Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹48.4 LAccepted-AOC KAKOPATHER P O P S KAKOPATHER DIST TINSUKIA ASSAM | TINSUKIA | ASSAM | 786125 | ₹48.4 L | L 1 | Accepted-AOC L 1 |
| 2 | L 2₹48.7 L+₹35,000 (0.72%)Rejected-AOC | ₹48.7 L+₹35,000 (0.72%) | L 2 | Rejected-AOC L 2 |
| 3 | L 2₹48.7 L+₹35,000 (0.72%)Rejected-AOC VILL SARUPUR P O P S KAKOPATHER TINSUKIA ASSAM PIN 786152 | TINSUKIA | ASSAM | 786152 | ₹48.7 L+₹35,000 (0.72%) | L 2 | Rejected-AOC L 2 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Non responsive |
| 5 | Rejected-Technical | - | - | Rejected-Technical Non responsive |
Tender Value
₹48.7 L
EMD Value
₹97,495
Closing Date
15 Oct 2022, 2:00 pmClosed
Mission Director NHM Assam
Office of Mission Director, NHM, Assam
Repairing Renovation of 592 Nos of Sub Centre to upgrade them as Health n Wellness Centre at various places of Assam from RoP 2021 22 Group 55 7 nos SC in Tinsukia District
2022_NHM_27180_2
NHM32050462021ConstructionNHM
Open Tender
Civil Works - Building
Item Rate
120 days
Tinsukia District
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
₹97,495
Yes
13 Jul 2023
26 Sept 2022
17 Oct 2022
26 Sept 2022
15 Oct 2022
26 Sept 2022
Amount
Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc. including refilling ( return filling ) the quantity as necessary after completing of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (Upto a depth of 2m below the existing ground level) In ordinary soil.
Earth/Sand filling in plinth in layer not more than 150 mm thick including necessary carriage,watering,ramming etc. complete as directed and specified including payment of land compensation, Forest Royalty, Sales Tax and other duties and taxes as may be necessary ( With river sand or silt by truck carriage including loading and unloading )
Plain Cement concrete Works with coarse aggregate of size 13 mm to 32mm in foundation of steps, footing of column and plinth beam as directed and specified including curing complete (shuttering where necessary shall be measured and paid separately) Proportion 1:3:6
In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. M15
Plain Cement concrete Works with coarse aggregate of size 13 mm to 32mm in foundation of steps, footing of column and plinth beam as directed and specified including curing complete (shuttering where necessary shall be measured and paid separately(b) In prop 1cement: 4 sand :8 coarse aggregate by volume
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.(I) Using Mixer Machine(A) In substructure up to plinth level
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) In super structure from plinth level up to 1st floor levelN) Without using admixture, plasticiser ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.a) M15 grade concrete or Prop. 1:2:4
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) P) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required.a) M15 grade concrete or Prop. 1:2:4
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately)(B) In super structure from plinth level up to 1st floor level. i) Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. a) M15 grade concrete or Prop. 1:2:4
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in-situ reinforced concrete and plain concrete work.Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in-situ reinforced concrete and plain concrete work. Sides of tie beams, grade beams etc. at or below ground level. Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in-situ reinforced concrete and plain concrete work.Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. For depth not exceeding 1.0M. Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in-situ reinforced concrete and plain concrete work .Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in-situ reinforced concrete and plain concrete work Columns, Pillars, Posts & Strut(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face(ii) Using 25mm thick plank
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Providing brick soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling.
Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in substructure upto plinth level ( in prop. 1:4 )
Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in substructure upto plinth level ( in prop. 1:3 )
Dismantling all types of ceiling, partition and wall lining and stacking the materials as directed by the department for all levels
Demolishing brickwork including stacking of serviceable materials and disposal of unserviceable materials as directed for all levels
Dismantling all types of corrugated/ trapezoidal sheet roofing including ridges, hips, valleys and gutters etc. and stacking the materials as directed by the department for all levels
Demolishing CC floors of various thickness including top layer and base course and disposal of debris as directed for all levels.
Dismantling and removing the existing door and window frame (chowkath) both wooden and steel of different sizes without damaging the walls and removing the frame and necessary repairs to the edges of the walls as directed for all levels (i) Area of door/window up to 3.00 m2
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine(B) In super structure from plinth level up to 1st floor level.ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser b) M20 grade concrete or Prop. 1:1.5:3
112 mm thick 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (a). In cement mortar in proportion 1:4.(1 cement:4 sand)
40 mm thick cement concrete floor consisting of 25 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 12.5 mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) finished with a floating coat of neat cement finish using cement slurry for bond @ 2.75 kg. per square metre of floor area , wearing layer is to be laid in panels including curing etc. complete as directed.
Providing Ceramic Tiles of approved quality, size, shape and thickness not less than 8 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix-A Tile Choksey/ Sika/ Pedelite/ Rouf/ White cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed (coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). Of size 300mmx300mm and above
Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). ii) Of size 200mmx300mm and above
15 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. B) On fair side (b). In cement mortar 1:4
Providing, fitting and fixing hard board sheet ceilling with approved quality with necessary nails, wood screws including 1st class local wood 50mm x 12mm ( hollock/ bonsum/ sundi ) beading including paining two coats to timber beads complete as directed ( ceilling joist to be measured and paid separately ). (b). 4.5 mm thick
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (b) With 1st class timber (Bonsum/ Sundi)
Providing wood work in frame of false ceilling partitions etc.sawn wrought framed hoisted and fixed in positon with spikes, nails, m.S flat,angle/ cleats with bolt and nuts complete including kiricide oiling two coats to unexposed surfaces of the timber (m.S flats, angle cleats, and bolt and nuts required for flat and angle cleats wherever use shall be measured and paid separately). With Hollock/Bonsum
Providing, fitting and fixing full panelled doors/ windows including oxidised m.S butt hinges (100mm x75 mm x3.55mm) with necessary screws (other fittings to be measured and paid separately ) (C)C) With 1st class Local wood ( Bola wood),35 mm thick
Providing, fitting and fixing full panelled doors/ windows including oxidised m.S butt hinges (100mm x75 mm x3.55mm) with necessary screws (other fittings to be measured and paid separately ) ,(B) With 1st Local Wood(Hollock/Bonsum)35 mm thick
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). b) TMT Bar (I) TATA/ SAIL
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). c) ISI approved Mild steel reinforcement bar(M.S.Bar)
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G black wire. (i) TMT Corrosion resistant steel (CRS) reiforcement bar
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated out of M.S. black-tubes conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed.
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. (c) Fixed to Brickwork/P.C.C/R.C.C.
(n) Distempering two coats with oil bound distemper of approved brand and manufacture and of required shade on new wall surface to give an even shade, over and including a priming coat with alkali resistant primer of approved brand and manufacture after throughly brooming the surface free from mortar dropings and other foreign matter and also including preparing the surface even and sand papered smooth. (ii). Top coat
Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials.
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.(i).Surfaces over 100mm in width or girth.a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.(i).Surfaces over 100mm in width or girth.a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
f) Distempering with dry distemper of approved brand and manufacture(two coats)and of required shade on new wall surface to give an even shade, over and including priming coat of white primer after throughly brushing the surface free from mortar dropings and other foreign matter and including preparing surface even and sand papered smooth.
h). Distempering with dry distemper of approved brand and manufacture(one coat) and of required shade on old wall surface to give an even shade,after throughly brushing the surface clean of all grease, dirt, loose pieces of scales including preparing surface even and sand papered smooth.
Finishing wall with two coats of waterproofing cement coatings of Unicem "Shakti" brand of required shade by thinning 1 part of paint with 1 part of water to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department.
Removing old paint or polish from wood and wood base surfaces with paint remover of approved brand and manufacture and making the surface even.
Synthetic enamel paint, aluminium paint / bituminus paint on steel and other metal surfaces. i).Removing old paint from steel and other metal surface and making the surface even.a). With hand scraping
Painting one coat (excluding priming coat) on previously painted steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.(i).Surfaces over 100mm in width or girth.a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Providing Pre Painted Galvalume Sheet Roofing (PPGL) at all levels including fitting and fixing self drilling, self tapping screws complete (Roof trusses, purlins etc. to be measured and paid separately.) (c) 0.45 mm thick
Providing Pre Painted Galvalume Sheet (PPGL) accessories ( Ridges / Valley / Gutter / Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Department(c) 0.45 mm thick
Providing, fitting and fixing anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (Cement concrete to be measured and paid separately).a)Side hung and Top hung windows and ventilators(ii)5mm frosted glass
Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels.(a)3 Track sliding window, (ii)5mm frosted glass
Providing and fixing anodised aluminium framed double leaf doors of approved brand with styles size 45mm x 48mm x 3.2mm, top rails 50mm x 45mm x 2.5mm, lock rails 48 mm x 45mm x 2.5mm, bottom rails 100mm x 45mm x 2.5mm fitted with tapper clips of size 20mm x15mm x1.2mm complete with automatic floor mounted door closure, butterfly type handles, special cylindrical lock, concealed type aluminium tower bolt,neoprene dryset rubber gusket, door felt gusket, etc.complete as directed by the Department at all levels. (i)5mm thick frosted glass and 12mm thick prelaminated particle board
Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Supplying, fitting and fixing goat proof wire fencing 1200mm high with horizontal wire spacing at100mm, 100mm,100mm,100mm,100mm,100mm,150mm,150mm,150mm,and 150mm from bottom onwards and vertical wires at 130mm apart, first 3 horizontal wires from top barbed wire apart, first 3 horizontal wires from top barbed wire 12 S.W G.x 2 plies x 4 points x 100...
Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 50mm x 6mm M.S.flat iron with another another horizontal flat at the middle, 20mm dia M.S bars at 200mm apart from bottom flat to top flat and 20 mm dia M.S. bars at 200mm apart from bottom flat to middle flat including drilling, welding etc. complete. All vertical bars are to be protruded at least 100mm above the middle and top flat is to be flattended and pointed as directed.
Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete.
Providing, fitting and fixing hard board sheet ceilling with approved quality with necessary nails, wood screws including 1st class local wood 50mm x 12mm (hollock/bonsum/sundi) beading including paining two coats to timber beads complete as directed(ceilling joist to be measured and paid separately). a) On one face of the frame
Providing and fixing clear sheet glass beded in putty and fixed with/without wooden bidding including necessary cutting and glass to be required sized(payment for wooden bead shall be made separately)
Providing barge board of size 200mm x 20mm with 1st class local Hollock/ Bonsum timber including fitting and fixing with necessary wood screws etc. complete.
Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. (b) 35mm thick.Non decorative type and block board core
Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/ 1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be filled up with 1:4:8 P.C.C. after fitting the frame with brick/ concrete works etc.complete as directed by the department for all levels. (P.C.C. to be measured and paid for seperately).(a) 1.25mm thick sheet(i) Size 90mm x 60mm (Single rebate)
Providing plinth protection with bricks laid on edge and grouted with cement mortar 1:4 and finishing with cement pointing in prop. 1:1 complete.
Supplying, fitting, fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )b) Tower bolt 250mm x 12mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )c)Dooor/window handle150mm x 12mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) a) Sliding door bolts300mm x 16mm
Colour washing with lime on wall surface (two coats) over and including a priming coat of white washing to give an even shade after throughly brooming the surface to remove all dirt, dust, mortar drops and other foreign matter.
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough sideb) In cement mortar 1:4
Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) a) White, (i) Universal Closet S Trap (Cat No.C0271) (Anglo Indian) (inclusive of seat cover)
Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) a) White,, (i)Economy Single Flush (Cat No.C8090/C8055)
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) Basin (without pedestal), a) White, (i) Star Basin 550 x 400 (Cat. No.C0450
Providing fitting & fixing laboratory sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipe etc. complete including painting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately.(B) Hindware make (White)(ii) Size 450 x 300 x 180 (Cat.No.50001))
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (iv) 100mm dia.
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (iv) 75mm dia.
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (iv) 75mm dia.
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.In exposed faces or trences110mm dia.
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.In exposed faces or trences75mm dia.
Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipeExposed or in trenchesc) 25 mm nominal outer dia pipe
(B) Concealed pipe with cutting chases & making good the wallsa) 15 mm nominal outer dia pipe
(B) Concealed pipe with cutting chases & making good the wallsa) 20 mm nominal outer dia pipe
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) Jaquare make (a)Continental /(i)ClarionStandard
Supplying and fitting gun metal country pit valve ( full way valve) I.S.I Make as specified and directed.(c)25 mm dia
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex/ Polycon/Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes complete as directed.(IV)500 litre capacity (b) Polycon make
Supplying fitting, fixing, testing and commissioning of following capacity motor (Crompton Greaves/ Aquatic/ CRI/ V-Guard make) complete with necessary connection as approved, specified and directed by the Department0.5 HP single phase 1420 rpm
Wiring for light/ fan/ call bell point with 2x1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/ bell push (Anchor Penta/Gold medal /Kolor kany.Kom/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover ,ceiling rose (Anchor/Gold medal /Kolor kany.Kom / Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the Deptt. Short point up to 3.00 metre. length.
Wiring for light/ fan/ call bell point with 2x1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/ bell push (Anchor Penta/Gold medal /Kolor kany.Kom/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover ,ceiling rose (Anchor/Gold medal /Kolor kany.Kom / Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the Deptt. Medium point up to 6.00 metre. Length.
Wiring for light/ fan/ call bell point with 2x1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/ bell push (Anchor Penta/Gold medal /Kolor kany.Kom/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover ,ceiling rose (Anchor/Gold medal /Kolor kany.Kom / Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the Deptt. Long point up to 10.00 metre. Length.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including providing and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch ( Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.),GI/ MS switch board (I.S.I. marked) with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete. Short point up to 3.00 metre. length.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including providing and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch ( Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.),GI/ MS switch board (I.S.I. marked) with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete. Medium point up to 6.00 metre. Length.
Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including providing & fixing 5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) earthing the 3rd pin of the socket as required on the switch board in flat ISI marked casing 'n' capping system, when fitted on same board of light and fan.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in flat 19 mm ISI marked casing 'n' capping system.
With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 8 way SPN double door
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.40A
Supplying & laying of 6SWG GI. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying and fixing of Plain Pendent holder (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) with twin twisted flexible cord including connection as approved by the Deptt.)complete Without Lamp
Supplying and fitting of 11/15 Watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/ pendent holder etc. as specified and directed by the deptt
Supplying including installation of Inverter (Su-Kam/ Microtech/ V-Guard/ Luminous) with Battery and its case as per direction and specified by the DepttNon Schduled items
Internal wiring for inverter
safety box for inverter
fitting of S Hook
SANTANOO MORAN
S.B. ENTERPRISE
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .