mechanism capable of holding plates, cup, saucers, bowls and dongas with 470x485x150 mm of carcass including moving drawer channels complete all as specified and directed by Engineer-in-Charge. Make : Prod code No. 5903 of Godrej or equivalent make and model in Hettich/Lifetime ISI marked as approved by GE.
M&L for Cup and Saucer Basket with 4mm dia 100 % stainless stee , non - magnatic, multilayer chrome plated, argon welded, double sealed ball bearing mechanism capable of holding plates, cup, saucers, bowls and dongas with 420x485x100 mm of carcass including moving drawer channels complete all as specified and directed by Engineer-in-Charge. Make : Prod code No. 6130 of Godrej or equivalent make and model in Hettich/Lifetime ISI marked as approved by GE.
M&L for Perforated Cutlery Basket with 4mm dia 100 % stainless steel, non - magnatic, multilayer chrome plated, argon welded, double sealed ball bearing mechanism capable of holding plates, cup, saucers, bowls and dongas with 420x485x100 mm of carcass including moving drawer channels complete all as specified and directed by Engineer-in-Charge. Make : Prod code No. 6133 of Godrej or equivalent make and model in Hettich/Lifetime ISI marked as approved by GE.
S&F for Thali-Plate Basket baskets with 4mm dia 100 % stainless steel, non - magnatic, multilayer chrome plated, argon welded, double sealed ball bearing mechanism capable of holding plates, cup, saucers, bowls and dongas with 420x485x200 mm of carcass including moving drawer channels complete all as specified and directed by Engineer-in-Charge. Make : Prod code No. 6138 of Godrej or equivalent make and model in Hettich/Lifetime ISI marked as approved by GE.
S&F for Triple corner glass shelf with 4mm dia 100 % stainless steel, non - magnatic, multilayer chrome plated, argon welded for optimum utilization of unbuilt space and convenience of handling frequently used goods complete all as specified and directed by Engineer-in-Charge. Make: Life time / Home care / Silkmove/ Hettich or equivalant ISI marked as approved by GE..
S&F for Tie Holder Pullout size 18 " with 4mm dia 100 % stainless steel, non - magnatic, multilayer chrome plated, argon welded complete all as specified and directed by Engineer-in-Charge. Make: Life time -code : THPO or equivalant make ISI marked as approved by GE.
S&F for Hook Rail Pullout size 18 " with 4mm dia 100 % stainless steel, non - magnatic, multilayer chrome plated, argon welded complete all as specified and directed by Engineer-in-Charge. Make : Life time / Home care / Silkmove/ HETTICH or equivalent ISI marked as approved by GE.
S&F width of flaps (When open) in 30 mm continuous (piano) hinges, mild steel, bright finish or electro galvanised complete all as specified and directed by Engineer-in-Charge.
S&F in repair 25mm dia fancy stainless steel curtain rod with fancy fixing brackets, fancy stops/supports, rollers etc. complete all as specified and directed by Engineer-in-Charge.
S&F in repair vitreous china wash down water closet pan (pedestal pattern), white including connection to drain (or outgoing pipe) and to flushing pipe with and including flush pipe and plastic water closet seat, white closed pattern with flat bottom, cover and mild steel hinges device complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC valveless flushing cistern, low level white with inlet ball valve float and handle including brackets complete fixed capacity of flush 10 ltrs complete all as specified and directed by Engineer-in-Charge.
S&F in repairs wash hand basins, vitreous china,of size 550x400mm (flat back, or angle back type) including cutting for and pinning in ends of brackets or erecting stand inclusive of fixing of supply and including waste pipe etc complete all as specified and as directed.
S&F in repairs CP wall mixer for mixing (HOT/COLD) bathroom water, with wall cap of CP Brass, screwed down, screwd for iron pipes 15mm bore complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 15mm bore pillar taps, cast copper alloy with capstan heads, chromium plated,fancy type screwed down high pressure with or without lettered “HOT” or “COLD” with long screwed shanks and fly nuts complete all as specified and directed by Engineer-in-Charge.
S&F in repair brass CP wash hand basin mixer fancy type single lever without poput waste system with 450mm long braided hoses with necessary fixing arrangements complete all as specified and directed by Engineer-in-Charge. Make : Model No. FLR-5001B of JAQUAR make or equivalent model in Kolher/ Grohe as approved by GE.
S&F in repair brass CP sink mixer fancy type with regular spout with necessary fixing arrangements complete all as specified and directed by Engineer-in-Charge. Make : Cat No. 7655 of Prayag or equivalent model in Cera/ Jhonson/Hindware as approved by GE.
S&F in repair brass CP wall mixer fancy type with telephonic shower arrangement, connecting legs and wall flanges but with out crutch and telephone including necessary fixing arrangements complete all as specified and directed by Engineer-in-Charge. Make : Model No. QQT-7217 of JAQUAR make or equivalent model in Kolher/ Grohe as approved by GE.
S&F in repair 15mm bore Bib taps CP fancy type, cast copper, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15mm bore, 450mm long, PVC connections with brass unions internally threaded both ends complete fixed to iron pipe at both ends as fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repair CP fancy type stop valves ,cast copper alloy, screwed both ends for iron pipe or for union of 15mm bore complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 15mm bore stop valves ,cast copper alloy, chromium plated with long shank and cup (concealed type) complete all as specified and directed by Engineer-in-Charge.
S&F in repair 1.0m length Hand faucet MS chromium plated with hanging device fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repair 1.0m length Jet water spary including MS chromium plated hanging device complete all as specified and directed by Engineer-in-Charge.
Dismantling of water tanks and removing to store capacity of tank exc. 250 but not exc 500 ltr complete all as specified and directed by Engineer-in-Charge.
S&F rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top ) hoisted and fixed in position all as specified in SSR part-I ,500 ltr capacity including, 20mm dia Ball brass valves, high pressure, with polyethylene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
Dismantling of water tanks and removing to store capacity of tank exc. 500 but not exc 1000 ltr complete all as specified and directed by Engineer-in-Charge.
S&F rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top ) hoisted and fixed in position all as specified in SSR part-I ,1000 ltr capacity including, 20mm dia Ball brass valves, high pressure, with polyethylene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
Taking up or down 15mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed by Engineer-in-Charge.
Taking up or down 20mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed by Engineer-in-Charge.
Taking up or down 25mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed by Engineer-in-Charge.
S&F for 16mm bore of CPVC of food grade pipes SDR 11 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed by Engineer-in-Charge.
S&F 20mm boreTubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge.
S&F 25mm boreTubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge.
S&F in repair 20mm bore Gun metal gate valves with iron wheel head screwd both ends for iron pipes complete all as specified and directed by Engineer-in-Charge.
S&F in repair 25mm bore Gun metal gate valves with iron wheel head screwd both ends for iron pipes complete all as specified and directed by Engineer-in-Charge.
S&F in repair Brass chromium plated shower rose 125mm size complete all as specified and directed by Engineer-in-Charge.
S&F in repair brass chromium plated Tubular towel rail 20mm dia, D type, 60cm long between flanges complete all as specified and directed by Engineer-in-Charge.
Dismantling of soil, rain water pipes with fittings of any description complete all as specified and directed by Engineer-in-Charge.
S&F 75mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid on wall complete all as specified and directed by Engineer-in-Charge.
S&F 110mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid on wall complete all as specified and directed by Engineer-in-Charge.
S&F 75mm bore PVC (SWR) bend any radius complete all as specified and directed by Engineer-in-Charge.
S&F 110mm bore PVC (SWR) bend any radius complete all as specified and directed by Engineer-in-Charge.
S&F 75mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed by Engineer-in-Charge.
S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed by Engineer-in-Charge.
S&F 75mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed by Engineer-in-Charge.
S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed by Engineer-in-Charge.
S&F 75mm PVC (SWR) vent cowl complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm PVC (SWR) vent cowl complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 75mm bore PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
S&F in repair stainless steel soap dish, approximate size 130x120x30mm complete all as specified and directed by Engineer-in-Charge.
S&F in repair Toilet paper holder with flat recessed type stainless steel complete all as specified and directed by Engineer-in-Charge.
S&F in repair sheet glass corner wall mounted shelf assembly consisting of 5.5mm thick sheet glass 220mmX220mm size with chromium plated bracket guard and railing 50mm high complete all as specified and directed by Engineer-in-Charge.
S&F in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed by Engineer-in-Charge.
Cutting chases in stone, concrete block or slab walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth complete all as specified and directed by Engineer-in-Charge.
M&L for MS framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of New or old previously untreated steel or iron surfaces of any description over 10cm in girth or width and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted steel or iron surfaces of any description over 10cm in girth or width and painting with two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L for special treatment to floor/wall sunken portion including demolition of PCC with plaster of entire sunken area (bottom & sides) including removal of demolished material exc 500m and n exc 1000m, prepration of surface by cleaning to remove loose particles, dust, latance etc to bottom and sides, replacement of floor trap, and applying 10mm thick plaster in CM (1:4) with WPC liquid Conplast 421, and applying one coat each of Nitoproof 100 priming coat @1Ltr/5Sqm, after the priming coat applying Nitoproof 120 on plastered surfaces @1Ltr/2.5Sqm, filling the sunken floor with PCC (1:5:10) using brick bat and WPC Conplast - 421, rendering again 40mm thick in CM (1:4) mixed with WPC Conplast - 421, area of floor for toilet/bathroom upto 1.2Sqm complete all as specified and directed by Engineer-in-Charge.
M&L for special treatment to floor/wall sunken portion including demolition of PCC with plaster of entire sunken area (bottom & sides) including removal of demolished material exc 500m and n exc 1000m, prepration of surface by cleaning to remove loose particles, dust, latance etc to bottom and sides, replacement of floor trap, and applying 10mm thick plaster in CM (1:4) with WPC liquid Conplast 421,and applying one coat each of Nitoproof 100 priming coat @1Ltr/5Sqm, after the priming coat applying Nitoproof 120 on plastered surfaces @1Ltr/2.5Sqm, filling the sunken floor with PCC (1:5:10) using brick bat and WPC Conplast - 421, rendering again 40mm thick in CM (1:4) mixed with WPC Conplast - 421, area of floor for kitchen upto 0.5Sqm complete all as specified and directed by Engineer-in-Charge.
M&L for special treatment to floor/wall sunken portion with demolition of PCC with plaster of entire sunken area (bottom & sides upto dado level) including removal of demolished material exc 500m and n exc 1000m, prepration of surface by cleaning to remove loose particles, dust, latance etc to bottom and sides, replacement of floor trap, and applying 10mm thick plaster in CM (1:4) with WPC liquid Conplast 421, and applying one coat each of Nitoproof 100 priming coat @1Ltr/5Sqm, after the priming coat applying Nitoproof 120 on plastered surfaces @1Ltr/2.5Sqm, filling the sunken floor with PCC (1:5:10) using brick bat and WPC Conplast - 421, rendering again 40mm thick in CM (1:4) mixed with WPC Conplast - 421, area of floor for bathroom exc 1.20Sqm complete all as specified and directed by Engineer-in-Charge. Note : PVC pipes and fittings shall be measured and paid separatley except floor trap under relevant items.
Demolition of cement concrete (reinforced) in roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work complete all as specified and directed by Engineer-in-Charge.
M & L for RCC (nominal mix) Type B1 1:2:4 (20 mm graded aggregate) as in chajjas complete all as specified and directed by Engineer-in-Charge.
Formwork to chullah hoods, chajjas, troughs and similar items including edges, flat rough finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
M&L TMT bars 6mm to 8mm dia cut to length bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work, PCC block or stone / boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed by Engineer-in-Charge.
M&L for Pre-cast cement concrete block masonry Type C1 1:3:6 (20 mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in CM (1:6) complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm thick plaster in CM (1:4) on faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Dismantling of timber scantlings framed work in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and directed by Engineer-in-Charge.
M&L second class hard wood clean swan, timber fixed in scantling of unframe roof work complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in concrete bed to 150mm bore drain pipes including packing under & haunching against the sides of pipes after they are laid & tested for 150mm bore pipe including demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement concrete mortar complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced concrete pipes 150mm bore class NP-2, laid and jointed complete with collars, complete all as specified and directed by Engineer-in-Charge.
M&L for precast cement concrete 1:2:4 type B-1 using (20mm aggreates) set in CM (1:4) as in cover slabs (for manhole etc) & simillar articles with plain faces complete (Reinforcement will be measured and paid separatly) complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out hard/dense soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in including spreading, levelling, watering & well ramming in layers n.exc 25cm complete all as specified and directed by Engineer-in-Charge.
M&L for Providing, cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) in lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directing complete all as specified and directed by Engineer-in-Charge.
M&L for applying neat cement slurry with 3 kg of cement per sqm with mixing of liquid water proofing compound as per manufacturer instructions over surfaces roof, terrace, projection, chajjas, walls after prepration and cleaning of surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 10mm thick cement plaster in CM (1:3) on concrete surfaces of roof, terrace, projection, chajjas, walls (old or new), finished even and smooth (without using extra lime or cement) with mixing of WPC as per manufacturer instructions complete all as specified and directed. Note : WPC shall be measured and paid separately under relevant items.
M&L for Applying evenly a priming coat with bituminous primer at 4 Kg per 10 sq metre over plastered/concrete surfaces including prepration complete all as specified and directed by Engineer-in-Charge.
M&L for laying of APP based polymeric membrane minimum weight 3Kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt not less than 150gm/sqm) by torched applicatilaid over and including applying evenly a tack coat of industrial bitumen S-35 grade (30/40) at the rate of 1.2 kg per Sq.m including cleaning surfaces by on and as per manufacturer instructions complete all as specified and directed by Engineer-in-Charge.
M&L for Providing cement concrete cement concrete in roof kerbs or mud stops, rounded or chamfered on edges (1:2:4) type Bo(using 12.5 mm graded stone agg) for coved fillets of radius 75mm provided at junction of roof and parapet/vertical surfaces, pedding concrte to achive slope as required & making plateform for water tank on roof slab etc complete all as specified and directed by Engineer-in-Charge.
M&L for 40mm thick cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) over roof, terrace using integral WPC as per manufacturer's instructions well compacted and fair finish complete all as specified and directed by Engineer-in-Charge. Note : WPC shall be measured and paid separatley under relevant items.
Forming "V" grooves in concrete surfaces of roofs or terracing n exc 10mm widep and n exc 10mm deep, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and directed by Engineer-in-Charge.
M&L for 10 mm thick SRI cool roof, UV Rays resistant anti skid tiles of size exceeding 0.06 sqm but not exceeding 0.11 sqm, on terrace/roof surface over 15mm thick screed bed in CM (1:4) set and jointd grouted and flush pointed with epoxy Based Waterproof Tile Filler to match the colour of tiles including over Geotextile 120Gm non woven 100% polyster of thickness 1 to 1.25mm bonded to the water proofing membrane with intermittent touch by heating the membrane by butane torch as per manufacturer's instruction complete all as specified and directed by Engineer-in-Charge.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description, complete all as specified and directed by Engineer-in-Charge.
M&L for 150 mm size SS fancy heavy duty type handle for modular cabinets, drawers, cupboard shutters with necessary screw arrangement complete all as specified and directed by Engineer-in-Charge.
M&L for 3D soft close 4H cabinet hinges for modular cabinets, cupboard shutters with necessary screw arrangement complete all as specified and as directed.
S&F in repair 15mm bore two way Bib taps (for health faucet/jet spray) fancy type, chromium plated, cast copper ally with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
Removal of steel section, steel articles of any size and any descrption from site to MES store including loading and unloading without damaging steel sections or articles complete all as specified and directed by Engineer-in-Charge.
M&L for 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with L-type or J-type or cranked hook bolts and washer in roof, wall etc. complete all as specified and directed by Engineer-in-Charge.
M&L for Chipping of slab/columns/beams/chajjas/parapet/roof projection/balcony/staircase and removing loose mortar with chisel hammer without much impact on concrete surface, clean the surface by sand blasting the surface using river sand with minimum of 6 kg pressure at the nozzle or air blow by electric pressure blower by mechanical compressor, cleaning the exposed reinforcement with wire brushes etc and disposal of debris foe all lead and lifts, all complete all as specified and directed by Engineer-in-Charge.
M&L for Cleaning & applying rust remover (CICO Clean-o rust) in two coats over rusted reinforcement surface and providing anti corrosive coating with two component epoxy based zinc rich primer/Rust passivation Inhibitor coat at the rate of 2-3 sq. mtr/ltr not less than 50 microns dft with CICO ZINCILATE-500 or equivalent to reinforcement surface as per manufacturer’s instructions including all machinery, tools tackles and clearing of debris complete all as specified and directed by Engineer-in-Charge. Make : CICO clean-O-rust, CICO ZINCILATE-500 or equivalent in Fosroc/Dr Fixit/ACC/L&T/STP/Fosroc as approved by GE.
M&L of new steel or rebars by drilling holes with 10 mm to 20mm dia and 100 to 200mm deep as per IS code of 10D formula and filling the holes after inserting of reinforcement dia 8 to 16mm for anchoring at ends/shear connector and filled the holes with one or two component styrene free vinylester resin anchor or two components, styrene & cement free epoxy- acrylate fixing and anchoring compound (having the technical parameters mentioned in material specifications) using standard sealant applicator gun after drilling holes of required diameter at required locations, for holding / fixing / placing in position the steel mesh reinforcement at desired level/ stretching complete all as specified and directed by Engineer-in-Charge. Note : Steel/reinforcement shall be paid and measured separately under relevant items. Make: CICO RESIFIX-G or equivalent in Fosroc/Hilti and Master builder (BASF) as approved by GE.
M&L for providing Micro concrete with CICO MICROCRETE at the rate of 25kg per 0.0125 m3 with 20% properly graded 5mm to 10mm silt free aggregate as per manufacturer instructions and mixing concrete with mechanically electrically operated mixer machine etc complete all as specified and directed by Engineer-in-Charge. Make: CICO MICROCRETE of CICO Technologies ltd or equivalent in Fosroc/STP/BASF as approved by GE.
M&L for Epoxy Bonding Agent suitable for bonding new to old concrete, bricks and steel components, bricks, tiles etc after the prepration of old concrete/RCC surface by cleaning and removing of dust, dirt, loose particles, laitance etc by wire brushing, scrapping and washing with water complete all as per manufacturer's instructions and directed by Engineer-in-Charge. Make: CICO Technologies ltd or equivalent in Fosroc/STP/BASF or Equivalent as approved by GE.
E&M WORK Taking down carefully copper/aluminium point wiring (light, fan socket or power) complete including PVC Casing Capping/conduit, fixture and fitting such as switches, ceiling roses, pendents, regulators, sockets , light fitting etc removing materials for taking credit and making good disturbed surface of walls,floors etc complete all as specified and directed by Engineer-in-Charge.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified and directed by Engineer-in-Charge.
Taking down fan, ceiling/exhaust cable end, dismantling blades and removing fan and blades to store including making good disturbed surface to match the existing surface complete all as specified and directed by Engineer-in-Charge.
Taking down existing sub main wiring /Service wire of any description and size including earth wire, quities and making good disturbed surfaces of walls, floors etc. Including one run of 2mm dia bare earth continuity wire complete all as specified and directed by Engineer-in-Charge. Note:- Two runs of aluminium / Copper conductor, and one run of GI earth wire will be measured and paid as one unit only
M&L for point wiring in concealed with PVC insulated, unsheathed, single core multistandard copper conductor cable (FRLS) of size 1.5 Sqmm 1100 Vilts grade including 1.5 Sqmm insulated, unsheated multistranded copper conductor cable for earth continuity wire to be drawn through in and including PVC conduit medium grade ISI marked with accessories including necessary modular metal flush box/pressed steel terminal boxes and modular white cover plate 3mm thick ISI marked with laminated sheet cover and brass screws with cup washers for fixing switches, socket, fan regulated etc including all necessary wall cutting chases and making good disturbed surfaces in cement mortar 1:3 for One light/CB point controlled by one switch complete all as specified and directed by Engineer-in-Charge.
All as per Item No.174.00 above but for one ceiling fan point controlled by one switch complete all as specified and directed by Engineer-in-Charge.
All as per Item No.174.00 above but for one exhaust/wall mounting fan point controlled by one switch complete all as specified and directed by Engineer-in-Charge.
All as per Item No.174.00 above but for one One light point controlled by two 2-way point switch complete all as specified and directed by Engineer-in-Charge.
All as per Item No.174.00 above but for socket outlet 3/2pin 5 amps socket outlet point on the independent board complete all as specified and directed by Engineer-in-Charge.
All as per Item No.174.00 above but for one socket outlet 3/2pin 5 amps point on the same board with other switches complete all as specified and directed by Engineer-in-Charge.
All as per item No.174.00 here-in-before but for one socket outlet/metal clad socket of 15/16 Amps fixed on independent board with 2.5 Sq mm multistranded copper conductor wire FRLS PVC insulated and 2.5 Sq mm copper conductor wire FRLS PVC insulated using as earth wire complete all as specified and directed by Engineer-in-Charge.
All as per item No.174.00 here-in-before but for one socket outlet/metal clad socket of 15 Amps fixed on independent board with 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated and 4.0 Sq mm copper conductor wire FRLS PVC insulated using as earth wire complete all as specified and directed.
S&F Sheet metal and neutral enclosure single pole with two pin and earth plug and socket single pole MCB 20 Amps 240 volts fixed complete all as specified and directed by Engineer-in-charge.
S&F switch Modular switch 1 way 6A, 1 module single pole complete all as specified and directed by Engineer-in-charge.
S&F Modular switch 1 way 16A, 1 module single pole confirming to IS 3854 : 1997 complete all as specified and directed by Engineer-in-charge.
S&F switch Modular switch 2 way 6A, 1 module single pole complete all as specified and directed by Engineer-in-charge.
S&F Modular bell push 6A, 1 module single pole complete all as specified and directed by Engineer-in-charge.
S&F Modular Socket 6A 2/3 pin combined 2 module outlet, multipurpose complete all as specified and directed by Engineer-in-charge.
S&F Modular Socket 16/6A 3 pin combined 2 module outlet, multipurpose complete all as specified and directed by Engineer-in-charge.
S&F modular fan regulator step type 120W 2 module complete all as specified and directed by Engineer-in-charge.
S&F switch piano, flush type, single pole, one way 5 amps 230 Volts AC confirming to IS: 3854 and ISI marked complete all as specified and directed by Engineer-in-charge.
S&F switch piano, flush type, single pole, two way 5 amps 230 Volts AC confirming to IS: 3854 and ISI marked complete all as specified and directed by Engineer-in-charge.
S&F socket outlet 2 in 1, 3 pin 5/6 amp flush type complete all as specified and directed by Engineer-in-charge.
S&F socket outlet 2 in 1, 3 pin 16 amp flush type complete all as specified and directed by Engineer-in-charge.
S&F switch piano, flush type single pole, one way 15 amps 230 Volts AC confirming to IS: 3854 and ISI marked complete all as specified and directed by Engineer-in-charge.
S&F ceiling rose surface bakelite 65 x 50 mm 2/3 terminais complete all as specified and directed by Engineer-in-charge.
S&F bell push switch piano, flush type, 5 Amps single pole, 230 Volts AC confirming to IS: 3854 and ISI marked complete all as specified and directed by Engineer-in-charge.
S&F call bell push flush type, 5 Amps single pole and ISI marked complete all as specified and directed by Engineer-in-charge.
S&F fan regulator electronic type five step controlled 230 volt 50 Hz for confirming to IS: 3854 and ISI marked complete all as specified and directed by Engineer-in-charge.
S&F MCB SP 240 volts, 6 to 32 Amps, 10 KA,C series complete all as specified and directed by Engineer-in-charge.
S&F MCB SPN 240 volts, 32 Amps, 10 KA C series complete all as specified and directed by Engineer-in-charge.
S&F MCB TPN 415 volts, 63 Amps, 10 KA, " C " Series complete all as specified and directed by Engineer-in-charge.
S&F for sheet metal enclosure MCB SPN DB 8 way made out of 1.5 mm thick sheet metal enclosure IP 43 with 200 Amps rated bus bar 240 volts double door with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCBs and isolators etc complete all as specified and directed by Engineer-in-charge.
S&F for sheet metal enclosure MCB DB TPN 4 way made out of 1.5 mm thick sheet metal enclosure IP 43 with 200 Amps rated bus bar 415 volts double door with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCBs and isolators etc complete all as specified and directed by Engineer-in-charge.
S&F load line vertical DBs TPN 4 way 415 V double door type with IP 54 protection, isolated neutral bar, cement spill protector door earthing fixed on wall semi flush with incoming control through MCCB 4 poles 125 Amps 16 KA blanking plates complete with all accessories complete all as specified and directed by Engineer-in-charge. Make :- Indoasian Cat part No. 812040 or equivalent model of Make ABB, Schneider, Havells, C&S as approved by GE.
S&F ceiling fans Five star rated (BLDC) white/ivory 1200mm sweep, 3 wings suitable for operator on AC 220/230 Volts single phase, 50Hz supply with down rods including necessary PVC insulated flexible wire 3 core for connecting from ceiling rose to connector etc complete all as specified and directed by Engineer-in-charge.
S&F steel body exhaust fan 300mm sweep with louver complete fixed to wall with suitable MS bolts, grouted to wall and connecting up including provision of cable from connector to fan with flexible copper cable 24/0.2mm complete all as specified and directed by Engineer-in-charge.
S&F plastic body exhaust fan 250mm sweep with louver complete fixed to window/wall with suitable fastening and connecting up including provision of cable from connector to fan with flexible copper cable 24/0.2mm complete all as specified and directed by Engineer-in-charge.
Cutting of wall with mason for making window suitable for fixing of 300/250 mm exhaust fan and making good as per existing surface of wall complete all as specified and directed by Engineer-in-charge.
S&F rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for external dia 20mm bore concealed in wall/ceil;ing/flooring etc for telephone/TV point complete all as specified and directed by Engineer-in-charge.
S&F PVC junction boxes (1 to 4 way) as required as site suitable for 20mm dia PVC pipe conduit complete all as specified and directed by Engineer-in-charge.
S&F TV sockets complete with all accessories complete all as specified and directed by Engineer-in-charge.
S&F fixing RJ 11 gang with shutter (Telephone Jack) complete with all accessories complete all as specified and directed by Engineer-in-charge.
S&F modular metal flush box 1/2 module for telephone and TV points complete all as specified and directed by Engineer-in-charge.
S&F modular white cover plate with frame 1 module for telephone and TV points complete all as specified and directed by Engineer-in-charge.
M&L for submain wiring with approved colour code/as per IS (Red,black & green for single phase) concealed conduit circuit with two runs of single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 4.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 4.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engineer-in-charge. Note :- Two runs of 4.00 Sqmm cable & one run of 4.00 Sqmm cable continuity earth and one run of PVC conduit with all necessary accessories shall be paid as one unit length
M&L for submain wiring with approved colour code/as per IS (Red,black & green for single phase)concealed conduit circuit with two runs of single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 6.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engineer-in-charge. Note :- Two runs of 6.00 Sqmm cable & one run of 6.00 Sqmm cable continuity earth and one run of PVC conduit with all necessary accessories shall be paid as one unit length
M&L for submain wiring with approved colour code/as per IS (Red,black & green for single phase) concealed conduit circuit with four runs of single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 10.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 10.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engineer-in-charge. Note :- Four runs of 10.00 Sqmm cable & one run of 10.00 Sqmm cable continuity earth and one run of PVC conduit with all necessary accessories shall be paid as one unit length
Removing the storage type electric water heater of 25 Ltrs capacity from the existing location prior to commencement of work and keeping in safe custody and refixing the same at the same location after completion of necessary work in bathroom complete all as specified and directed by Engineer-in-charge.
S&F electric water heater storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. and fixing on wall including with toggle bolts with flexible pipe complete all as specified and directed by Engineer-in-charge.
S&F LED batten suitable for indoor application 20W , 4 feet length wall mounted with aluminium housing end cap made of ABS plastic of white colour finish and high efficiency translucence (HET) diffuser and integral electronic driver including two point surface mounting on wall/ceiling and connecting up with two core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-charge.
S&F LED batten suitable for indoor application 10W , 2 feet length wall mounted with aluminium housing end cap made of ABS plastic of white colour finish and high efficiency translucence (HET) diffuser and integral electronic driver including two point surface mounting on wall/ceiling and connecting up with two core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-charge.
S&F LED light fitting 1x9W / 1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-charge.
S&F Lamp holder(Angular) PVC/polycarbonate type with back plate suitable for battern fittings complete all as specified and directed by Engineer-in-charge.
S&F decorative type wall mounting brushed nickel finish fixture with opal glass diffuser suitable for 9 Watt LED lamp B22 base complete all as specified and directed by Engineer-in-charge. Make :- Havells Cat part No. LHFOECE1TZ1B014 or equivalent make and model as approved by GE.
S&F LED lamp10 Watt minimum lumen output 950 lumens at 6500K CCT for batten holders complete all as specified and directed by Engineer-in-charge.
M&L for inverter point wiring for light, ceiling fan and 5 Amp socket with 2.5 Sqmm PVC insulated, unsheathed, single core multistandard copper conductor cable (FRLS) , 1100 volts grade including 1.5 Sqm PVC insulated unsheathed copper conductor for earth cuntinuity wire to be drawn through in and including PVC conduit medium grade ISI marked with all accessories upto the main DB and 15 Amps switch socket combination with gang box flushed in wall for inverter power supply complete all as specified and directed by Engineer-in-charge.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to GI earth wire 4 mm dia connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, GI earth wire will be protected by 15 mm dia GI pipe 'medium grade', watering pipe 20 mm dia GI 'Medium grade', GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to O/H continious earth wire on pole, testing the earthing after completion all as specified and shown in electric plate No 5 of MES SSR Part-I 1991 print complete all as specified and directed.
S&F 25mm bore Gun metal globe or gate valves with iron wheel head screwd both ends for iron pipes for unions complete all as specified and directed by Engineer-in-Charge.
S&F 20mm bore Gun metal globe or gate valves with iron wheel head screwd both ends for iron pipes for unions complete all as specified and directed by Engineer-in-Charge.
Lalit and Brothers
Devi Engineeing
AMBEY MAA CONSTRUCTION COMPANY
M/S HARIOM CONSTRUCTION COMPANY
Paliwal Construction Company
S.K. INFRASTRUCTURE
M/S Tanisha Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .